Precision spectroscopy of non-thermal molecular plasmas using mid-infrared optical frequency comb Fourier transform spectroscopy
Authors:
Ibrahim Sadiek,
Alexander Puth,
Grzegorz Kowzan,
Akiko Nishiyama,
Sarah-Johanna Klose,
Jürgen Röpcke,
Norbert Lang,
Piotr Masłowski,
Jean-Pierre H. van Helden
Abstract:
Non-thermal molecular plasmas play a crucial role in numerous industrial processes and hold significant potential for driving essential chemical transformations. Accurate information about the molecular composition of the plasmas and the distribution of populations among quantum states is essential for understanding and optimizing plasma processes. Here, we apply a mid-infrared frequency comb-base…
▽ More
Non-thermal molecular plasmas play a crucial role in numerous industrial processes and hold significant potential for driving essential chemical transformations. Accurate information about the molecular composition of the plasmas and the distribution of populations among quantum states is essential for understanding and optimizing plasma processes. Here, we apply a mid-infrared frequency comb-based Fourier transform spectrometer to measure high-resolution spectra of plasmas containing hydrogen, nitrogen, and a carbon source in the 2800 - 3400 cm$^{-1}$ range. The spectrally broadband and high-resolution capabilities of this technique enable quantum-state-resolved spectroscopy of multiple plasma-generated species simultaneously, including CH$_4$, C$_2$H$_2$, C$_2$H$_6$, NH$_3$, and HCN, providing detailed information beyond the limitations of current methods. Using a line-by-line fitting approach, we analyzed 548 resolved transitions across five vibrational bands of plasma-generated HCN. The results indicate a significant non-thermal distribution of the populations among the quantum states, with distinct temperatures observed for lower and higher rotational quantum numbers, with a temperature difference of about 62 K. Broadband state-resolved-spectroscopy via comb-based methods provides unprecedented fundamental insights into the non-thermal nature of molecular plasmas - a detailed picture that has never been accomplished before for such complex non-thermal environment.
△ Less
Submitted 22 March, 2024;
originally announced March 2024.
-
Line-shape study of CO perturbed by N${_2}$ with mid-infrared frequency comb-based Fourier-transform spectroscopy
Authors:
Akiko Nishiyama,
Grzegorz Kowzan,
Dominik Charczun,
Roman Ciuryło,
Nicola Coluccelli,
Piotr Masłowski
Abstract:
We developed a mid-infrared optical frequency comb-based Fourier-transform spectrometer and performed a line-shape study of the fundamental vibrational band of CO perturbed by N${_2}$, which is crucial for atmospheric science and astronomical observations. The comb-based FTS enabled us to measure the whole vibrational band with high resolution and precision at several pressures between 10 and 400…
▽ More
We developed a mid-infrared optical frequency comb-based Fourier-transform spectrometer and performed a line-shape study of the fundamental vibrational band of CO perturbed by N${_2}$, which is crucial for atmospheric science and astronomical observations. The comb-based FTS enabled us to measure the whole vibrational band with high resolution and precision at several pressures between 10 and 400 Torr. Observed absorption profiles were fitted with the speed-dependent Voigt profile. Collisional broadening, speed-dependent collisional width and shift coefficients are derived. The reliability of our results is established from considerations of systematic errors and comparison with previous studies.
△ Less
Submitted 16 February, 2024;
originally announced February 2024.
-
Stimulated-Raman-Scattering Metrology
Authors:
M. Lamperti,
L. Rutkowski,
D. Ronchetti,
D. Gatti,
R. Gotti,
G. Cerullo,
F. Thibault,
H. Jóźwiak,
S. Wójtewicz,
P. Masłowski,
P. Wcisło,
D. Polli,
M. Marangoni
Abstract:
Frequency combs have revolutionized optical frequency metrology, allowing one to determine highly accurate transition frequencies of a wealth of molecular species. Despite a recognized scientific interest, these progresses have only marginally benefited infrared-inactive transitions, due to their inherently weak cross-sections. Here we overcome this limitation by introducing stimulated-Raman-scatt…
▽ More
Frequency combs have revolutionized optical frequency metrology, allowing one to determine highly accurate transition frequencies of a wealth of molecular species. Despite a recognized scientific interest, these progresses have only marginally benefited infrared-inactive transitions, due to their inherently weak cross-sections. Here we overcome this limitation by introducing stimulated-Raman-scattering metrology, where a frequency comb is exploited to calibrate the frequency detuning between the pump and Stokes excitation lasers. We apply this approach to molecular hydrogen to test quantum electrodynamics. We measure the transition frequency of the Q(1) fundamental line of H$_2$ around 4155 cm$^{-1}$ with few parts-per-billion uncertainty, which is comparable to the theoretical benchmark of ab initio calculations and more than a decade better than the experimental state of the art. Our comb-calibrated stimulated Raman scattering spectrometer extends the toolkit of optical frequency metrology as it can be applied, with simple technical changes, to many other infrared-inactive transitions, over a 50-5000 cm$^{-1}$ range that covers also purely rotational bands.
