-
Partial-Field Illumination Ophthalmoscope: improving the contrast of a camera-based retinal imager
Authors:
Léa Krafft,
Elena Gofas-Salas,
Yann Lai-Tim,
Michel Paques,
Laurent Mugnier,
Olivier Thouvenin,
Pedro Mecê,
Serge Meimon
Abstract:
Effective and accurate in-vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the Partial-Field Illumination Ophthalmoscope, a patterned illumination modality,…
▽ More
Effective and accurate in-vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the Partial-Field Illumination Ophthalmoscope, a patterned illumination modality, integrated on a high pixel rate adaptive optics full-field microscope. This non-invasive technique enables us to mitigate the low signal-to-noise ratio, intrinsic of full-field ophthalmoscopes, by partially illuminating the retina with complementary patterns to reconstruct a wide field image. This new modality provides an image contrast spanning from the full-field to the confocal contrast, depending on the pattern size. As a result, it offers various trade-offs in terms of contrast and acquisition speed, guiding the users towards the most efficient system for a particular clinical application.
△ Less
Submitted 2 September, 2021;
originally announced September 2021.
-
Super-resolution in vivo retinal imaging using structured illumination ophthalmoscopy
Authors:
Yann Lai-Tim,
Laurent Mugnier,
Léa Krafft,
Antoine Chen,
Cyril Petit,
Pedro Mecê,
Kate Grieve,
Michel Paques,
Serge Meimon
Abstract:
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to live imaging has been so far mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample m…
▽ More
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to live imaging has been so far mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample motion, scattering, sample-induced optical aberrations and low signal-to-noise ratio. By using adaptive optics to compensate for optical aberrations and a reconstruction algorithm tailored for a moving and thick tissue, we successfully applied SIM to in vivo retinal imaging and demonstrated structured illumination ophthalmoscopy for high contrast super-resolution in vivo imaging of the human retina.
△ Less
Submitted 15 October, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Swept-source optical coherence tomography by off-axis Fresnel transform digital holography with an output throughput of 10 Giga voxels per second in real-time
Authors:
E. Charpentier,
F. Lapeyre,
J. Gautier,
L. Waszczuk,
J. Rivet,
S. Meimon,
L. Puyo,
J. P. Huignard,
M. Atlan
Abstract:
We demonstrate swept-source optical coherence tomography in real-time by high throughput digital Fresnel hologram rendering from optically-acquired interferograms with a high-speed camera. The interferogram stream is spatially rescaled with respect to wavelength to compensate for field-of-view dilation inherent to discrete Fresnel transformation. Holograms are calculated from an input stream of 16…
▽ More
We demonstrate swept-source optical coherence tomography in real-time by high throughput digital Fresnel hologram rendering from optically-acquired interferograms with a high-speed camera. The interferogram stream is spatially rescaled with respect to wavelength to compensate for field-of-view dilation inherent to discrete Fresnel transformation. Holograms are calculated from an input stream of 16-bit, 1024-by-1024-pixel interferograms recorded at up to 512 frames per second with a digital camera. All calculations are performed by a NVIDIA TITAN Xp graphics card on single-precision floating-point complex-valued arrays (32-bit per quadrature). It allows sustained computation of 1024-by-1024-by-256-voxel volumes at 10 billion voxel/s, from which three perpendicular cuts are displayed in real-time at user-selected locations, up to 38 frames per second.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.
-
Optical Incoherence Tomography: a method to generate tomographic retinal cross-sections with non-interferometric imaging systems
Authors:
Pedro Mecê,
Elena Gofas-Salas,
Michel Paques,
Kate Grieve,
Serge Meimon
Abstract:
Optical tomographic cross-sectional images of biological samples were made possible by interferometric imaging techniques such as Optical Coherence Tomography (OCT). Owing to its unprecedented view of the sample, OCT has become a gold standard, namely for human retinal imaging in the clinical environment. In this Letter, we present Optical Incoherence Tomography (OIT): a completely digital method…
▽ More
Optical tomographic cross-sectional images of biological samples were made possible by interferometric imaging techniques such as Optical Coherence Tomography (OCT). Owing to its unprecedented view of the sample, OCT has become a gold standard, namely for human retinal imaging in the clinical environment. In this Letter, we present Optical Incoherence Tomography (OIT): a completely digital method extending the possibility to generate tomographic retinal cross-sections to non-interferometric imaging systems such as en-face AO-ophthalmoscopes. We demonstrate that OIT can be applied to different imaging modalities using back-scattered and multiply-scattered light including systems without inherent optical sectioning. We show that OIT can be further used to guide focus position when the user is "blind" focusing, allowing precise imaging of translucent retinal structures, the vascular plexuses and the retinal pigment epithelium using respectively split detection, motion contrast, and autofluorescence techniques.
△ Less
Submitted 27 February, 2020;
originally announced February 2020.
