-
Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout
Authors:
Paul Szypryt,
Douglas A. Bennett,
Ian Fogarty Florang,
Joseph W. Fowler,
Andrea Giachero,
Ruslan Hummatov,
Adriana E. Lita,
John A. B. Mates,
Sae Woo Nam,
Galen C. O'Neil,
Daniel S. Swetz,
Joel N. Ullom,
Michael R. Vissers,
Jordan Wheeler,
Jiansong Gao
Abstract:
Single-photon detectors based on the superconducting transition-edge sensor (TES) are used in a number of visible to near-infrared (VNIR) applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale photonic quantum computing or for future spectroscopic imaging applications in astronomy, the size of VNIR TES arrays must be incr…
▽ More
Single-photon detectors based on the superconducting transition-edge sensor (TES) are used in a number of visible to near-infrared (VNIR) applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale photonic quantum computing or for future spectroscopic imaging applications in astronomy, the size of VNIR TES arrays must be increased from a few pixels to many thousands. Historically, TES arrays have been read out with multiplexed superconducting quantum interference devices (SQUIDs), but the microsecond-duration pulse signals of VNIR TESs are notoriously difficult to multiplex. In this manuscript, we introduce the kinetic inductance current sensor (KICS), a more readily scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. KICS devices can replace SQUIDs for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a VNIR TES using a KICS with $3.7$ $\text{MHz}$ of bandwidth. We measure a readout noise of $1.4$ $\text{pA}/\sqrt{\text{Hz}}$, considerably below the TES noise at frequencies of interest, and a TES energy resolution of $(0.137 \pm 0.001)$ $\text{eV}$ at $0.8$ $\text{eV}$, comparable to resolutions observed with non-multiplexed SQUID readouts.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Crosstalk effects in microwave SQUID multiplexed TES bolometer readout
Authors:
John C. Groh,
Zeeshan Ahmed,
Shawn W. Henderson,
Johannes Hubmayr,
John A. B. Mates,
Maximiliano Silva-Feaver,
Joel Ullom,
Cyndia Yu
Abstract:
Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband…
▽ More
Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.
△ Less
Submitted 8 April, 2024; v1 submitted 9 November, 2023;
originally announced November 2023.
-
Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier
Authors:
M. Malnou,
J. A. B. Mates,
M. R. Vissers,
L. R. Vale,
D. R. Schmidt,
D. A. Bennett,
J. Gao,
J. N. Ullom
Abstract:
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodi…
▽ More
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
ASCENT - A balloon-borne hard X-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors
Authors:
Fabian Kislat,
Daniel Becker,
Douglas Bennett,
Adrika Dasgupta,
Joseph Fowler,
Christopher L. Fryer,
Johnathon Gard,
Ephraim Gau,
Danielle Gurgew,
Keon Harmon,
Takayuki Hayashi,
Scott Heatwole,
Md Arman Hossen,
Henric Krawczynski,
R. James Lanzi,
Jason Legere,
John A. B. Mates,
Mark McConnell,
Johanna Nagy,
Takashi Okajima,
Toshiki Sato,
Daniel Schmidt,
Sean Spooner,
Daniel Swetz,
Keisuke Tamura
, et al. (4 additional authors not shown)
Abstract:
Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormou…
▽ More
Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. The isotope ${}^{44}$Ti is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard X-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called ASCENT (A SuperConducting ENergetic x-ray Telescope). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55 eV Full Width Half Maximum (FWHM) energy resolution at 97 keV. This 8--16-fold improvement in energy resolution over NuSTAR will allow high resolution imaging and spectroscopy of the ${}^{44}$Ti emission. This will allow a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as: What is the source of the neutron star "kicks"? What is the dominant production pathway for ${}^{44}$Ti? Is the engine of Cas A unique?
△ Less
Submitted 4 January, 2023;
originally announced January 2023.
