Simultaneous reconstruction and displacement estimation for spectral-domain optical coherence elastography
Authors:
Jonathan H. Mason,
Yvonne Reinwald,
Ying Yang,
Sarah Waters,
Alicia El Haj,
Pierre O. Bagnaninchi
Abstract:
Optical coherence elastography allows the characterization of the mechanical properties of tissues, and can be performed through estimating local displacement maps from subsequent acquisitions of a sample under different loads. This displacement estimation is limited by noise in the images, which can be high in dynamic systems due to the inability to perform long exposures or B-scan averaging. In…
▽ More
Optical coherence elastography allows the characterization of the mechanical properties of tissues, and can be performed through estimating local displacement maps from subsequent acquisitions of a sample under different loads. This displacement estimation is limited by noise in the images, which can be high in dynamic systems due to the inability to perform long exposures or B-scan averaging. In this work, we propose a framework for simultaneously enhancing both the image quality and displacement map for elastography, by motion compensated denoising with the block-matching and 4D filtering (BM4D) method, followed by a re-estimation of displacement. We adopt the interferometric synthetic aperture microscopy (ISAM) method to enhance the lateral resolution away from the focal plane, and use sub-pixel cross correlation block matching for non-uniform deformation estimation. We validate this approach on data from a commercial spectral domain optical coherence tomography system, whereby we observe an enhancement of both image and displacement accuracy of up to 33% over a standard approach.
△ Less
Submitted 2 August, 2021;
originally announced August 2021.
-
Model-based iterative reconstruction for spectral-domain optical coherence tomography
Authors:
Jonathan H. Mason,
Yvonne Reinwald,
Ying Yang,
Sarah Waters,
Alicia El Haj,
Pierre O. Bagnaninchi
Abstract:
Spectral domain optical coherence tomography (OCT) offers high resolution multidimensional imaging, but generally suffers from defocussing, intensity falloff and shot noise, causing artifacts and image degradation along the imaging depth. In this work, we develop an iterative statistical reconstruction technique, based upon the interferometric synthetic aperture microscopy (ISAM) model with additi…
▽ More
Spectral domain optical coherence tomography (OCT) offers high resolution multidimensional imaging, but generally suffers from defocussing, intensity falloff and shot noise, causing artifacts and image degradation along the imaging depth. In this work, we develop an iterative statistical reconstruction technique, based upon the interferometric synthetic aperture microscopy (ISAM) model with additive noise, to actively compensate for these effects. For the ISAM re-sampling, we use a non uniform FFT with Kaiser-Bessel interpolation, offering efficiency and high accuracy. We then employ an accelerated gradient descent based algorithm, to minimize the negative log-likelihood of the model, and include spatial or wavelet sparsity based penalty functions, to provide appropriate regularization for given image structures. We evaluate our approach with titanium oxide micro-bead and cucumber samples with a commercial spectral domain OCT system, under various subsampling regimes, and demonstrate superior image quality over traditional reconstruction and ISAM methods.
△ Less
Submitted 2 August, 2021;
originally announced August 2021.
-
Blur resolved OCT: full-range interferometric synthetic aperture microscopy through dispersion encoding
Authors:
Jonathan H. Mason,
Mike E. Davies,
Pierre O. Bagnaninchi
Abstract:
We present a computational method for full-range interferometric synthetic aperture microscopy (ISAM) under dispersion encoding. With this, one can effectively double the depth range of optical coherence tomography (OCT), whilst dramatically enhancing the spatial resolution away from the focal plane. To this end, we propose a model-based iterative reconstruction (MBIR) method, where ISAM is direct…
▽ More
We present a computational method for full-range interferometric synthetic aperture microscopy (ISAM) under dispersion encoding. With this, one can effectively double the depth range of optical coherence tomography (OCT), whilst dramatically enhancing the spatial resolution away from the focal plane. To this end, we propose a model-based iterative reconstruction (MBIR) method, where ISAM is directly considered in an optimization approach, and we make the discovery that sparsity promoting regularization effectively recovers the full-range signal. Within this work, we adopt an optimal nonuniform discrete fast Fourier transform (NUFFT) implementation of ISAM, which is both fast and numerically stable throughout iterations. We validate our method with several complex samples, scanned with a commercial SD-OCT system with no hardware modification. With this, we both demonstrate full-range ISAM imaging, and significantly outperform combinations of existing methods.
△ Less
Submitted 31 January, 2020; v1 submitted 15 May, 2019;
originally announced May 2019.
-
Quantitative cone-beam CT reconstruction with polyenergetic scatter model fusion
Authors:
Jonathan H. Mason,
Alessandro Perelli,
William H. Nailon,
Mike E. Davies
Abstract:
Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide quantitative imaging in CT, but they are usually incompatible with scatter contaminated measurements. In this work, we introduce a polyenergetic convolutional scatter…
▽ More
Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide quantitative imaging in CT, but they are usually incompatible with scatter contaminated measurements. In this work, we introduce a polyenergetic convolutional scatter model that is directly fused into the reconstruction process, and exploits information readily available at each iteration for a fraction of additional computational cost. We evaluate this method with numerical and real CBCT measurements, and show significantly enhanced electron density estimation and artifact mitigation over pre-calculated fast adaptive scatter kernel superposition (fASKS). We demonstrate our approach has two levels of benefit: reducing the bias introduced by estimating scatter prior to reconstruction; and adapting to the spectral and spatial properties of the specimen.
△ Less
Submitted 10 January, 2020; v1 submitted 11 May, 2018;
originally announced May 2018.
-
Polyquant CT: direct electron and mass density reconstruction from a single polyenergetic source
Authors:
Jonathan H. Mason,
Alessandro Perelli,
William H. Nailon,
Mike E. Davies
Abstract:
Quantifying material mass and electron density from computed tomography (CT) reconstructions can be highly valuable in certain medical practices, such as radiation therapy planning. However, uniquely parameterising the X-ray attenuation in terms of mass or electron density is an ill-posed problem when a single polyenergetic source is used with a spectrally indiscriminate detector. Existing approac…
▽ More
Quantifying material mass and electron density from computed tomography (CT) reconstructions can be highly valuable in certain medical practices, such as radiation therapy planning. However, uniquely parameterising the X-ray attenuation in terms of mass or electron density is an ill-posed problem when a single polyenergetic source is used with a spectrally indiscriminate detector. Existing approaches to single source polyenergetic modelling often impose consistency with a physical model, such as water--bone or photoelectric--Compton decompositions, which will either require detailed prior segmentation or restrictive energy dependencies, and may require further calibration to the quantity of interest. In this work, we introduce a data centric approach to fitting the attenuation with piecewise-linear functions directly to mass or electron density, and present a segmentation-free statistical reconstruction algorithm for exploiting it, with the same order of complexity as other iterative methods. We show how this allows both higher accuracy in attenuation modelling, and demonstrate its superior quantitative imaging, with numerical chest and metal implant data, and validate it with real cone-beam CT measurements.
△ Less
Submitted 29 April, 2019; v1 submitted 27 June, 2017;
originally announced June 2017.