-
Tuning up Fuzzy Inference Systems by using optimization algorithms for the classification of solar flares
Authors:
Liz Angélica Ramos Medina,
Alex Francisco Bustos Pinzón,
Miguel A. Melgarejo,
Santiago Vargas Domínguez
Abstract:
In this work we describe the implementation and analysis of different optimization algorithms used for finding the best set of parameters for a Fuzzy Inference System intended to classify solar flares. The parameters will be identified among a universe of possible solutions for the algorithms, and the system will be tested in the particular case of dealing with the aim of classifying the solar fla…
▽ More
In this work we describe the implementation and analysis of different optimization algorithms used for finding the best set of parameters for a Fuzzy Inference System intended to classify solar flares. The parameters will be identified among a universe of possible solutions for the algorithms, and the system will be tested in the particular case of dealing with the aim of classifying the solar flares.
△ Less
Submitted 25 June, 2017;
originally announced June 2017.
-
Performance of a cryogenic system prototype for the XENON1T Detector
Authors:
Elena Aprile,
Ran Budnik,
Bin Choi,
Hugo Contreras,
Karl Giboni,
Luke Goetzke,
Rafael Lang,
Kyungeun Lim,
Antonio melgarejo,
Petr Shagin
Abstract:
We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K as target and detection medium for a dark matter search. In this paper we report results on the cryogenic system performance focusing on the dynamics of the gas…
▽ More
We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K as target and detection medium for a dark matter search. In this paper we report results on the cryogenic system performance focusing on the dynamics of the gas circulation-purification through a heated getter, at flow rates above 50 Standard Liter per Minute (SLPM). A maximum flow of 114 SLPM has been achieved, and using two heat exchangers in parallel, a heat exchange efficiency better than 96% has been measured.
△ Less
Submitted 29 August, 2012; v1 submitted 9 August, 2012;
originally announced August 2012.
-
Xenon Recirculation-Purification with a Heat Exchanger
Authors:
K. L. Giboni,
E. Aprile,
B. Choi,
T. Haruyama,
R. F. Lang,
K. E. Lim,
A. J. Melgarejo,
G. Plante
Abstract:
Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through a high-temperature getter. This challenges the traditional way of cooling these large detectors, since in a thermally well insulated detector, most of the cool…
▽ More
Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through a high-temperature getter. This challenges the traditional way of cooling these large detectors, since in a thermally well insulated detector, most of the cooling power is spent to compensate losses from recirculation. The phase change during recondensing requires five times more cooling power than cooling the gas from ambient temperature to -100C (173 K). Thus, to reduce the cooling power requirements for large detectors, we propose to use the heat from the purified incoming gas to evaporate the outgoing xenon gas, by means of a heat exchanger. Generally, a heat exchanger would appear to be only of very limited use, since evaporation and liquefaction occur at zero temperature difference. However, the use of a recirculation pump reduces the pressure of the extracted liquid, forces it to evaporate, and thus cools it down. We show that this temperature difference can be used for an efficient heat exchange process. We investigate the use of a commercial parallel plate heat exchanger with a small liquid xenon detector. Although we expected to be limited by the available cooling power to flow rates of about 2 SLPM, rates in excess of 12 SLPM can easily be sustained, limited only by the pump speed and the impedance of the flow loop. The heat exchanger operates with an efficiency of (96.8 +/- 0.5)%. This opens the possibility for fast xenon gas recirculation in large-scale experiments, while minimizing thermal losses.
△ Less
Submitted 4 March, 2011;
originally announced March 2011.
-
ArDM: a ton-scale LAr detector for direct Dark Matter searches
Authors:
ArDM Collaboration,
A. Marchionni,
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
J. Coleman,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
K. Mavrokoridis,
A. Melgarejo
, et al. (19 additional authors not shown)
Abstract:
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduc…
▽ More
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduce the detection threshold. Direct detection of the ionization charge with fine spatial granularity, combined with a measurement of the amplitude and time evolution of the associated primary scintillation light, provide powerful tools for the identification of WIMP interactions against the background due to electrons, photons and possibly neutrons if scattering more than once. A one ton LAr detector is presently installed on surface at CERN to fully test all functionalities and it will be soon moved to an underground location. We will emphasize here the lessons learned from such a device for the design of a large LAr TPC for neutrino oscillation, proton decay and astrophysical neutrinos searches.
△ Less
Submitted 29 December, 2010;
originally announced December 2010.
