-
Particle Physics at the European Spallation Source
Authors:
H. Abele,
A. Alekou,
A. Algora,
K. Andersen,
S. Baessler,
L. Barron-Palos,
J. Barrow,
E. Baussan,
P. Bentley,
Z. Berezhiani,
Y. Bessler,
A. K. Bhattacharyya,
A. Bianchi,
J. Bijnens,
C. Blanco,
N. Blaskovic Kraljevic,
M. Blennow,
K. Bodek,
M. Bogomilov,
C. Bohm,
B. Bolling,
E. Bouquerel,
G. Brooijmans,
L. J. Broussard,
O. Buchan
, et al. (154 additional authors not shown)
Abstract:
Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons…
▽ More
Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).
△ Less
Submitted 30 January, 2024; v1 submitted 18 November, 2022;
originally announced November 2022.
-
Gaussian Processes and Bayesian Optimization for High Precision Experiments
Authors:
Max Lamparth,
Mattis Bestehorn,
Bastian Märkisch
Abstract:
High-precision measurements require optimal setups and analysis tools to achieve continuous improvements. Systematic corrections need to be modeled with high accuracy and known uncertainty to reconstruct underlying physical phenomena. To this end, we present Gaussian processes for modeling experiments and usage with Bayesian optimization, on the example of an electron energy detector, achieving op…
▽ More
High-precision measurements require optimal setups and analysis tools to achieve continuous improvements. Systematic corrections need to be modeled with high accuracy and known uncertainty to reconstruct underlying physical phenomena. To this end, we present Gaussian processes for modeling experiments and usage with Bayesian optimization, on the example of an electron energy detector, achieving optimal performance. We demonstrate the method's strengths and outline stochastic variational Gaussian processes for physics applications with large data sets, enabling new solutions for current problems.
△ Less
Submitted 27 May, 2022; v1 submitted 16 May, 2022;
originally announced May 2022.
-
A non-depolarizing CuTi neutron supermirror guide for PERC
Authors:
A. Hollering,
N. Rebrova,
C. Klauser,
Th. Lauer,
B. Märkisch,
U. Schmidt
Abstract:
Neutron guides are used to transport slow neutrons from sources to experiments. Conventional neutron supermirror guides use alternating thin layers based on nickel and titanium. Due to the magnetic properties of nickel, their neutron reflection properties are spin-dependent, in particular when exposed to high magnetic fields. Motivated by the requirements of precision experiments on neutron beta d…
▽ More
Neutron guides are used to transport slow neutrons from sources to experiments. Conventional neutron supermirror guides use alternating thin layers based on nickel and titanium. Due to the magnetic properties of nickel, their neutron reflection properties are spin-dependent, in particular when exposed to high magnetic fields. Motivated by the requirements of precision experiments on neutron beta decay, we present novel supermirrors based on copper and titanium, which preserve the neutron beam polarization. These show excellent reflectivity and prove to be very stable even when exposed to high temperatures.
△ Less
Submitted 10 March, 2022; v1 submitted 1 December, 2021;
originally announced December 2021.
-
Precise Measurements of the Decay of Free Neutrons
Authors:
Dirk Dubbers,
Bastian Märkisch
Abstract:
The impact of new and highly precise neutron \b{eta} decay data is reviewed. We focus on recent results from neutron lifetime, \b{eta} asymmetry, and electron-neutrino correlation experiments. From these results, weak interaction parameters are extracted with unprecedented precision, possible also due to progress in effective field theory and lattice QCD. Limits on New Physics beyond the Standard…
▽ More
The impact of new and highly precise neutron \b{eta} decay data is reviewed. We focus on recent results from neutron lifetime, \b{eta} asymmetry, and electron-neutrino correlation experiments. From these results, weak interaction parameters are extracted with unprecedented precision, possible also due to progress in effective field theory and lattice QCD. Limits on New Physics beyond the Standard Model derived from neutron decay data are sharper than those derived from high-energy experiments, except for processes involving right-handed neutrinos.
△ Less
Submitted 4 June, 2021;
originally announced June 2021.
