-
On the Echogenicity of Natural Starch-Based Blood Mimicking Fluids for Contrast Enhanced Ultrasound Imaging: Preliminary In-vitro Experiments
Authors:
V. Arun Kumar,
A. N. Madhavanunni,
S. Nivetha,
Mahesh Raveendranatha Panicker
Abstract:
Natural starch-based blood-mimicking fluid (BMF) has been used as an alternative to commercially available BMFs for in-vitro Doppler investigations in low-resource settings. Most reported works in the literature have used corn starch-based BMF. Evaluation of other natural starches for potential BMF and their characterization have relatively been unexplored in the literature. To this end, this work…
▽ More
Natural starch-based blood-mimicking fluid (BMF) has been used as an alternative to commercially available BMFs for in-vitro Doppler investigations in low-resource settings. Most reported works in the literature have used corn starch-based BMF. Evaluation of other natural starches for potential BMF and their characterization have relatively been unexplored in the literature. To this end, this work investigates the echogenicity of corn-, potato-, tapioca-, and wheat starch-based BMFs prepared using a liquid base of pure water-glycerol mixture with three different starch concentrations (1%, 3%, and 5%). The experiments were performed by manually pum** the BMFs to a PolyVinyl alcohol (PVA) based flow phantom using a syringe and raw datasets were acquired using a Verasonics Vantage 128 Research Ultrasound System. Echogenicity was measured as the mean pixel intensity in a selected region of interest (ROI) in the beamformed image. Among the four natural starch-based BMFs, potato starch-based BMF showed the highest echogenicity and contrast with almost 13%, 14%, and 10% higher pixel intensities (dB) than that of the least echoic BMF with 1%, 3%, and 5% starch concentrations respectively. Moreover, the echogenicity of corn, tapioca, and wheat starch-based BMF was observed to be similar, and the results suggest that these BMFs with higher starch concentrations shall be employed for in-vitro contrast-enhanced ultrasound imaging.
△ Less
Submitted 10 March, 2024;
originally announced March 2024.
-
A Performance Evaluation of Filtered Delay Multiply and Sum Beamforming for Ultrasound Localization Microscopy: Preliminary Results
Authors:
A. N. Madhavanunni,
Niya Mariam Benoy,
Mahesh Raveendranatha Panicker,
Himanshu Shekhar
Abstract:
Ultrafast ultrasound localization microscopy (ULM), which has shown promising results in microvascular imaging, overcomes the typical trade-off between resolution and penetration depth. Combining ultrasound contrast agents and high frame rate imaging enables ULM to visualize microvasculature and quantify flow. However, the quality of the microvascular maps obtained depends on the signal-to-noise r…
▽ More
Ultrafast ultrasound localization microscopy (ULM), which has shown promising results in microvascular imaging, overcomes the typical trade-off between resolution and penetration depth. Combining ultrasound contrast agents and high frame rate imaging enables ULM to visualize microvasculature and quantify flow. However, the quality of the microvascular maps obtained depends on the signal-to-noise ratio of the received signals, image reconstruction techniques, and the microbubble (MB) localization and tracking algorithms used. Most reported research in ULM employs the conventional delay and sum (DAS) beamforming technique for image reconstruction despite its limited contrast and resolution. In this work, a filtered delay multiply and sum (F-DMAS) beamforming approach with non-steered plane wave transmit was employed for ULM, and its performance was compared with the conventional DAS-based approach for the different localization algorithms available in the Localization and Tracking Toolbox for Ultrasound Localization Microscopy. We also introduce two novel image quality measures that can overcome the limitations of conventional quality metrics that require suitable targets for evaluation. We also report the preliminary in-vitro investigation of F-DMAS with B-mode and power Doppler maps for microvascular imaging. The results are promising with enhanced contrast and lateral resolution, and suggest that further experimental studies are warranted.
△ Less
Submitted 27 February, 2024;
originally announced February 2024.
