-
Design and Beam Test Results for the 2D Projective sPHENIX Electromagnetic Calorimeter Prototype
Authors:
C. A. Aidala,
S. Altaf,
R. Belmont,
S. Boose,
D. Cacace,
M. Connors,
E. Desmond,
J. Frantz,
E. A. Gamez,
N. Grau,
J. S. Haggerty,
A. Hodges,
J. Huang,
Y. Kim,
M. D. Lenz,
W. Lenz,
N. A. Lewis,
E. J. Mannel,
J. D. Osborn,
D. V. Perepelitsa,
M. Phipps,
R. Pisani,
S. Polizzo,
A. Pun,
M. L. Purschke
, et al. (13 additional authors not shown)
Abstract:
sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of QCD matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds…
▽ More
sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of QCD matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds to a solid angle of $ Δη\times Δφ= 0.2 \times 0.2$ centered at pseudo-rapidity $η= 1$. The prototype consists of scintillating fibers embedded in a mix of tungsten powder and epoxy. The fibers project back approximately to the center of the sPHENIX detector, giving 2D projectivity. The energy response of the EMCal prototype was studied as a function of position and input energy. The energy resolution of the EMCal prototype was obtained after applying a position dependent energy correction and a beam profile correction. Two separate position dependent corrections were considered. The EMCal energy resolution was found to be $σ(E)/\langle E\rangle = 3.5(0.1) \oplus 13.3(0.2)/\sqrt{E}$ based on the hodoscope position dependent correction, and $σ(E)/\langle E\rangle = 3.0(0.1) \oplus 15.4(0.3)/\sqrt{E}$ based on the cluster position dependent correction. These energy resolution results meet the requirements of the sPHENIX physics program.
△ Less
Submitted 15 March, 2021; v1 submitted 27 March, 2020;
originally announced March 2020.
-
A Comparison of the Effects of Neutron and Gamma Radiation in Silicon Photomultipliers
Authors:
B. Biró,
G. David,
A. Fenyvesi,
J. S. Haggerty,
J. Kierstead,
E. J. Mannel,
T. Majoros,
J. Molnar,
F. Nagy,
S. Stoll,
B. Ujvari,
C. L. Woody
Abstract:
The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of MPPCs from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at Brookhaven National Lab and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ra…
▽ More
The effects of radiation damage in silicon photomultipliers (SiPMs) from gamma rays have been measured and compared with the damage produced by neutrons. Several types of MPPCs from Hamamatsu were exposed to gamma rays and neutrons at the Solid State Gamma Ray Irradiation Facility (SSGRIF) at Brookhaven National Lab and the Institute for Nuclear Research (Atomki) in Debrecen, Hungary. The gamma ray exposures ranged from 1 krad to 1 Mrad and the neutron exposures ranged from 10$^8$ n/cm$^2$ to 10$^{12}$ n/cm$^2$. The main effect of gamma ray damage is an increase in the noise and leakage current in the irradiated devices, similar to what is seen from neutron damage, but the level of damage is considerably less at comparable high levels of exposure. In addition, the damage from gamma rays saturates after a few hundred krad, while the damage from neutrons shows no sign of saturation, suggestive of different damage mechanisms in the two cases. The change in optical absorption in the window material of the SiPMs due to radiation was also measured. This study was carried out in order to evaluate the use of SiPMs for particle physics applications with moderate levels of radiation exposures.
△ Less
Submitted 7 April, 2019; v1 submitted 12 September, 2018;
originally announced September 2018.
-
Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes
Authors:
C. A. Aidala,
V. Bailey,
S. Beckman,
R. Belmont,
C. Biggs,
J. Blackburn,
S. Boose,
M. Chiu,
M. Connors,
E. Desmond,
A. Franz,
J. S. Haggerty,
X. He,
M. M. Higdon,
J. Huang,
K. Kauder,
E. Kistenev,
J. LaBounty,
J. G. Lajoie,
M. Lenz,
W. Lenz,
S. Li,
V. R. Loggins,
E. J. Mannel,
T. Majoros
, et al. (25 additional authors not shown)
Abstract:
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the…
▽ More
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\%\oplus~15.5\%/\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\%\oplus 64.9\%/\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.
△ Less
Submitted 16 December, 2018; v1 submitted 5 April, 2017;
originally announced April 2017.