-
Search for a muon EDM using the frozen-spin technique
Authors:
A. Adelmann,
M. Backhaus,
C. Chavez Barajas,
N. Berger,
T. Bowcock,
C. Calzolaio,
G. Cavoto,
R. Chislett,
A. Crivellin,
M. Daum,
M. Fertl,
M. Giovannozzi,
G. Hesketh,
M. Hildebrandt,
I. Keshelashvili,
A. Keshavarzi,
K. S. Khaw,
K. Kirch,
A. Kozlinskiy,
A. Knecht,
M. Lancaster,
B. Märkisch,
F. Meier Aeschbacher,
F. Méot,
A. Nass
, et al. (13 additional authors not shown)
Abstract:
This letter of intent proposes an experiment to search for an electric dipole moment of the muon based on the frozen-spin technique. We intend to exploit the high electric field, $E=1{\rm GV/m}$, experienced in the rest frame of the muon with a momentum of $p=125 {\rm MeV/}c$ when passing through a large magnetic field of $|\vec{B}|=3{\rm T}$. Current muon fluxes at the $μ$E1 beam line permit an i…
▽ More
This letter of intent proposes an experiment to search for an electric dipole moment of the muon based on the frozen-spin technique. We intend to exploit the high electric field, $E=1{\rm GV/m}$, experienced in the rest frame of the muon with a momentum of $p=125 {\rm MeV/}c$ when passing through a large magnetic field of $|\vec{B}|=3{\rm T}$. Current muon fluxes at the $μ$E1 beam line permit an improved search with a sensitivity of $σ(d_μ)\leq 6\times10^{-23}e{\rm cm}$, about three orders of magnitude more sensitivity than for the current upper limit of $|d_μ|\leq1.8\times10^{-19}e{\rm cm}$\,(C.L. 95\%). With the advent of the new high intensity muon beam, HIMB, and the cold muon source, muCool, at PSI the sensitivity of the search could be further improved by tailoring a re-acceleration scheme to match the experiments injection phase space. While a null result would set a significantly improved upper limit on an otherwise un-constrained Wilson coefficient, the discovery of a muon EDM would corroborate the existence of physics beyond the Standard Model.
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
Limit on the Fierz Interference Term b from a Measurement of the Beta Asymmetry in Neutron Decay
Authors:
Heiko Saul,
Christoph Roick,
Hartmut Abele,
Holger Mest,
Michael Klopf,
Alexander Petukhov,
Torsten Soldner,
Xiangzun Wang,
Dominik Werder,
Bastian Märkisch
Abstract:
In the standard model of particle physics, the weak interaction is described by vector and axial-vector couplings only. Non-zero scalar or tensor interactions would imply an additional contribution to the differential decay rate of the neutron, the Fierz interference term. We derive a limit on this hypothetical term from a measurement using spin polarized neutrons. This method is statistically les…
▽ More
In the standard model of particle physics, the weak interaction is described by vector and axial-vector couplings only. Non-zero scalar or tensor interactions would imply an additional contribution to the differential decay rate of the neutron, the Fierz interference term. We derive a limit on this hypothetical term from a measurement using spin polarized neutrons. This method is statistically less sensitive than the determination from the spectral shape but features much cleaner systematics. We obtain a limit of b = 0.017(21) at 68.27 C.L., improving the previous best limit from neutron decay by a factor of four.
△ Less
Submitted 22 July, 2020; v1 submitted 5 November, 2019;
originally announced November 2019.
-
Towards a first measurement of the free neutron bound beta decay detecting hydrogen atoms at a throughgoing beamtube in a high flux reactor
Authors:
Wolfgang Schott,
Erwin Gutsmiedl,
Karina Bernert,
Ralf Engels,
Roman Gernhäuser,
Stefan Huber,
Igor Konorov,
Bastian Märkisch,
Stephan Paul,
Christoph Roick,
Heiko Saul,
Suzana Spasova
Abstract:
In addition to the common 3-body decay of the neutron $n\rightarrow p e^-\overline{ν_e}$ there should exist an effective 2-body subset with the electron and proton forming a Hydrogen bound state with well defined total momentum, total spin and magnetic quantum numbers. The atomic spectroscopic analysis of this bound system can reveal details about the underlying weak interaction as it mirrors the…
▽ More
In addition to the common 3-body decay of the neutron $n\rightarrow p e^-\overline{ν_e}$ there should exist an effective 2-body subset with the electron and proton forming a Hydrogen bound state with well defined total momentum, total spin and magnetic quantum numbers. The atomic spectroscopic analysis of this bound system can reveal details about the underlying weak interaction as it mirrors the helicity distributions of all outgoing particles. Thus, it is unique in the information it carries, and an experiment unravelling this information is an analogue to the Goldhaber experiment performed more than 60 years ago. The proposed experiment will search for monoenergetic metastable BoB H atoms with 326 eV kinetic energy, which are generated at the center of a throughgoing beamtube of a high-flux reactor (e.g., at the PIK reactor, Gatchina). Although full spectroscopic information is needed to possibly reveal new physics our first aim is to prove the occurrence of this decay and learn about backgrounds. Key to the detection is the identification of a monoerergtic line of hydrogen atoms occurring at a rate of about 1 $\rm{s}^{-1}$ in the environment of many hydrogen atoms, however having a thermal distribution of about room temperature. Two scenarios for velocity (energy) filtering are discussed in this paper. The first builds on an purely electric chopper system, in which metastable hydrogen atoms are quenched to their ground state and thus remain mostly undetectable. This chopper system employs fast switchable Bradbury Nielsen gates. The second method exploits a strongly energy dependent charge exchange process of metastable hydrogen picking up an electron while traversing an argon filled gas cell, turning it into manipulable charged hydrogen. The final detection of hydrogen occurs through multichannel plate (MCP) detector.
