-
Ultralight vector dark matter search using data from the KAGRA O3GK run
Authors:
The LIGO Scientific Collaboration,
the Virgo Collaboration,
the KAGRA Collaboration,
A. G. Abac,
R. Abbott,
H. Abe,
I. Abouelfettouh,
F. Acernese,
K. Ackley,
C. Adamcewicz,
S. Adhicary,
N. Adhikari,
R. X. Adhikari,
V. K. Adkins,
V. B. Adya,
C. Affeldt,
D. Agarwal,
M. Agathos,
O. D. Aguiar,
I. Aguilar,
L. Aiello,
A. Ain,
P. Ajith,
T. Akutsu,
S. Albanesi
, et al. (1778 additional authors not shown)
Abstract:
Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we prese…
▽ More
Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for $U(1)_{B-L}$ gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the $U(1)_{B-L}$ gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Search for Eccentric Black Hole Coalescences during the Third Observing Run of LIGO and Virgo
Authors:
The LIGO Scientific Collaboration,
the Virgo Collaboration,
the KAGRA Collaboration,
A. G. Abac,
R. Abbott,
H. Abe,
F. Acernese,
K. Ackley,
C. Adamcewicz,
S. Adhicary,
N. Adhikari,
R. X. Adhikari,
V. K. Adkins,
V. B. Adya,
C. Affeldt,
D. Agarwal,
M. Agathos,
O. D. Aguiar,
I. Aguilar,
L. Aiello,
A. Ain,
P. Ajith,
T. Akutsu,
S. Albanesi,
R. A. Alfaidi
, et al. (1750 additional authors not shown)
Abstract:
Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effect…
▽ More
Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass $M>70$ $M_\odot$) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities $0 < e \leq 0.3$ at $0.33$ Gpc$^{-3}$ yr$^{-1}$ at 90\% confidence level.
△ Less
Submitted 7 August, 2023;
originally announced August 2023.
-
SAGE: A Proposal for a Space Atomic Gravity Explorer
Authors:
G. M. Tino,
A. Bassi,
G. Bianco,
K. Bongs,
P. Bouyer,
L. Cacciapuoti,
S. Capozziello,
X. Chen,
M. L. Chiofalo,
A. Derevianko,
W. Ertmer,
N. Gaaloul,
P. Gill,
P. W. Graham,
J. M. Hogan,
L. Iess,
M. A. Kasevich,
H. Katori,
C. Klempt,
X. Lu,
L. -S. Ma,
H. Müller,
N. R. Newbury,
C. Oates,
A. Peters
, et al. (22 additional authors not shown)
Abstract:
The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.
The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.
△ Less
Submitted 18 November, 2019; v1 submitted 8 July, 2019;
originally announced July 2019.
-
Making optical atomic clocks more stable with $10^{-16}$ level laser stabilization
Authors:
Y. Y. Jiang,
A. D. Ludlow,
N. D. Lemke,
R. W. Fox,
J. A. Sherman,
L. -S. Ma,
C. W. Oates
Abstract:
The superb precision of an atomic clock is derived from its stability. Atomic clocks based on optical (rather than microwave) frequencies are attractive because of their potential for high stability, which scales with operational frequency. Nevertheless, optical clocks have not yet realized this vast potential, due in large part to limitations of the laser used to excite the atomic resonance. To a…
▽ More
The superb precision of an atomic clock is derived from its stability. Atomic clocks based on optical (rather than microwave) frequencies are attractive because of their potential for high stability, which scales with operational frequency. Nevertheless, optical clocks have not yet realized this vast potential, due in large part to limitations of the laser used to excite the atomic resonance. To address this problem, we demonstrate a cavity-stabilized laser system with a reduced thermal noise floor, exhibiting a fractional frequency instability of $2 \times 10^{-16}$. We use this laser as a stable optical source in a Yb optical lattice clock to resolve an ultranarrow 1 Hz transition linewidth. With the stable laser source and the signal to noise ratio (S/N) afforded by the Yb optical clock, we dramatically reduce key stability limitations of the clock, and make measurements consistent with a clock instability of $5 \times 10^{-16} / \sqrtτ$.
△ Less
Submitted 6 January, 2011;
originally announced January 2011.