-
Statistical Methods for Investigating the Cosmic Ray Energy Spectrum
Authors:
J. D. Hague,
B. R. Becker,
M. S. Gold,
J. A. J. Matthews,
J. Urbář
Abstract:
Two separate statistical tests are described and developed in order to test un-binned data sets for adherence to the power-law form. The first test employs the TP-statistic, a function defined to deviate from zero when the sample deviates from the power-law form, regardless of the value of the power index. The second test employs a likelihood ratio test to reject a power-law background in favor…
▽ More
Two separate statistical tests are described and developed in order to test un-binned data sets for adherence to the power-law form. The first test employs the TP-statistic, a function defined to deviate from zero when the sample deviates from the power-law form, regardless of the value of the power index. The second test employs a likelihood ratio test to reject a power-law background in favor of a model signal distribution with a cut-off.
△ Less
Submitted 18 October, 2007;
originally announced October 2007.
-
Dedekind-Carlitz Polynomials as Lattice-Point Enumerators in Rational Polyhedra
Authors:
Matthias Beck,
Christian Haase,
Asia R. Matthews
Abstract:
We study higher-dimensional analogs of the Dedekind-Carlitz polynomials c(u,v;a,b) := sum_{k=1..b-1} u^[ka/b] v^(k-1), where u and v are indeterminates and a and b are positive integers. Carlitz proved that these polynomials satisfy the reciprocity law (v-1) c(u,v;a,b) + (u-1) c(v,u;b,a) = u^(a-1) v^(b-1) - 1, from which one easily deduces many classical reciprocity theorems for the Dedekind sum…
▽ More
We study higher-dimensional analogs of the Dedekind-Carlitz polynomials c(u,v;a,b) := sum_{k=1..b-1} u^[ka/b] v^(k-1), where u and v are indeterminates and a and b are positive integers. Carlitz proved that these polynomials satisfy the reciprocity law (v-1) c(u,v;a,b) + (u-1) c(v,u;b,a) = u^(a-1) v^(b-1) - 1, from which one easily deduces many classical reciprocity theorems for the Dedekind sum and its generalizations. We illustrate that Dedekind-Carlitz polynomials appear naturally in generating functions of rational cones and use this fact to give geometric proofs of the Carlitz reciprocity law and various extensions of it. Our approach gives rise to new reciprocity theorems and computational complexity results for Dedekind-Carlitz polynomials, a characterization of Dedekind-Carlitz polynomials in terms of generating functions of lattice points in triangles, and a multivariate generalization of the Mordell-Pommersheim theorem on the appearance of Dedekind sums in Ehrhart polynomials of 3-dimensional lattice polytopes.
△ Less
Submitted 22 February, 2008; v1 submitted 5 October, 2007;
originally announced October 2007.
-
The Absolute, Relative and Multi-Wavelength Calibration of the Pierre Auger Observatory Fluorescence Detectors
Authors:
R. Knapik,
P. Bauleo,
B. R. Becker,
J. Brack,
R. Caruso,
C. Delle Fratte,
A. Dorofeev,
J. Harton,
A. Insolia,
J. A. J. Matthews,
A. Menshikov,
F. Ortolani,
P. Petrinca,
A. Pichel,
S. Riggi,
M. Roberts,
J. Rodriguez Martino,
A. C. Rovero,
M. Scuderi,
A. Tamashiro,
D. Torresi,
V. Tuci,
L. Wiencke
Abstract:
Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a 375 nm light source at the telescope aperture. This end-to-end technique accounts for the combined effects of all detector components in a single measurement. The relative response has been measured at wavelengths of 320, 337, 355, 380 and 405 nm, defining a spectral response curve which has been normalized to the…
▽ More
Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a 375 nm light source at the telescope aperture. This end-to-end technique accounts for the combined effects of all detector components in a single measurement. The relative response has been measured at wavelengths of 320, 337, 355, 380 and 405 nm, defining a spectral response curve which has been normalized to the absolute calibration. Before and after each night of data taking a relative calibration of the phototubes is performed. This relative calibration is used to track both short and long term changes in the detector's response. A cross check of the calibration in some phototubes is performed using an independent laser technique. Overall uncertainties, current results and future plans are discussed.
△ Less
Submitted 14 August, 2007;
originally announced August 2007.
