  1. arXiv:2204.04575  [pdf, other

    hep-ex nucl-ex physics.ins-det

    The COHERENT Experimental Program

    Authors: D. Akimov, S. Alawabdeh, P. An, A. Arteaga, C. Awe, P. S. Barbeau, C. Barry, B. Becker, V. Belov, I. Bernardi, M. A. Blackston, L. Blokland, C. Bock, B. Bodur, A. Bolozdynya, R. Bouabid, A. Bracho, J. Browning, B. Cabrera-Palmer, N. Chen, D. Chernyak, E. Conley, J. Daughhetee, J. Daughtry, E. Day , et al. (106 additional authors not shown)

    Abstract: The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies o… ▽ More

    Submitted 9 April, 2022; originally announced April 2022.

    Comments: 38 papers, 24 figures; Snowmass contribution

  2. Characteristic properties of Planacon MCP-PMTs

    Authors: Yu. A. Melikyan, M. Slupecki, I. G. Bearden, J. R. Crowley, D. A. Finogeev, E. J. Garcia-Solis, A. E. Guard, A. V. Harton, V. A. Kaplin, T. L. Karavicheva, J. L. Klay, I. Morgan, I. V. Morozov, D. V. Serebryakov, R. Stempek, W. H. Trzaska, N. O. Vozniuk

    Abstract: A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and saturation level in terms of the average anode current are presented. This information allows one to determine the lower limit of the MCP resistance for stable Planacon… ▽ More

    Submitted 30 November, 2021; v1 submitted 29 November, 2021; originally announced November 2021.

    Comments: To be published in JINST

  3. arXiv:2111.02477  [pdf, other

    physics.ins-det

    Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

    Authors: D. Akimov, P. An, C. Awe, P. S. Barbeau, B. Becker, V. Belov, I. Bernardi, M. A. Blackston, C. Bock, A. Bolozdynya, J. Browning, B. Cabrera-Palmer, D. Chernyak, E. Conley, J. Daughhetee, J. Detwiler, K. Ding, M. R. Durand, Y. Efremenko, S. R. Elliott, L. Fabris, M. Febbraro, A. Gallo Rosso, A. Galindo-Uribarri, M. P. Green , et al. (52 additional authors not shown)

    Abstract: We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at t… ▽ More

    Submitted 6 October, 2022; v1 submitted 3 November, 2021; originally announced November 2021.

    Comments: The version accepted by JINST. The changes made as a result of the peer review process: 1. Section 8 "Global CsI[Na] QF data fit" is expanded. The main fit result and its uncertainty is NOT CHANGED. An alternative fit is now shown in Figure 14, Figure 15 is added to further validate the assumptions in the main fit. 2. The Appendix B is restructured for clarity

  4. First ground-level laboratory test of the two-phase xenon emission detector RED-100

    Authors: D. Yu. Akimov, V. A. Belov, A. I. Bolozdynya, Yu. V. Efremenko, A. V. Etenko, A. V. Galavanov, D. V. Gouss, Yu. V. Gusakov, Dj. Ed. Kdib, A. V. Khromov, A. M. Konovalov, V. N. Kornoukhov, A. G. Kovalenko, E. S. Kozlova, A. V. Kumpan, A. V. Lukyashin, Yu. A. Melikyan, V. V. Moramzin, O. E. Razuvaeva, D. G. Rudik, A. V. Shakirov, G. E. Simakov, V. V. Sosnovtsev, Yu. V. Stogov, A. A. Vasin

    Abstract: RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamats… ▽ More

    Submitted 14 October, 2019; originally announced October 2019.

    Comments: 23 pages, 13 figures

  5. Anode current saturation of ALD-coated Planacon MCP-PMTs

    Authors: E. V. Antamanova, I. G. Bearden, E. J. Garcia-Solis, A. V. Harton, V. A. Kaplin, T. L. Karavicheva, J. L. Klay, Yu. A. Melikyan, D. V. Serebryakov, M. Slupecki, W. H. Trzaska

    Abstract: We have measured and compared the characteristics of ALD-coated Planacon MCP-PMTs (XP85112/A1-Q-L) with their non-ALD counterparts (XP85012/A1-Q). While the later show excellent performance, the ALD-coated sensors have surprisingly low current saturation levels (~two orders of magnitude lower than expected) and extremely high gain recovery time (more than 7 orders of magnitude higher than expected… ▽ More

    Submitted 24 July, 2018; v1 submitted 10 July, 2018; originally announced July 2018.

    Comments: To be submitted to JINST

  6. Observation of light emission from Hamamatsu R11410-20 photomultiplier tubes

    Authors: D. Yu. Akimov, A. I. Bolozdynya, Yu. V. Efremenko, V. A. Kaplin, A. V. Khromov, Yu. A. Melikyan, V. V. Sosnovtsev

    Abstract: We have shown that high voltage biased Hamamatsu R11410-20 photomultipliers with a dark count rate above 10 kHz emit single photons. The effect has been observed in a few units at room temperature and temperatures reduced down to -60 degrees Celsius. The effect should be taken into account in experiments aimed on search for rare events with small energy depositions in massive liquid xenon detector… ▽ More

    Submitted 28 April, 2015; originally announced April 2015.

    Comments: Submitted to NIM A Letter to the Editor

  7. arXiv:1408.1823  [pdf

    physics.ins-det hep-ex

    Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV

    Authors: D. Yu. Akimov, V. V. Afanasyev, I. S. Alexandrov, V. A. Belov, A. I. Bolozdynya, A. A. Burenkov, Yu. V. Efremenko, D. A. Egorov, A. V. Etenko, M. A. Gulin, S. V. Ivakhin, V. A. Kaplin, A. K. Karelin, A. V. Khromov, M. A. Kirsanov, S. G. Klimanov, A. S. Kobyakin, A. M. Konovalov, A. G. Kovalenko, A. V. Kuchenkov, A. V. Kumpan, Yu. A. Melikyan, R. I. Nikolaev, D. G. Rudik, V. V. Sosnovtsev , et al. (1 additional authors not shown)

    Abstract: We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predicti… ▽ More

    Submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 8 figures