-
Python for Smarter Cities: Comparison of Python libraries for static and interactive visualisations of large vector data
Authors:
Gregor Herda,
Robert McNabb
Abstract:
Local governments, as part of 'smart city' initiatives and to promote interoperability, are increasingly incorporating open-source software into their data management, analysis, and visualisation workflows. Python, with its concise and natural syntax, presents a low barrier to entry for municipal staff without computer science backgrounds. However, with regard to geospatial visualisations in parti…
▽ More
Local governments, as part of 'smart city' initiatives and to promote interoperability, are increasingly incorporating open-source software into their data management, analysis, and visualisation workflows. Python, with its concise and natural syntax, presents a low barrier to entry for municipal staff without computer science backgrounds. However, with regard to geospatial visualisations in particular, the range of available Python libraries has diversified to such an extent that identifying candidate libraries for specific use cases is a challenging undertaking. This study therefore assesses prominent, actively-developed visualisation libraries in the Python ecosystem with respect to their suitability for producing visualisations of large vector datasets. A simple visualisation task common in urban development is used to produce near-identical thematic maps across static and an interactive 'tracks' of comparison. All short-listed libraries were able to generate the sample map products for both a small and larger dataset. Code complexity differed more strongly for interactive visualisations. Formal and informal documentation channels are highlighted to outline available resources for flattening learning curves. CPU runtimes for the Python-based portion of the process chain differed starkly for both tracks, pointing to avenues for further research. These results demonstrate that the Python ecosystem offers local governments powerful tools, free of vendor lock-in and licensing fees, to produce performant and consistently formatted visualisations for both internal and public distribution.
△ Less
Submitted 26 February, 2022;
originally announced February 2022.
-
Computational 3D microscopy with optical coherence refraction tomography
Authors:
Kevin C. Zhou,
Ryan P. McNabb,
Ruobing Qian,
Simone Degan,
Al-Hafeez Dhalla,
Sina Farsiu,
Joseph A. Izatt
Abstract:
Optical coherence tomography (OCT) has seen widespread success as an in vivo clinical diagnostic 3D imaging modality, impacting areas including ophthalmology, cardiology, and gastroenterology. Despite its many advantages, such as high sensitivity, speed, and depth penetration, OCT suffers from several shortcomings that ultimately limit its utility as a 3D microscopy tool, such as its pervasive coh…
▽ More
Optical coherence tomography (OCT) has seen widespread success as an in vivo clinical diagnostic 3D imaging modality, impacting areas including ophthalmology, cardiology, and gastroenterology. Despite its many advantages, such as high sensitivity, speed, and depth penetration, OCT suffers from several shortcomings that ultimately limit its utility as a 3D microscopy tool, such as its pervasive coherent speckle noise and poor lateral resolution required to maintain millimeter-scale imaging depths. Here, we present 3D optical coherence refraction tomography (OCRT), a computational extension of OCT which synthesizes an incoherent contrast mechanism by combining multiple OCT volumes, acquired across two rotation axes, to form a resolution-enhanced, speckle-reduced, refraction-corrected 3D reconstruction. Our label-free computational 3D microscope features a novel optical design incorporating a parabolic mirror to enable the capture of 5D plenoptic datasets, consisting of millimetric 3D fields of view over up to $\pm75^\circ$ without moving the sample. We demonstrate that 3D OCRT reveals 3D features unobserved by conventional OCT in fruit fly, zebrafish, and mouse samples.
△ Less
Submitted 23 February, 2022;
originally announced February 2022.
-
High-speed multiview imaging approaching 4pi steradians using conic section mirrors: theoretical and practical considerations
Authors:
Kevin C. Zhou,
Al-Hafeez Dhalla,
Ryan P. McNabb,
Ruobing Qian,
Sina Farsiu,
Joseph A. Izatt
Abstract:
Illuminating or imaging samples from a broad angular range is essential in a wide variety of computational 3D imaging and resolution-enhancement techniques, such as optical projection tomography (OPT), optical diffraction tomography (ODT), synthetic aperture microscopy, Fourier ptychographic microscopy (FPM), structured illumination microscopy (SIM), photogrammetry, and optical coherence refractio…
▽ More
Illuminating or imaging samples from a broad angular range is essential in a wide variety of computational 3D imaging and resolution-enhancement techniques, such as optical projection tomography (OPT), optical diffraction tomography (ODT), synthetic aperture microscopy, Fourier ptychographic microscopy (FPM), structured illumination microscopy (SIM), photogrammetry, and optical coherence refraction tomography (OCRT). The wider the angular coverage, the better the resolution enhancement or 3D resolving capabilities. However, achieving such angular ranges is a practical challenge, especially when approaching plus-or-minus 90 degrees or beyond. Often, researchers resort to expensive, proprietary high numerical aperture (NA) objectives, or to rotating the sample or source-detector pair, which sacrifices temporal resolution or perturbs the sample. Here, we propose several new strategies for multi-angle imaging approaching 4pi steradians using concave parabolic or ellipsoidal mirrors and fast, low rotational inertia scanners, such as galvanometers. We derive theoretically and empirically relations between a variety of system parameters (e.g., NA, wavelength, focal length, telecentricity) and achievable fields of view (FOVs) and importantly show that intrinsic tilt aberrations do not restrict FOV for many multi-view imaging applications, contrary to conventional wisdom. Finally, we present strategies for avoiding spherical aberrations at obliquely illuminated flat boundaries. Our simple designs allow for high-speed multi-angle imaging for microscopic, mesoscopic, and macroscopic applications.