-
Jointly super-resolved and optically sectioned Bayesian reconstruction method for structured illumination microscopy
Authors:
Yann Lai-Tim,
Laurent M. Mugnier,
François Orieux,
Roberto Baena-Gallé,
Michel Paques,
Serge Meimon
Abstract:
Structured Illumination Microscopy (SIM) is an imaging technique for achieving both super-resolution (SR) and optical sectioning (OS) in wide-field microscopy. It consists in illuminating the sample with periodic patterns at different orientations and positions. The resulting images are then processed to reconstruct the observed object with SR and/or OS. In this work, we present BOSSA-SIM, a gener…
▽ More
Structured Illumination Microscopy (SIM) is an imaging technique for achieving both super-resolution (SR) and optical sectioning (OS) in wide-field microscopy. It consists in illuminating the sample with periodic patterns at different orientations and positions. The resulting images are then processed to reconstruct the observed object with SR and/or OS. In this work, we present BOSSA-SIM, a general-purpose SIM reconstruction method, applicable to moving objects such as encountered in in vivo retinal imaging, that enables SR and OS jointly in a fully unsupervised Bayesian framework. By modeling a 2-layer object composed of an in-focus layer and a defocused layer, we show that BOSSA-SIM is able to jointly reconstruct them so as to get a super-resolved and optically sectioned in-focus layer. The achieved performance, assessed quantitatively by simulations for several noise levels, compares favorably with a state-of-the-art method. Finally, we validate our method on open-access experimental microscopy data.
△ Less
Submitted 17 October, 2019; v1 submitted 15 October, 2019;
originally announced October 2019.
-
Experience with wavefront sensor and deformable mirror interfaces for wide-field adaptive optics systems
Authors:
A. G. Basden,
D. Atkinson,
N. A. Bharmal,
U. Bitenc,
M. Brangier,
T. Buey,
T. Butterley,
D. Cano,
F. Chemla,
P. Clark,
M. Cohen,
J. -M. Conan,
F. J. de Cos,
C. Dickson,
N. A. Dipper,
C. N. Dunlop,
P. Feautrier,
T. Fusco,
J. L. Gach,
E. Gendron,
D. Geng,
S. J. Goodsell,
D. Gratadour,
A. H. Greenaway,
A. Guesalaga
, et al. (34 additional authors not shown)
Abstract:
Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs).
Here, we report on our experience integrating cameras and DMs with the real-time c…
▽ More
Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs).
Here, we report on our experience integrating cameras and DMs with the real-time control systems of two wide-field AO systems. These are CANARY, which has been operating on-sky since 2010, and DRAGON, which is a laboratory adaptive optics real-time demonstrator instrument. We detail the issues and difficulties that arose, along with the solutions we developed. We also provide recommendations for consideration when develo** future wide-field AO systems.
△ Less
Submitted 24 March, 2016;
originally announced March 2016.
-
Imaging the spotty surface of Betelgeuse in the H band
Authors:
X. Haubois,
G. Perrin,
S. Lacour,
T. Verhoelst,
S. Meimon,
L. Mugnier,
E. Thiebaut,
J. P. Berger,
S. T. Ridgway,
J. D. Monnier,
R. Millan-Gabet,
W. Traub
Abstract:
This paper reports on H-band interferometric observations of Betelgeuse made at the three-telescope interferometer IOTA. We image Betelgeuse and its asymmetries to understand the spatial variation of the photosphere, including its diameter, limb darkening, effective temperature, surrounding brightness, and bright (or dark) star spots. We used different theoretical simulations of the photosphere…
▽ More
This paper reports on H-band interferometric observations of Betelgeuse made at the three-telescope interferometer IOTA. We image Betelgeuse and its asymmetries to understand the spatial variation of the photosphere, including its diameter, limb darkening, effective temperature, surrounding brightness, and bright (or dark) star spots. We used different theoretical simulations of the photosphere and dusty environment to model the visibility data. We made images with parametric modeling and two image reconstruction algorithms: MIRA and WISARD. We measure an average limb-darkened diameter of 44.28 +/- 0.15 mas with linear and quadratic models and a Rosseland diameter of 45.03 +/- 0.12 mas with a MARCS model. These measurements lead us to derive an updated effective temperature of 3600 +/- 66 K. We detect a fully-resolved environment to which the silicate dust shell is likely to contribute. By using two imaging reconstruction algorithms, we unveiled two bright spots on the surface of Betelgeuse. One spot has a diameter of about 11 mas and accounts for about 8.5% of the total flux. The second one is unresolved (diameter < 9 mas) with 4.5% of the total flux. Resolved images of Betelgeuse in the H band are asymmetric at the level of a few percent. The MOLsphere is not detected in this wavelength range. The amount of measured limb-darkening is in good agreement with model predictions. The two spots imaged at the surface of the star are potential signatures of convective cells.
△ Less
Submitted 9 November, 2009; v1 submitted 21 October, 2009;
originally announced October 2009.