-
Measurement of Aerosols at the Pierre Auger Observatory
Authors:
S. Y. BenZvi,
F. Arqueros,
R. Cester,
M. Chiosso,
B. M. Connolly,
B. Fick,
A. Filipcic,
B. García,
A. Grillo,
F. Guarino,
M. Horvat,
M. Iarlori,
C. Macolino,
M. Malek,
J. Matthews,
J. A. J. Matthews,
D. Melo,
R. Meyhandan,
M. Micheletti,
M. Monasor,
M. Mostafá,
R. Mussa,
J. Pallotta,
S. Petrera,
M. Prouza
, et al. (16 additional authors not shown)
Abstract:
The air fluorescence detectors (FDs) of the Pierre Auger Observatory are vital for the determination of the air shower energy scale. To compensate for variations in atmospheric conditions that affect the energy measurement, the Observatory operates an array of monitoring instruments to record hourly atmospheric conditions across the detector site, an area exceeding 3,000 square km. This paper pr…
▽ More
The air fluorescence detectors (FDs) of the Pierre Auger Observatory are vital for the determination of the air shower energy scale. To compensate for variations in atmospheric conditions that affect the energy measurement, the Observatory operates an array of monitoring instruments to record hourly atmospheric conditions across the detector site, an area exceeding 3,000 square km. This paper presents results from four instruments used to characterize the aerosol component of the atmosphere: the Central Laser Facility (CLF), which provides the FDs with calibrated laser shots; the scanning backscatter lidars, which operate at three FD sites; the Aerosol Phase Function monitors (APFs), which measure the aerosol scattering cross section at two FD locations; and the Horizontal Attenuation Monitor (HAM), which measures the wavelength dependence of aerosol attenuation.
△ Less
Submitted 21 June, 2007;
originally announced June 2007.
-
Measurement of the Aerosol Phase Function at the Pierre Auger Observatory
Authors:
S. Y. BenZvi,
B. M. Connolly,
J. A. J. Matthews,
M. Prouza,
E. F. Visbal,
S. Westerhoff
Abstract:
Air fluorescence detectors measure the energy of ultra-high energy cosmic rays by collecting fluorescence light emitted from nitrogen molecules along the extensive air shower cascade. To ensure a reliable energy determination, the light signal needs to be corrected for atmospheric effects, which not only attenuate the signal, but also produce a non-negligible background component due to scattere…
▽ More
Air fluorescence detectors measure the energy of ultra-high energy cosmic rays by collecting fluorescence light emitted from nitrogen molecules along the extensive air shower cascade. To ensure a reliable energy determination, the light signal needs to be corrected for atmospheric effects, which not only attenuate the signal, but also produce a non-negligible background component due to scattered Cherenkov light and multiple-scattered light. The correction requires regular measurements of the aerosol attenuation length and the aerosol phase function, defined as the probability of light scattered in a given direction. At the Pierre Auger Observatory in Malargue, Argentina, the phase function is measured on an hourly basis using two Aerosol Phase Function (APF) light sources. These sources direct a UV light beam across the field of view of the fluorescence detectors; the phase function can be extracted from the image of the shots in the fluorescence detector cameras. This paper describes the design, current status, standard operation procedure, and performance of the APF system at the Pierre Auger Observatory.
△ Less
Submitted 2 July, 2007; v1 submitted 2 April, 2007;
originally announced April 2007.
-
Power Laws and the Cosmic Ray Energy Spectrum
Authors:
J. D. Hague,
B. R. Becker,
M. S. Gold,
J. A. J. Matthews
Abstract:
Two separate statistical tests are applied to the AGASA and preliminary Auger Cosmic Ray Energy spectra in an attempt to find deviation from a pure power-law. The first test is constructed from the probability distribution for the maximum event of a sample drawn from a power-law. The second employs the TP-statistic, a function defined to deviate from zero when the sample deviates from the power-…
▽ More
Two separate statistical tests are applied to the AGASA and preliminary Auger Cosmic Ray Energy spectra in an attempt to find deviation from a pure power-law. The first test is constructed from the probability distribution for the maximum event of a sample drawn from a power-law. The second employs the TP-statistic, a function defined to deviate from zero when the sample deviates from the power-law form, regardless of the value of the power index. The AGASA data show no significant deviation from a power-law when subjected to both tests. Applying these tests to the Auger spectrum suggests deviation from a power-law. However, potentially large systematics on the relative energy scale prevent us from drawing definite conclusions at this time.
△ Less
Submitted 30 October, 2006;
originally announced October 2006.
