-
Using low-frequency scatter-broadening measurements for precision estimates of dispersion measures
Authors:
Jaikhomba Singha,
Bhal Chandra Joshi,
M. A. Krishnakumar,
Fazal Kareem,
Adarsh Bathula,
Churchil Dwivedi,
Shebin Jose Jacob,
Shantanu Desai,
Pratik Tarafdar,
P. Arumugam,
Swetha Arumugam,
Manjari Bagchi,
Neelam Dhanda Batra,
Subhajit Dandapat,
Debabrata Deb,
Jyotijwal Debnath,
A Gopakumar,
Yashwant Gupta,
Shinnosuke Hisano,
Ryo Kato,
Tomonosuke Kikunaga,
Piyush Marmat,
K. Nobleson,
Avinash K. Paladi,
Arul Pandian B.
, et al. (6 additional authors not shown)
Abstract:
A pulsar's pulse profile gets broadened at low frequencies due to dispersion along the line of sight or due to multi-path propagation. The dynamic nature of the interstellar medium makes both of these effects time-dependent and introduces slowly varying time delays in the measured times-of-arrival similar to those introduced by passing gravitational waves. In this article, we present a new method…
▽ More
A pulsar's pulse profile gets broadened at low frequencies due to dispersion along the line of sight or due to multi-path propagation. The dynamic nature of the interstellar medium makes both of these effects time-dependent and introduces slowly varying time delays in the measured times-of-arrival similar to those introduced by passing gravitational waves. In this article, we present a new method to correct for such delays by obtaining unbiased dispersion measure (DM) measurements by using low-frequency estimates of the scattering parameters. We evaluate this method by comparing the obtained DM estimates with those, where scatter-broadening is ignored using simulated data. A bias is seen in the estimated DMs for simulated data with pulse-broadening with a larger variability for a data set with a variable frequency scaling index, $α$, as compared to that assuming a Kolmogorov turbulence. Application of the proposed method removes this bias robustly for data with band averaged signal-to-noise ratio larger than 100. We report, for the first time, the measurements of the scatter-broadening time and $α$ from analysis of PSR J1643$-$1224, observed with upgraded Giant Metrewave Radio Telescope as part of the Indian Pulsar Timing Array experiment. These scattering parameters were found to vary with epoch and $α$ was different from that expected for Kolmogorov turbulence. Finally, we present the DM time-series after application of the new technique to PSR J1643$-$1224.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
Nanohertz Gravitational Wave Astronomy during the SKA Era: An InPTA perspective
Authors:
Bhal Chandra Joshi,
Achamveedu Gopakumar,
Arul Pandian,
Thiagaraj Prabu,
Lankeswar Dey,
Manjari Bagchi,
Shantanu Desai,
Pratik Tarafdar,
Prerna Rana,
Yogesh Maan,
Neelam Dhanda Batra,
Raghav Girgaonkar,
Nikita Agarwal,
Paramasivan Arumugam,
Sarmistha Banik,
Avishek Basu,
Adarsh Bathula,
Subhajit Dandapat,
Yashwant Gupta,
Shinnosuke Hisano,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Neel Kolhe,
M. A. Krishnakumar
, et al. (12 additional authors not shown)
Abstract:
Decades long monitoring of millisecond pulsars, which exhibit highly stable rotational periods, in pulsar timing array experiments is on the threshold of discovering nanohertz stochastic gravitational wave background. This paper describes the Indian Pulsar timing array (InPTA) experiment, which employs the upgraded Giant Metrewave Radio Telescope (uGMRT) for timing an ensemble of millisecond pulsa…
▽ More
Decades long monitoring of millisecond pulsars, which exhibit highly stable rotational periods, in pulsar timing array experiments is on the threshold of discovering nanohertz stochastic gravitational wave background. This paper describes the Indian Pulsar timing array (InPTA) experiment, which employs the upgraded Giant Metrewave Radio Telescope (uGMRT) for timing an ensemble of millisecond pulsars for this purpose. We highlight InPTA's observation strategies and analysis methods, which are relevant for a future PTA experiment with the more sensitive Square Kilometer Array (SKA) telescope. We show that the unique multi-sub-array multi-band wide-bandwidth frequency coverage of the InPTA provides Dispersion Measure estimates with unprecedented precision for PTA pulsars, e.g., ~ 2 x 10{-5} pc-cm{-3} for PSR J1909-3744. Configuring the SKA-low and SKA-mid as two and four sub-arrays respectively, it is shown that comparable precision is achievable, using observation strategies similar to those pursued by the InPTA, for a larger sample of 62 pulsars requiring about 26 and 7 hours per epoch for the SKA-mid and the SKA-low telescopes respectively. We also review the ongoing efforts to develop PTA-relevant general relativistic constructs that will be required to search for nanohertz gravitational waves from isolated super-massive black hole binary systems like blazar OJ 287. These efforts should be relevant to pursue persistent multi-messenger gravitational wave astronomy during the forthcoming era of the SKA telescope, the Thirty Meter Telescope, and the next-generation Event Horizon Telescope.
