A Field-Mill Proxy Climatology for the Lightning Launch Commit Criteria at Cape Canaveral Air Force Station and NASA Kennedy Space Center
Authors:
Shane Gardner,
Edward White,
Brent Langhals,
Todd McNamara,
William Roeder,
Alfred E. Thal Jr
Abstract:
The Lightning Launch Commit Criteria (LLCC) are a set of complex rules to avoid natural and rocket-triggered lightning strikes to in-flight space launch vehicles. The LLCC are the leading source of scrubs and delays to space launches from Cape Canaveral Air Force Station (CCAFS) and NASA Kennedy Space Center (KSC). An LLCC climatology would be useful for designing launch concept of operations, mis…
▽ More
The Lightning Launch Commit Criteria (LLCC) are a set of complex rules to avoid natural and rocket-triggered lightning strikes to in-flight space launch vehicles. The LLCC are the leading source of scrubs and delays to space launches from Cape Canaveral Air Force Station (CCAFS) and NASA Kennedy Space Center (KSC). An LLCC climatology would be useful for designing launch concept of operations, mission planning, long-range forecasting, training, and setting LLCC improvement priorities. Unfortunately, an LLCC climatology has not been available for CCAFS/KSC. Attempts have been made to develop such a climatology, but they have not been entirely successful. The main shortfall has been the lack of a long continuous record of LLCC evaluations. Even though CCAFS/KSC is the world's busiest spaceport, the record of LLCC evaluations is not detailed enough to create the climatology. As a potential solution, the research in this study developed a proxy climatology of LLCC violations by using the long continuous record of surface electric field mills at CCAFS/KSC.
△ Less
Submitted 9 March, 2024;
originally announced March 2024.
-
Actionable Three-Phase Infeasibility Optimization with Varying Slack Sources
Authors:
Elizabeth Foster,
Timothy McNamara,
Amritanshu Pandey,
Larry Pileggi
Abstract:
Modern distribution grids that include numerous distributed energy resources (DERs) and battery electric vehicles (BEVs) will require simulation and optimization methods that can capture behavior under infeasible operating scenarios to assess reliability. A three-phase infeasibility analysis (TPIA) localizes and identifies power deficient areas in distribution feeders via a non-convex optimization…
▽ More
Modern distribution grids that include numerous distributed energy resources (DERs) and battery electric vehicles (BEVs) will require simulation and optimization methods that can capture behavior under infeasible operating scenarios to assess reliability. A three-phase infeasibility analysis (TPIA) localizes and identifies power deficient areas in distribution feeders via a non-convex optimization that injects and subsequently minimizes slack sources, subject to AC network constraints. In this paper, we extend the TPIA framework by introducing operational bounds to ensure realistic, actionable solutions. We incorporate current, reactive power, and susceptance slack sources to model real-world assets, and discuss their potential use cases.
We show that the voltage-bounded TPIA formulations provide actionable solutions for realistic networks of up to 5360 nodes where power flow simulations either fail or return low-voltage solutions. We demonstrate reactive power compensation using the slack susceptance formulation on an infeasible test case.
△ Less
Submitted 16 February, 2023; v1 submitted 6 December, 2022;
originally announced December 2022.
-
Two-Stage Homotopy Method to Incorporate Discrete Control Variables into AC-OPF
Authors:
Timothy McNamara,
Amritanshu Pandey,
Aayushya Agarwal,
Larry Pileggi
Abstract:
Alternating-Current Optimal Power Flow (AC-OPF) is an optimization problem critical for planning and operating the power grid. The problem is traditionally formulated using only continuous variables. Typically, control devices with discrete-valued settings, which provide valuable flexibility to the network and improve resilience, are omitted from AC-OPF formulations due to the difficulty of integr…
▽ More
Alternating-Current Optimal Power Flow (AC-OPF) is an optimization problem critical for planning and operating the power grid. The problem is traditionally formulated using only continuous variables. Typically, control devices with discrete-valued settings, which provide valuable flexibility to the network and improve resilience, are omitted from AC-OPF formulations due to the difficulty of integrality constraints. We propose a two-stage homotopy algorithm to solve the AC-OPF problem with discrete-valued control settings. This method does not rely on prior knowledge of control settings or other initial conditions. The first stage relaxes the discrete settings to continuous variables and solves the optimization using a robust homotopy technique. Once the solution has been obtained using relaxed models, second homotopy problem gradually transforms the relaxed settings to their nearest feasible discrete values. We test the proposed algorithm on several large networks with switched shunts and adjustable transformers and show it can outperform a similar state-of-the-art solver.
△ Less
Submitted 14 October, 2021;
originally announced October 2021.