-
First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches
Authors:
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
A. Marchionni,
K. Mavrokoridis,
A. Melgarejo,
P. Mijakowski,
G. Natterer
, et al. (16 additional authors not shown)
Abstract:
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM…
▽ More
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.
△ Less
Submitted 27 October, 2010; v1 submitted 19 September, 2010;
originally announced September 2010.
-
The ArDM experiment
Authors:
ArDM Collaboration,
C. Amsler,
A. Badertscher,
V. Boccone,
N. Bourgeois,
A. Bueno,
M. C. Carmona-Benitez,
M. Chorowski,
W. Creus,
A. Curioni,
E. Daw,
U. Degunda,
A. Dell'Antone,
M. Droge,
L. Epprecht,
C. Haller,
M. Haranczyk,
S. Horikawa,
L. Kaufmann,
J. Kisiel,
L. Knecht,
M. Laffranchi,
J. Lagoda,
C. Lazzaro,
P. Lightfoot
, et al. (29 additional authors not shown)
Abstract:
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, includin…
▽ More
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
△ Less
Submitted 28 June, 2010;
originally announced June 2010.
-
Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector
Authors:
The ArDM Collaboration,
V. Boccone,
P. K. Lightfoot,
K. Mavrokoridis,
C. Regenfus,
C. Amsler,
A. Badertscher,
A. Bueno,
H. Cabrera,
M. C. Carmona-Benitez,
M. Daniel,
E. J. Daw,
U. Degunda,
A. Dell'Antone,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
D. Lussi,
J. Lozano,
A. Marchionni,
A. Melgarejo
, et al. (16 additional authors not shown)
Abstract:
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were…
▽ More
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\small\texttrademark}-foil and diffuse Tetratex{\small\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650 nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\times 25$ cm$^2$ TTX sheets were coated and assembled in the detector. Measurements in argon gas are reported providing good evidence of fulfilling the light collection requirements of the experiment.
△ Less
Submitted 1 April, 2009;
originally announced April 2009.
-
High-Temperature Superconducting Level Meter for Liquid Argon Detectors
Authors:
A. Bueno,
A. J. Melgarejo,
J. L. Navarro,
S. Navas,
A. G. Ruiz
Abstract:
Capacitive devices are customarily used as probes to measure the level of noble liquids in detectors operated for neutrino studies and dark matter searches. In this work we describe the use of a high-temperature superconducting material as an alternative to control the level of a cryogenic noble liquid. Lab measurements indicate that the superconductor shows a linear behaviour, a high degree of…
▽ More
Capacitive devices are customarily used as probes to measure the level of noble liquids in detectors operated for neutrino studies and dark matter searches. In this work we describe the use of a high-temperature superconducting material as an alternative to control the level of a cryogenic noble liquid. Lab measurements indicate that the superconductor shows a linear behaviour, a high degree of stability and offers a very accurate determination of the liquid volume. This device is therefore a competitive instrument and shows several advantages over conventional level meters.
△ Less
Submitted 25 November, 2008;
originally announced November 2008.
-
Direct WIMP identification: Physics performance of a segmented noble-liquid target immersed in a Gd-doped water veto
Authors:
A Bueno,
M C Carmona,
A J Melgarejo
Abstract:
We evaluate background rejection capabilities and physics performance of a detector composed of two diverse elements: a sensitive target (filled with one or two species of liquefied noble gasses) and an active veto (made of Gd-doped ultra-pure water). A GEANT4 simulation shows that for a direct WIMP search, this device can reduce the neutron background to O(1) event per year per tonne of materia…
▽ More
We evaluate background rejection capabilities and physics performance of a detector composed of two diverse elements: a sensitive target (filled with one or two species of liquefied noble gasses) and an active veto (made of Gd-doped ultra-pure water). A GEANT4 simulation shows that for a direct WIMP search, this device can reduce the neutron background to O(1) event per year per tonne of material. Our calculation shows that an exposure of one tonne $\times$ year will suffice to exclude spin-independent WIMP-nucleon cross sections ranging from $10^{-9}$ pb to $10^{-10}$ pb.
△ Less
Submitted 30 July, 2008; v1 submitted 6 May, 2008;
originally announced May 2008.