△ Less
Submitted 13 July, 2022;
originally announced July 2022.
-
The Indian Pulsar Timing Array: First data release
Authors:
Pratik Tarafdar,
Nobleson K.,
Prerna Rana,
Jaikhomba Singha,
M. A. Krishnakumar,
Bhal Chandra Joshi,
Avinash Kumar Paladi,
Neel Kolhe,
Neelam Dhanda Batra,
Nikita Agarwal,
Adarsh Bathula,
Subhajit Dandapat,
Shantanu Desai,
Lankeswar Dey,
Shinnosuke Hisano,
Prathamesh Ingale,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Piyush Marmat,
B. Arul Pandian,
T. Prabu,
Aman Srivastava,
Mayuresh Surnis,
Sai Chaitanya Susarla
, et al. (13 additional authors not shown)
Abstract:
We present the pulse arrival times and high-precision dispersion measure estimates for 14 millisecond pulsars observed simultaneously in the 300-500 MHz and 1260-1460 MHz frequency bands using the upgraded Giant Metrewave Radio Telescope (uGMRT). The data spans over a baseline of 3.5 years (2018-2021), and is the first official data release made available by the Indian Pulsar Timing Array collabor…
▽ More
We present the pulse arrival times and high-precision dispersion measure estimates for 14 millisecond pulsars observed simultaneously in the 300-500 MHz and 1260-1460 MHz frequency bands using the upgraded Giant Metrewave Radio Telescope (uGMRT). The data spans over a baseline of 3.5 years (2018-2021), and is the first official data release made available by the Indian Pulsar Timing Array collaboration. This data release presents a unique opportunity for investigating the interstellar medium effects at low radio frequencies and their impact on the timing precision of pulsar timing array experiments. In addition to the dispersion measure time series and pulse arrival times obtained using both narrowband and wideband timing techniques, we also present the dispersion measure structure function analysis for selected pulsars. Our ongoing investigations regarding the frequency dependence of dispersion measures have been discussed. Based on the preliminary analysis for five millisecond pulsars, we do not find any conclusive evidence of chromaticity in dispersion measures. Data from regular simultaneous two-frequency observations are presented for the first time in this work. This distinctive feature leads us to the highest precision dispersion measure estimates obtained so far for a subset of our sample. Simultaneous multi-band uGMRT observations in Band 3 and Band 5 are crucial for high-precision dispersion measure estimation and for the prospect of expanding the overall frequency coverage upon the combination of data from the various Pulsar Timing Array consortia in the near future. Parts of the data presented in this work are expected to be incorporated into the upcoming third data release of the International Pulsar Timing Array.
△ Less
Submitted 25 October, 2022; v1 submitted 18 June, 2022;
originally announced June 2022.