-
Search for Correlations between Nearby AGNs and Ultra-high Energy Cosmic Rays
Authors:
J. D. Hague,
J. A. J. Matthews,
B. R. Becker,
M. S. Gold
Abstract:
The majority of the highest energy cosmic rays are thought to be electrically charged: protons or nuclei. Charged particles experience angular deflections as they pass through galactic and extra-galactic magnetic fields. As a consequence correlation of cosmic ray arrival directions with potential sources has proved to be difficult. This situation is not helped by current data samples where the n…
▽ More
The majority of the highest energy cosmic rays are thought to be electrically charged: protons or nuclei. Charged particles experience angular deflections as they pass through galactic and extra-galactic magnetic fields. As a consequence correlation of cosmic ray arrival directions with potential sources has proved to be difficult. This situation is not helped by current data samples where the number of cosmic rays/source are typically < O(1). Progress will be made when there are significantly larger data samples and perhaps with better catalogs of candidate sources. This paper reports a search for correlations between the RXTE catalog of nearby active galactic nuclei, AGNs, and the published list of ultra-high energy cosmic rays from the AGASA experiment. Although no statistically significant correlations were found, two correlations were observed between AGASA events and the most inclusive category of RXTE AGNs.
△ Less
Submitted 31 October, 2006; v1 submitted 24 September, 2006;
originally announced September 2006.
-
The Lidar System of the Pierre Auger Observatory
Authors:
S. Y. BenZvi,
R. Cester,
M. Chiosso,
B. M. Connolly,
A. Filipcic,
B. Garcia,
A. Grillo,
F. Guarino,
M. Horvat,
M. Iarlori,
C. Macolino,
J. A. J. Matthews,
D. Melo,
R. Mussa,
M. Mostafa,
J. Pallota,
S. Petrera,
M. Prouza,
V. Rizi,
M. Roberts,
J. R. Rodriguez Rojo,
F. Salamida,
M. Santander,
G. Sequeiros,
A. Tonachini
, et al. (5 additional authors not shown)
Abstract:
The Pierre Auger Observatory in Malargue, Argentina, is designed to study the origin of ultrahigh energy cosmic rays with energies above 10^18 eV. The energy calibration of the detector is based on a system of four air fluorescence detectors. To obtain reliable calorimetric information from the fluorescence stations, the atmospheric conditions at the experiment's site need to be monitored contin…
▽ More
The Pierre Auger Observatory in Malargue, Argentina, is designed to study the origin of ultrahigh energy cosmic rays with energies above 10^18 eV. The energy calibration of the detector is based on a system of four air fluorescence detectors. To obtain reliable calorimetric information from the fluorescence stations, the atmospheric conditions at the experiment's site need to be monitored continuously during operation. One of the components of the observatory's atmospheric monitoring system is a set of four elastic backscatter lidar stations, one station at each of the fluorescence detector sites. This paper describes the design, current status, standard operation procedure, and performance of the lidar system of the Pierre Auger Observatory.
△ Less
Submitted 31 March, 2007; v1 submitted 3 September, 2006;
originally announced September 2006.
-
Optical Relative Calibration and Stability Monitoring for the Auger Fluorescence Detector
Authors:
Pierre Auger Collaboration,
C. Aramo,
J. Brack,
R. Caruso,
D. D'Urso,
D. Fazio,
R. Fonte,
H. Gemmeke,
M. Kleifges,
R. Knapik,
A. Insolia,
J. A. J. Matthews,
A. Menshikov,
W. Miller,
P. Privitera,
J. Rodriguez Martino
Abstract:
The stability of the fluorescence telescopes of the Pierre Auger Observatory is monitored with the optical relative calibration setup. Optical fibers distribute light pulses to three different diffuser groups within the optical system. The total charge per pulse is measured for each pixel and compared with reference calibration measurements. This allows monitoring the short and long term stabili…
▽ More
The stability of the fluorescence telescopes of the Pierre Auger Observatory is monitored with the optical relative calibration setup. Optical fibers distribute light pulses to three different diffuser groups within the optical system. The total charge per pulse is measured for each pixel and compared with reference calibration measurements. This allows monitoring the short and long term stability with respect of the relative timing between pixels and the relative gain for each pixel. The designs of the LED calibration unit (LCU) and of the Xenon flash lamp used for relative calibration, are described and their capabilities to monitor the stability of the telescope performances are studied. We report the analysis of relative calibration data recorded during 2004. Fluctuations in the relative calibration constants provide a measure of the stability of the FD.
△ Less
Submitted 26 July, 2005; v1 submitted 25 July, 2005;
originally announced July 2005.
