The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray Detector (SGD)
Authors:
Shin Watanabe,
Hiroyasu Tajima,
Yasushi Fukazawa,
Yuto Ichinohe,
Shin'ichiro Takeda,
Teruaki Enoto,
Taro Fukuyama,
Shunya Furui,
Kei Genba,
Kouichi Hagino,
Astushi Harayama,
Yoshikatsu Kuroda,
Daisuke Matsuura,
Ryo Nakamura,
Kazuhiro Nakazawa,
Hirofumi Noda,
Hirokazu Odaka,
Masayuki Ohta,
Mitsunobu Onishi,
Shinya Saito,
Goro Sato,
Tamotsu Sato,
Tadayuki Takahashi,
Takaaki Tanaka,
Atsushi Togo
, et al. (1 additional authors not shown)
Abstract:
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector sys…
▽ More
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and cadmium telluride (CdTe) sensors. The design of the SGD Compton camera has been finalized and the final prototype, which has the same configuration as the flight model, has been fabricated for performance evaluation. The Compton camera has overall dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel sensors. The detection efficiency of the Compton camera reaches about 15% and 3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed by 208 ASICs developed for the SGD. Good energy resolution is afforded by semiconductor sensors and low noise ASICs, and the obtained energy resolutions with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good background rejection capability due to better constraints on Compton kinematics. Compton camera energy resolutions achieved with the final prototype are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively, which satisfy the instrument requirements for the SGD Compton camera (better than 2%). Moreover, a low intrinsic background has been confirmed by the background measurement with the final prototype.
△ Less
Submitted 2 September, 2015;
originally announced September 2015.
-
Development of the analog ASIC for multi-channel readout X-ray CCD camera
Authors:
Hiroshi Nakajima,
Daisuke Matsuura,
Toshihiro Idehara,
Naohisa Anabuki,
Hiroshi Tsunemi,
John P. Doty,
Hirokazu Ikeda,
Haruyoshi Katayama,
Hisashi Kitamura,
Yukio Uchihori
Abstract:
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that…
▽ More
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of =<30 uV at the pixel rate below 100 kHz. The power consumption is sufficiently low of about 150 mW/chip. The input signal range of 720 mV covers the effective energy range of the typical X-ray photon counting CCD (up to 20 keV). The integrated non-linearity is 0.2% that is similar as those of the conventional CCDs in orbit. We also performed a radiation tolerance test against the total ionizing dose (TID) effect and the single event effect. The irradiation test using 60Co and proton beam showed that the ASIC has the sufficient tolerance against TID up to 200 krad, which absolutely exceeds the expected amount of dose during the period of operating in a low-inclination low-earth orbit. The irradiation of Fe ions with the fluence of 5.2x10^8 Ion/cm2 resulted in no single event latchup (SEL), although there were some possible single event upsets. The threshold against SEL is higher than 1.68 MeV cm^2/mg, which is sufficiently high enough that the SEL event should not be one of major causes of instrument downtime in orbit.
△ Less
Submitted 11 February, 2011;
originally announced February 2011.
-
Development of an n-channel CCD, CCD-NeXT1, for Soft X-ray Imager onboard the NeXT satellite
Authors:
Shin-ichiro Takagi,
Takeshi Go Tsuru,
Tatsuya Inui,
Hironori Matsumoto,
Katsuji Koyama,
Hideki Ozawa,
Masakuni Tohiguchi,
Daisuke Matsuura,
Emi Miyata,
Hiroshi Tsunemi,
Kazuhisa Miyaguchi,
Kentaro Maeda,
Hirohiko Kohno
Abstract:
NeXT (New X-ray Telescope) is the next Japanese X-ray astronomical satellite mission after the Suzaku satellite. NeXT aims to perform wide band imaging spectroscopy. Due to the successful development of a multilayer coated mirror, called a supermirror, NeXT can focus X-rays in the energy range from 0.1 keV up to 80 keV. To cover this wide energy range, we are in the process of develo** a hybri…
▽ More
NeXT (New X-ray Telescope) is the next Japanese X-ray astronomical satellite mission after the Suzaku satellite. NeXT aims to perform wide band imaging spectroscopy. Due to the successful development of a multilayer coated mirror, called a supermirror, NeXT can focus X-rays in the energy range from 0.1 keV up to 80 keV. To cover this wide energy range, we are in the process of develo** a hybrid X-ray camera, Wideband X-ray Imager (WXI) as a focal plane detector of the supermirror. The WXI consists of X-ray CCDs (SXI) and CdTe pixelized detectors (HXI), which cover the lower and higher X-ray energy bands of 0.1-80 keV, respectively. The X-ray CCDs of the SXI are stacked above the CdTe pixelized detectors of the HXI. The X-ray CCDs of the SXI detect soft X-rays below $\sim$ 10 keV and allow hard X-rays pass into the CdTe detectors of the HXI without loss. Thus, we have been develo** a "back-supportless CCD" with a thick depletion layer, a thinned silicon wafer, and a back-supportless structure. In this paper, we report the development and performances of an evaluation model of CCD for the SXI, "CCD-NeXT1". We successfully fabricated two types of CCD-NeXT1, unthinned CCDs with 625-um thick wafer and 150-um thick thinned CCDs. By omitting the polishing process when making the thinned CCDs, we confirmed that the polishing process does not impact the X-ray performance. In addition, we did not find significant differences in the X-ray performance between the two types of CCDs. The energy resolution and readout noise are $\sim$ 140 eV (FWHM) at 5.9 keV and $\sim$5 electrons (RMS), respectively. The estimated thickness of the depletion layer is $\sim$80 um. The performances almost satisfy the requirements of the baseline plan of the SXI.
