-
Adapting a General Purpose Social Robot for Paediatric Rehabilitation through In-situ Design
Authors:
Felip MartÃ,
Jo Butchart,
Sarah Knight,
Adam Scheinberg,
Lisa Wise,
Leon Sterling,
Chris McCarthy
Abstract:
Socially Assistive Robots (SARs) offer great promise for improving outcomes in paediatric rehabilitation. However, the design of software and interactive capabilities for SARs must be carefully considered in the context of their intended clinical use. While previous work has explored specific roles and functionalities to support paediatric rehabilitation, few have considered the design of such cap…
▽ More
Socially Assistive Robots (SARs) offer great promise for improving outcomes in paediatric rehabilitation. However, the design of software and interactive capabilities for SARs must be carefully considered in the context of their intended clinical use. While previous work has explored specific roles and functionalities to support paediatric rehabilitation, few have considered the design of such capabilities in the context of ongoing clinical deployment. In this paper we present a two-phase In-situ design process for SARs in health care, emphasising stakeholder engagement and on-site development. We explore this in the context of develo** the humanoid social robot NAO as a socially assistive rehabilitation aid for children with cerebral palsy. We present and evaluate our design process, outcomes achieved, and preliminary results from ongoing clinical testing with 9 patients and 5 therapists over 14 sessions. We argue that our in-situ Design methodology has been central to the rapid and successful deployment of our system.
△ Less
Submitted 7 March, 2018; v1 submitted 15 May, 2017;
originally announced May 2017.
-
The cyclotron gas stopper project at the NSCL
Authors:
C. Guenaut,
G. Bollen,
S. Chouhan,
F. Marti,
D. J. Morrissey,
D. Lawton,
J. Ottarson,
G. K. Pang,
S. Schwarz,
B. M. Sherrill,
M. Wada,
A. F. Zeller
Abstract:
Gas stop** is becoming the method of choice for converting beams of rare isotopes obtained via projectile fragmentation and in-flight separation into low-energy beams. These beams allow ISOL-type experiments, such as mass measurements with traps or laser spectroscopy, to be performed with projectile fragmentation products. Current gas stopper systems for high-energy beams are based on linear g…
▽ More
Gas stop** is becoming the method of choice for converting beams of rare isotopes obtained via projectile fragmentation and in-flight separation into low-energy beams. These beams allow ISOL-type experiments, such as mass measurements with traps or laser spectroscopy, to be performed with projectile fragmentation products. Current gas stopper systems for high-energy beams are based on linear gas cells filled with 0.1-1 bar of helium. While already used successfully for experiments, it was found that space charge effects induced by the ionization of the helium atoms during the stop** process pose a limit on the maximum beam rate that can be used. Furthermore, the extraction time of stopped ions from these devices can exceed 100 ms causing substantial decay losses for very short-lived isotopes. To avoid these limitations, a new type of gas stopper is being developed at the NSCL/MSU. The new system is based on a cyclotron-type magnet with a stop** chamber filled with Helium buffer gas at low pressure. RF-guiding techniques are used to extract the ions. The space charge effects are considerably reduced by the large volume and due to a separation between the stop** region and the region of highest ionization. Cyclotron gas stopper systems of different sizes and with different magnetic field strengths and field shapes are presently investigated.
△ Less
Submitted 26 March, 2007;
originally announced March 2007.