-
A Portable Ultrasound Imaging Pipeline Implementation with GPU Acceleration on Nvidia CLARA AGX
Authors:
A. N. Madhavanunni,
V. Arun Kumar,
Mahesh Raveendranatha Panicker
Abstract:
In this paper, we present a GPU-accelerated prototype implementation of a portable ultrasound imaging pipeline on an Nvidia CLARA AGX development kit. The raw data is acquired with nonsteered plane wave transmit using a programmable handheld open platform that supports 128-channel transmit and 64-channel receive. The received signals are transferred to the Nvidia CLARA AGX developer platform throu…
▽ More
In this paper, we present a GPU-accelerated prototype implementation of a portable ultrasound imaging pipeline on an Nvidia CLARA AGX development kit. The raw data is acquired with nonsteered plane wave transmit using a programmable handheld open platform that supports 128-channel transmit and 64-channel receive. The received signals are transferred to the Nvidia CLARA AGX developer platform through a host system for accelerated imaging. GPU-accelerated implementation of the conventional delay and sum (DAS) beamformer along with two adaptive nonlinear beamformers and two Fourier-based techniques was performed. The feasibility of the complete pipeline and its imaging performance was evaluated with in-vitro phantom imaging experiments and the efficacy is demonstrated with preliminary in-vivo scans. The image quality quantified by the standard contrast and resolution metrics was comparable with that of the CPU implementation. The execution speed of the implemented beamformers was also investigated for different sizes of imaging grids and a significant speedup as high as 180 times that of the CPU implementation was observed. Since the proposed pipeline involves Nvidia CLARA AGX, there is always the potential for easy incorporation of online/active learning approaches.
△ Less
Submitted 31 October, 2023;
originally announced November 2023.
-
Towards Non-contact 3D Ultrasound for Wrist Imaging
Authors:
Antony Jerald,
A. N. Madhavanunni,
Gayathri Malamal,
Mahesh Raveendranatha Panicker
Abstract:
Objective: The objective of this work is an attempt towards non-contact freehand 3D ultrasound imaging with minimal complexity added to the existing point of care ultrasound (POCUS) systems. Methods: This study proposes a novel approach of using a mechanical track for non-contact ultrasound (US) scanning. The approach thus restricts the probe motion to a linear plane, to simplify the acquisition a…
▽ More
Objective: The objective of this work is an attempt towards non-contact freehand 3D ultrasound imaging with minimal complexity added to the existing point of care ultrasound (POCUS) systems. Methods: This study proposes a novel approach of using a mechanical track for non-contact ultrasound (US) scanning. The approach thus restricts the probe motion to a linear plane, to simplify the acquisition and 3D reconstruction process. A pipeline for US 3D volume reconstruction employing an US research platform and a GPU-based edge device is developed. Results: The efficacy of the proposed approach is demonstrated through ex-vivo and in-vivo experiments. Conclusion: The proposed approach with the adjustable field of view capability, non-contact design, and low cost of deployment without significantly altering the existing setup would open doors for up gradation of traditional systems to a wide range of 3D US imaging applications. Significance: Ultrasound (US) imaging is a popular clinical imaging modality for the point-of-care bedside imaging, particularly of the wrist/knee in the pediatric population due to its non-invasive and radiation free nature. However, the limited views of tissue structures obtained with 2D US in such scenarios make the diagnosis challenging. To overcome this, 3D US imaging which uses 2D US images and their orientation/position to reconstruct 3D volumes was developed. The accurate position estimation of the US probe at low cost has always stood as a challenging task in 3D reconstruction. Additionally, US imaging involves contact, which causes difficulty to pediatric subjects while monitoring live fractures or open wounds. Towards overcoming these challenges, a novel framework is attempted in this work.
△ Less
Submitted 6 October, 2023;
originally announced October 2023.
-
Fast Marching based Tissue Adaptive Delay Estimation for Aberration Corrected Delay and Sum Beamforming in Ultrasound Imaging
Authors:
M. S. Asif,
Gayathri Malamal,
A. N. Madhavanunni,
Vikram Melapudi,
V Rahul,
Abhijit Patil,
Rajesh Langoju,
Mahesh Raveendranatha Panicker
Abstract:
Conventional ultrasound (US) imaging employs the delay and sum (DAS) receive beamforming with dynamic receive focus for image reconstruction due to its simplicity and robustness. However, the DAS beamforming follows a geometrical method of delay estimation with a spatially constant speed-of-sound (SoS) of 1540 m/s throughout the medium irrespective of the tissue in-homogeneity. This approximation…
▽ More
Conventional ultrasound (US) imaging employs the delay and sum (DAS) receive beamforming with dynamic receive focus for image reconstruction due to its simplicity and robustness. However, the DAS beamforming follows a geometrical method of delay estimation with a spatially constant speed-of-sound (SoS) of 1540 m/s throughout the medium irrespective of the tissue in-homogeneity. This approximation leads to errors in delay estimations that accumulate with depth and degrades the resolution, contrast and overall accuracy of the US image. In this work, we propose a fast marching based DAS for focused transmissions which leverages the approximate SoS map to estimate the refraction corrected propagation delays for each pixel in the medium. The proposed approach is validated qualitatively and quantitatively for imaging depths of upto ~ 11 cm through simulations, where fat layer induced aberration is employed to alter the SoS in the medium. To the best of authors' knowledge, this is the first work considering the effect of SoS on image quality for deeper imaging.
