-
3D Conductive Polymer Printed Metasurface Antenna for Fresnel Focusing
Authors:
Okan Yurduseven,
Shengrong Ye,
Thomas Fromenteze,
Daniel L. Marks,
Benjamin J. Wiley,
David R. Smith
Abstract:
We demonstrate a 3D printed holographic metasurface antenna for beam-focusing applications at 10 GHz within the X-band frequency regime. The metasurface antenna is printed using a dual-material 3D printer leveraging a biodegradable conductive polymer material (Electrifi) to print the conductive parts and polylactic acid (PLA) to print the dielectric substrate. The entire metasurface antenna is 3D…
▽ More
We demonstrate a 3D printed holographic metasurface antenna for beam-focusing applications at 10 GHz within the X-band frequency regime. The metasurface antenna is printed using a dual-material 3D printer leveraging a biodegradable conductive polymer material (Electrifi) to print the conductive parts and polylactic acid (PLA) to print the dielectric substrate. The entire metasurface antenna is 3D printed at once; no additional techniques, such as metal-plating and laser etching, are required. It is demonstrated that using the 3D printed conductive polymer metasurface antenna, high-fidelity beam focusing can be achieved within the Fresnel region of the antenna. It is also shown that the material conductivity for 3D printing has a substantial effect on the radiation characteristics of the metasurface antenna.
△ Less
Submitted 1 June, 2018;
originally announced June 2018.
-
Computational polarimetric microwave imaging
Authors:
Thomas Fromenteze,
Okan Yurduseven,
Michael Boyarsky,
Jonah Gollub,
Daniel L. Marks,
David R. Smith
Abstract:
We propose a polarimetric microwave imaging technique that exploits recent advances in computational imaging. We utilize a frequency-diverse cavity-backed metasurface, allowing us to demonstrate high-resolution polarimetric imaging using a single transceiver and frequency sweep over the operational microwave bandwidth. The frequency-diverse metasurface imager greatly simplifies the system architec…
▽ More
We propose a polarimetric microwave imaging technique that exploits recent advances in computational imaging. We utilize a frequency-diverse cavity-backed metasurface, allowing us to demonstrate high-resolution polarimetric imaging using a single transceiver and frequency sweep over the operational microwave bandwidth. The frequency-diverse metasurface imager greatly simplifies the system architecture compared with active arrays and other conventional microwave imaging approaches. We further develop the theoretical framework for computational polarimetric imaging and validate the approach experimentally using a multi-modal leaky cavity. The scalar approximation for the interaction between the radiated waves and the target---often applied in microwave computational imaging schemes---is thus extended to retrieve the susceptibility tensors, and hence providing additional information about the targets. Computational polarimetry has relevance for existing systems in the field that extract polarimetric imagery, and particular for ground observation. A growing number of short-range microwave imaging applications can also notably benefit from computational polarimetry, particularly for imaging objects that are difficult to reconstruct when assuming scalar estimations.
△ Less
Submitted 4 October, 2017; v1 submitted 16 August, 2017;
originally announced August 2017.
-
Compressive and Adaptive Millimeter-wave SAR
Authors:
Alex Mrozack,
Martin Heimbeck,
Daniel L. Marks,
Jonathan Richard,
Henry O. Everitt,
David J. Brady
Abstract:
We apply adaptive sensing techniques to the problem of locating sparse metallic scatterers using high-resolution, frequency modulated continuous wave W-band RADAR. Using a single detector, a frequency stepped source, and a lateral translation stage, inverse synthetic aperture RADAR reconstruction techniques are used to search for one or two wire scatterers within a specified range, while an adapti…
▽ More
We apply adaptive sensing techniques to the problem of locating sparse metallic scatterers using high-resolution, frequency modulated continuous wave W-band RADAR. Using a single detector, a frequency stepped source, and a lateral translation stage, inverse synthetic aperture RADAR reconstruction techniques are used to search for one or two wire scatterers within a specified range, while an adaptive algorithm determined successive sampling locations. The two-dimensional location of each scatterer is thereby identified with sub-wavelength accuracy in as few as 1/4 the number of lateral steps required for a simple raster scan. The implications of applying this approach to more complex scattering geometries are explored in light of the various assumptions made.
△ Less
Submitted 6 February, 2014;
originally announced February 2014.
-
Integrated structural and functional optical imaging combining spectral-domain optical coherence and multiphoton microscopy
Authors:
C. Vinegoni,
T. Ralston,
W. Tan,
W. Luo,
D. L. Marks,
S. A. Boppart
Abstract:
An integrated microscope that combines different optical techniques for simultaneous imaging is demonstrated. The microscope enables spectral-domain optical coherence microscopy based on optical backscatter, and multi-photon microscopy for the detection of two-photon fluorescence and second harmonic generation signals. The unique configuration of this integrated microscope allows for the simulta…
▽ More
An integrated microscope that combines different optical techniques for simultaneous imaging is demonstrated. The microscope enables spectral-domain optical coherence microscopy based on optical backscatter, and multi-photon microscopy for the detection of two-photon fluorescence and second harmonic generation signals. The unique configuration of this integrated microscope allows for the simultaneous acquisition of both anatomical (structural) and functional imaging information with particular emphasis for applications in the fields of tissue engineering and cell biology. In addition, the contemporary analysis of the spectroscopic features can enhance contrast by differentiating among different tissue components.