△ Less
Submitted 8 July, 2022;
originally announced July 2022.
-
Dual-comb cavity ring-down spectroscopy
Authors:
D. Lisak,
D. Charczun,
A. Nishiyama,
T. Voumard,
T. Wildi,
G. Kowzan,
V. Brasch,
T. Herr,
A. J. Fleisher,
J. T. Hodges,
R. Ciuryło,
A. Cygan,
P. Masłowski
Abstract:
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heter…
▽ More
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heterodyne detection of ring-down signals with a local oscillator comb to yield absorption and dispersion spectra. These spectra are obtained from widths and positions of cavity modes. We present two approaches which leverage the dynamic cavity response to coherently or randomly driven changes in the amplitude or frequency of the probe field. Both techniques yield accurate spectra of methane - an important greenhouse gas and breath biomarker. The high sensitivity and accuracy of broadband DC-CRDS, shows promise for applications like studies of the structure and dynamics of large molecules, multispecies trace gas detection and isotopic composition.
△ Less
Submitted 14 June, 2021;
originally announced June 2021.
-
Ultra-high finesse cavity-enhanced spectroscopy for accurate tests of quantum electrodynamics for molecules
Authors:
M. Zaborowski,
M. Słowiński,
K. Stankiewicz,
F. Thibault,
A. Cygan,
H. Jóźwiak,
G. Kowzan,
P. Masłowski,
A. Nishiyama,
N. Stolarczyk,
S. Wójtewicz,
R. Ciuryło,
D. Lisak,
P. Wcisło
Abstract:
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reach…
▽ More
We report the most accurate measurement of the position of the weak quadrupole S(2) 2-0 line in D$_2$. The spectra were collected with a frequency-stabilized cavity ring-down spectrometer (FS-CRDS) with an ultra-high finesse optical cavity ($\mathcal{F}$ = 637 000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reached 40 kHz of statistical uncertainty and 161 kHz of absolute accuracy, achieving the highest accuracy for homonuclear isotopologues of molecular hydrogen. The accuracy of our measurement corresponds to the fifth significant digit of the leading term in QED correction. We observe 2.3$σ$ discrepancy with the recent theoretical value.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Intensity Noise Optimization of a Mid-Infrared Frequency Comb Difference Frequency Generation Source
Authors:
Vinicius Silva de Oliveira,
Axel Ruehl,
Piotr Masłowski,
Ingmar Hartl
Abstract:
We experimentally demonstrate in a difference-frequency generation mid-infrared frequency comb source the effect of temporal overlap between pump- and signal- pulse to the relative intensity noise (RIN) of the idler pulse. When scanning the temporal delay between our 130 fs long signal- and pump pulses, we observe a RIN minimum with a 3 dB width of 20 fs delay and an RIN increase of 20 dB in 40 fs…
▽ More
We experimentally demonstrate in a difference-frequency generation mid-infrared frequency comb source the effect of temporal overlap between pump- and signal- pulse to the relative intensity noise (RIN) of the idler pulse. When scanning the temporal delay between our 130 fs long signal- and pump pulses, we observe a RIN minimum with a 3 dB width of 20 fs delay and an RIN increase of 20 dB in 40 fs delay at the edges of this minimum. We also demonstrate active long-term stabilization of the mid-infrared frequency comb source to the temporal overlap setting corresponding to the lowest RIN operation point by an on-line RIN-detector and active feedback control of the pump-signal- pulse delay. This active stabilization set-up allowed us to dramatically increase the signal-to-noise ratio of mid-infrared absorption spectra.