-
Low-frequency wideband timing of InPTA pulsars observed with the uGMRT
Authors:
K Nobleson,
Nikita Agarwal,
Raghav Girgaonkar,
Arul Pandian,
Bhal Chandra Joshi,
M A Krishnakumar,
Abhimanyu Susobhanan,
Shantanu Desai,
T Prabu,
Adarsh Bathula,
Timothy T Pennucci,
Sarmistha Banik,
Manjari Bagchi,
Neelam Dhanda Batra,
Arpita Choudhary,
Subhajit Dandapat,
Lankeswar Dey,
Yashwant Gupta,
Shinnosuke Hisano,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Neel Kolhe,
Yogesh Maan,
Piyush Marmat
, et al. (7 additional authors not shown)
Abstract:
High-precision measurements of the pulsar dispersion measure (DM) are possible using telescopes with low-frequency wideband receivers. We present an initial study of the application of the wideband timing technique, which can simultaneously measure the pulsar times of arrival (ToAs) and DMs, for a set of five pulsars observed with the upgraded Giant Metrewave Radio Telescope (uGMRT) as part of the…
▽ More
High-precision measurements of the pulsar dispersion measure (DM) are possible using telescopes with low-frequency wideband receivers. We present an initial study of the application of the wideband timing technique, which can simultaneously measure the pulsar times of arrival (ToAs) and DMs, for a set of five pulsars observed with the upgraded Giant Metrewave Radio Telescope (uGMRT) as part of the Indian Pulsar Timing Array (InPTA) campaign. We have used the observations with the 300-500 MHz band of the uGMRT for this purpose. We obtain high precision in DM measurements with precisions of the order 10^{-6}cm^{-3}pc. The ToAs obtained have sub-μs precision and the root-mean-square of the post-fit ToA residuals are in the sub-μs range. We find that the uncertainties in the DMs and ToAs obtained with this wideband technique, applied to low-frequency data, are consistent with the results obtained with traditional pulsar timing techniques and comparable to high-frequency results from other PTAs. This work opens up an interesting possibility of using low-frequency wideband observations for precision pulsar timing and gravitational wave detection with similar precision as high-frequency observations used conventionally.
△ Less
Submitted 23 February, 2022; v1 submitted 13 December, 2021;
originally announced December 2021.
-
Evidence for profile changes in PSR J1713+0747 using the uGMRT
Authors:
Jaikhomba Singha,
Mayuresh P Surnis,
Bhal Chandra Joshi,
Pratik Tarafdar,
Prerna Rana,
Abhimanyu Susobhanan,
Raghav Girgaonkar,
Neel Kolhe,
Nikita Agarwal,
Shantanu Desai,
T Prabu,
Adarsh Bathula,
Subhajit Dandapat,
Lankeswar Dey,
Shinnosuke Hisano,
Ryo Kato,
Divyansh Kharbanda,
Tomonosuke Kikunaga,
Piyush Marmat,
Sai Chaitanya Susarla,
Manjari Bagchi,
Neelam Dhanda Batra,
Arpita Choudhury,
A Gopakumar,
Yashwant Gupta
, et al. (7 additional authors not shown)
Abstract:
PSR J1713+0747 is one of the most precisely timed pulsars in the international pulsar timing array experiment. This pulsar showed an abrupt profile shape change between April 16, 2021 (MJD 59320) and April 17, 2021 (MJD 59321). In this paper, we report the results from multi-frequency observations of this pulsar carried out with the upgraded Giant Metrewave Radio Telescope (uGMRT) before and after…
▽ More
PSR J1713+0747 is one of the most precisely timed pulsars in the international pulsar timing array experiment. This pulsar showed an abrupt profile shape change between April 16, 2021 (MJD 59320) and April 17, 2021 (MJD 59321). In this paper, we report the results from multi-frequency observations of this pulsar carried out with the upgraded Giant Metrewave Radio Telescope (uGMRT) before and after the event. We demonstrate the profile change seen in Band 5 (1260 MHz - 1460 MHz) and Band 3 (300 MHz - 500 MHz). The timing analysis of this pulsar shows a disturbance accompanying this profile change followed by a recovery with a timescale of $\sim 159$ days. Our data suggest that a model with chromatic index as a free parameter is preferred over models with combinations of achromaticity with DM bump or scattering bump. We determine the frequency dependence to be $\simν^{+1.34}$.
△ Less
Submitted 16 August, 2021; v1 submitted 9 July, 2021;
originally announced July 2021.