△ Less
Submitted 19 April, 2023; v1 submitted 7 April, 2023;
originally announced April 2023.
-
A Simplified 3D Ultrasound Freehand Imaging Framework Using 1D Linear Probe and Low-Cost Mechanical Track
Authors:
Antony Jerald,
A. N. Madhavanunni,
Gayathri Malamal,
Pisharody Harikrishnan Gopalakrishnan,
Mahesh Raveendranatha Panicker
Abstract:
Ultrasound imaging is the most popular medical imaging modality for point-of-care bedside imaging. However, 2D ultrasound imaging provides only limited views of the organ of interest, making diagnosis challenging. To overcome this, 3D ultrasound imaging was developed, which uses 2D ultrasound images and their orientation/position to reconstruct 3D volumes. The accurate position estimation of the u…
▽ More
Ultrasound imaging is the most popular medical imaging modality for point-of-care bedside imaging. However, 2D ultrasound imaging provides only limited views of the organ of interest, making diagnosis challenging. To overcome this, 3D ultrasound imaging was developed, which uses 2D ultrasound images and their orientation/position to reconstruct 3D volumes. The accurate position estimation of the ultrasound probe at low cost has always stood as a challenging task in 3D reconstruction. In this study, we propose a novel approach of using a mechanical track for ultrasound scanning, which restricts the probe motion to a linear plane, simplifying the acquisition and hence the reconstruction process. We also present an end-to-end pipeline for 3D ultrasound volume reconstruction and demonstrate its efficacy with an in-vitro tube phantom study and an ex-vivo bone experiment. The comparison between a sensorless freehand and the proposed mechanical track based acquisition is available online (shorturl.at/jqvX0).
△ Less
Submitted 16 February, 2023;
originally announced February 2023.
-
Learning while Acquisition: Towards Active Learning Framework for Beamforming in Ultrasound Imaging
Authors:
Mayank Katare,
Mahesh Raveendranatha Panicker,
A N Madhavanunni,
Gayathri Malamal
Abstract:
In the recent past, there have been many efforts to accelerate adaptive beamforming for ultrasound (US) imaging using neural networks (NNs). However, most of these efforts are based on static models, i.e., they are trained to learn a single adaptive beamforming approach (e.g., minimum variance distortionless response (MVDR)) assuming that they result in the best image quality. Moreover, the traini…
▽ More
In the recent past, there have been many efforts to accelerate adaptive beamforming for ultrasound (US) imaging using neural networks (NNs). However, most of these efforts are based on static models, i.e., they are trained to learn a single adaptive beamforming approach (e.g., minimum variance distortionless response (MVDR)) assuming that they result in the best image quality. Moreover, the training of such NNs is initiated only after acquiring a large set of data that consumes several gigabytes (GBs) of storage space. In this study, an active learning framework for beamforming is described for the first time in the context of NNs. The best quality image chosen by the user serves as the ground truth for the proposed technique, which trains the NN concurrently with data acqusition. On average, the active learning approach takes 0.5 seconds to complete a single iteration of training.
△ Less
Submitted 31 July, 2022;
originally announced August 2022.