△ Less
Submitted 17 November, 2021; v1 submitted 30 June, 2021;
originally announced June 2021.
-
In Vivo Quantitative Analysis of Anterior Chamber White Blood Cell Mixture Composition Using Spectroscopic Optical Coherence Tomography
Authors:
Ruobing Qian,
Ryan P. McNabb,
Kevin C. Zhou,
Hazem M. Mousa,
Daniel R. Saban,
Victor L. Perez,
Anthony N. Kuo,
Joseph A. Izatt
Abstract:
Anterior uveitis is the most common form of intraocular inflammation, and one of its main signs is the presence of white blood cells (WBCs) in the anterior chamber (AC). Clinically, the true composition of cells can currently only be obtained using AC paracentesis, an invasive procedure to obtain AC fluid requiring needle insertion into the AC. We previously developed a spectroscopic optical coher…
▽ More
Anterior uveitis is the most common form of intraocular inflammation, and one of its main signs is the presence of white blood cells (WBCs) in the anterior chamber (AC). Clinically, the true composition of cells can currently only be obtained using AC paracentesis, an invasive procedure to obtain AC fluid requiring needle insertion into the AC. We previously developed a spectroscopic optical coherence tomography (SOCT) analysis method to differentiate between populations of RBCs and subtypes of WBCs, including granulocytes, lymphocytes and monocytes, both in vitro and in ACs of excised porcine eyes. We have shown that different types of WBCs have distinct characteristic size distributions, extracted from the backscattered reflectance spectrum of individual cells using Mie theory. Here, we further develop our method to estimate the composition of blood cell mixtures, both in vitro and in vivo. To do so, we estimate the size distribution of unknown cell mixtures by fitting the distribution observed using SOCT with a weighted combination of reference size distributions of each WBC type calculated using kernel density estimation. We validate the accuracy of our estimation in an in vitro study, by comparing our results for a given WBC sample mixture with the cellular concentrations measured by a hemocytometer and SOCT images before mixing. We also conducted a small in vivo quantitative cell mixture validation pilot study which demonstrates congruence between our method and AC paracentesis in two patients with uveitis. The SOCT based method appears promising to provide quantitative diagnostic information of cellular responses in the ACs of patients with uveitis.
△ Less
Submitted 11 January, 2021;
originally announced January 2021.
-
Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
Authors:
V. Tishchenko,
S. Battu,
R. M. Carey,
D. B. Chitwood,
J. Crnkovic,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
Z. Hartwig,
D. W. Hertzog,
B. Johnson,
P. Kammel,
B. Kiburg,
S. Kizilgul,
J. Kunkle,
B. Lauss,
I. Logashenko,
K. R. Lynch,
R. McNabb,
J. P. Miller,
F. Mulhauser
, et al. (8 additional authors not shown)
Abstract:
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target wi…
▽ More
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x 10^{12} positrons were accumulated and together the data yield a muon lifetime of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision
Authors:
D. M. Webber,
V. Tishchenko,
Q. ~Peng,
S. Battu,
R. M. Carey,
D. B. Chitwood,
J. Crnkovic,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
Z. Hartwig,
D. W. Hertzog,
B. Johnson,
P. Kammel,
B. Kiburg,
S. Kizilgul,
J. Kunkle,
B. Lauss,
I. Logashenko,
K. R. Lynch,
R. McNabb
, et al. (8 additional authors not shown)
Abstract:
We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stop** target configurations were employed in independent data-taking periods. The c…
▽ More
We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stop** target configurations were employed in independent data-taking periods. The combined results give tau_{mu^+}(MuLan) = 2196980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: G_F(MuLan) = 1.1663788 (7) x 10^-5 GeV^-2 (0.6 ppm). It is also used to extract the mu^-p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g_P.
△ Less
Submitted 6 December, 2010; v1 submitted 5 October, 2010;
originally announced October 2010.
-
A Tungsten / Scintillating Fiber Electromagnetic Calorimeter Prototype for a High-Rate Muon g-2 Experiment
Authors:
R. McNabb,
J. Blackburn,
J. D. Crnkovic,
D. W. Hertzog,
B. Kiburg,
J. Kunkle,
E. Thorsland,
D. M. Webber,
K. R. Lynch
Abstract:
A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten plates and 0.5-mm-diameter plastic scintillating fiber ribbons. This geometry leads to a detector having a calculated radiation length of 0.69 cm, a Moliere ra…
▽ More
A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten plates and 0.5-mm-diameter plastic scintillating fiber ribbons. This geometry leads to a detector having a calculated radiation length of 0.69 cm, a Moliere radius of 1.73 cm, and a measured intrinsic sampling resolution term of (11.8\pm1.1)/\sqrt{E(GeV)}, in the range 1.5 to 3.5 GeV. The construction procedure, test beam results, and GEANT-4 comparative simulations are described.
