Skip to main content

Showing 1–19 of 19 results for author: McGee, M

.
  1. arXiv:2401.04841  [pdf, other

    stat.ME

    Analysis of Compositional Data with Positive Correlations among Components using a Nested Dirichlet Distribution with Application to a Morris Water Maze Experiment

    Authors: Jacob A. Turner, Bianca A. Luedeker, Monnie McGee

    Abstract: In a typical Morris water maze experiment, a mouse is placed in a circular water tank and allowed to swim freely until it finds a platform, triggering a route of escape from the tank. For reference purposes, the tank is divided into four quadrants: the target quadrant where the trigger to escape resides, the opposite quadrant to the target, and two adjacent quadrants. Several response variables ca… ▽ More

    Submitted 9 January, 2024; originally announced January 2024.

    Comments: 30 pages, 7 figures

  2. arXiv:2310.08719  [pdf, other

    stat.AP

    Measuring Sources of Bias in Diving Competitions

    Authors: Monnie McGee, Gabe Downey, Zachary Berg

    Abstract: We examine bias in diving scores from high school meets. Usually, examination of bias in sports where judges assign subjective scores has been examined in terms of nationalistic bias, where judges award favorable scores to athletes from their own home countries. In this work, bias is defined as difference between the judge's scores for a given meet and the ability of the diver. As a measure of the… ▽ More

    Submitted 12 October, 2023; originally announced October 2023.

    Comments: 11 pages, 6 figures, presented at JSM 2023 Toronto

  3. arXiv:2108.09935  [pdf

    cs.CY

    Information Sources and Anxiety among Refugees in Kenya during COVID-19

    Authors: Matthew A. McGee, Carleen Maitland, Dorothy Njoroge

    Abstract: In the COVID-19 pandemic, refugees' access to information has become increasingly important given the rapid change in the scientific and public health knowledge-base. However, this access is complicated by social distancing requirements that disrupt traditional in-person communication. Many refugees must then rely on alternative information sources to stay informed. Differences in media types and… ▽ More

    Submitted 23 August, 2021; originally announced August 2021.

    Comments: In proceedings of the 1st Virtual Conference on Implications of Information and Digital Technologies for Development, 2021

  4. arXiv:2004.14290  [pdf

    q-bio.TO

    Interstitial cells and neurons respond to variations in hydration

    Authors: Maria P McGee, Michael Morykwas, Mary Kerns, Anirudh Vashisht, Ashok N Hegde, Louis Argenta

    Abstract: Dehydration and brain interstitial fluid alterations associate to cognitive dysfunction. We now explore whether changes in matrix hydration are a possible common signal for modulation of water-transfer rates and neuron function.

    Submitted 27 April, 2020; originally announced April 2020.

  5. arXiv:1912.11740  [pdf, other

    stat.CO stat.ME

    A Simple Correction Procedure for High-Dimensional Generalized Linear Models with Measurement Error

    Authors: Michael Byrd, Monnie McGee

    Abstract: We consider high-dimensional generalized linear models when the covariates are contaminated by measurement error. Estimates from errors-in-variables regression models are well-known to be biased in traditional low-dimensional settings if the error is unincorporated. Such models have recently become of interest when regularizing penalties are added to the estimation procedure. Unfortunately, correc… ▽ More

    Submitted 2 January, 2020; v1 submitted 25 December, 2019; originally announced December 2019.

  6. Accelerator Vacuum Windows: A Review of Past Research and a Strategy for the Development of a New Design for Improved Safety and Longevity for Particle Accelerators

    Authors: C. R. Ader, M. Alvarez, J. S. Batko, R. Campos, M. W. McGee, A. Watts

    Abstract: Vacuum window research continues at Fermilab and this paper will examine cost effective, consistent designs which can have a huge impact on accelerator laboratories in terms of safety and cost. Issues such as the design, materials, analysis, testing and fabrication are addressed, including beam scattering plots and materials cost-benefit analysis and examining different materials which can potenti… ▽ More

    Submitted 6 December, 2019; originally announced December 2019.

    Comments: 4 pages, IPAC 2019

    Report number: FERMILAB-CONF-19-200-AD

  7. arXiv:1907.02241  [pdf, other

    stat.ME

    Bayesian Regularization of Gaussian Graphical Models with Measurement Error

    Authors: Michael Byrd, Linh Nghiem, Monnie McGee

    Abstract: We consider a framework for determining and estimating the conditional pairwise relationships of variables when the observed samples are contaminated with measurement error in high dimensional settings. Assuming the true underlying variables follow a multivariate Gaussian distribution, if no measurement error is present, this problem is often solved by estimating the precision matrix under sparsit… ▽ More

    Submitted 4 July, 2019; originally announced July 2019.

