Skip to main content

Showing 1–8 of 8 results for author: Marks, D L

.
  1. arXiv:1806.00394  [pdf

    physics.app-ph

    3D Conductive Polymer Printed Metasurface Antenna for Fresnel Focusing

    Authors: Okan Yurduseven, Shengrong Ye, Thomas Fromenteze, Daniel L. Marks, Benjamin J. Wiley, David R. Smith

    Abstract: We demonstrate a 3D printed holographic metasurface antenna for beam-focusing applications at 10 GHz within the X-band frequency regime. The metasurface antenna is printed using a dual-material 3D printer leveraging a biodegradable conductive polymer material (Electrifi) to print the conductive parts and polylactic acid (PLA) to print the dielectric substrate. The entire metasurface antenna is 3D… ▽ More

    Submitted 1 June, 2018; originally announced June 2018.

  2. arXiv:1708.09709  [pdf, other

    physics.app-ph

    Computational polarimetric microwave imaging

    Authors: Thomas Fromenteze, Okan Yurduseven, Michael Boyarsky, Jonah Gollub, Daniel L. Marks, David R. Smith

    Abstract: We propose a polarimetric microwave imaging technique that exploits recent advances in computational imaging. We utilize a frequency-diverse cavity-backed metasurface, allowing us to demonstrate high-resolution polarimetric imaging using a single transceiver and frequency sweep over the operational microwave bandwidth. The frequency-diverse metasurface imager greatly simplifies the system architec… ▽ More

    Submitted 4 October, 2017; v1 submitted 16 August, 2017; originally announced August 2017.

    Comments: 17 pages, 15 figures

  3. arXiv:1402.1466  [pdf, other

    physics.optics

    Compressive and Adaptive Millimeter-wave SAR

    Authors: Alex Mrozack, Martin Heimbeck, Daniel L. Marks, Jonathan Richard, Henry O. Everitt, David J. Brady

    Abstract: We apply adaptive sensing techniques to the problem of locating sparse metallic scatterers using high-resolution, frequency modulated continuous wave W-band RADAR. Using a single detector, a frequency stepped source, and a lateral translation stage, inverse synthetic aperture RADAR reconstruction techniques are used to search for one or two wire scatterers within a specified range, while an adapti… ▽ More

    Submitted 6 February, 2014; originally announced February 2014.

  4. arXiv:physics/0512161  [pdf

    physics.optics physics.med-ph

    Integrated structural and functional optical imaging combining spectral-domain optical coherence and multiphoton microscopy

    Authors: C. Vinegoni, T. Ralston, W. Tan, W. Luo, D. L. Marks, S. A. Boppart

    Abstract: An integrated microscope that combines different optical techniques for simultaneous imaging is demonstrated. The microscope enables spectral-domain optical coherence microscopy based on optical backscatter, and multi-photon microscopy for the detection of two-photon fluorescence and second harmonic generation signals. The unique configuration of this integrated microscope allows for the simulta… ▽ More

    Submitted 17 December, 2005; originally announced December 2005.

    Comments: 16 pages, 4 figures

  5. arXiv:physics/0403007  [pdf, ps, other

    physics.optics physics.gen-ph

    Interferometric differentiation between resonant Coherent Anti-Stokes Raman Scattering and nonresonant four-wave-mixing processes

    Authors: Daniel L. Marks, Claudio Vinegoni, Jeremy S. Bredfeldt, Stephen A. Boppart

    Abstract: A major impediment of using Coherent Anti-Stokes Raman Scattering to identify biological molecules is that the illumination levels required to produce a measurable signal often also produce significant nonresonant background from the medium, especially from water, that is not specific to the resonance being investigated. We present a method of using nonlinear interferometry to measure the tempor… ▽ More

    Submitted 29 February, 2004; originally announced March 2004.

    Comments: 8 pages, 4 figures

  6. arXiv:physics/0312114  [pdf, ps, other

    physics.optics physics.med-ph

    Nonlinear optical contrast enhancement for optical coherence tomography

    Authors: C. Vinegoni, J. S. Bredfeldt, D. L. Marks, S. A. Boppart

    Abstract: We present a new interferometric technique for measuring Coherent Anti-Stokes Raman Scattering (CARS) and Second Harmonic Generation (SHG) signals. Heterodyne detection is employed to increase the sensitivity in both CARS and SHG signal detection, which can also be extended to different coherent processes. The exploitation of the mentioned optical nonlinearities for molecular contrast enhancemen… ▽ More

    Submitted 18 December, 2003; originally announced December 2003.

    Comments: 13 pages, Latex, 10 Postscript figures, uses opex3 style, submitted

  7. Nonlinear interferometric vibrational imaging

    Authors: D. L. Marks, S. A. Boppart

    Abstract: Coherent Anti-Stokes Raman Scattering (CARS) processes are ``coherent,'' but the phase of the anti-Stokes radiation is usually lost by most incoherent spectroscopic CARS measurements. We propose a novel Raman microscopy imaging method called Nonlinear Interferometric Vibrational Imaging, which measures Raman spectra by obtaining the temporal anti-Stokes signal through nonlinear interferometry. W… ▽ More

    Submitted 17 November, 2003; v1 submitted 14 November, 2003; originally announced November 2003.

    Comments: 5 pages, Latex, 3 Postscript figures, uses revtex4 and epsfig, submitted Version 2: rescaled the figures to fit columns

  8. arXiv:physics/0311057  [pdf, ps, other

    physics.optics physics.med-ph quant-ph

    Coherent Anti-Stokes Raman Scattering Heterodyne Interferometry

    Authors: J. S. Bredfeldt, D. L. Marks, C. Vinegoni, S. Hambir, S. A. Boppart

    Abstract: A new interferometric technique is demonstrated for measuring Coherent Anti-Stokes Raman Scattering (CARS) signals. Two forward-directed CARS signals are generated, one in each arm of an interferometer. The deterministic nature of the CARS process allows for these two signals, when spatially and temporally overlapped, to interfere with one another. Heterodyne detection can therefore be employed… ▽ More

    Submitted 17 November, 2003; v1 submitted 13 November, 2003; originally announced November 2003.

    Comments: 4 pages, Latex, 3 Postscript figures, uses revtex4 and epsfig, submitted version 2: changed reference 12