-
Optimal ROC Curves from Score Variable Threshold Tests
Authors:
Catherine Medlock,
Alan Oppenheim
Abstract:
The Receiver Operating Characteristic (ROC) is a well-established representation of the tradeoff between detection and false alarm probabilities in binary hypothesis testing. In many practical contexts ROC's are generated by thresholding a measured score variable -- applying score variable threshold tests (SVT's). In many cases the resulting curve is different from the likelihood ratio test (LRT)…
▽ More
The Receiver Operating Characteristic (ROC) is a well-established representation of the tradeoff between detection and false alarm probabilities in binary hypothesis testing. In many practical contexts ROC's are generated by thresholding a measured score variable -- applying score variable threshold tests (SVT's). In many cases the resulting curve is different from the likelihood ratio test (LRT) ROC and is therefore not Neyman-Pearson optimal. While it is well-understood that concavity is a necessary condition for an ROC to be Neyman-Pearson optimal, this paper establishes that it is also a sufficient condition in the case where the ROC was generated using SVT's. It further defines a constructive procedure by which the LRT ROC can be generated from a non-concave SVT ROC, without requiring explicit knowledge of the conditional PDF's of the score variable. If the conditional PDF's are known, the procedure implicitly provides a way of redesigning the test so that it is equivalent to an LRT.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
Operating Characteristics for Binary Hypothesis Testing in Quantum Systems
Authors:
Catherine Medlock,
Alan Oppenheim,
Isaac Chuang,
Qi Ding
Abstract:
Receiver operating characteristics (ROCs) are a well-established representation of the tradeoff between detection and false alarm probabilities in classical binary hypothesis testing. We use classical ROCs as motivation for two types of operating characteristics for binary hypothesis testing in quantum systems -- decision operating characteristics (QDOCs) and measurement operating characteristics…
▽ More
Receiver operating characteristics (ROCs) are a well-established representation of the tradeoff between detection and false alarm probabilities in classical binary hypothesis testing. We use classical ROCs as motivation for two types of operating characteristics for binary hypothesis testing in quantum systems -- decision operating characteristics (QDOCs) and measurement operating characteristics (QMOCs). Both are described in the context of a framework we propose that encompasses the typical formulations of binary hypothesis testing in both the classical and quantum scenarios. We interpret Helstrom's well-known result regarding discrimination between two quantum density operators with minimum probability of error in this framework. We also present a generalization of previous results regarding the correspondence between classical Parseval frames and quantum measurements. The derivation naturally leads to a constructive procedure for generating many different measurements besides Helstrom's optimal measurement, some standard and others non-standard, that achieve minimum probability of error.
△ Less
Submitted 14 December, 2020;
originally announced December 2020.
-
Informationally Overcomplete POVMs for Quantum State Estimation and Binary Detection
Authors:
Catherine Medlock,
Alan Oppenheim,
Petros Boufounos
Abstract:
It is well-known in classical frame theory that overcomplete representations of a given vector space provide robustness to additive noise on the frame coefficients of an unknown vector. We describe how the same robustness can be shown to exist in the context of quantum state estimation. A key element of the discussion is the application of classical frame theory to operator-valued vector spaces, o…
▽ More
It is well-known in classical frame theory that overcomplete representations of a given vector space provide robustness to additive noise on the frame coefficients of an unknown vector. We describe how the same robustness can be shown to exist in the context of quantum state estimation. A key element of the discussion is the application of classical frame theory to operator-valued vector spaces, or operator spaces, which arise naturally in quantum mechanics. Specifically, in the problem we describe the frame vectors are represented by the elements of an informationally complete or overcomplete (IC or IOC) POVM, the frame coefficients are represented by the outcome probabilities of a quantum measurement made on an unknown state, and the error on the frame coefficients arises from finite sample size estimations of the probabilities. We show that with this formulation of the problem, there is a tradeoff in estimation performance between the number of copies of the unknown system and the number of POVM elements. Lastly, we present evidence through simulation that the same tradeoff is present in the context of quantum binary state detection -- the probability of error can be reduced either by increasing the number of copies of the unknown system or by increasing the number of POVM elements.
△ Less
Submitted 9 December, 2020;
originally announced December 2020.
-
Beam Imaging and Luminosity Calibration
Authors:
Markus Klute,
Catherine Medlock,
Jakob Salfeld-Nebgen
Abstract:
We discuss a method to reconstruct two-dimensional proton bunch densities using vertex distributions accumulated during LHC beam-beam scans. The $x$-$y$ correlations in the beam shapes are studied and an alternative luminosity calibration technique is introduced. We demonstrate the method on simulated beam-beam scans and estimate the uncertainty on the luminosity calibration associated to the beam…
▽ More
We discuss a method to reconstruct two-dimensional proton bunch densities using vertex distributions accumulated during LHC beam-beam scans. The $x$-$y$ correlations in the beam shapes are studied and an alternative luminosity calibration technique is introduced. We demonstrate the method on simulated beam-beam scans and estimate the uncertainty on the luminosity calibration associated to the beam-shape reconstruction to be below 1\%.
△ Less
Submitted 9 April, 2019; v1 submitted 11 March, 2016;
originally announced March 2016.