-
A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray
Authors:
Paul Szypryt,
Nathan Nakamura,
Daniel T. Becker,
Douglas A. Bennett,
Amber L. Dagel,
W. Bertrand Doriese,
Joseph W. Fowler,
Johnathon D. Gard,
J. Zachariah Harris,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Kurt W. Larson,
Zachary H. Levine,
John A. B. Mates,
D. McArthur,
Luis Miaja-Avila,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Daniel R. Schmidt,
Kyle R. Thompson,
Joel N. Ullom,
Leila Vale
, et al. (6 additional authors not shown)
Abstract:
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recent…
▽ More
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$α$ line.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography
Authors:
Paul Szypryt,
Douglas A. Bennett,
William J. Boone,
Amber L. Dagel,
Gabriella Dalton,
W. Bertrand Doriese,
Joseph W. Fowler,
Edward J. Garboczi,
Johnathon D. Gard,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Vincent Y. Kotsubo,
Kurt Larson,
Zachary H. Levine,
John A. B. Mates,
Daniel McArthur,
Kelsey M. Morgan,
Nathan Nakamura,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz
, et al. (6 additional authors not shown)
Abstract:
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approa…
▽ More
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $μ$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
-
Signal readout for Transition-Edge Sensor X-ray imaging spectrometers
Authors:
H. Akamatsu,
W. B. Doriese,
J. A. B. Mates,
B. D. Jackson
Abstract:
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/ΔE\urss{FWHM}$) of a few thousand across a broad energy range (200~eV to 10~keV or higher), would be a revolutionary instrument for the study of energetic astrophysical objects an…
▽ More
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/ΔE\urss{FWHM}$) of a few thousand across a broad energy range (200~eV to 10~keV or higher), would be a revolutionary instrument for the study of energetic astrophysical objects and phenomena. Signal readout is a critical enabling technology. Multiplexed readout, in which signals from multiple pixels are combined into a single amplifier channel, allows a kilo pixel-scale microcalorimeter array to meet the stringent requirements for power consumption, mass, volume, and cooling capacity in orbit. This chapter describes three different multiplexed-readout technologies for transition-edge-sensor microcalorimeters: time-division multiplexing, frequency-domain multiplexing, and microwave-SQUID multiplexing. For each multiplexing technique, we present the basic method, discuss some design considerations and parameters, and show the state of the art. The chapter concludes with a brief discussion of future prospects.
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Josef C. Frisch,
Shawn W. Henderson,
Max Silva-Feaver,
Kam Arnold,
David Brown,
Jake Connors,
Ari J. Cukierman,
J. Mitch D'Ewart,
Bradley J. Dober,
John E. Dusatko,
Gunther Haller,
Ryan Herbst,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Chao-Lin Kuo,
John A. B. Mates,
Larry Ruckman,
Joel Ullom,
Leila Vale,
Daniel D. Van Winkle,
Jesus Vasquez,
Edward Young
Abstract:
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arr…
▽ More
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. We focus in particular on the case of large channel count, low bandwidth applications, but the system has been easily reconfigured for high bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
△ Less
Submitted 22 August, 2022;
originally announced August 2022.
-
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Authors:
Daikang Yan,
Joel C. Weber,
Tejas Guruswamy,
Kelsey M. Morgan,
Galen C. O'Neil,
Abigail L. Wessels,
Douglas A. Bennett,
Christine G. Pappas,
John A. Mates,
Johnathon D. Gard,
Daniel T. Becker,
Joseph W. Fowler,
Daniel S. Swetz,
Daniel R. Schmidt,
Joel N. Ullom,
Takuma Okumura,
Tadaaki Isobe,
Toshiyuki Azuma,
Shinji Okada,
Shinya Yamada,
Tadashi Hashimoto,
Orlando Quaranta,
Antonino Miceli,
Lisa M. Gades,
Umeshkumar M. Patel
, et al. (3 additional authors not shown)
Abstract:
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers…
▽ More
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
The 511-CAM Mission: A Pointed 511 keV Gamma-Ray Telescope with a Focal Plane Detector Made of Stacked Transition Edge Sensor Microcalorimeter Arrays
Authors:
Farzane Shirazi,
Md. Arman Hossen,
Daniel Becker,
Daniel Schmidt,
Daniel Swetz,
Douglas Bennett,
Dana Braun,
Ephraim Gau,
Fabian Kislat,
Johnathon Gard,
John Mates,
Joel Weber,
Nicole Rodriguez Cavero,
Sohee Chun,
Lindsey Lisalda,
Andrew West,
Bhupal Dev,
Francesc Ferrer,
Richard Bose,
Joel Ullom,
Henric Krawczynski
Abstract:
The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from the interstellar medium. Alternatively, the positrons could be created by astrophysical sources, involving exclusively standard model physics. We describe here a new concept for a 511 keV mission called 511-CAM (511 keV ga…
