-
Multiscale Monte Carlo simulations of gold nanoparticle dose-enhanced radiotherapy II. Cellular dose enhancement within macroscopic tumor models
Authors:
Martin P. Martinov,
Elizabeth M. Fletcher,
Rowan M. Thomson
Abstract:
Purpose: To develop and apply multiscale Monte Carlo (MC) simulations to assess variations in nucleus and cytoplasm dose enhancement factors (n,cDEFs) over tumor-scale volumes. Methods: The intrinsic variation of n,cDEFs (due to variations in local gold concentration and cell/nucleus size) are estimated via MC modeling of varied cellular GNP uptake and cell/nucleus sizes. Then, a Heterogeneous Mul…
▽ More
Purpose: To develop and apply multiscale Monte Carlo (MC) simulations to assess variations in nucleus and cytoplasm dose enhancement factors (n,cDEFs) over tumor-scale volumes. Methods: The intrinsic variation of n,cDEFs (due to variations in local gold concentration and cell/nucleus size) are estimated via MC modeling of varied cellular GNP uptake and cell/nucleus sizes. Then, a Heterogeneous MultiScale (HetMS) model is implemented by combining detailed models of populations of cells containing GNPs with simplified tissue models to evaluate n,cDEFs. Simulations of tumors with spatially-uniform and -varying gold concentrations are performed to determine n,cDEFs as a function of distance from the source. All simulations are performed for three different GNP configurations: GNPs distributed around the nucleus or packed into one or four endosome(s). Results: Intrinsic variations in n,cDEFs can be substantial with changes in GNP uptake and cell/nucleus radii. In HetMS models of tumors, sub-unity n,cDEFs (dose decreases) can occur for low energies and high gold concentrations due to attenuation of primary photons through the gold. In HetMS simulations of tumors with spatially-uniform gold concentrations, n,cDEFs decrease with depth into the tumor as photons are attenuated, with relative differences between GNP models remaining approximately constant with depth in the tumor. Similar initial n,cDEF decreases with radius are seen in tumors with spatially-varying gold concentrations, but n,cDEFs for all configurations converge to a single value for each energy as gold concentration reaches zero. Conclusions: These results demonstrate that cellular doses are highly sensitive to cell/nucleus size, GNP intracellular distribution, gold concentration, and cell position in the tumor. This work demonstrates the importance of proper choice of computational model when simulating GNPT scenarios.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
Multiscale Monte Carlo simulations of gold nanoparticle dose-enhanced radiotherapy I. Cellular dose enhancement in microscopic models
Authors:
Martin P. Martinov,
Elizabeth M. Fletcher,
Rowan M. Thomson
Abstract:
Purpose: The introduction of Gold NanoParticles (GNPs) in radiotherapy requires consideration of GNP size, location, and quantity, and more, as well as beam quality. The work is presented in two parts, with Part I (this work) investigating accurate and efficient MC modeling to calculate nucleus and cytoplasm Dose Enhancement Factors (n,cDEFs). Part II then evaluates cell dose enhancement factors a…
▽ More
Purpose: The introduction of Gold NanoParticles (GNPs) in radiotherapy requires consideration of GNP size, location, and quantity, and more, as well as beam quality. The work is presented in two parts, with Part I (this work) investigating accurate and efficient MC modeling to calculate nucleus and cytoplasm Dose Enhancement Factors (n,cDEFs). Part II then evaluates cell dose enhancement factors across macroscopic length scales. Methods: Different methods of modeling gold within cells are compared: a contiguous volume of either pure gold or gold-tissue mixture or discrete GNPs. MC simulations with EGSnrc are performed to calculate n,cDEF for a cell considering 10 to 370 keV incident photons, gold concentrations from 4 to 24~mg of gold per gram, and three different GNP configurations: GNPs distributed around the surface of the nucleus or packed into one or four endosomes. Results: n,cDEFs are sensitive to the model of gold in the cell, with differences of up to 17% observed between models. Across cell/nucleus radii, source energies, and gold concentrations, n,cDEF are highest for GNPs in the perinuclear configuration, compared with GNPs in endosomes. Across all simulations of the default cell, nDEFs and cDEFs range from one to 6.83 and 3.87, respectively. If the cell size is changed, much higher n,cDEFs are observed. n,cDEF are maximized at photon energies at or just above the K- or L-edges of gold. Conclusions: This work demonstrates many physics trends on DEFs at the cellular level, including that cellular DEFs are sensitive to gold modeling approach, GNP configuration, cell/nucleus size, gold concentration, and incident source energy. These data will allow one to optimize or estimate DEF using not only GNP uptake, but account for incident photon energy and intracellular configuration of GNPs. Part II will expand the investigation, applying the cell model in cm-scale phantoms.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources
Authors:
Habib Safigholi,
Marc J. P. Chamberland,
Randle E. P. Taylor,
Martin P. Martinov,
D. W. O. Rogers,
Rowan M. Thomson
Abstract:
PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy (HE, $\geq50$~keV) brachytherapy sources using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2…
▽ More
PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy (HE, $\geq50$~keV) brachytherapy sources using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary and Scatter Separated (PSS) dose tables, and mean photon energies esca** each source. The database also documents the source models which will be freely distributed with egs_brachy. ACQUISITION AND VALIDATION METHODS: Datasets are calculated after a recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Air kerma per history is calculated in a 10x10x0.05 cm3 voxel located 100 cm from the source along the transverse axis and then corrected for the lateral and thickness dimensions of the scoring voxel to give the air kerma on the central axis at a point 100cm from the source's mid-point. Full-scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. For validation, data are compared to those from CLRP_TG43v1 and published data. DATA FORMAT AND ACCESS: Data are available at https://physics.carleton.ca/clrp/egs_brachy/seed_database_HDRv2 or http://doi.org/10.22215/clrp/tg43v2. POTENTIAL APPLICATIONS: The CLRP_TG43v2 database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more precise and in some cases more accurate Monte Carlo TG-43 dose calculation parameters, as well as fully benchmarked and described source models which are distributed with egs_brachy.