-
Status and overview of development of the Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
Authors:
Ryo Ichimiya,
Nicole Apadula,
Yasuyuki Akiba,
Ermias Atomssa,
Simon Chollet,
Olivier Drapier,
Hideto En'yo,
Kohei Fujiwara,
Franck Gastaldi,
Raphael Granier de Cassagnac,
Miki Kasai,
Kazuyosi Kurita,
Maki Kurosawa,
Eric J. Mannel,
Hiroaki Ohnishi,
Yoshiyuki Onuki,
Robert Pak,
Charles Pancake,
Michiko Sekimoto,
Eugene Shafto,
Walter Sondheim,
Atsushi Taketani
Abstract:
We have developed a silicon pixel detector to enhance the physics capabilities of the PHENIX experiment. This detector, consisting of two layers of sensors, will be installed around the beam pipe at the collision point and covers a pseudo-rapidity of | η| < 1.2 and an azimuth angle of | φ| ~ 2π. The detector uses 200 um thick silicon sensors and readout chips developed for the ALICE experiment.…
▽ More
We have developed a silicon pixel detector to enhance the physics capabilities of the PHENIX experiment. This detector, consisting of two layers of sensors, will be installed around the beam pipe at the collision point and covers a pseudo-rapidity of | η| < 1.2 and an azimuth angle of | φ| ~ 2π. The detector uses 200 um thick silicon sensors and readout chips developed for the ALICE experiment. In order to meet the PHENIX DAQ readout requirements, it is necessary to read out 4 readout chips in parallel. The physics goals of PHENIX require that radiation thickness of the detector be minimized. To meet these criteria, the detector has been designed and developed. In this paper, we report the current status of the development, especially the development of the low-mass readout bus and the front-end readout electronics.
△ Less
Submitted 1 May, 2009; v1 submitted 15 December, 2008;
originally announced December 2008.
-
Search for Correlations between HiRes Stereo Events and Active Galactic Nuclei
Authors:
R. U. Abbasi,
T. Abu-Zayyad,
M. Allen,
J. F. Amman,
G. Archbold,
K. Belov,
J. W. Belz,
S. Y. BenZvi,
D. R. Bergman,
S. A. Blake,
J. H. Boyer,
O. A. Brusova,
G. W. Burt,
C. Cannon,
Z. Cao,
W. Deng,
Y. Fedorova,
J. Findlay,
C. B. Finley,
R. C. Gray,
W. F. Hanlon,
C. M. Hoffman,
M. H. Holzscheiter,
G. Hughes,
P. Huntemeyer
, et al. (39 additional authors not shown)
Abstract:
We have searched for correlations between the pointing directions of ultrahigh energy cosmic rays observed by the High Resolution Fly's Eye experiment and Active Galactic Nuclei (AGN) visible from its northern hemisphere location. No correlations, other than random correlations, have been found. We report our results using search parameters prescribed by the Pierre Auger collaboration. Using the…
▽ More
We have searched for correlations between the pointing directions of ultrahigh energy cosmic rays observed by the High Resolution Fly's Eye experiment and Active Galactic Nuclei (AGN) visible from its northern hemisphere location. No correlations, other than random correlations, have been found. We report our results using search parameters prescribed by the Pierre Auger collaboration. Using these parameters, the Auger collaboration concludes that a positive correlation exists for sources visible to their southern hemisphere location. We also describe results using two methods for determining the chance probability of correlations: one in which a hypothesis is formed from scanning one half of the data and tested on the second half, and another which involves a scan over the entire data set. The most significant correlation found occurred with a chance probability of 24%.
△ Less
Submitted 15 August, 2008; v1 submitted 2 April, 2008;
originally announced April 2008.
-
An upper limit on the electron-neutrino flux from the HiRes detector
Authors:
R. U. Abbasi,
T. Abu-Zayyad,
M. Allen,
J. F. Amann,
G. Archbold,
K. Belov,
J. W. Belz,
S. Y. Ben Zvi,
D. R. Bergman,
A. Biesiadecka,
S. A. Blake,
J. H. Boyer,
O. A. Brusova,
G. W. Burt,
C. Cannon,
Z. Cao,
W. Deng,
Y. Fedorova,
J. Findlay,
C. B. Finley,
R. C. Gray,
W. F. Hanlon,
C. M. Hoffman,
M. H. Holzscheiter,
G. Hughes
, et al. (42 additional authors not shown)
Abstract:
Air-fluorescence detectors such as the High Resolution Fly's Eye (HiRes) detector are very sensitive to upward-going, Earth-skimming ultrahigh energy electron-neutrino-induced showers. This is due to the relatively large interaction cross sections of these high-energy neutrinos and to the Landau-Pomeranchuk-Migdal (LPM) effect. The LPM effect causes a significant decrease in the cross sections f…
▽ More
Air-fluorescence detectors such as the High Resolution Fly's Eye (HiRes) detector are very sensitive to upward-going, Earth-skimming ultrahigh energy electron-neutrino-induced showers. This is due to the relatively large interaction cross sections of these high-energy neutrinos and to the Landau-Pomeranchuk-Migdal (LPM) effect. The LPM effect causes a significant decrease in the cross sections for bremsstrahlung and pair production, allowing charged-current electron-neutrino-induced showers occurring deep in the Earth's crust to be detectable as they exit the Earth into the atmosphere. A search for upward-going neutrino-induced showers in the HiRes-II monocular dataset has yielded a null result. From an LPM calculation of the energy spectrum of charged particles as a function of primary energy and depth for electron-induced showers in rock, we calculate the shape of the resulting profile of these showers in air. We describe a full detector Monte Carlo simulation to determine the detector response to upward-going electron-neutrino-induced cascades and present an upper limit on the flux of electron-neutrinos.