  8. arXiv:1808.07917  [pdf

    physics.acc-ph

    Overview of Fabrication Techniques and Lessons Learned With Accelerator Vacuum Windows

    Authors: C. R. Ader, M. W. McGee, L. E. Nobrega, E. A. Voirin

    Abstract: Vacuum thin windows have been used in Fermilab's accelerators for decades and typically have been overlooked in terms of their criticality and fragility. Vacuum windows allow beam to pass through while creating a boundary between vacuum and air or high vacuum and low vacuum areas. The design of vacuum windows, including Titanium and Beryllium windows, will be discussed as well as fabrication, test… ▽ More

    Submitted 23 August, 2018; originally announced August 2018.

    Comments: 4 pp

    Report number: Fermilab-Conf-18-172-AD

  9. arXiv:1805.02725  [pdf

    physics.acc-ph

    Commissioning And First Results From The Fermilab Cryomodule Test Stand

    Authors: E. R. Harms, M. Awida, C. Baffes, K. Carlson, S. Chandrasekaran, B. Chase, E. Cullerton, J. Edelen, J. Einstein-Curtis, C. Ginsburg, A. Grassellino, B. Hansen, J. Holzbauer, S. Kazakov, T. Khabiboulline, M. Kucera, J. Leibfritz, A. Lunin, D. McDowell, M. McGee, D. Nicklaus, D. Orris, J. Ozelis, J. Patrick, T. Petersen , et al. (12 additional authors not shown)

    Abstract: A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overv… ▽ More

    Submitted 7 May, 2018; originally announced May 2018.

    Comments: 4 pp. Proceedings of LINAC2016, East Lansing, MI, USA

    Report number: Fermilab-Conf-16-744-AD-APC-TD

  10. arXiv:1704.07877  [pdf

    physics.acc-ph

    Cryomodule Test Stand Reduced-Magnetic Support Design At Fermilab

    Authors: M. W. McGee, S. K. Chandrasekaran, A. C. Crawford, E. Harms, J. Leibfritz, G. Wu

    Abstract: In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues du… ▽ More

    Submitted 25 April, 2017; originally announced April 2017.

    Comments: 3 pp

    Report number: Fermilab-Conf-16-150-AD-TD

  11. arXiv:1607.00358  [pdf

    physics.acc-ph

    Investigation of thermal acoustic effects on SRF cavities within CM1 at Fermilab

    Authors: M. W. McGee, E. Harms, A. Klebaner, J. Leibfritz, A. Martinez, Y. Pischalnikov, W. Schappert

    Abstract: Radio Frequency (RF) power studies are in progress following the cryogenic commissioning of Cryomodule #1 (CM1) at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. These studies are complemented by the characterization of thermal acoustic effects on cavity microphonics manifested by apparent noisy boiling of helium involving vapor bubble and liquid vibration. The thermal… ▽ More

    Submitted 1 July, 2016; originally announced July 2016.

    Comments: 3 pp

    Report number: Fermilab-Conf-16-152-AD-TD

  12. arXiv:1607.00308  [pdf

    physics.acc-ph

    Mechanical stability study for Integrable Optics Test Accelerator at Fermilab

    Authors: M. W. McGee, R. Andrews, K. Carlson, J. Leibfritz, L. Nobrega, A. Valishev

    Abstract: The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p+) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device compon… ▽ More

    Submitted 1 July, 2016; originally announced July 2016.

    Comments: 3 pp

    Report number: Fermilab-Conf-16-151-AD

  13. arXiv:1607.00045  [pdf

    physics.acc-ph

    Transport of LCLS-II 1.3 Ghz cryomodule to SLAC

    Authors: M. W. McGee, T. Arkan, T. Peterson, Z. Tang, S. Boo, M. Carrasco, E. Daly, N. Huque

    Abstract: In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These include a prototype built and delivered by each Lab. Another two 3.9 GHz cryomodules will be built, tested and transported by Fermilab to SLAC. Each assembly will be transported ov… ▽ More

    Submitted 30 June, 2016; originally announced July 2016.

    Comments: 3 pp

    Report number: Fermilab-Conf-16-136-AD-TD

  14. arXiv:1502.02014  [pdf

    physics.acc-ph

    Current status of the LBNE neutrino beam

    Authors: Craig Damon Moore, Ken Bourkland, Cory Francis Crowley, Patrick Hurh, James Hylen, Byron Lundberg, Alberto Marchionni, Mike McGee, Nikolai V. Mokhov, Vaia Papadimitriou, Rob Plunkett, Sarah Diane Reitzner, Andrew M Stefanik, Gueorgui Velev, Karlton Williams, Robert Miles Zwaska

    Abstract: The Long Baseline Neutrino Experiment (LBNE) will utilize a neutrino beamline facility located at Fermilab. The facility is designed to aim a beam of neutrinos toward a detector placed in South Dakota. The neutrinos are produced in a three-step process. First, protons from the Main Injector hit a solid target and produce mesons. Then, the charged mesons are focused by a set of focusing horns into… ▽ More

    Submitted 6 February, 2015; originally announced February 2015.

