Background: The development of smart nanocarriers that enable controlled drug release in response to internal and external triggers is an emerging approach for targeted therapy. This study focused on designing pH-sensitive, ultrasound-responsive gelatin/perfluorohexane (PFH) nanodroplets loaded with berberine chloride as a model drug. Results:The nanodroplets were prepared using an emulsion techni…
▽ More
Background: The development of smart nanocarriers that enable controlled drug release in response to internal and external triggers is an emerging approach for targeted therapy. This study focused on designing pH-sensitive, ultrasound-responsive gelatin/perfluorohexane (PFH) nanodroplets loaded with berberine chloride as a model drug. Results:The nanodroplets were prepared using an emulsion technique and optimized by varying process parameters like homogenization rate, polymer concentration, surfactant, drug, and perfluorocarbon content. The optimal formulation yielded nanodroplets with a particle size of 281.7 nm, a drug encapsulation efficiency of 66.8+- 1.7%, and a passive drug release of 15.4+- 0.2% within 24 hours. Characterization confirmed successful encapsulation and pH-responsive behavior. Ultrasound stimulation significantly enhanced drug release, with 150 kHz being more effective than 1 MHz in triggering acoustic droplet vaporization while minimizing heat generation. After 10 minutes of radiation, the optimal formulation showed 89.4% cumulative drug release. The nanodroplets displayed stability over one month at 4°C. Conclusions: Overall, the dual-triggered nanodroplets demonstrate excellent potential for controlled delivery and targeted release of berberine chloride.
△ Less
Submitted 18 June, 2024; v1 submitted 25 January, 2024;
originally announced January 2024.
-
Analysis and Calibration of Electron-Dispersive Spectroscope and Scanning Electron Microscope Parameters to Improve their Results
Authors:
Hamidreza Moradi,
Fatemeh Mehradnia
Abstract:
The Scanning electron microscope (SEM) and Electron-Dispersive Spectroscope (EDS) are two highly effective instruments in the field of nanoscience and nanotechnology. The quality of these instruments is determined by various factors, with high resolution being a crucial one. To determine the practically achievable resolution of the SEM, reference materials such as gold particles on carbon substrat…
▽ More
The Scanning electron microscope (SEM) and Electron-Dispersive Spectroscope (EDS) are two highly effective instruments in the field of nanoscience and nanotechnology. The quality of these instruments is determined by various factors, with high resolution being a crucial one. To determine the practically achievable resolution of the SEM, reference materials such as gold particles on carbon substrate are commonly utilized. On the other hand, high demanding, and usual materials such as brass, aluminum oxide or MEMs are of high importance to be considered in the way of improving material characterization. In this study five different samples were analyzed in four steps to see the effect of astigmatism and aperture misalignment, the mirror effect on the charged uncoated sample in backscattered electron (BSE) and secondary electron (SE) images, compositional and topographical analysis using both qualitative and quantitative methods and finally apply all the steps on a micro-electromechanical system (MEMS) device. This study illustrates the possibility of controlling the mirror effect by adjusting the input parameters even in the cases that the user needs to have low accelerating voltage for the experiment. Besides, the discussion addresses possible reasons for the absence of some peaks in EDS analysis for some specific elements.
△ Less
Submitted 22 October, 2023;
originally announced October 2023.
-
An analysis on improvement of x-ray diffractometer results by controlling and calibration of parameters
Authors:
Hamidreza Moradi,
Fatemeh Mehradnia
Abstract:
The X-ray diffractometer in the laboratory is a crucial instrument for analyzing materials in science. It can be used on almost any crystal material, and if the machine parameters are appropriately controlled, it can offer a lot of information about the samples characteristics. Nevertheless, the data obtained from these machines are complicated by an aberration function that can be resolved throug…
▽ More
The X-ray diffractometer in the laboratory is a crucial instrument for analyzing materials in science. It can be used on almost any crystal material, and if the machine parameters are appropriately controlled, it can offer a lot of information about the samples characteristics. Nevertheless, the data obtained from these machines are complicated by an aberration function that can be resolved through calibration. In this study, a powder comprising of Barium Sulfate (BaSO4), Zinc Oxide (ZnO) and Aluminum (Al) was used as the first sample and a single crystal sample comprised of Gallium Nitride (GaN) and Aluminum Oxide (Al2O3). The required calibration parameters of the X-ray diffractometer namely: Straight Beam Alignment, Beam Cut Alignment and Sample Tilt Alignment for two samples were analyzed and carried out. Using the results of the X-ray spectrum, important parameters such as corresponding planes for peak positions, d-spacing of planes, intensities, smallest crystallite sizes and lattice parameters, and a comparison with the reference data were all carried out. As another result, the out-of-plane alignment and Full-Width at Half-Maximum (FWHM) value for GaN could be determined using the rocking curve.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.