△ Less
Submitted 3 June, 2008; v1 submitted 4 March, 2008;
originally announced March 2008.
-
Measurement of the Cosmic Ray Energy Spectrum and Composition from 10^{17} to 10^{18.3} eV Using a Hybrid Fluorescence Technique
Authors:
T. Abu-Zayyad,
K. Belov,
D. J. Bird,
J. Boyer,
Z. Cao,
M. Catanese,
G. F. Chen,
R. W. Clay,
C. E. Covault,
H. Y. Dai,
B. R. Dawson,
J. W. Elbert,
B. E. Fick,
L. F. Fortson,
J. W. Fowler,
K. G. Gibbs,
M. A. K. Glasmacher,
K. D. Green,
Y. Ho,
A. Huang,
C. C. Jui,
M. J. Kidd,
D. B. Kieda,
B. C. Knapp,
S. Ko
, et al. (22 additional authors not shown)
Abstract:
We study the spectrum and average mass composition of cosmic rays with primary energies between 10^{17} eV and 10^{18} eV using a hybrid detector consisting of the High Resolution Fly's Eye (HiRes) prototype and the MIA muon array. Measurements have been made of the change in the depth of shower maximum as a function of energy. A complete Monte Carlo simulation of the detector response and compa…
▽ More
We study the spectrum and average mass composition of cosmic rays with primary energies between 10^{17} eV and 10^{18} eV using a hybrid detector consisting of the High Resolution Fly's Eye (HiRes) prototype and the MIA muon array. Measurements have been made of the change in the depth of shower maximum as a function of energy. A complete Monte Carlo simulation of the detector response and comparisons with shower simulations leads to the conclusion that the cosmic ray intensity is changing f rom a heavier to a lighter composition in this energy range. The spectrum is consistent with earlier Fly's Eye measurements and supports the previously found steepening near 4 \times 10^{17} eV .
△ Less
Submitted 31 October, 2000;
originally announced October 2000.
-
A Multi-Component Measurement of the Cosmic Ray Composition Between 10^{17} eV and 10^{18} eV
Authors:
T. Abu-Zayyad,
K. Belov,
D. J. Bird,
J. Boyer,
Z. Cao,
M. Catanese,
G. F. Chen,
R. W. Clay,
C. E. Covault,
J. W. Cronin,
H. Y. Dai,
B. R. Dawson,
J. W. Elbert,
B. E. Fick,
L. F. Fortson,
J. W. Fowler,
K. G. Gibbs,
M. A. K. Glasmacher,
K. D. Green,
Y. Ho,
A. Huang,
C. C. Jui,
M. J. Kidd,
D. B. Kieda,
B. C. Knapp
, et al. (23 additional authors not shown)
Abstract:
The average mass composition of cosmic rays with primary energies between $10^{17}$eV and $10^{18}$eV has been studied using a hybrid detector consisting of the High Resolution Fly's Eye (HiRes) prototype and the MIA muon array. Measurements have been made of the change in the depth of shower maximum, $X_{max}$, and in the change in the muon density at a fixed core location, $ρ_μ(600m)$, as a fu…
▽ More
The average mass composition of cosmic rays with primary energies between $10^{17}$eV and $10^{18}$eV has been studied using a hybrid detector consisting of the High Resolution Fly's Eye (HiRes) prototype and the MIA muon array. Measurements have been made of the change in the depth of shower maximum, $X_{max}$, and in the change in the muon density at a fixed core location, $ρ_μ(600m)$, as a function of energy. The composition has also been evaluated in terms of the combination of $X_{max}$ and $ρ_μ(600m)$. The results show that the composition is changing from a heavy to lighter mix as the energy increases.
△ Less
Submitted 9 November, 1999;
originally announced November 1999.