△ Less
Submitted 7 December, 2022;
originally announced December 2022.
-
Fast full patient and radioisotope Monte Carlo simulations of targeted radionuclide therapy: introducing egs_mird
Authors:
Martin P. Martinov,
Chidera Opera,
Rowan M. Thomson,
Ting-Yim Lee
Abstract:
BACKGROUND: Targeted Radionuclide Therapy (TRT) is a fast-growing field garnering much interest, however, dosimetry calculation techniques remain relatively simple. PURPOSE: To introduce egs_mird, a new Monte Carlo application built in EGSnrc which allows users to model full patient tissue and density (using clinical CT images) and radionuclide distribution (using clinical PET images) for fast and…
▽ More
BACKGROUND: Targeted Radionuclide Therapy (TRT) is a fast-growing field garnering much interest, however, dosimetry calculation techniques remain relatively simple. PURPOSE: To introduce egs_mird, a new Monte Carlo application built in EGSnrc which allows users to model full patient tissue and density (using clinical CT images) and radionuclide distribution (using clinical PET images) for fast and detailed TRT dose calculation. METHODS: The novel application egs_mird is introduced, including its structure and variation reduction approaches. A new egs++ source class egs_internal_source and a modified version of egs_radionuclide_source are described. The new code is compared to other MC calculations of S-value kernels, along with self-validation using the electron Fano test. Full patient prostate 177Lu TRT cancer treatment simulations are performed using a single set of patient DICOM CT and [18F]-DCFPyL PET data. RESULTS: Good agreement is found between S-value kernels calculated using egs_mird and those found in the literature. The Fano test is satisfied to 0.1%. Patient prostate, rectum, bone marrow, and bladder dose volume histogram results did not vary significantly when using the track-length estimator and not modelling electron transport, modelling bone marrow explicitly (rather than using generic tissue compositions), and reducing activity to voxels containing partial or full calcifications to half or none, respectively. Simulations using the track-length estimator can be completed in under 15 minutes. CONCLUSION: This work shows egs mird to be a reliable MC code for computing TRT doses as realistically as the patient CT and PET data allow, supporting the use of egs mird for dose calculations in TRT.
△ Less
Submitted 4 April, 2022;
originally announced April 2022.
-
Heterogeneous multiscale Monte Carlo simulations for gold nanoparticle radiosensitization
Authors:
Martin P. Martinov,
Rowan M. Thomson
Abstract:
To introduce the heterogeneous multiscale (HetMS) model for Monte Carlo simulations of gold nanoparticle dose-enhanced radiation therapy (GNPT), a model characterized by its varying levels of detail on different length scales within a single phantom; to apply the HetMS model in two different scenarios relevant for GNPT and to compare computed results with others published. The HetMS model is imple…
▽ More
To introduce the heterogeneous multiscale (HetMS) model for Monte Carlo simulations of gold nanoparticle dose-enhanced radiation therapy (GNPT), a model characterized by its varying levels of detail on different length scales within a single phantom; to apply the HetMS model in two different scenarios relevant for GNPT and to compare computed results with others published. The HetMS model is implemented in EGSnrc; the code is tested via comparisons with published data from independent gold nanoparticle (GNP) simulations. Two distinct scenarios for the HetMS model are considered: (1) monoenergetic photon beams incident on a large cylinder; (2) isotropic point source at the center of a large sphere with GNPs diffusing from the center. Dose enhancement factors (DEFs) are compared for different source energies, depths, gold concentrations, GNP sizes, and modeling assumptions. Simulation efficiencies are investigated. The HetMS MC simulations account for the competing effects of photon fluence perturbation coupled with enhanced local energy deposition. DEFs are most sensitive to these effects for lower source energies, varying with distance from the source; DEFs below unity can occur at energies relevant for brachytherapy. Compared to discrete modeling of GNPs throughout the gold-containing volume, efficiencies are enhanced by up to a factor of 122 with the HetMS approach. For the spherical phantom, DEFs vary with time for diffusion, radionuclide, and radius. By combining geometric models of varying complexity on different length scales within a single simulation, the HetMS model can effectively account for both macroscopic and microscopic effects. Efficiency gains with the HetMS approach enable diverse calculations which would otherwise be prohibitively long. The HetMS model may be extended to diverse scenarios relevant for GNPT, providing further avenues for research and development.
