Combined 3D PET and Optical Projection Tomography Techniques for Plant Root Phenoty**
Authors:
Qiang Wang,
Sergey Komarov,
Aswin J. Mathews,
Ke Li,
Christopher Topp,
Joseph A. O'Sullivan,
Yuan-Chuan Tai
Abstract:
New imaging techniques are in great demand for investigating underground plant roots systems which play an important role in crop production. Compared with other non-destructive imaging modalities, PET can image plant roots in natural soil and produce dynamic 3D functional images which reveal the temporal dynamics of plant-environment interactions. In this study, we combined PET with optical proje…
▽ More
New imaging techniques are in great demand for investigating underground plant roots systems which play an important role in crop production. Compared with other non-destructive imaging modalities, PET can image plant roots in natural soil and produce dynamic 3D functional images which reveal the temporal dynamics of plant-environment interactions. In this study, we combined PET with optical projection tomography (OPT) to evaluate its potential for plant root phenoty**. We used a dedicated high resolution plant PET imager that has a 14 cm transaxial and 10 cm axial field of views, and multi-bed imaging capability. The image resolution is around 1.25 mm using ML-EM reconstruction algorithm. B73 inbred maize seeds were germinated and then grown in a sealed jar with transparent gel-based media. PET scanning started on the day when the first green leaf appeared, and was carried out once a day for 5 days. Each morning, around 10 mCi of 11CO2 was administrated into a custom built plant labeling chamber. After 10 minutes, residual activity was flushed out with fresh air before a 2-h PET scan started. For the OPT imaging, the jar was placed inside an acrylic cubic container filled with water, illuminated with a uniform surface light source, and imaged by a DSLR camera from 72 angles to acquire optical images for OPT reconstruction. The same plant was imaged 3 times a day by the OPT system. Plant roots growth is measured from the optical images. Co-registered PET and optical images indicate that most of the hot spots appeared in later time points of the PET images correspond to the most actively growing root tips. The strong linear correlation between 11C allocation at root tips measured by PET and eventual root growth measured by OPT suggests that we can use PET as a phenoty** tool to measure how a plant makes subterranean carbon allocation decisions in different environmental scenarios.
△ Less
Submitted 31 December, 2014;
originally announced January 2015.
A dedicated high resolution PET imager for plant sciences
Authors:
Qiang Wang,
Aswin J. Mathews,
Ke Li,
Jie Wen,
Sergey Komarov,
Joseph A. O'Sullivan,
Yuan-Chuan Tai
Abstract:
PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high spatial resolution, housed in a fully controlled environment provided by a plant growth chamber (PGC). The system currently contains two types of detector modules:…
▽ More
PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high spatial resolution, housed in a fully controlled environment provided by a plant growth chamber (PGC). The system currently contains two types of detector modules: 84 microPET R4 block detectors with 2.2 mm crystals to provide a large detecting area; and 32 Inveon block detectors with 1.5 mm crystals to provide higher spatial resolution. Outputs of the four microPET block detectors in a modular housing are concatenated by a custom printed circuit board to match the output characteristics of an Inveon detector. All the detectors are read out by QuickSilver electronics. The detector modules are configured to full rings with a 15 cm diameter trans-axial field of view (FOV) for dynamic tomographic imaging of small plants. Potentially, the Inveon detectors can be reconfigured to quarter-rings to get a 25 cm FOV using step-and-shoot motion. The imager contains 2 linear stages to position detectors at different heights for multi-bed scanning, and 2 rotation stages to collect coincidence events from all angles. The PET system has been built and integrated into the PGC. The system has a typical energy resolution of 15% for Inveon blocks and 24% for R4 blocks; timing resolution of 1.8 ns; and sensitivity of 1.3%,1.4%,3.0% measured at center of FOV, 5 cm off to R4 half-ring and 5 cm off to Inveon half-ring, respectively(with a 350-650 KeV energy and 3.1 ns timing window). System spatial resolution is similar to that of commercial microPET sytems, with 1.25 mm rod sources in the micro-Derenzo phantom resolved using ML-EM algorithm. Preliminary imaging experiments using different plants labeled with 11C-CO2 produced high-quality dynamic PET images.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.