△ Less
Submitted 4 April, 2019;
originally announced April 2019.
-
Absolute frequency determination of molecular transition in the Doppler regime at kHz level of accuracy
Authors:
K. Bielska,
S. Wojtewicz,
P. Morzynski,
P. Ablewski,
A. Cygan,
M. Bober,
M. Zawada,
R. Ciurylo,
P. Maslowski,
D. Lisak
Abstract:
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an…
▽ More
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an $^{88}$Sr optical atomic clock by an optical frequency comb.
△ Less
Submitted 16 August, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
Fibre-optic delivery of time and frequency to VLBI station
Authors:
P. Krehlik,
Ł. Buczek,
J. Kołodziej,
M. Lipiński,
Ł. Śliwczyński,
J. Nawrocki,
P. Nogaś,
A. Marecki,
E. Pazderski,
P. Ablewski,
M. Bober,
R. Ciuryło,
A. Cygan,
D. Lisak,
P. Masłowski,
P. Morzyński,
M. Zawada,
R. M. Campbell,
J. Pieczerak,
A. Binczewski,
K. Turza
Abstract:
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabi…
▽ More
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabilized, long-distance fibre-optic link. The T&F reference signals, traceable to international atomic timescale (TAI), are delivered to the VLBI station from a dedicated timekee** laboratory. Moreover, we describe a proof-of-concept experiment where the VLBI station is synchronized to a remote strontium optical lattice clock during the observation.
△ Less
Submitted 7 July, 2017; v1 submitted 28 March, 2017;
originally announced March 2017.
-
Optical Frequency Comb Fourier Transform Spectroscopy with Sub-Nominal Resolution - Principles and Implementation
Authors:
Lucile Rutkowski,
Piotr Maslowski,
Alexandra C. Johansson,
Amir Khodabakhsh,
Aleksandra Foltynowicz
Abstract:
Broadband precision spectroscopy is indispensable for providing high fidelity molecular parameters for spectroscopic databases. We have recently shown that mechanical Fourier transform spectrometers based on optical frequency combs can measure broadband high-resolution molecular spectra undistorted by the instrumental line shape (ILS) and with a highly precise frequency scale provided by the comb.…
▽ More
Broadband precision spectroscopy is indispensable for providing high fidelity molecular parameters for spectroscopic databases. We have recently shown that mechanical Fourier transform spectrometers based on optical frequency combs can measure broadband high-resolution molecular spectra undistorted by the instrumental line shape (ILS) and with a highly precise frequency scale provided by the comb. The accurate measurement of the power of the comb modes interacting with the molecular sample was achieved by acquiring single-burst interferograms with nominal resolution precisely matched to the comb mode spacing. Here we give a full theoretical description of this sub-nominal resolution method and describe in detail the experimental and numerical steps needed to retrieve ILS-free molecular spectra, i.e. with ILS-induced distortion below the noise level. We investigate the accuracy of the transition line centers retrieved by fitting to the absorption lines measured using this method. We verify the performance by measuring an ILS-free cavity-enhanced low-pressure spectrum of the 3ν1+ν3 band of CO2. We observe and quantify collisional narrowing of absorption line shape, for the first time with a comb-based spectroscopic technique. Thus retrieval of line shape parameters with accuracy not limited by the Voigt profile is now possible for entire absorption bands acquired simultaneously.
△ Less
Submitted 8 July, 2017; v1 submitted 13 December, 2016;
originally announced December 2016.