-
The Pulsation of Chi Cygni Imaged by Optical Interferometry; a Novel Technique to Derive Distance and Mass of Mira Stars
Authors:
S. Lacour,
E. Thiébaut,
G. Perrin,
S. Meimon,
X. Haubois,
E. Pedretti,
S. Ridgway,
J. D. Monnier,
J. P. Berger,
P. A. Schuller,
H. Woodruff,
A. Poncelet,
H. Le Coroller,
R. Millan-Gabet,
M. Lacasse,
W. Traub
Abstract:
We present infrared interferometric imaging of the S-type Mira star Chi Cygni. The object was observed at four different epochs in 2005-2006 with the IOTA optical interferometer (H band). Images show up to 40% variation in the stellar diameter, as well as significant changes in the limb darkening and stellar inhomogeneities. Model fitting gave precise time-dependent values of the stellar diamete…
▽ More
We present infrared interferometric imaging of the S-type Mira star Chi Cygni. The object was observed at four different epochs in 2005-2006 with the IOTA optical interferometer (H band). Images show up to 40% variation in the stellar diameter, as well as significant changes in the limb darkening and stellar inhomogeneities. Model fitting gave precise time-dependent values of the stellar diameter, and reveals presence and displacement of a warm molecular layer. The star radius, corrected for limb darkening, has a mean value of 12.1 mas and shows a 5.1mas amplitude pulsation. Minimum diameter was observed at phase 0.94+/-0.01. Maximum temperature was observed several days later at phase 1.02+/-0.02. We also show that combining the angular acceleration of the molecular layer with CO (Delta v = 3) radial velocity measurements yields a 5.9+/-1.5 mas parallax. The constant acceleration of the CO molecules -- during 80% of the pulsation cycle -- lead us to argument for a free-falling layer. The acceleration is compatible with a gravitational field produced by a 2.1(+1.5/-0.7) solar mass star. This last value is in agreement with fundamental mode pulsator models. We foresee increased development of techniques consisting in combining radial velocity with interferometric angular measurements, ultimately allowing total map** of the speed, density, and position of the diverse species in pulsation driven atmospheres.
△ Less
Submitted 20 October, 2009;
originally announced October 2009.
-
A self-calibration approach for optical long baseline interferometry imaging
Authors:
Serge Meimon,
Laurent M. Mugnier,
Guy Le Besnerais
Abstract:
Current optical interferometers are affected by unknown turbulent phases on each telescope. In the field of radio-interferometry, the self-calibration technique is a powerful tool to process interferometric data with missing phase information. This paper intends to revisit the application of self-calibration to Optical Long Baseline Interferometry (OLBI). We cast rigorously the OLBI data process…
▽ More
Current optical interferometers are affected by unknown turbulent phases on each telescope. In the field of radio-interferometry, the self-calibration technique is a powerful tool to process interferometric data with missing phase information. This paper intends to revisit the application of self-calibration to Optical Long Baseline Interferometry (OLBI). We cast rigorously the OLBI data processing problem into the self-calibration framework and demonstrate the efficiency of the method on real astronomical OLBI dataset.
△ Less
Submitted 5 December, 2008;
originally announced December 2008.
-
The limb-darkened Arcturus; Imaging with the IOTA/IONIC interferometer
Authors:
S. Lacour,
S. Meimon,
E. Thiebaut,
G. Perrin,
T. Verhoelst,
E. Pedretti,
P. A. Schuller,
L. Mugnier,
J. Monnier,
J. P. Berger,
X. Haubois,
A. Poncelet,
G. Le Besnerais,
K. Eriksson,
R. Millan-Gabet,
M. Lacasse,
W. Traub
Abstract:
This paper is an H band interferometric examination of Arcturus, a star frequently used as a spatial and spectral calibrator. Using the IOTA 3 telescope interferometer, we performed spectro-interferometric observation (R~35) of Arcturus. Atmospheric models and prescriptions were fitted to the data to derive the brightness distribution of the photosphere. Image reconstruction was also obtained us…
▽ More
This paper is an H band interferometric examination of Arcturus, a star frequently used as a spatial and spectral calibrator. Using the IOTA 3 telescope interferometer, we performed spectro-interferometric observation (R~35) of Arcturus. Atmospheric models and prescriptions were fitted to the data to derive the brightness distribution of the photosphere. Image reconstruction was also obtained using two software algorithms: Wisard and Mira. An achromatic power law proved to be a good model of the brightness distribution, with a limb darkening compatible with the one derived from atmospheric model simulations using our Marcs model. A Rosseland diameter of 21.05+/-0.21 was derived, corresponding to an effective temperature of T_eff=4295+/-26 K. No companion was detected from the closure phases, with an upper limit on the brightness ratio of 8e-4 at 1AU. Dynamic range at such distance from the photosphere was established at 1.5e-4 (1sigma rms). An upper limit of 1.7e-3 was also derived for the level of brightness asymmetries present on the photosphere.
△ Less
Submitted 1 April, 2008;
originally announced April 2008.