-
Patch Based Transformation for Minimum Variance Beamformer Image Approximation Using Delay and Sum Pipeline
Authors:
Sairoop Bodepudi,
A N Madhavanunni,
Mahesh Raveendranatha Panicker
Abstract:
In the recent past, there have been several efforts in accelerating computationally heavy beamforming algorithms such as minimum variance distortionless response (MVDR) beamforming to achieve real-time performance comparable to the popular delay and sum (DAS) beamforming. This has been achieved using a variety of neural network architectures ranging from fully connected neural networks (FCNNs), co…
▽ More
In the recent past, there have been several efforts in accelerating computationally heavy beamforming algorithms such as minimum variance distortionless response (MVDR) beamforming to achieve real-time performance comparable to the popular delay and sum (DAS) beamforming. This has been achieved using a variety of neural network architectures ranging from fully connected neural networks (FCNNs), convolutional neural networks (CNNs) and general adversarial networks (GANs). However most of these approaches are working with optimizations considering image level losses and hence require a significant amount of dataset to ensure that the process of beamforming is learned. In this work, a patch level U-Net based neural network is proposed, where the delay compensated radio frequency (RF) patch for a fixed region in space (e.g. 32x32) is transformed through a U-Net architecture and multiplied with DAS apodization weights and optimized for similarity with MVDR image of the patch. Instead of framing the beamforming problem as a regression problem to estimate the apodization weights, the proposed approach treats the non-linear transformation of the RF data space that can account for the data driven weight adaptation done by the MVDR approach in the parameters of the network. In this way, it is also observed that by restricting the input to a patch the model will learn the beamforming pipeline as an image non-linear transformation problem.
△ Less
Submitted 19 October, 2021;
originally announced October 2021.
-
Microcontroller Based Load Monitoring System
Authors:
A N Madhavanunni,
S S Arya,
Renjith Kumar D
Abstract:
The demand for power has increased exponentially over the last century. One avenue through which today's energy problems can be addressed is through the reduction of energy usage in households. This has increased the emphasis on the need for accurate and economic methods of power measurement. The goal of providing such data is to optimize and reduce their power consumption. In view of this, the pr…
▽ More
The demand for power has increased exponentially over the last century. One avenue through which today's energy problems can be addressed is through the reduction of energy usage in households. This has increased the emphasis on the need for accurate and economic methods of power measurement. The goal of providing such data is to optimize and reduce their power consumption. In view of this, the present manuscript focuses on the design and implementation of precise and reliable load monitoring system using PIC microcontroller chip (PIC16F877A). This involves an accurate sensing of voltage, current and power factor of the load. A clever utilization of in-built ADC and timers of the microcontroller reduces the design complexity of the system. The proposed system monitors the load continuously on a real time basis and displays the parameters such as voltage, current, power factor, active, reactive and apparent powers in an LCD module. The use of microcontroller reduces the cost and makes the device compact. The proposed system has been implemented and tested in the laboratory for single phase loads.
△ Less
Submitted 11 August, 2021;
originally announced August 2021.
-
A Nonlinear Beamforming for Enhanced Spatiotemporal Sensitivity in High Frame Rate Ultrasound Flow Imaging
Authors:
A. N. Madhavanunni,
Mahesh Raveendranatha Panicker
Abstract:
Typically, an ultrasound flow imaging system employs the conventional delay and sum (DAS) beamformer due to its inherent low complexity. But the conventional DAS technique offers poor contrast, low imaging resolution, and limited spatiotemporal sensitivity. This article attempts to improve the spatiotemporal sensitivity of conventional flow imaging with a novel multiply and sum based nonlinear hig…
▽ More
Typically, an ultrasound flow imaging system employs the conventional delay and sum (DAS) beamformer due to its inherent low complexity. But the conventional DAS technique offers poor contrast, low imaging resolution, and limited spatiotemporal sensitivity. This article attempts to improve the spatiotemporal sensitivity of conventional flow imaging with a novel multiply and sum based nonlinear high-resolution (NLHR) beamforming approach. The major advantages of the proposed beamformer are the harmonic generation and the enhanced coherence in beamformed signals that improve the spatiotemporal sensitivity towards flow transients. We demonstrate the proposed beamformer for a directional cross-correlation as well as an autocorrelation based velocity estimator with simulated parabolic flow profiles of different velocities and flow directions, an in-vitro rotating disk dataset, and pulsatile flow experiments. The sensitivity of NLHR beamforming towards the flow transients is validated in-vitro with a sudden reversal of flow direction and air bubble tracking experiments. The comparison between the time-frequency plots of DAS and NLHR beamforming indicates that the impulsive spatiotemporal changes induced by the flow of air bubbles are clearly characterized by nonlinear beamforming than that of DAS beamforming. Furthermore, better spatiotemporal velocity tracking of a single air bubble and a clear distinguishability between the tracking of two proximal air bubbles are observed in-vitro. Preliminary studies on the in-vivo carotid data also show comparable, if not better, results than that of the DAS algorithm. Detailed results for each test case in simulation, phantom, and in-vivo studies are available as movies with the supplementary material and online.