△ Less
Submitted 3 October, 2007;
originally announced October 2007.
-
Spectral evolution of GRB 060904A observed with Swift and Suzaku -- Possibility of Inefficient Electron Acceleration
Authors:
Daisuke Yonetoku,
Sachiko Tanabe,
Toshio Murakami,
Naomi Emura,
Yuka Aoyama,
Takashi Kidamura,
Hironobu Kodaira,
Yoshiki Kodama,
Ryota Kozaka,
Takuro Nashimoto,
Shinya Okuno,
Satoshi Yokota,
Satoru Yoshinari,
Keiichi Abe,
Kaori Onda,
Makoto S. Tashiro,
Yuji Urata,
Yu** E. Nakagawa,
Satoshi Sugita,
Kazutaka Yamaoka,
Atsumasa Yoshida,
Takuto Ishimura,
Nobuyuki Kawai,
Takashi Shimokawabe,
Kenzo Kinugasa
, et al. (17 additional authors not shown)
Abstract:
We observed an X-ray afterglow of GRB 060904A with the Swift and Suzaku satellites. We found rapid spectral softening during both the prompt tail phase and the decline phase of an X-ray flare in the BAT and XRT data. The observed spectra were fit by power-law photon indices which rapidly changed from $Γ= 1.51^{+0.04}_{-0.03}$ to $Γ= 5.30^{+0.69}_{-0.59}$ within a few hundred seconds in the promp…
▽ More
We observed an X-ray afterglow of GRB 060904A with the Swift and Suzaku satellites. We found rapid spectral softening during both the prompt tail phase and the decline phase of an X-ray flare in the BAT and XRT data. The observed spectra were fit by power-law photon indices which rapidly changed from $Γ= 1.51^{+0.04}_{-0.03}$ to $Γ= 5.30^{+0.69}_{-0.59}$ within a few hundred seconds in the prompt tail. This is one of the steepest X-ray spectra ever observed, making it quite difficult to explain by simple electron acceleration and synchrotron radiation. Then, we applied an alternative spectral fitting using a broken power-law with exponential cutoff (BPEC) model. It is valid to consider the situation that the cutoff energy is equivalent to the synchrotron frequency of the maximum energy electrons in their energy distribution. Since the spectral cutoff appears in the soft X-ray band, we conclude the electron acceleration has been inefficient in the internal shocks of GRB 060904A. These cutoff spectra suddenly disappeared at the transition time from the prompt tail phase to the shallow decay one. After that, typical afterglow spectra with the photon indices of 2.0 are continuously and preciously monitored by both XRT and Suzaku/XIS up to 1 day since the burst trigger time. We could successfully trace the temporal history of two characteristic break energies (peak energy and cutoff energy) and they show the time dependence of $\propto t^{-3} \sim t^{-4}$ while the following afterglow spectra are quite stable. This fact indicates that the emitting material of prompt tail is due to completely different dynamics from the shallow decay component. Therefore we conclude the emission sites of two distinct phenomena obviously differ from each other.
△ Less
Submitted 29 August, 2007;
originally announced August 2007.
-
Performance of the Charge Injection Capability of Suzaku XIS
Authors:
H. Nakajima,
H. Yamaguchi,
H. Matsumoto,
T. G. Tsuru,
K. Koyama,
H. Tsunemi,
K. Hayashida,
K. Torii,
M. Namiki,
S. Katsuda,
M. Shoji,
D. Matsuura,
T. Miyauchi,
T. Dotani,
M. Ozaki,
H. Murakami,
M. W. Bautz,
S. E. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments…
▽ More
A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments using a radiation damaged device, and in-orbit measurements of the XIS. The ground experiments show that charges are stably injected with the dispersion of 91eV in FWHM in a specific column for the charges equivalent to the X-ray energy of 5.1keV. This dispersion width is significantly smaller than that of the X-ray events of 113eV (FWHM) at approximately the same energy. The amount of charge loss during transfer in a specific column, which is measured with the charge injection capability, is consistent with that measured with the calibration source. These results indicate that the charge injection technique can accurately measure column-dependent charge losses rather than the calibration sources. The column-to-column CTI correction to the calibration source spectra significantly reduces the line widths compared to those with a column-averaged CTI correction (from 193eV to 173eV in FWHM on an average at the time of one year after the launch). In addition, this method significantly reduces the low energy tail in the line profile of the calibration source spectrum.
△ Less
Submitted 12 May, 2007;
originally announced May 2007.