Microdosimetry of a clinical carbon-ion pencil beam at MedAustron -- Part 1: experimental characterization
Authors:
Cynthia Meouchi,
Sandra Barna,
Anatoly Rosenfeld,
Linh T. Tran,
Hugo Palmans,
Giulio Magrin
Abstract:
This paper characterizes the microdosimetric spectra of a single-energy carbon-ion pencil beam at MedAustron using a miniature solid-state silicon microdosimeter to estimate the impact of the lateral distribution of the different fragments on the microdosimetric spectra. The microdosimeter was fixed at one depth and then laterally moved away from the central beam axis in steps of approximately 2 m…
▽ More
This paper characterizes the microdosimetric spectra of a single-energy carbon-ion pencil beam at MedAustron using a miniature solid-state silicon microdosimeter to estimate the impact of the lateral distribution of the different fragments on the microdosimetric spectra. The microdosimeter was fixed at one depth and then laterally moved away from the central beam axis in steps of approximately 2 mm. The measurements were taken in both horizontal and vertical direction in a water phantom at different depths. In a position on the distal dose fall-off beyond the Bragg peak, the frequency-mean and the dose-mean lineal energies were derived using either the entire range of y-values, or a sub-range of y values, presumingly corresponding mainly to contributions from primary particles. The measured microdosimetric spectra do not exhibit a significant change up to 4 mm away from the beam central axis. For lateral positions more than 4 mm away from the central axis, the relative contribution of the lower lineal-energy part of the spectrum increases with lateral distance due to the increased partial dose from secondary fragments. The average values yF and yD are almost constant for each partial contribution. However, when all particles are considered together, the average value of yF and yD varies with distance from the axis due to the changing dose fractions of these two components varying by 30 % and 10 % respectively up to the most off axis vertical position. Characteristic features in the microdosimetric spectra providing strong indications of the presence of helium and boron fragments have been observed downstream of the distal part of the Bragg peak. We were able to investigate the radiation quality as function of off-axis position. These measurements emphasize variation of the radiation quality within the beam and this has implications in terms of relative biological effectiveness.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.
-
Microdosimetry in ion-beam therapy: studying and comparing outcomes from different detectors
Authors:
Giulio Magrin
Abstract:
Experimental studies of microdosimetry in therapeutic ion beams have been performed using several detectors. The differences among them lie on the shapes, the site sizes, and the material. Coin-shaped solid-state detectors made of silicon or diamond with thickness varying from 0.3 to 10 microns, as well as proportional counters with spherical and cylindrical sensitive volumes filled with tissue-eq…
▽ More
Experimental studies of microdosimetry in therapeutic ion beams have been performed using several detectors. The differences among them lie on the shapes, the site sizes, and the material. Coin-shaped solid-state detectors made of silicon or diamond with thickness varying from 0.3 to 10 microns, as well as proportional counters with spherical and cylindrical sensitive volumes filled with tissue-equivalent gas are the microdosimeters used in therapeutic proton and carbon-ion beams. One goal of microdosimetry in the clinical environment is providing repeatable specification of the radiation quality of the radiation field. A methodology should be developed to provide, independently from the heterogeneous information collected with the different detectors, a detector-independent specification of the radiation quality. Historically the specification of the radiation quality is provided either, in terms of Linear Energy Transfer (LET) or in terms of lineal energy, y. First this study focuses on identifying the correlation between the distributions of LET and the lineal energy spectra as well as the correspondence between their mean values calculated in frequency and in dose. The evaluation is based on the method of LET analysis described by Kellerer making the adaptation to the peculiarities of the therapeutic ion-beam where the pristine irradiation is unidirectional and made of a single type of mono-energetic ions. The second objective of this study is to interpret the spectrum collected by a slab and estimate what the spectrum would be if it was collected by a detector different in shape, material, or size. An example confirms the method starting from the simulated lineal energy spectrum obtained for carbon ions in a slab detector of graphite and converting it to the spectruma that would be obtained in the same radiation field for spherical, cylindrical, and slab detector made of water.
△ Less
Submitted 16 March, 2018; v1 submitted 19 February, 2018;
originally announced February 2018.
-
Cyclinacs: Fast-Cycling Accelerators for Hadrontherapy
Authors:
U. Amaldi,
S. Braccini,
A. Citterio,
K. Crandall,
M. Crescenti,
M. Dominietto,
A. Giuliacci,
G. Magrin,
C. Mellace,
P. Pearce,
G. Pitta',
E. Rosso,
M. Weiss,
R. Zennaro
Abstract:
We propose an innovative fast-cycling accelerator complex conceived and designed to exploit at best the properties of accelerated ion beams for hadrontherapy. A cyclinac is composed by a cyclotron, which can be used also for other valuable medical and research purposes, followed by a high gradient linear accelerator capable to produce ion beams optimized for the irradiation of solid tumours with…
▽ More
We propose an innovative fast-cycling accelerator complex conceived and designed to exploit at best the properties of accelerated ion beams for hadrontherapy. A cyclinac is composed by a cyclotron, which can be used also for other valuable medical and research purposes, followed by a high gradient linear accelerator capable to produce ion beams optimized for the irradiation of solid tumours with the most modern techniques. The properties of cyclinacs together with design studies for protons and carbon ions are presented and the advantages in facing the challenges of hadrontherapy are discussed.
△ Less
Submitted 20 February, 2009;
originally announced February 2009.