▽ More
The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from the interstellar medium. Alternatively, the positrons could be created by astrophysical sources, involving exclusively standard model physics. We describe here a new concept for a 511 keV mission called 511-CAM (511 keV gamma-ray CAmera using Micro-calorimeters) that combines focusing gamma-ray optics with a stack of Transition Edge Sensor (TES) microcalorimeter arrays in the focal plane. The 511-CAM detector assembly has a projected 511 keV energy resolution of 390 eV Full Width Half Maximum (FWHM) or better, and improves by a factor of at least 11 on the performance of state-of-the-art Ge-based Compton telescopes. Combining this unprecedented energy resolution with sub-arcmin angular resolutions afforded by Laue lens or channeling optics could make substantial contributions to identifying the origin of the 511 keV emission by discovering and characterizing point sources and measuring line-of-sight velocities of the emitting plasmas.
△ Less
Submitted 12 September, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Bandwidth and Aliasing in the Microwave SQUID Multiplexer
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Jake A. Connors,
J. Mitch D'Ewart,
Bradley Dober,
Josef C. Frisch,
Shawn W. Henderson,
Gene C. Hilton,
Johannes Hubmayr,
Stephen E. Kuenstner,
J. A. Ben Mates,
Maximiliano Silva-Feaver,
Joel N. Ullom,
Leila R. Vale,
Dan Van Winkle,
Edward Young
Abstract:
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts.…
▽ More
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of umux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. We present simulations and measurements of umux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer
Authors:
David J. Mercer,
Ryan Winkler,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Krystal I. de Castro,
Eric A. Feissle,
Joseph W. Fowler,
Johnathon D. Gard,
John A. B. Mates,
Daniel G. McNeel,
Nathan J. Ortiz,
Daniel Schmidt,
Katherine A. Schreiber,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Sophie L. Weidenbenner,
Abigail L. Wessels
Abstract:
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter…
▽ More
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.
△ Less
Submitted 8 July, 2022; v1 submitted 6 February, 2022;
originally announced February 2022.
-
Observations of compact sources in galaxy clusters using MUSTANG2
Authors:
Simon R. Dicker,
Elia S. Battistelli,
Tanay Bhandarkar,
Mark J. Devlin,
Shannon M. Duff,
Gene Hilton,
Matt Hilton,
Adam D. Hincks,
Johannes Hubmayr,
Kevin Huffenberger,
John P. Hughes,
Luca Di Mascolo,
Brian S. Mason,
J. A. B. Mates,
Jeff McMahon,
Tony Mroczkowski,
Sigurd Naess,
John Orlowski-Scherer,
Bruce Partridge,
Federico Radiconi,
Charles Romero,
Craig L. Sarazin,
Neelima Sehgal,
Jonathan Sievers,
Cristóbal Sifón
, et al. (4 additional authors not shown)
Abstract:
Compact sources can cause scatter in the scaling relationships between the amplitude of the thermal Sunyaev-Zel'dovich Effect (tSZE) in galaxy clusters and cluster mass. Estimates of the importance of this scatter vary - largely due to limited data on sources in clusters at the frequencies at which tSZE cluster surveys operate. In this paper we present 90 GHz compact source measurements from a sam…
▽ More
Compact sources can cause scatter in the scaling relationships between the amplitude of the thermal Sunyaev-Zel'dovich Effect (tSZE) in galaxy clusters and cluster mass. Estimates of the importance of this scatter vary - largely due to limited data on sources in clusters at the frequencies at which tSZE cluster surveys operate. In this paper we present 90 GHz compact source measurements from a sample of 30 clusters observed using the MUSTANG2 instrument on the Green Bank Telescope. We present simulations of how a source's flux density, spectral index, and angular separation from the cluster's center affect the measured tSZE in clusters detected by the Atacama Cosmology Telescope (ACT). By comparing the MUSTANG2 measurements with these simulations we calibrate an empirical relationship between 1.4 GHz flux densities from radio surveys and source contamination in ACT tSZE measurements. We find 3 per cent of the ACT clusters have more than a 20 per cent decrease in Compton-y but another 3 per cent have a 10 per cent increase in the Compton-y due to the matched filters used to find clusters. As sources affect the measured tSZE signal and hence the likelihood that a cluster will be detected, testing the level of source contamination in the tSZE signal using a tSZE selected catalog is inherently biased. We confirm this by comparing the ACT tSZE catalog with optically and X-ray selected cluster catalogs. There is a strong case for a large, high resolution survey of clusters to better characterize their source population.