-
EELT-HIRES the high-resolution spectrograph for the E-ELT
Authors:
A. Marconi,
P. Di Marcantonio,
V. D'Odorico,
S. Cristiani,
R. Maiolino,
E. Oliva,
L. Origlia,
M. Riva,
L. Valenziano,
F. M. Zerbi,
M. Abreu,
V. Adibekyan,
C. Allende Prieto,
P. J. Amado,
W. Benz,
I. Boisse,
X. Bonfils,
F. Bouchy,
L. Buchhave,
D. Buscher,
A. Cabral,
B. L. Canto Martins,
A. Chiavassa,
J. Coelho,
L. B. Christensen
, et al. (48 additional authors not shown)
Abstract:
The first generation of E-ELT instruments will include an optical-infrared High Resolution Spectrograph, conventionally indicated as EELT-HIRES, which will be capable of providing unique breakthroughs in the fields of exoplanets, star and planet formation, physics and evolution of stars and galaxies, cosmology and fundamental physics. A 2-year long phase A study for EELT-HIRES has just started and…
▽ More
The first generation of E-ELT instruments will include an optical-infrared High Resolution Spectrograph, conventionally indicated as EELT-HIRES, which will be capable of providing unique breakthroughs in the fields of exoplanets, star and planet formation, physics and evolution of stars and galaxies, cosmology and fundamental physics. A 2-year long phase A study for EELT-HIRES has just started and will be performed by a consortium composed of institutes and organisations from Brazil, Chile, Denmark, France, Germany, Italy, Poland, Portugal, Spain, Sweden, Switzerland and United Kingdom. In this paper we describe the science goals and the preliminary technical concept for EELT-HIRES which will be developed during the phase A, as well as its planned development and consortium organisation during the study.
△ Less
Submitted 2 September, 2016;
originally announced September 2016.
-
Absolute measurement of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ clock transition in neutral ${}^{88}$Sr over the 330 km-long stabilized fibre optic link
Authors:
Piotr Morzynski,
Marcin Bober,
Dobroslawa Bartoszek-Bober,
Jerzy Nawrocki,
Przemyslaw Krehlik,
Lukasz Sliwczynski,
Marcin Lipinski,
Piotr Maslowski,
Agata Cygan,
Piotr Dunst,
Michal Garus,
Daniel Lisak,
Jerzy Zachorowski,
Wojciech Gawlik,
Czeslaw Radzewicz,
Roman Ciurylo,
Michal Zawada
Abstract:
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fi…
▽ More
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the ${}^{1}S_{0}$ - ${}^{3}P_{0}$ transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fibre optical link. The result was verified by series of measurements on two independent optical lattice clocks and agrees with recommendation of Bureau International des Poids et Mesures.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second
Authors:
M. Bober,
P. Morzyński,
A. Cygan,
D. Lisak,
P. Masłowski,
M. Prymaczek,
P. Wcisło,
P. Ablewski,
M. Piwiński,
S. Wójtewicz,
K. Bielska,
D. Bartoszek-Bober,
R. Trawiński,
M. Zawada,
R. Ciuryło,
J. Zachorowski,
M. Piotrowski,
W. Gawlik,
F. Ozimek,
C. Radzewicz
Abstract:
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice…
▽ More
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.
△ Less
Submitted 15 June, 2015;
originally announced June 2015.
-
Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs
Authors:
Piotr Maslowski,
Kevin F. Lee,
Alexandra C. Johansson,
Amir Khodabakhsh,
Grzegorz Kowzan,
Lucile Rutkowski,
Andrew A. Mills,
Christian Mohr,
Jie Jiang,
Martin E. Fermann,
Aleksandra Foltynowicz
Abstract:
Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum de…
▽ More
Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum delay range (Δ$_{max}$) of the interferometer, so acquisition of high-resolution spectra implies long measurement times and large instrument size. We overcome this limit by combining the Fourier transform spectrometer with an optical frequency comb and measuring the intensities of individual comb lines by precisely matching the Δ$_{max}$ to the comb line spacing. This allows measurements of absorption lines narrower than the nominal (optical path-limited) resolution without ringing effects from the instrumental lineshape and reduces the acquisition time and interferometer length by orders of magnitude.
△ Less
Submitted 28 May, 2015;
originally announced May 2015.
-
Absolute Frequency Measurement of Rubidium 5S-7S Two-Photon Transitions
Authors:
Piotr Morzynski,
Piotr Wcislo,
Piotr Ablewski,
Rafal Gartman,
Wojciech Gawlik,
Piotr Maslowski,
Bartlomiej Nagorny,
Filip Ozimek,
Czeslaw Radzewicz,
Marcin Witkowski,
Roman Ciurylo,
Michal Zawada
Abstract:
We report the absolute frequency measurements of rubidium 5S-7S two-photon transitions with a cw laser digitally locked to an atomic transition and referenced to an optical frequency comb. The narrow, two-photon transition, 5S-7S (760 nm) insensitive to first order in a magnetic field, is a promising candidate for frequency reference. The performed tests yield the transition frequency with accurac…
▽ More
We report the absolute frequency measurements of rubidium 5S-7S two-photon transitions with a cw laser digitally locked to an atomic transition and referenced to an optical frequency comb. The narrow, two-photon transition, 5S-7S (760 nm) insensitive to first order in a magnetic field, is a promising candidate for frequency reference. The performed tests yield the transition frequency with accuracy better than reported previously.