-
Niobium Quarter-Wave Resonator Development for The Rare Isotope Accelerator
Authors:
W. Hartung,
J. Bierwagen,
S. Bricker,
J. Colthorp,
C. Compton,
T. Grimm,
S. Hitchcock,
F. Marti,
L. Saxton,
R. C. York,
A. Facco,
V. Zviagintsev
Abstract:
Two superconducting quarter-wave resonator (QWR) prototypes have been fabricated and tested. They operate at 80.5 MHz and 161 MHz and are optimised for beta = 0.085 and beta = 0.16, respectively. The prototypes are simplified versions without integrated helium vessels. In the first RF tests, the beta = 0.085 QWR reached a peak surface electric field (Ep) in excess of 30 MV/m, with an intrinsic q…
▽ More
Two superconducting quarter-wave resonator (QWR) prototypes have been fabricated and tested. They operate at 80.5 MHz and 161 MHz and are optimised for beta = 0.085 and beta = 0.16, respectively. The prototypes are simplified versions without integrated helium vessels. In the first RF tests, the beta = 0.085 QWR reached a peak surface electric field (Ep) in excess of 30 MV/m, with an intrinsic quality factor (Q0) in excess of 1E9 at the design field of Ep = 20 MV/m. The beta = 0.16 QWR reached Ep = 20 MV/m with Q0 = 2.5E9. It is suspected that the performance of the latter cavity can be improved via better cooling of the Nb tuning plate and a better RF contact between the plate and the outer conductor.
△ Less
Submitted 4 December, 2004;
originally announced December 2004.
-
Analysis of a Cyclotron Based 400 MeV/u Driver System for a Radioactive Beam Facility
Authors:
F. Marti,
R. C. York,
H. Blosser,
M. M. Gordon,
D. Gorelov,
T. Grimm,
D. Johnson,
P. Miller,
E. Pozdeyev,
J. Vincent,
X. Wu,
A. Zeller
Abstract:
The creation of intense radioactive beams requires intense and energetic primary beams. A task force analysis of this subject recommended an acceleration system capable of 400 MeV/u uranium at 1 particle uA as an appropriate driver for such a facility. The driver system should be capable of accelerating lighter ions at higher intensity such that a constant final beam power (~100kW) is maintained…
▽ More
The creation of intense radioactive beams requires intense and energetic primary beams. A task force analysis of this subject recommended an acceleration system capable of 400 MeV/u uranium at 1 particle uA as an appropriate driver for such a facility. The driver system should be capable of accelerating lighter ions at higher intensity such that a constant final beam power (~100kW) is maintained. This document is a more detailed follow on to the previous analysis of such a system incorporating a cyclotron. The proposed driver pre-acceleration system consists of an ion source, radio frequency quadrupole, and linac chain capable of producing a final energy of 30 MeV/u and a charge (Q) to mass (A) of Q/A ~1/3. This acceleration system would be followed by a Separated Sector Cyclotron with a final output energy of 400 MeV/u. This system provides a more cost-effective solution in terms of initial capital investment as well as of operation compared to a fully linac system with the same primary beam output parameters.
△ Less
Submitted 20 August, 1999;
originally announced August 1999.
-
Experimental evidence for fast cluster formation of chain oxygen vacancies in YBa2Cu3O7-d being at the origin of the fishtail anomaly
Authors:
Andreas Erb,
Alfred A. Manuel,
Marc Dhalle,
Frank Marti,
Jean-Yves Genoud,
Bernard Revaz,
Alain Junod,
Dharmavaram Vasumathi,
Shoji Ishibashi,
Abhay Shukla,
Eric Walker,
Oystein Fischer,
Rene Fluekiger,
Riccardo Pozzi,
Mihael Mali,
Detlef Brinkmann
Abstract:
We report on three different and complementary measurements, namely magnetisation measurements, positron annihilation spectroscopy and NMR measurements, which give evidence that the formation of oxygen vacancy clusters is on the origin of the fishtail anomaly in YBa2Cu3O7-d. While in the case of YBa2Cu3O7.0 the anomaly is intrinsically absent, it can be suppressed in the optimally doped state wh…
▽ More
We report on three different and complementary measurements, namely magnetisation measurements, positron annihilation spectroscopy and NMR measurements, which give evidence that the formation of oxygen vacancy clusters is on the origin of the fishtail anomaly in YBa2Cu3O7-d. While in the case of YBa2Cu3O7.0 the anomaly is intrinsically absent, it can be suppressed in the optimally doped state where vacancies are present. We therefore conclude that the single vacancies or point defects can not be responsible for this anomaly but that clusters of oxygen vacancies are on its origin.
△ Less
Submitted 19 May, 1998;
originally announced May 1998.