△ Less
Submitted 22 September, 2021; v1 submitted 14 July, 2021;
originally announced July 2021.
-
The Simons Observatory microwave SQUID multiplexing detector module design
Authors:
Heather McCarrick,
Erin Healy,
Zeeshan Ahmed,
Kam Arnold,
Zachary Atkins,
Jason E. Austermann,
Tanay Bhandarkar,
Jim A. Beall,
Sarah Marie Bruno,
Steve K. Choi,
Jake Connors,
Nicholas F. Cothard,
Kevin D. Crowley,
Simon Dicker,
Bradley Dober,
Cody J. Duell,
Shannon M. Duff,
Daniel Dutcher,
Josef C. Frisch,
Nicholas Galitzki,
Megan B. Gralla,
Jon E. Gudmundsson,
Shawn W. Henderson,
Gene C. Hilton,
Shuay-Pwu Patty Ho
, et al. (34 additional authors not shown)
Abstract:
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of…
▽ More
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing ($μ$mux). Simons Observatory will use 49 modules containing 60,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a $95\%$ yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 $\mathrm{pA/\sqrt{Hz}}$. This impacts the projected SO map** speed by $< 8\%$, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.
△ Less
Submitted 16 September, 2021; v1 submitted 28 June, 2021;
originally announced June 2021.
-
New Experimentally Observable Gamma-ray Emissions from 241Am Nuclear Decay
Authors:
Katrina E. Koehler,
Michael D. Yoho,
Matthew H. Carpenter,
Mark P. Croce,
David J. Mercer,
Chandler M. Smith,
Aidan D. Tollefson,
Duc T. Vo,
Michael A. Famiano,
Daniel T. Becker,
Johnathon D. Gard,
J. A. B. Mates,
Nathan J. Ortiz,
Joel N. Ullom,
Abigail L. Wessels,
Douglas A. Bennett,
Daniel R. Schmidt,
Daniel S. Swetz,
Leila R. Vale
Abstract:
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis al…
▽ More
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis algorithms for microcalorimeters.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
The design of the Ali CMB Polarization Telescope receiver
Authors:
Maria Salatino,
Jason E. Austermann,
Keith L. Thompson,
Peter A. R. Ade,
Xiran Bai,
James A. Beall,
Dan T. Becker,
Yifu Cai,
Zhi Chang,
Ding Chen,
Pisin Chen,
Jake Connors,
Jacques Delabrouille,
Bradley Dober,
Shannon M. Duff,
Guanhua Gao,
Shamik Ghosh,
Richard C. Givhan,
Gene C. Hilton,
Bin Hu,
Johannes Hubmayr,
Ethan D. Karpel,
Chao-Lin Kuo,
Hong Li,
Mingzhe Li
, et al. (50 additional authors not shown)
Abstract:
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polariza…
▽ More
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.
△ Less
Submitted 23 January, 2021;
originally announced January 2021.