△ Less
Submitted 14 November, 2013;
originally announced November 2013.
-
Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared - application to trace detection of H2O2
Authors:
Aleksandra Foltynowicz,
Piotr Maslowski,
Adam J. Fleisher,
Bryce Bjork,
Jun Ye
Abstract:
We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high power Yb:fiber laser, a high finesse broadband cavity,…
▽ More
We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high power Yb:fiber laser, a high finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.75 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e., the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4 {\times} 10^-9 cm^-1 Hz^-1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9 {\times} 10^-11 cm^-1 Hz^-1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8% of water the detection limit is 130 ppb. Spectra of acetylene, methane and nitrous oxide at atmospheric pressure are also presented, and a line shape model is developed to simulate the experimental data.
△ Less
Submitted 6 February, 2012;
originally announced February 2012.
-
Quantum-noise-limited optical frequency comb spectroscopy
Authors:
Aleksandra Foltynowicz,
Ticijana Ban,
Piotr Maslowski,
Florian Adler,
Jun Ye
Abstract:
We achieve a quantum-noise-limited absorption sensitivity of 1.7/times10$^{-12}$ cm$^{-1}$ per spectral element at 400 s of acquisition time with cavity-enhanced frequency comb spectroscopy, the highest demonstrated for a comb-based technique. The system comprises a frequency comb locked to a high-finesse cavity and a fast-scanning Fourier transform spectrometer with an ultra-low-noise autobalanci…
▽ More
We achieve a quantum-noise-limited absorption sensitivity of 1.7/times10$^{-12}$ cm$^{-1}$ per spectral element at 400 s of acquisition time with cavity-enhanced frequency comb spectroscopy, the highest demonstrated for a comb-based technique. The system comprises a frequency comb locked to a high-finesse cavity and a fast-scanning Fourier transform spectrometer with an ultra-low-noise autobalancing detector. Spectra with a signal-to-noise ratio above 1000 and a resolution of 380 MHz are acquired within a few seconds. The measured absorption lineshapes are in excellent agreement with theoretical predictions.
△ Less
Submitted 30 September, 2011;
originally announced October 2011.
-
Mid-Infrared Frequency Comb Fourier Transform Spectrometer
Authors:
Florian Adler,
Piotr Masłowski,
Aleksandra Foltynowicz,
Kevin C. Cossel,
Travis C. Briles,
Ingmar Hartl,
Jun Ye
Abstract:
Optical frequency-comb-based-high-resolution spectrometers offer enormous potential for spectroscopic applications. Although various implementations have been demonstrated, the lack of suitable mid-infrared comb sources has impeded explorations of molecular fingerprinting. Here we present for the first time a frequency-comb Fourier transform spectrometer operating in the 2100-to-3700-cm-1 spectral…
▽ More
Optical frequency-comb-based-high-resolution spectrometers offer enormous potential for spectroscopic applications. Although various implementations have been demonstrated, the lack of suitable mid-infrared comb sources has impeded explorations of molecular fingerprinting. Here we present for the first time a frequency-comb Fourier transform spectrometer operating in the 2100-to-3700-cm-1 spectral region that allows fast and simultaneous acquisitions of broadband absorption spectra with up to 0.0056 cm-1 resolution. We demonstrate part-per-billion detection limits in 30 seconds of integration time for various important molecules including methane, ethane, isoprene, and nitrous oxide. Our system enables precise concentration measurements even in gas mixtures that exhibit continuous absorption bands, and it allows detection of molecules at levels below the noise floor via simultaneous analysis of multiple spectral features. This system represents a near real-time, high-resolution, high-bandwidth mid-infrared spectrometer which is ready to replace traditional Fourier transform spectrometers for many applications in trace gas detection, atmospheric science, and medical diagnostics.
△ Less
Submitted 24 September, 2010; v1 submitted 5 July, 2010;