-
Characterization of large area photomultipliers and its application to dark matter search with noble liquid detectors
Authors:
A. Bueno,
J. Lozano,
A. J. Melgarejo,
F. J. Munoz,
J. L. Navarro,
S. Navas,
A. G. Ruiz
Abstract:
There is growing interest in the use of noble liquid detectors to study particle properties and search for new phenomena. In particular, they are extremely suitable for performing direct searches for dark matter. In this kind of experiments, the light produced after an interaction within the sensitive volume is usually read-out by photomultipliers. The need to go to masses in the tonne scale to…
▽ More
There is growing interest in the use of noble liquid detectors to study particle properties and search for new phenomena. In particular, they are extremely suitable for performing direct searches for dark matter. In this kind of experiments, the light produced after an interaction within the sensitive volume is usually read-out by photomultipliers. The need to go to masses in the tonne scale to explore deeper regions of the parameter space, calls for the use of large area photomultipliers. In this paper we address the need to perform laboratory calibration measurements of these large photomultipliers, in particular to characterize its behaviour at cryogenic temperatures where no reference from the manufacturer is available. We present comparative tests of phototubes from two companies. The tests are performed in conditions similar to those of operation in a real experiment. Measurements of the most relevant phototube parameters (quantum efficiency, gain, linearity, etc.) both at room and liquid Argon temperatures are reported. The results show that the studied phototubes comply with the stringent requirements posed by current dark matter searches performed with noble-liquid detectors.
△ Less
Submitted 27 November, 2007; v1 submitted 22 November, 2007;
originally announced November 2007.
-
Nucleon Decay Searches with large Liquid Argon TPC Detectors at Shallow Depths: atmospheric neutrinos and cosmogenic backgrounds
Authors:
A. Bueno,
Z. Dai,
Y. Ge,
M. Laffranchi,
A. J. Melgarejo,
A. Meregaglia,
S. Navas,
A. Rubbia
Abstract:
Grand Unification of the strong, weak and electromagnetic interactions into a single unified gauge group is an extremely appealing idea which has been vigorously pursued theoretically and experimentally for many years. The detection of proton or bound-neutron decays would represent its most direct experimental evidence. In this context, we studied the physics potentialities of very large undergr…
▽ More
Grand Unification of the strong, weak and electromagnetic interactions into a single unified gauge group is an extremely appealing idea which has been vigorously pursued theoretically and experimentally for many years. The detection of proton or bound-neutron decays would represent its most direct experimental evidence. In this context, we studied the physics potentialities of very large underground Liquid Argon Time Projection Chambers (LAr TPC). We carried out a detailed simulation of signal efficiency and background sources, including atmospheric neutrinos and cosmogenic backgrounds. We point out that a liquid Argon TPC, offering good granularity and energy resolution, low particle detection threshold, and excellent background discrimination, should yield very good signal over background ratios in many possible decay modes, allowing to reach partial lifetime sensitivities in the range of $10^{34}-10^{35}$ years with exposures up to 1000 kton$\times$year, often in quasi-background-free conditions optimal for discoveries at the few events level, corresponding to atmospheric neutrino background rejections of the order of $10^5$. Multi-prong decay modes like e.g. $p\to μ^- π^+ K^+$ or $p\to e^+π^+π^-$ and channels involving kaons like e.g. $p\to K^+\barν$, $p\to e^+K^0$ and $p\to μ^+K^0$ are particularly suitable, since liquid Argon imaging (...)
△ Less
Submitted 13 January, 2007;
originally announced January 2007.
-
$K^-$-Nucleus Scattering at Low and Intermediate Energies
Authors:
C. Garcia-Recio,
A. J. Melgarejo,
J. Nieves
Abstract:
We calculate $K^-$-nucleus elastic differential, reaction and total cross sections for different nuclei ($^{12}$C,$^{40}$Ca and $^{208}$Pb) at several laboratory antikaon momenta, ranging from 127 MeV to 800 MeV. We use different antikaon-nucleus optical potentials, some of them fitted to kaonic atom data, and study the sensitivity of the cross sections to the considered antikaon-nucleus dynamic…
▽ More
We calculate $K^-$-nucleus elastic differential, reaction and total cross sections for different nuclei ($^{12}$C,$^{40}$Ca and $^{208}$Pb) at several laboratory antikaon momenta, ranging from 127 MeV to 800 MeV. We use different antikaon-nucleus optical potentials, some of them fitted to kaonic atom data, and study the sensitivity of the cross sections to the considered antikaon-nucleus dynamics.
△ Less
Submitted 21 February, 2003; v1 submitted 9 October, 2002;
originally announced October 2002.