-
Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement
Authors:
A. Giachero,
B. Alpert,
D. T. Becker,
D. A. Bennett,
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
J. D. Gard,
F. Gatti,
G. C. Hilton,
J. A. B. Mates,
A. Nucciotti,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale
Abstract:
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Tran…
▽ More
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
The Simons Observatory: Magnetic Sensitivity Measurements of Microwave SQUID Multiplexers
Authors:
Eve M. Vavagiakis,
Zeeshan Ahmed,
Aamir Ali,
Kam Arnold,
Jason Austermann,
Sarah Marie Bruno,
Steve K. Choi,
Jake Connors,
Nicholas F. Cothard,
Simon Dicker,
Brad Dober,
Shannon Duff,
Valentina Fanfani,
Erin Healy,
Shawn Henderson,
Shuay-Pwu Patty Ho,
Duc-Thuong Hoang,
Gene Hilton,
Johannes Hubmayr,
Nicoletta Krachmalnicoff,
Yaqiong Li,
John Mates,
Heather McCarrick,
Federico Nati,
Michael Niemack
, et al. (8 additional authors not shown)
Abstract:
The Simons Observatory (SO) will be a cosmic microwave background (CMB) survey experiment with three small-aperture telescopes and one large-aperture telescope, which will observe from the Atacama Desert in Chile. In total, SO will field $\sim$70,000 transition-edge sensor (TES) bolometers in six spectral bands centered between 27 and 280 GHz in order to achieve the sensitivity necessary to measur…
▽ More
The Simons Observatory (SO) will be a cosmic microwave background (CMB) survey experiment with three small-aperture telescopes and one large-aperture telescope, which will observe from the Atacama Desert in Chile. In total, SO will field $\sim$70,000 transition-edge sensor (TES) bolometers in six spectral bands centered between 27 and 280 GHz in order to achieve the sensitivity necessary to measure or constrain numerous cosmological quantities. The SO Universal Focal Plane Modules (UFMs) each contain a 150 mm diameter TES detector array, horn or lenslet optical coupling, cold readout components, and magnetic shielding. SO will use a microwave SQUID multiplexing ($μ$MUX) readout at an initial multiplexing factor of $\sim$1000; the cold (100 mK) readout components are packaged in a $μ$MUX readout module, which is part of the UFM, and can also be characterized independently. The 100 mK stage TES bolometer arrays and microwave SQUIDs are sensitive to magnetic fields, and their measured response will vary with the degree to which they are magnetically shielded. We present measurements of the magnetic pickup of test microwave SQUID multiplexers as a study of various shielding configurations for the Simons Observatory. We discuss how these measurements motivated the material choice and design of the UFM magnetic shielding.
△ Less
Submitted 8 December, 2020;
originally announced December 2020.
-
A Microwave SQUID Multiplexer Optimized for Bolometric Applications
Authors:
B. Dober,
Z. Ahmed,
K. Arnold,
D. T. Becker,
D. A. Bennett,
J. A. Connors,
A. Cukierman,
J. M. D'Ewart,
S. M. Duff,
J. E. Dusatko,
J. C. Frisch,
J. D. Gard,
S. W. Henderson,
R. Herbst,
G. C. Hilton,
J. Hubmayr,
Y. Li,
J. A. B. Mates,
H. McCarrick,
C. D Reintsema,
M. Silva-Feaver,
L. Ruckman,
J. N. Ullom,
L. R. Vale,
D. D. Van Winkle
, et al. (5 additional authors not shown)
Abstract:
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4…
▽ More
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.
△ Less
Submitted 19 January, 2021; v1 submitted 15 October, 2020;
originally announced October 2020.
-
Improved Plutonium and Americium Photon Branching Ratios from Microcalorimeter Gamma Spectroscopy
Authors:
Michael D. Yoho,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Johnathon D. Gard,
J. A. Ben Mates,
David J. Mercer,
Nathan J. Ortiz,
Daniel R. Schmidt,
Chandler M. Smith,
Daniel S. Swetz,
Aidan D. Tollefson,
Joel N. Ullom,
Leila R. Vale,
Abigail L. Wessels,
Duc T. Vo
Abstract:
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-h…
▽ More
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium (238Pu,239Pu,241Pu) and 241Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. We show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2{3 for four branching ratios.