△ Less
Submitted 29 July, 2020;
originally announced July 2020.
-
Update of the CLRP TG-43 parameter database for low-energy brachytherapy sources
Authors:
Habib Safigholi,
Marc J. P. Chamberland,
Randle E. P. Taylor,
Christian H. Allen,
Martin P. Martinov,
D. W. O. Rogers,
Rowan M. Thomson
Abstract:
PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (Pd-103, I-125, Cs-131). A…
▽ More
PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (Pd-103, I-125, Cs-131). A comprehensive set of TG-43 parameters is calculated, including dose-rate constants, radial dose functions with functional fitting parameters, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary-Scatter separation dose tables (for some sources), and mean photon energies. The database also documents the source models which will become part of the egs_brachy distribution. METHODS: Datasets are calculated after a systematic recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Full scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. New statistical uncertainties of source volume corrections for phantom voxels which overlap with brachytherapy sources are implemented in egs_brachy, and all CLRPv2 data include these uncertainties. For validation, data are compared to CLRPv1 and other data in the literature. DATA ACCESS/FORMAT: Data are available at https://physics.carleton.ca/ clrp/egs_brachy/seed_database_v2. As well as being presented graphically in comparisons to previous calculations, data are available in Excel (.xlsx) spreadsheets for each source. APPLICATIONS: The database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more accurate TG-43 dose evaluation parameters, as well as fully-benchmarked source models distributed with egs_brachy.
△ Less
Submitted 6 May, 2020;
originally announced May 2020.
-
Taking EGSnrc to new lows: Development of egs++ lattice geometry and testing with microscopic
Authors:
Martin P. Martinov,
Rowan M. Thomson
Abstract:
Purpose: This work introduces a new lattice geometry library, egs_lattice, into the EGSnrc Monte Carlo code, which can be used for both modeling very large (previously unfeasible) quantities of geometries and establishing recursive boundary conditions. The reliability of egs_lattice, as well as EGSnrc in general, is cross-validated and tested. Methods: New Bravais, cubic, and hexagonal lattice geo…
▽ More
Purpose: This work introduces a new lattice geometry library, egs_lattice, into the EGSnrc Monte Carlo code, which can be used for both modeling very large (previously unfeasible) quantities of geometries and establishing recursive boundary conditions. The reliability of egs_lattice, as well as EGSnrc in general, is cross-validated and tested. Methods: New Bravais, cubic, and hexagonal lattice geometries are defined in egs_lattice and their transport algorithms are described. Simulations of cells and Gold NanoParticle (GNP) containing cavities are implemented to compare to published Geant4-DNA and PENELOPE results. Recursive boundary conditions, implemented through a cubic lattice, are used to perform electron Fano cavity tests. Results: Lattices are successfully implemented in EGSnrc. EGSnrc calculated doses to cell cytoplasm and nucleus when irradiated by an internal electron source with a median difference of 0.6% compared to Geant4-DNA. EGSnrc calculated the ratio of dose to a microscopic cavity containing GNPs over dose to a cavity containing a homogeneous mixture of gold, and results generally agree (within 1%) with PENELOPE. The Fano test is passed (sub-0.1%) for all energies/ cells considered. Additionally, the recursive boundary conditions used for the Fano test provided a factor of over a million increase in efficiency in some cases. Conclusions: The egs_lattice geometry library, currently available as a pull request on the EGSnrc GitHub develop branch, is now freely accessible as open-source code. Lattice geometry implementations cross-validated with independent simulations in other MC codes and verified with the electron Fano cavity test demonstrate not only the reliability of egs_lattice, but, by extension, EGSnrc's ability to simulate transport in nanometer geometries and score in microscopic cavities.
△ Less
Submitted 10 March, 2020;
originally announced March 2020.