-
A high sensitivity Cherenkov detector for Prompt Gamma Timing and Time Imaging
Authors:
Maxime Jacquet,
Saba Ansari,
Marie-Laure Gallin-Martel,
Adélie André,
Yannick Boursier,
Mathieu Dupont,
Jilali Es-smimih,
Laurent Gallin-Martel,
Joël Hérault,
Christophe Hoarau,
Johan-Petter Hofverberg,
Daniel Maneval,
Christian Morel,
Jean-François Muraz,
Fabrice Salicis,
Sara Marcatili
Abstract:
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown…
▽ More
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown, through Monte Carlo simulation, that an original data reconstruction algorithm (Prompt Gamma Time Imaging) allows to combine the response of multiple detectors placed around the target. In this work we focus on the experimental feasibility of PGTI in Single Proton Regime (SPR) through the development of a multi-channel, Cherenkov-based PG detector with a targeted time resolution of 235 ps (FWHM): the TOF Imaging ARrAy (TIARA). The PG module that we developed is composed of a small PbF$_{2}$ crystal coupled to a silicon photoMultiplier to provide the time stamp of the PG. This prototype was tested with 63 MeV protons delivered from a cyclotron: a time resolution of 276 ps (FWHM) was obtained, resulting in a proton range sensitivity of 4 mm at 2$σ$ with the acquisition of only 600 PGs. A second prototype was also evaluated with 148 MeV protons delivered from a synchro-cyclotron obtaining a time resolution below 167 ps (FWHM) for the gamma detector. Moreover, using two identical PG modules, it was shown that a uniform sensitivity on the PG profiles would be achievable by combining the response of gamma detectors uniformly distributed around the target. This work provides the experimental proof-of-concept for the development of a high sensitivity detector that can be used to monitor particle therapy treatments and potentially act in real-time if the irradiation does not comply to treatment plan.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring
Authors:
Sébastien Curtoni,
Marie-Laure Gallin-Martel,
Sara Marcatili,
Latifa Abbassi,
Alexandre Bes,
Germain Bosson,
Johann Collot,
Thierry Crozes,
Denis Dauvergne,
Wout De Nolf,
Pierre Everaere,
Laurent Gallin-Martel,
Abderrahmane Ghimouz,
Ferid Haddad,
Christophe Hoarau,
Jean-Yves Hostachy,
Charbel Koumeir,
Ana Lacoste,
Vincent Métivier,
John Morse,
Jean-François Motte,
Jean-François Muraz,
Freddy Poirier,
Fatah Ellah Rarbi,
Olivier Rossetto
, et al. (4 additional authors not shown)
Abstract:
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improv…
▽ More
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improved by detecting single ions with a 100 ps ($σ$) time resolution, through a quality assurance procedure at low beam intensity at the beginning of the treatment session. This work presents the investigations led to assess the performance of Chemical Vapor Deposition (CVD) diamond detectors to fulfill these requirements. A $^{90}$Sr beta source, 68 MeV protons, 95 MeV/u carbon ions and a synchrotron X-ray pulsed beam were used to measure the time resolution, single ion detection efficiency and proton counting capability of various CVD diamond samples. An offline technique, based on double-sided readout with fast current preamplifiers and used to improve the signal-to-noise ratio, is also presented. The different tests highlighted Time-Of-Flight resolutions ranging from 13 ps ($σ$) to 250 ps ($σ$), depending on the experimental conditions. The single 68 MeV proton detection efficiency of various large area polycrystalline (pCVD) samples was measured to be $>$96% using coincidence measurements with a single-crystal reference detector. Single-crystal CVD (sCVD) diamond proved to be able to count a discrete number of simultaneous protons while it was not achievable with a polycrystalline sample. Considering the results of the present study, two diamond hodoscope demonstrators are under development: one based on sCVD, and one of larger size based on pCVD. They will be used for the purpose of single ion as well as ion bunches detection, either at reduced or clinical beam intensities.
