Nanosecond time-resolved dual-comb absorption spectroscopy
Authors:
David A. Long,
Matthew J. Cich,
Carl Mathurin,
Adam T. Heiniger,
Garrett C. Mathews,
Augustine Frymire,
Gregory B. Rieker
Abstract:
Frequency combs have revolutionized the field of optical spectroscopy, enabling researchers to probe molecular systems with a multitude of accurate and precise optical frequencies. While there have been tremendous strides in direct frequency comb spectroscopy, these approaches have been unable to record high resolution spectra on the nanosecond timescale characteristic of many physiochemical proce…
▽ More
Frequency combs have revolutionized the field of optical spectroscopy, enabling researchers to probe molecular systems with a multitude of accurate and precise optical frequencies. While there have been tremendous strides in direct frequency comb spectroscopy, these approaches have been unable to record high resolution spectra on the nanosecond timescale characteristic of many physiochemical processes. Here we demonstrate a new approach to optical frequency comb generation in which a pair of electro-optic combs is produced in the near-infrared and subsequently transferred with high mutual coherence and efficiency into the mid-infrared within a single optical parametric oscillator. The high power, mutual coherence, and agile repetition rates of these combs as well as the large mid-infrared absorption of many molecular species enable fully resolved spectral transitions to be recorded in timescales as short as 20 ns. We have applied this approach to study the rapid dynamics occurring within a supersonic pulsed jet, however we note that this method is widely applicable to fields such as chemical and quantum physics, atmospheric chemistry, combustion science, and biology.
△ Less
Submitted 9 November, 2023; v1 submitted 2 December, 2022;
originally announced December 2022.
Cepstral Analysis for Baseline-Insensitive Absorption Spectroscopy Using Light Sources with Pronounced Intensity Variations
Authors:
Christopher S. Goldenstein,
Garrett C. Mathews,
Ryan K. Cole,
Amanda S. Makowiecki,
Gregory B. Rieker
Abstract:
This manuscript presents a data-processing technique which improves the accuracy and precision of absorption-spectroscopy measurements by isolating the molecular absorbance signal from errors in the baseline light intensity (Io) using cepstral analysis. Recently, cepstral analysis has been used with traditional absorption spectrometers to create a modified form of the time-domain molecular free-in…
▽ More
This manuscript presents a data-processing technique which improves the accuracy and precision of absorption-spectroscopy measurements by isolating the molecular absorbance signal from errors in the baseline light intensity (Io) using cepstral analysis. Recently, cepstral analysis has been used with traditional absorption spectrometers to create a modified form of the time-domain molecular free-induction decay (m-FID) signal which can be analyzed independently from Io. However, independent analysis of the molecular signature is not possible when the baseline intensity and molecular response do not separate well in the time domain, which is typical when using injection-current-tuned lasers (e.g., quantum cascade lasers) and other light sources with pronounced intensity tuning. In contrast, the method presented here is applicable to all light sources since it determines gas properties by least-squares fitting a simulated m-FID signal to the measured m-FID signal in the time domain. This method is insensitive to errors in the estimated Io which vary slowly with optical frequency and, therefore, decay rapidly in the time domain. The benefits provided by this method are demonstrated via scanned-wavelength direct-absorption measurements acquired with a distributed-feedback (DFB) quantum-cascade laser (QCL). The wavelength of a DFB QCL was scanned across CO's P(0,20) and P(1,14) absorption transitions at 1 kHz to measure the gas temperature and concentration of CO. Measurements were acquired in a gas cell and in an ethylene-air flame at 1 atm. The measured spectra were processed using the new m-FID-based method and two traditional methods which rely on inferring the baseline error within the spectral-fitting routine. The m-FID-based method demonstrated superior accuracy in all cases and a measurement precision that was 1.5 to 10 times smaller than that provided using traditional methods.
△ Less
Submitted 4 June, 2020;
originally announced June 2020.