△ Less
Submitted 17 December, 2005;
originally announced December 2005.
-
Interferometric differentiation between resonant Coherent Anti-Stokes Raman Scattering and nonresonant four-wave-mixing processes
Authors:
Daniel L. Marks,
Claudio Vinegoni,
Jeremy S. Bredfeldt,
Stephen A. Boppart
Abstract:
A major impediment of using Coherent Anti-Stokes Raman Scattering to identify biological molecules is that the illumination levels required to produce a measurable signal often also produce significant nonresonant background from the medium, especially from water, that is not specific to the resonance being investigated. We present a method of using nonlinear interferometry to measure the tempor…
▽ More
A major impediment of using Coherent Anti-Stokes Raman Scattering to identify biological molecules is that the illumination levels required to produce a measurable signal often also produce significant nonresonant background from the medium, especially from water, that is not specific to the resonance being investigated. We present a method of using nonlinear interferometry to measure the temporal shape of the anti-Stokes signal to differentiate which components are resonant and nonresonant. This method is easily adaptable to most existing pulsed CARS illumination methods and should allow for distinguishing resonant CARS when using higher energy pulses. By examining the differences between signals produced by acetone and water, we show that the resonant and nonresonant signals can be clearly differentiated.
△ Less
Submitted 29 February, 2004;
originally announced March 2004.
-
Nonlinear optical contrast enhancement for optical coherence tomography
Authors:
C. Vinegoni,
J. S. Bredfeldt,
D. L. Marks,
S. A. Boppart
Abstract:
We present a new interferometric technique for measuring Coherent Anti-Stokes Raman Scattering (CARS) and Second Harmonic Generation (SHG) signals. Heterodyne detection is employed to increase the sensitivity in both CARS and SHG signal detection, which can also be extended to different coherent processes. The exploitation of the mentioned optical nonlinearities for molecular contrast enhancemen…
▽ More
We present a new interferometric technique for measuring Coherent Anti-Stokes Raman Scattering (CARS) and Second Harmonic Generation (SHG) signals. Heterodyne detection is employed to increase the sensitivity in both CARS and SHG signal detection, which can also be extended to different coherent processes. The exploitation of the mentioned optical nonlinearities for molecular contrast enhancement in Optical Coherence Tomography (OCT) is presented. Numerical simulations for both coherent nonlinear processes are performed in order to determine the properties of the signal expected at the exit of the described nonlinear interferometer.
△ Less
Submitted 18 December, 2003;
originally announced December 2003.
-
Nonlinear interferometric vibrational imaging
Authors:
D. L. Marks,
S. A. Boppart
Abstract:
Coherent Anti-Stokes Raman Scattering (CARS) processes are ``coherent,'' but the phase of the anti-Stokes radiation is usually lost by most incoherent spectroscopic CARS measurements. We propose a novel Raman microscopy imaging method called Nonlinear Interferometric Vibrational Imaging, which measures Raman spectra by obtaining the temporal anti-Stokes signal through nonlinear interferometry. W…
▽ More
Coherent Anti-Stokes Raman Scattering (CARS) processes are ``coherent,'' but the phase of the anti-Stokes radiation is usually lost by most incoherent spectroscopic CARS measurements. We propose a novel Raman microscopy imaging method called Nonlinear Interferometric Vibrational Imaging, which measures Raman spectra by obtaining the temporal anti-Stokes signal through nonlinear interferometry. With a more complete knowledge of the anti-Stokes signal, we show through simulations that a high-resolution Raman spectrum can be obtained of a molecule in a single pulse using broadband radiation. This could be useful for identifying the three-dimensional spatial distribution of molecular species in tissue.
△ Less
Submitted 17 November, 2003; v1 submitted 14 November, 2003;
originally announced November 2003.
-
Coherent Anti-Stokes Raman Scattering Heterodyne Interferometry
Authors:
J. S. Bredfeldt,
D. L. Marks,
C. Vinegoni,
S. Hambir,
S. A. Boppart
Abstract:
A new interferometric technique is demonstrated for measuring Coherent Anti-Stokes Raman Scattering (CARS) signals. Two forward-directed CARS signals are generated, one in each arm of an interferometer. The deterministic nature of the CARS process allows for these two signals, when spatially and temporally overlapped, to interfere with one another. Heterodyne detection can therefore be employed…
▽ More
A new interferometric technique is demonstrated for measuring Coherent Anti-Stokes Raman Scattering (CARS) signals. Two forward-directed CARS signals are generated, one in each arm of an interferometer. The deterministic nature of the CARS process allows for these two signals, when spatially and temporally overlapped, to interfere with one another. Heterodyne detection can therefore be employed to increase the sensitivity in CARS signal detection. In addition, nonlinear CARS interferometry will facilitate the use of this spectroscopic technique for molecular contrast in Optical Coherence Tomography (OCT).
△ Less
Submitted 17 November, 2003; v1 submitted 13 November, 2003;
originally announced November 2003.