Development of a real-time tritium-in-water monitor
Authors:
C. D. R. Azevedo,
A. Baeza,
E. Chauveau,
J. A. Corbacho,
J. Díaz,
J. Domange,
C. Marquet,
M. Martínez-Roig,
F. Piquemal,
D. Prado,
J. F. C. A. Veloso,
N. Yahlali
Abstract:
In this paper, we report the development and performance of a detector module envisaging a tritium-in-water real-time activity monitor. The monitor is based on modular detection units whose number can be chosen according to the required sensitivity. The full system is being designed to achieve a \emph{Minimum Detectable Activity} (\emph{MDA}) of 100\,Bq/L of tritium-in-water activity which is the…
▽ More
In this paper, we report the development and performance of a detector module envisaging a tritium-in-water real-time activity monitor. The monitor is based on modular detection units whose number can be chosen according to the required sensitivity. The full system is being designed to achieve a \emph{Minimum Detectable Activity} (\emph{MDA}) of 100\,Bq/L of tritium-in-water activity which is the limit established by the E.U. Council Directive 2013/51/Euratom for water intended for human consumption. The same system can be used as a real-time pre-alert system for nuclear power plant regarding tritium-in water environmental surveillance. The first detector module was characterized, commissioned and installed immediately after the discharge channel of the Arrocampo dam (Almaraz nuclear power plant, Spain) on the Tagus river. Due to the high sensitivity of the single detection modules, the system requires radioactive background mitigation techniques through the use of active and passive shielding. We have extrapolated a \emph{MDA} of 3.6\,kBq/L for a single module being this value limited by the cosmic background. The obtained value for a single module is already compatible with a real-time environmental surveillance and pre-alert system. Further optimization of the single-module sensitivity will imply the reduction of the number of modules and the cost of the detector system.
△ Less
Submitted 5 December, 2023; v1 submitted 22 February, 2022;
originally announced February 2022.
-
Simulation results on a real-time in water tritium monitor
Authors:
C. D. R. Azevedo,
A. Baeza,
E. Chauveau,
J. A. Corbacho,
J. Díaz,
J. Domange,
C. Marquet,
M. Martínez-Roig,
F. Piquemal,
J. F. C. A. Veloso,
N. Yahlali
Abstract:
In this work we present simulation results for a modular tritium in-water real-time monitor. The system allows for scalability in order to achieve the required sensitivity. The modules are composed by 340 uncladed scintillating fibers immersed in water and 2 photosensors for light readout. Light yield and Birks' coefficient uncertainties for low energy beta particles is discussed. A study of the d…
▽ More
In this work we present simulation results for a modular tritium in-water real-time monitor. The system allows for scalability in order to achieve the required sensitivity. The modules are composed by 340 uncladed scintillating fibers immersed in water and 2 photosensors for light readout. Light yield and Birks' coefficient uncertainties for low energy beta particles is discussed. A study of the detection efficiency according to the fiber length is presented. Discussion on the system requirements and background mitigation for a device with sensitivity of 100\,Bq/L, required to comply with the European directive 2013/51/Euratom, is presented. Due to the low energetic beta emission from tritium a detection efficiency close to 3.3\% was calculated for a single 2\,mm round fiber.
△ Less
Submitted 20 May, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance
Authors:
C. D. R. Azevedo,
A. Baeza,
M. Bras,
T. Camara,
C. Cerna,
E. Chauveau,
J. M. Gil,
J. A. Corbacho,
V. Delgado,
J. Díaz,
J. Domange,
C. Marquet,
M. Martínez-Roig,
A. Moreno,
F. Piquemal,
A. Rodríguez,
J. Rodríguez,
C. Roldan,
J. F. C. A. Veloso,
N. Yahlali
Abstract:
In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in wa…
▽ More
In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in water for human consumption to be lower than 100 Bq/L. Tritium levels in the cooling water of nuclear power plants in normal operation are much higher than the levels caused by the natural and cosmogenic components, and may easily surmount the limit required by the Directive. The current liquid-scintillation measuring systems in environmental radioactivity laboratories are sensitive to such low levels, but they are not suitable for real-time monitoring. Moreover, there is no currently available device with enough sensitivity and monitoring capabilities that could be used for surveillance of the cooling water of nuclear power plants. A detector system based on scintillation fibers read out by photomultiplier tubes (PMTs) or silicon photomultiplier (SiPM) arrays is under development for in-water tritium measurement. This detector will be installed in the vicinity of Almaraz nuclear power plant (Spain) in Spring 2019. An overview of the project development and the results of first prototypes are presented.
△ Less
Submitted 14 February, 2019;
originally announced February 2019.