    Comments: 3 pp

    Report number: FERMILAB-CONF-13-121-AD

  15. arXiv:1209.4054  [pdf

    physics.acc-ph

    RF Test Results from Cryomodule 1 at the Fermilab SRF Beam Test Facility

    Authors: E. Harms, K. Carlson, B. Chase, E. Cullerton, A. Hocker, C. Jensen, P. Joireman, A. Klebaner, T. Kubicki, M. Kucera, A. Legan, J. Leibfritz, A. Martinez, M. McGee, S. Nagaitsev, O. Nezhevenko, D. Nicklaus, H. Pfeffer, Y. Pischalnikov, P. Prieto, J. Reid, W. Schappert, V. Tupikov, P. Varghese, J. Branlard

    Abstract: Powered operation of Cryomodule 1 (CM-1) at the Fermilab SRF Beam Test Facility began in late 2010. Since then a series of tests first on the eight individual cavities and then the full cryomodule have been performed. We report on the results of these tests and lessons learned which will have an impact on future module testing at Fermilab.

    Submitted 18 September, 2012; originally announced September 2012.

    Comments: 4 pp. 15th International Conference on RF Superconductivity (SRF2011). 25-29 Jul 2011. Chicago, Illinois, USA

    Report number: FERMILAB-CONF-11-352-AD-TD

  16. arXiv:1209.2443  [pdf

    physics.acc-ph

    Overview of the LBNE Neutrino Beam

    Authors: C. D. Moore, Yun He, Patrick Hurh, James Hylen, Byron Lundberg, Mike McGee, Joel Misek, Nikolai V. Mokhov, Vaia Papadimitriou, Rob Plunkett, Ryan Schultz, Gueorgui Velev, Karlton Williams, Robert Miles Zwaska

    Abstract: The Long Baseline Neutrino Experiment (LBNE) will utilize a neutrino beamline facility located at Fermilab. The facility is designed to aim a beam of neutrinos toward a detector placed at the Deep Underground Science and Engineering Laboratory (DUSEL) in South Dakota. The neutrinos are produced in a three-step process. First, protons from the Main Injector hit a solid target and produce mesons. Th… ▽ More

    Submitted 11 September, 2012; originally announced September 2012.

    Comments: 3 pp. Particle Accelerator, 24th Conference (PAC'11) 2011. 28 Mar - 1 Apr 2011. New York, USA

    Report number: FERMILAB-CONF-11-086-AD

  17. arXiv:1208.2018  [pdf

    physics.acc-ph

    Vibrational measurement for commissioning SRF Accelerator Test Facility at Fermilab

    Authors: M. W. McGee, J. Leibfritz, A. Martinez, Y. Pischalnikov, W. Schappert

    Abstract: The commissioning of two cryomodule components is underway at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. The research at this facility supports the next generation high intensity linear accelerators such as the International Linear Collider (ILC), a new high intensity injector (Project X) and other future machines. These components, Cryomodule #1 (CM1) and Capture… ▽ More

    Submitted 9 August, 2012; originally announced August 2012.

    Comments: 3 pp. Particle Accelerator, 24th Conference (PAC'11) 2011. 28 Mar - 1 Apr 2011. New York, USA

    Report number: FERMILAB-CONF-11-074-AD

  18. arXiv:1207.4460  [pdf

    physics.acc-ph physics.ins-det

    Thermal and structural stability of medium energy target carrier assembly for NOvA at Fermilab

    Authors: M. W. McGee, C. Ader, K. Anderson, J. Hylen, M. Martens

    Abstract: The NOνA project will upgrade the existing Neutrino at Main Injector (NuMI) project beamline at Fermilab to accommodate beam power of 700 kW. The Medium Energy (ME) graphite target assembly is provided through an accord with the State Research Center of Russia Institute for High Energy Physics (IHEP) at Protvino, Russia. The effects of proton beam energy deposition within beamline components are c… ▽ More

    Submitted 18 July, 2012; originally announced July 2012.

    Comments: 4 pp. 1st International Particle Accelerator Conference (IPAC'10). 23-28 May 2010. Kyoto, Japan

    Report number: FERMILAB-CONF-10-129-AD

  19. arXiv:cond-mat/0109001  [pdf, ps, other

    cond-mat.soft physics.bio-ph q-bio.QM

    Surface-dependent Coagulation Enzymes: Flow Kinetics of Factor Xa Generation on Live Membranes

    Authors: Maria P. McGee, Tom Chou

    Abstract: The initial surface reactions of the extrinsic coagulation pathway on live cell membranes were examined under flow conditions. Generation of fXa (activated coagulation factor X) was measured on spherical monolayers of epithelial cells with a total surface area of 41-47 cm$^{2}$ expressing TF(tissue factor) at $>25$ fmol/cm$^{2}$. Concentrations of reactants and product were monitored as a functi… ▽ More

    Submitted 31 August, 2001; originally announced September 2001.

    Comments: 6 .eps figs, 25pp

    Report number: BM-01-02

    Journal ref: J. Biological Chemistry, 276, (2001), 7827-7835