△ Less
Submitted 22 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters
Authors:
D. T. Becker,
D. A. Bennett,
M. Biasotti,
M. Borghesi,
V. Ceriale,
M. De Gerone,
M. Faverzani,
E. Ferri,
J. W. Fowler,
G. Gallucci,
J. D. Gard,
A. Giachero,
J. P. Hays-Wehle,
G. C. Hilton,
J. A. B Mates,
A. Nucciotti,
A. Orlando,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In…
▽ More
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In order to acquire the large needed statistics, by kee** the pile-up contribution as low as possible, 1024 transition edge sensors (TESs) with high energy and time resolutions will be employed. Microcalorimeter and bolometer arrays based on transition edge sensor with thousands of pixels are under development for several space-based and ground-based applications, including astrophysics, nuclear and particle physics, and materials science. The common necessary challenge is to develop pratical multiplexing techniques in order to simplify the cryogenics and readout systems. Despite the various multiplexing variants which are being developed have been successful, new approaches are needed to enable scaling to larger pixel counts and faster sensors, as requested for HOLMES, reducing also the cost and complexity of readout. A very novel technique that meets all of these requirements is based on superconducting microwave resonators coupled to radio-frequency Superconducting Quantum Interference Devices, in which the the changes in the TES input current is tranduced to a change in phase of a microwave signal. In this work we introduce the basics of this technique, the design and development of the first two-channel read out system and its performances with the first TES detectors specifically designed for HOLMES. In the last part we explain how to extend this approach scaling to 1024 pixels.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
Microwave multiplexing on the Keck Array
Authors:
Ari Cukierman,
Zeeshan Ahmed,
Shawn Henderson,
Edward Young,
Cyndia Yu,
Denis Barkats,
David Brown,
Saptarshi Chaudhuri,
James Cornelison,
John M. D'Ewart,
Marion Dierickx,
Bradley J. Dober,
John Dusatko,
Sofia Fatigoni,
Jeff P. Filippini,
Josef C. Frisch,
Gunther Haller,
Mark Halpern,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Kirit S. Karkare,
Ethan Karpel,
Sarah A. Kernasovskiy,
John M. Kovac
, et al. (60 additional authors not shown)
Abstract:
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled…
▽ More
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio-frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5-6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.
△ Less
Submitted 17 January, 2020; v1 submitted 3 September, 2019;
originally announced September 2019.
-
New Technologies for Discovery
Authors:
Z. Ahmed,
A. Apresyan,
M. Artuso,
P. Barry,
E. Bielejec,
F. Blaszczyk,
T. Bose,
D. Braga,
S. A. Charlebois,
A. Chatterjee,
A. Chavarria,
H. -M. Cho,
S. Dalla Torre,
M. Demarteau,
D. Denisov,
M. Diefenthaler,
A. Dragone,
F. Fahim,
C. Gee,
S. Habib,
G. Haller,
J. Hogan,
B. J. P. Jones,
M. Garcia-Sciveres,
G. Giacomini
, et al. (58 additional authors not shown)
Abstract:
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by hi…
▽ More
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.
△ Less
Submitted 10 August, 2019; v1 submitted 31 July, 2019;
originally announced August 2019.
-
A Model for Excess Johnson Noise in Superconducting Transition-edge Sensors
Authors:
Abigail Wessels,
Kelsey Morgan,
Daniel T. Becker,
Johnathon D. Gard,
Gene C. Hilton,
John A. B. Mates,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Douglas A. Bennett
Abstract:
Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature. Electrical noise is observed in TESs that exceeds the predictions of existing noise theories. In this manuscript, we describe a model for the unexplained excess noi…
▽ More
Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature. Electrical noise is observed in TESs that exceeds the predictions of existing noise theories. In this manuscript, we describe a model for the unexplained excess noise based on the dynamic resistance of the TES and noise mixed down from frequencies around the Josephson oscillations. We derive an expression for the power spectral density of this noise and show that its predictions match measured data.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Authors:
Shawn W. Henderson,
Zeeshan Ahmed,
Jason Austermann,
Daniel Becker,
Douglas A. Bennett,
David Brown,
Saptarshi Chaudhuri,
Hsiao-Mei Sherry Cho,
John M. D'Ewart,
Bradley Dober,
Shannon M. Duff,
John E. Dusatko,
Sofia Fatigoni,
Josef C. Frisch,
Jonathon D. Gard,
Mark Halpern,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Ethan D. Karpel,
Sarah S. Kernasovskiy,
Stephen E. Kuenstner,
Chao-Lin Kuo,
Dale Li,
John A. B. Mates
, et al. (7 additional authors not shown)
Abstract:
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per se…
▽ More