△ Less
Submitted 23 August, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
RF pulse amplifier for CVD-diamond particle detectors
Authors:
C. Hoarau,
G. Bosson,
J. -L. Bouly,
S. Curtoni,
D. Dauvergne,
P. Everaere,
M. -L. Gallin-Martel,
S. Marcatili,
J. -F. Muraz,
A. Portier,
N. Rosuel
Abstract:
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stam**, with prerequisite of fast electro…
▽ More
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stam**, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier offers the possibility of high voltage biasing, a characteristic essential for driving diamond detectors. Finally the greatest asset of this study is certainly the minimization of the power consumption, which allows us to consider designs with multiple amplifiers, in limited space, for striped diamond detectors.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
A Time-Of-Flight-Based Reconstruction for Real-Time Prompt-Gamma Imaging in Protontherapy
Authors:
Maxime Jacquet,
Sara Marcatili,
Marie-Laure Gallin-Martel,
Jean-Luc Bouly,
Yannick Boursier,
Denis Dauvergne,
Mathieu Dupont,
Laurent Gallin-Martel,
Joël Hérault,
Jean-Michel Létang,
Daniel Manéval,
Christian Morel,
Jean-François Muraz,
Étienne Testa
Abstract:
We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam…
▽ More
We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam delivery. In this paper, two non-iterative reconstruction strategies are proposed. The first is based on the resolution of an analytical formula describing the PG vertex distribution in 3D. Here, it was resolved under a one-dimensional approximation in order to measure a potential proton range shift along the beam direction. The second is based on the calculation of the Centre-Of-Gravity (COG) of the TIARA pixel detectors counts and also provides 3D information on a possible beam displacement. The PG vertex reconstruction was evaluated in two different scenarios. A coincidence time resolution of 100 ps (rms) can be attained in single proton regime (operating a reduction of the beam current) and using an external beam monitor to provide a start trigger for the TOF measurement. Under these conditions, MC simulations have shown that a millimetric proton range shift sensitivity can be achieved at 2$σ$ with 10$^{8}$ incident protons. This level of accuracy would allow to act in real-time if the treatment does not conform to treatment plan. A worst case scenario of a 1 ns (rms) TOF resolution was also considered to demonstrate that a degraded timing information can be compensated by increasing the acquisition statistics: in this case, a 2 mm range shift would be detectable at 2$σ$ with 10$^{9}$ incident protons. The COG method has shown excellent capabilities of detecting lateral beam displacements: a 2 mm sensitivity was found at 2$σ$ with 10$^{8}$ incident protons.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
A 100 ps TOF Detection System for On-Line Range- Monitoring in Hadrontherapy
Authors:
Sara Marcatili,
Sébastien Curtoni,
Denis Dauvergne,
Ferid Haddad,
Maxime Jacquet,
Charbel Koumeir,
Jean Michel Létang,
Jayde Livingstone,
Vincent Métivier,
Laurent Gallin-Martel,
Marie-Laure Gallin-Martel,
Jean-François Muraz,
Noel Servagent,
Étienne Testa
Abstract:
The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based on TOF-resolved (time-of-flight) Prompt Gamma (PG) imaging with 100 ps time resolution. Our aim is to detect a possible deviation of the proton range with respec…
▽ More
The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based on TOF-resolved (time-of-flight) Prompt Gamma (PG) imaging with 100 ps time resolution. Our aim is to detect a possible deviation of the proton range with respect to treatment planning within the first few irradiation spots at the beginning of the session. The system consists of a diamond-based beam hodoscope for single proton tagging, operated in time coincidence with one or more gamma detectors placed downstream of the patient. The TOF between the proton time of arrival in the hodoscope and the PG detection time provides an indirect measurement of the proton range in the patient with a precision strictly related to the system time resolution. With a single ~38 cm$^{3}$ BaF2 detector placed at 15 cm from a heterogeneous PMMA target, we obtained a coincidence time resolution of 101 ps (rms). This system allowed us to measure the thickness and position of an air cavity within a PMMA target, and the associated proton range shift: a 3 mm shift can be detected at 2$σ$ confidence level within a single large irradiation spot (~10$^{8}$ protons). We are currently conceiving a multi-channel PG timing detector with 3D target coverage. Each pixel will provide the PG detection time and its hit position, that can be used to reconstruct the 3D distribution of PG vertices in the patient. Our approach does not require collimation and allows to dramatically increase the detection efficiency. Since both signal detection and background rejection are based on TOF, the constraints on energy resolution can be relaxed to further improve time resolution.
△ Less
Submitted 20 January, 2020; v1 submitted 13 January, 2020;
originally announced January 2020.
-
Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy
Authors:
S. Marcatili,
J. Collot,
S. Curtoni,
D. Dauvergne,
J-Y. Hostachy,
C. Koumeir,
J. M. Létang,
J. Livingstone,
V. Métivier,
L. Gallin-Martel,
M-L. Gallin-Martel,
J. F. Muraz,
N. Servagent,
É. Testa,
M. Yamouni
Abstract:
In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in…
▽ More
In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in order to build TOF spectra of PG generated in a heterogeneous target presenting an air cavity of variable thickness. Since the measurement was carried out at low beam currents ($<$ 1 proton/bunch) it was possible to reach excellent coincidence time resolutions, of the order of 100 ps ($σ$). Our goal is to detect possible deviations of the proton range with respect to treatment planning within a few intense irradiation spots at the beginning of the session and then carry on the treatment at standard beam currents. The measurements were limited to 10 mm proton range shift. A Monte Carlo simulation study reproducing the experiment has shown that a 3 mm shift can be detected at 2$σ$ by a single detector of $\sim 1.4 \times 10^{-3}$ absolute detection efficiency within a single irradiation spot ($\sim$10$^{8}$ protons) and an optimised experimental set-up.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.