△ Less
Submitted 23 June, 2022; v1 submitted 5 August, 2021;
originally announced August 2021.
-
An Angle Independent Depth Aware Fusion Beamforming Approach for Ultrafast Ultrasound Flow Imaging
Authors:
A. N. Madhavanunni,
Mahesh Raveendranatha Panicker
Abstract:
In the case of vector flow imaging systems, the most employed flow estimation techniques are the directional beamforming based cross correlation and the triangulation-based autocorrelation. However, the directional beamforming-based techniques require an additional angle estimator and are not reliable if the flow angle is not constant throughout the region of interest. On the other hand, estimates…
▽ More
In the case of vector flow imaging systems, the most employed flow estimation techniques are the directional beamforming based cross correlation and the triangulation-based autocorrelation. However, the directional beamforming-based techniques require an additional angle estimator and are not reliable if the flow angle is not constant throughout the region of interest. On the other hand, estimates with triangulation-based techniques are prone to large bias and variance at low imaging depths due to limited angle for left and right apertures. In view of this, a novel angle independent depth aware fusion beamforming approach is proposed and evaluated in this paper. The hypothesis behind the proposed approach is that the peripheral flows are transverse in nature, where directional beamforming can be employed without the need of an angle estimator and the deeper flows being non-transverse and directional, triangulation-based vector flow imaging can be employed. In the simulation study, an overall 67.62% and 74.71% reduction in magnitude bias along with a slight reduction in the standard deviation are observed with the proposed fusion beamforming approach when compared to triangulation-based beamforming and directional beamforming, respectively, when implemented individually. The efficacy of the proposed approach is demonstrated with in-vivo experiments.
△ Less
Submitted 6 June, 2022; v1 submitted 5 August, 2021;
originally announced August 2021.
-
An Approach Towards Physics Informed Lung Ultrasound Image Scoring Neural Network for Diagnostic Assistance in COVID-19
Authors:
Mahesh Raveendranatha Panicker,
Yale Tung Chen,
Gayathri M,
Madhavanunni A N,
Kiran Vishnu Narayan,
C Kesavadas,
A P Vinod
Abstract:
Ultrasound is fast becoming an inevitable diagnostic tool for regular and continuous monitoring of the lung with the recent outbreak of COVID-19. In this work, a novel approach is presented to extract acoustic propagation-based features to automatically highlight the region below pleura, which is an important landmark in lung ultrasound (LUS). Subsequently, a multichannel input formed by using the…
▽ More
Ultrasound is fast becoming an inevitable diagnostic tool for regular and continuous monitoring of the lung with the recent outbreak of COVID-19. In this work, a novel approach is presented to extract acoustic propagation-based features to automatically highlight the region below pleura, which is an important landmark in lung ultrasound (LUS). Subsequently, a multichannel input formed by using the acoustic physics-based feature maps is fused to train a neural network, referred to as LUSNet, to classify the LUS images into five classes of varying severity of lung infection to track the progression of COVID-19. In order to ensure that the proposed approach is agnostic to the type of acquisition, the LUSNet, which consists of a U-net architecture is trained in an unsupervised manner with the acoustic feature maps to ensure that the encoder-decoder architecture is learning features in the pleural region of interest. A novel combination of the U-net output and the U-net encoder output is employed for the classification of severity of infection in the lung. A detailed analysis of the proposed approach on LUS images over the infection to full recovery period of ten confirmed COVID-19 subjects shows an average five-fold cross-validation accuracy, sensitivity, and specificity of 97%, 93%, and 98% respectively over 5000 frames of COVID-19 videos. The analysis also shows that, when the input dataset is limited and diverse as in the case of COVID-19 pandemic, an aided effort of combining acoustic propagation-based features along with the gray scale images, as proposed in this work, improves the performance of the neural network significantly and also aids the labelling and triaging process.
△ Less
Submitted 13 June, 2021;
originally announced June 2021.