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to read out each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for several future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Status of the HOLMES Experiment to Directly Measure the Neutrino Mass
Authors:
A. Nucciotti,
B. Alpert,
M. Balata,
D. BeckerD. Bennett,
A. Bevilacqua,
M. Biasotti,
V. Ceriale,
G. Ceruti,
D. Corsini,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
G. Gallucci,
J. Gard,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Köster,
M. Lusignoli,
J. Mates,
S. Nisi
, et al. (13 additional authors not shown)
Abstract:
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass…
▽ More
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope $^{163}$Ho. In a calorimetric measurement the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. The most suitable detectors for this type of measurement are low temperature thermal detectors, where all the energy released into an absorber is converted into a temperature increase that can be measured by a sensitive thermometer directly coupled with the absorber. This measurement was originally proposed in 1982 by A. De Rujula and M. Lusignoli, but only in the last decade the technological progress in detectors development has allowed to design a sensitive experiment. HOLMES plans to deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors
Authors:
S. A. Kernasovskiy,
S. E. Kuenstner,
E. Karpel,
Z. Ahmed,
D. D. Van Winkle,
S. Smith,
J. Dusatko,
J. C. Frisch,
S. Chaudhuri,
H. M. Cho,
B. J. Dober,
S. W. Henderson,
G. C. Hilton,
J. Hubmayr,
K. D. Irwin,
C. L. Kuo,
D. Li,
J. A. B. Mates,
M. Nasr,
S. Tantawi,
J. Ullom,
L. Vale,
B. Young
Abstract:
Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detecto…
▽ More
Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detectors (MKIDs). In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator's excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at $\sim$6 MHz with center frequencies $\sim$5-6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.
△ Less
Submitted 21 May, 2018;
originally announced May 2018.
-
Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers
Authors:
B. Dober,
D. T. Becker,
D. A. Bennett,
S. A. Bryan,
S. M. Duff,
J. D. Gard,
J. P. Hays-Wehle,
G. C. Hilton,
J. Hubmayr,
J. A. B. Mates,
C. D. Reintsema,
L. R. Vale,
J. N. Ullom
Abstract:
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, wh…
▽ More
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB map** on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $μ$MUX as a viable readout technique for future CMB imaging instruments.
△ Less
Submitted 15 December, 2017; v1 submitted 11 October, 2017;
originally announced October 2017.
-
Measuring the electron neutrino mass with improved sensitivity: the HOLMES experiment
Authors:
A. Giachero,
B. Alpert,
D. Becker,
D. Bennett,
M. Biasotti,
C. Brofferio,
V. Ceriale,
G. Ceruti,
D. Corsini,
P. Day,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
E. Fumagalli,
G. Gallucci,
J. Gard,
F. Gatti J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Koester,
M. Lusignoli,
J. Mates,
S. Nisi
, et al. (17 additional authors not shown)
Abstract:
HOLMES is a new experiment aiming at directly measuring the neutrino mass with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement of the energy released in the decay of $^{163}$Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with spectrometers. This measurement was proposed in 1982 by A. De…
▽ More
HOLMES is a new experiment aiming at directly measuring the neutrino mass with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement of the energy released in the decay of $^{163}$Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress has allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. HOLMES, besides being an important step forward in the direct neutrino mass measurement with a calorimetric approach, will also establish the potential of this approach to extend the sensitivity down to 0.1 eV and lower. In its final configuration HOLMES will collect about $3\cdot 10^{13}$ decays with 1000 detectors characterized by an instrumental energy resolution of the order of few eV and a time resolution of few microseconds. To embed the $^{163}$Ho into the gold absorbers a custom mass separator ion implanter is being developed. The detectors used for the HOLMES experiment will be Mo/Cu bilayers TESs (Transition Edge Sensors) on SiN$_x$ membrane with gold absorbers. Microwave multiplexed rf-SQUIDs are the best available technique to read out large array of such detectors. An extensive R&D activity is in progress in order to maximize the multiplexing factor while preserving the performances of the individual detectors. The current activities are focused on the the single detector performances optimization and on the $^{163}$Ho isotope production and embedding. A preliminary measurement of a sub-array of $4\times 16$ detectors is planned late in 2017. In this contribution we present the HOLMES project with its technical challenges, its status and perspectives.