-
The Central Laser Facility at the Pierre Auger Observatory
Authors:
F. Arqueros,
J. Bellido,
C. Covault,
D. D'Urso,
C. Di Giulio,
P. Facal,
B. Fick,
F. Guarino,
M. Malek,
J. A. J. Matthews,
J. Matthews,
R. Meyhandan,
M. Monasor,
M. Mostafa,
P. Petrinca,
M. Roberts,
P. Sommers,
P. Travnicek,
L. Valore,
V. Verzi,
L. Wiencke
Abstract:
The Central Laser Facility is located near the middle of the Pierre Auger Observatory in Argentina. It features a UV laser and optics that direct a beam of calibrated pulsed light into the sky. Light scattered from this beam produces tracks in the Auger optical detectors which normally record nitrogen fluorescence tracks from cosmic ray air showers. The Central Laser Facility provides a "test be…
▽ More
The Central Laser Facility is located near the middle of the Pierre Auger Observatory in Argentina. It features a UV laser and optics that direct a beam of calibrated pulsed light into the sky. Light scattered from this beam produces tracks in the Auger optical detectors which normally record nitrogen fluorescence tracks from cosmic ray air showers. The Central Laser Facility provides a "test beam" to investigate properties of the atmosphere and the fluorescence detectors. The laser can send light via optical fiber simultaneously to the nearest surface detector tank for hybrid timing analyses. We describe the facility and show some examples of its many uses.
△ Less
Submitted 13 July, 2005;
originally announced July 2005.
-
Bandgap properties of two-dimensional low-index photonic crystals
Authors:
Aaron Matthews,
Xue-Hua Wang,
Yuri Kivshar,
Min Gu
Abstract:
We study the bandgap properties of two-dimensional photonic crystals created by a lattice of rods or holes conformed in a symmetric or asymmetric triangular structure. Using the plane-wave analysis, we calculate a minimum value of the refractive index contrast for opening both partial and full two-dimensional spectral gaps for both TM and TE polarized waves. We also analyze the effect of ellipti…
▽ More
We study the bandgap properties of two-dimensional photonic crystals created by a lattice of rods or holes conformed in a symmetric or asymmetric triangular structure. Using the plane-wave analysis, we calculate a minimum value of the refractive index contrast for opening both partial and full two-dimensional spectral gaps for both TM and TE polarized waves. We also analyze the effect of ellipticity of rods and holes and their orientation on the threshold value and the relative size of the bandgap.
△ Less
Submitted 14 January, 2005;
originally announced January 2005.
-
Bandgap engineering and defect modes in photonic crystals with rotated hexagonal holes
Authors:
Aaron F. Matthews,
Sergei F. Mingaleev,
Yuri S. Kivshar
Abstract:
We study the bandgap structure of two-dimensional photonic crystals created by a triangular lattice of rotated hexagonal holes, and explore the effects of the reduced symmetry in the unit-cell geometry on the value of the absolute bandgap and the frequencies of localized defect modes. We reveal that a maximum absolute bandgap for this structure is achieved for an intermediate rotation angle of t…
▽ More
We study the bandgap structure of two-dimensional photonic crystals created by a triangular lattice of rotated hexagonal holes, and explore the effects of the reduced symmetry in the unit-cell geometry on the value of the absolute bandgap and the frequencies of localized defect modes. We reveal that a maximum absolute bandgap for this structure is achieved for an intermediate rotation angle of the holes. This angle depends on the radius of the holes and the refractive index of the background material. We also study the properties of the defect modes created by missing holes, and discuss the mode tunability in such structures.
△ Less
Submitted 4 November, 2003;
originally announced November 2003.
-
Induced currents, frozen charges and the quantum Hall effect breakdown
Authors:
K. V. Kavokin,
M. E. Portnoi,
A. J. Matthews,
J. Gething,
A. Usher,
D. A. Ritchie,
M. Y. Simmons
Abstract:
Puzzling results obtained from torque magnetometry in the quantum Hall effect (QHE) regime are presented, and a theory is proposed for their explanation. Magnetic moment saturation, which is usually attributed to the QHE breakdown, is shown to be related to the charge redistribution across the sample.
Puzzling results obtained from torque magnetometry in the quantum Hall effect (QHE) regime are presented, and a theory is proposed for their explanation. Magnetic moment saturation, which is usually attributed to the QHE breakdown, is shown to be related to the charge redistribution across the sample.
△ Less
Submitted 14 October, 2003; v1 submitted 8 July, 2003;
originally announced July 2003.