Skip to main content

Showing 1–3 of 3 results for author: McDonald, J E

.
  1. arXiv:1101.1940  [pdf

    physics.ins-det astro-ph.IM astro-ph.SR nucl-ex

    An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS

    Authors: M. Gai, M. W. Ahmed, S. C. Stave, W. R. Zimmerman, A. Breskin, B. Bromberger, R. Chechik, V. Dangendorf, Th. Delbar, R. H. France III, S. S. Henshaw, T. J. Kading, P. P. Martel, J. E. R. McDonald, P. -N. Seo, K. Tittelmeier, H. R. Weller, A. H. Young

    Abstract: We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process o… ▽ More

    Submitted 10 January, 2011; originally announced January 2011.

    Comments: Supported by the Richard F. Goodman Yale-Weizmann Exchange Program, ACWIS, NY, and USDOE grant Numbers: DE-FG02-94ER40870 and DE-FG02-97ER41033

    Journal ref: Published in: JINST 5(2010)12004

  2. arXiv:nucl-ex/0702018  [pdf, ps, other

    nucl-ex astro-ph nucl-th

    A Further Measurement of the beta-Delayed alpha-Particle Emission of 16N

    Authors: R. H. France III, E. L. Wilds, J. E. McDonald, M. Gai

    Abstract: We measured the beta-delayed alpha-particle emission spectrum of 16N with a sensitivity for beta-decay branching ratios of the order of 10-10. The 16N nuclei were produced using the d(15N,16N)p reaction with 70 MeV 15N beams and a deuterium gas target 7.5 cm long at a pressure of 1250 torr. The 16N nuclei were collected (over 10 s) using a thin aluminum foil with an areal density of 180 mu g/cm2… ▽ More

    Submitted 8 February, 2007; originally announced February 2007.

    Comments: Supported by USDOE grants No. DE-FG02-91ER40609 and DE-FG02-94ER40870

    Report number: UConn-40870-0036, GCSU-CBX82-0003

    Journal ref: Phys.Rev.C75:065802,2007

  3. arXiv:nucl-ex/0608027  [pdf, ps, other

    nucl-ex astro-ph physics.ins-det

    In Beam Tests of Implanted Helium Targets

    Authors: J. E. McDonald, R. H. France III, R. A. Jarvis, M. W. Ahmed, M. A. Blackston, Th. Delbar, M. Gai, T. J. Kading, Y. Parpottas, B. A. Perdue, R. M. Prior, D. A. Rubin, M. C. Spraker, J. D. Yeomans, L. Weissman, H. R. Weller, E. L. Wilds Jr, ;, UHartford, GCSU, LNS/UConn, TUNL/Duke, UCL/LLN, Yale, NGCSU

    Abstract: Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. He… ▽ More

    Submitted 16 August, 2006; originally announced August 2006.

    Comments: Submitted to the New Online Journal of Instrumentation, JINST. Work Supported by USDOE Grant Nos: DE-FG02-94ER40870, DE-FG02-91ER40609, DE-FG02-97ER41033, and DE-FG02-97ER41046

    Report number: UConn-40870-XXXX

    Journal ref: JINST 1:P09003,2006