△ Less
Submitted 7 March, 2017; v1 submitted 12 December, 2016;
originally announced December 2016.
-
Development of microwave-multiplexed superconductive detectors for the HOLMES experiment
Authors:
A. Giachero,
D. Becker,
D. A. Bennett,
M. Faverzani,
E. Ferri,
J. W. Fowler,
J. D. Gard,
J. P. Hays-Wehle,
G. C. Hilton,
M. Maino,
J. A. B Mates,
A. Puiu,
A. Nucciotti,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy ($\sim$eV on keV) and time resolution ($\sim 1\,μ$s) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensit…
▽ More
In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy ($\sim$eV on keV) and time resolution ($\sim 1\,μ$s) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensitivity. HOLMES is a new experiment to directly measure the neutrino mass with a sensitivity as low as 2\,eV. HOLMES will perform a calorimetric measurement of the energy released in the electron capture (EC) decay of 163Ho. In its final configuration, HOLMES will deploy 1000 detectors of low temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiN\textsubscript{x} membrane with gold absorbers. The readout is based on the use of rf-SQUIDs as input devices with flux ramp modulation for linearization purposes; the rf-SQUID is then coupled to a superconducting lambda/4-wave resonator in the GHz range, and the modulated signal is finally read out using the homodyne technique. The TES detectors have been designed with the aim of achieving an energy resolution of a few eV at the spectrum endpoint and a time resolution of a few micro-seconds, in order to minimize pile-up artifacts.
△ Less
Submitted 18 January, 2016; v1 submitted 15 January, 2016;
originally announced January 2016.
-
HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity
Authors:
B. Alpert,
M. Balata,
D. Bennett,
M. Biasotti,
C. Boragno,
C. Brofferio,
V. Ceriale,
D. Corsini,
P. K. Day,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Koester,
M. Lusignoli,
M. Maino,
J. Mates,
S. Nisi,
R. Nizzolo
, et al. (13 additional authors not shown)
Abstract:
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982…
▽ More
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.
△ Less
Submitted 17 March, 2015; v1 submitted 16 December, 2014;
originally announced December 2014.
-
High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
Authors:
Omid Noroozian,
John A. B. Mates,
Douglas A. Bennett,
Justus A. Brevik,
Joseph W. Fowler,
Jiansong Gao,
Gene C. Hilton,
Robert D. Horansky,
Kent D. Irwin,
Zhao Kang,
Daniel R. Schmidt,
Leila R. Vale,
Joel N. Ullom
Abstract:
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators co…
▽ More
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.
△ Less
Submitted 27 October, 2013;
originally announced October 2013.
-
Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields
Authors:
G. M. Stiehl,
H. M. Cho,
G. C. Hilton,
K. D. Irwin,
J. A. B. Mates,
C. D. Reintsema,
B. L. Zink
Abstract:
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs.…
▽ More
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs. These designs include a new variety with improved gradiometry that significantly reduces the effective area of both the first and second stage SQUID amplifiers.
△ Less
Submitted 30 August, 2010;
originally announced August 2010.
-
Strongly quadrature-dependent noise in superconducting micro-resonators measured at the vacuum-noise limit
Authors:
J. Gao,
L. R. Vale,
J. A. B. Mates,
D. R. Schmidt,
G. C. Hilton,
K. D. Irwin,
F. Mallet,
M. A. Castellanos-Beltran,
K. W. Lehnert,
J. Zmuidzinas,
H. G. Leduc
Abstract:
We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement…
▽ More
We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement sensitivity. These measurements demonstrate that the excess dissipation-quadrature noise is negligible compared to vacuum fluctuations, at typical readout powers used in micro-resonator applications. Our results have important implications for resonant readout of various devices such as detectors, qubits and nano-mechanical oscillators.
△ Less
Submitted 30 July, 2010;
originally announced August 2010.