△ Less
Submitted 5 October, 2009;
originally announced October 2009.
-
An Improved Limit on the Muon Electric Dipole Moment
Authors:
G. W. Bennett,
B. Bousquet,
H. N. Brown,
G. Bunce,
R. M. Carey,
P. Cushman,
G. T. Danby,
P. T. Debevec,
M. Deile,
H. Deng,
W. Deninger,
S. K. Dhawan,
V. P. Druzhinin,
L. Duong,
E. Efstathiadis,
F. J. M. Farley,
G. V. Fedotovich,
S. Giron,
F. E. Gray,
D. Grigoriev,
M. Grosse-Perdekamp,
A. Grossmann,
M. F. Hare,
D. W. Hertzog,
X. Huang
, et al. (51 additional authors not shown)
Abstract:
Three independent searches for an electric dipole moment (EDM) of the positive and negative muons have been performed, using spin precession data from the muon g-2 storage ring at Brookhaven National Laboratory. Details on the experimental apparatus and the three analyses are presented. Since the individual results on the positive and negative muon, as well as the combined result, d=-0.1(0.9)E-1…
▽ More
Three independent searches for an electric dipole moment (EDM) of the positive and negative muons have been performed, using spin precession data from the muon g-2 storage ring at Brookhaven National Laboratory. Details on the experimental apparatus and the three analyses are presented. Since the individual results on the positive and negative muon, as well as the combined result, d=-0.1(0.9)E-19 e-cm, are all consistent with zero, we set a new muon EDM limit, |d| < 1.9E-19 e-cm (95% C.L.). This represents a factor of 5 improvement over the previous best limit on the muon EDM.
△ Less
Submitted 26 July, 2009; v1 submitted 7 November, 2008;
originally announced November 2008.
-
Improved Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
Authors:
MuLan Collaboration,
D. B. Chitwood,
T. I. Banks,
M. J. Barnes,
S. Battu,
R. M. Carey,
S. Cheekatmalla,
S. M. Clayton,
J. Crnkovic,
K. M. Crowe,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
M. Hance,
D. W. Hertzog,
M. F. Hare,
P. Kammel,
B. Kiburg,
J. Kunkle,
B. Lauss,
I. Logashenko
, et al. (16 additional authors not shown)
Abstract:
The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in excellent agreement with the previous world average. The new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F = 1.166371(6) x…
▽ More
The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in excellent agreement with the previous world average. The new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F = 1.166371(6) x 10^-5 GeV^-2 (5 ppm). Additionally, the precision measurement of the positive muon lifetime is needed to determine the nucleon pseudoscalar coupling g_P.
△ Less
Submitted 8 February, 2008; v1 submitted 16 April, 2007;
originally announced April 2007.
-
An Improved Limit on the Electric Dipole Moment of the Muon
Authors:
Ronald McNabb
Abstract:
Data from the muon g-2 experiment at Brookhaven National Lab has been analyzed to search for a muon electric dipole moment(EDM), which would violate parity and time reversal symmetries. An EDM would cause a tilt in the spin precession plane of the muons, resulting in a vertical oscillation in the position of electrons hitting the detectors. No signal has been observed. Based on this analysis, an…
▽ More
Data from the muon g-2 experiment at Brookhaven National Lab has been analyzed to search for a muon electric dipole moment(EDM), which would violate parity and time reversal symmetries. An EDM would cause a tilt in the spin precession plane of the muons, resulting in a vertical oscillation in the position of electrons hitting the detectors. No signal has been observed. Based on this analysis, an improved limit of $2.8 \times 10^{-19} e-cm(95% CL) is set on the muon EDM.
△ Less
Submitted 1 July, 2004;
originally announced July 2004.
-
A New Method For A Sensitive Deuteron EDM Experiment
Authors:
Y. K. Semertzidis,
M. Aoki,
M. Auzinsh,
V. Balakin,
A. Bazhan,
G. W. Bennett,
R. M. Carey,
P. Cushman,
P. T. Debevec,
A. Dudnikov,
F. J. M. Farley,
D. W. Hertzog,
M. Iwasaki,
K. Jungmann,
D. Kawall,
B. Khazin,
I. B. Khriplovich,
B. Kirk,
Y. Kuno,
D. M. Lazarus,
L. B. Leipuner,
V. Logashenko,
K. R. Lynch,
W. J. Marciano,
R. McNabb
, et al. (13 additional authors not shown)
Abstract:
In this paper a new method is presented for particles in storage rings which could reach a statistical sensitivity of 10**(-27) e cm for the deuteron EDM. This implies an improvement of two orders of magnitude over the present best limits on the T-odd nuclear forces ksi parameter.
In this paper a new method is presented for particles in storage rings which could reach a statistical sensitivity of 10**(-27) e cm for the deuteron EDM. This implies an improvement of two orders of magnitude over the present best limits on the T-odd nuclear forces ksi parameter.
△ Less
Submitted 26 August, 2003;
originally announced August 2003.