△ Less
Submitted 10 October, 2019;
originally announced October 2019.
-
Design of the Magnet System of the Neutron Decay Facility PERC
Authors:
Xiangzun Wang,
Carmen Ziener,
Hartmut Abele,
Stefan Bodmaier,
Dirk Dubbers,
Jaqueline Erhart,
Alexander Hollering,
Erwin Jericha,
Jens Klenke,
Harald Fillunger,
Werner Heil,
Christine Klauser,
Gertrud Konrad,
Max Lamparth,
Thorsten Lauer,
Michael Klopf,
Reinhard Maix,
Bastian Märkisch,
Wilfried Mach,
Holger Mest,
Daniel Moser,
Alexander Pethoukov,
Lukas Raffelt,
Nataliya Rebrova,
Christoph Roick
, et al. (5 additional authors not shown)
Abstract:
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element $V_{ud}$ from neutron decay data and to search for new…
▽ More
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element $V_{ud}$ from neutron decay data and to search for new physics via new effective couplings. PERC's central component is a 12m long superconducting magnet system. It hosts an 8m long decay region in a uniform field. An additional high-field region selects the phase space of electrons and protons which can reach the detectors and largely improves systematic uncertainties. We discuss the design of the magnet system and the resulting properties of the magnetic field.
△ Less
Submitted 24 May, 2019;
originally announced May 2019.
-
Undetected Electron Backscattering in PERKEO III
Authors:
Christoph Roick,
Heiko Saul,
Hartmut Abele,
Bastian Märkisch
Abstract:
The beta asymmetry in neutron beta decay is used to determine the ratio of axial-vector coupling to vector coupling most precisely. In electron spectroscopy, backscattering of electrons from detectors can be a major source of systematic error. We present the determination of the correction for undetected backscattering for electron detection with the instrument PERKEO III. For the electron asymmet…
▽ More
The beta asymmetry in neutron beta decay is used to determine the ratio of axial-vector coupling to vector coupling most precisely. In electron spectroscopy, backscattering of electrons from detectors can be a major source of systematic error. We present the determination of the correction for undetected backscattering for electron detection with the instrument PERKEO III. For the electron asymmetry, undetected backscattering leads to a fractional correction of $5\times 10^{-4}$, i.e. a change by 40% of the total systematic uncertainty.
△ Less
Submitted 24 May, 2019;
originally announced May 2019.
-
Constraints on the Dark Matter Interpretation $n \rightarrow χ+ e^+ e^-$ of the Neutron Decay Anomaly with the PERKEO II experiment
Authors:
M. Klopf,
E. Jericha,
B. Märkisch,
H. Saul,
T. Soldner,
H. Abele
Abstract:
Discrepancies from in-beam and in-bottle type experiments measuring the neutron lifetime are on the 4$σ$ standard deviation level. In a recent publication Fornal and Grinstein proposed that the puzzle could be solved if the neutron would decay on the one percent level via a dark decay mode, one possible branch being $n \rightarrow χ+ e^+ e^-$. With data from the \perkeoII experiment we set limits…
▽ More
Discrepancies from in-beam and in-bottle type experiments measuring the neutron lifetime are on the 4$σ$ standard deviation level. In a recent publication Fornal and Grinstein proposed that the puzzle could be solved if the neutron would decay on the one percent level via a dark decay mode, one possible branch being $n \rightarrow χ+ e^+ e^-$. With data from the \perkeoII experiment we set limits on the branching fraction and exclude a one percent contribution for $95\,\%$ of the allowed mass range for the dark matter particle.
△ Less
Submitted 7 May, 2019; v1 submitted 6 May, 2019;
originally announced May 2019.
-
Measurement of the Weak Axial-Vector Coupling Constant in the Decay of Free Neutrons Using a Pulsed Cold Neutron Beam
Authors:
Bastian Märkisch,
Holger Mest,
Heiko Saul,
Xiangzun Wang,
Hartmut Abele,
Dirk Dubbers,
Michael Klopf,
Alexander Petoukhov,
Christoph Roick,
Torsten Soldner,
Dominik Werder
Abstract:
We present a precision measurement of the axial-vector coupling constant $g_A$ in the decay of polarized free neutrons. For the first time, a pulsed cold neutron beam was used for this purpose. By this method, leading sources of systematic uncertainty are suppressed. From the electron spectra we obtain $λ= g_A/g_V = -1.27641(45)_\mathrm{stat}(33)_\mathrm{sys}$ which confirms recent measurements wi…
▽ More
We present a precision measurement of the axial-vector coupling constant $g_A$ in the decay of polarized free neutrons. For the first time, a pulsed cold neutron beam was used for this purpose. By this method, leading sources of systematic uncertainty are suppressed. From the electron spectra we obtain $λ= g_A/g_V = -1.27641(45)_\mathrm{stat}(33)_\mathrm{sys}$ which confirms recent measurements with improved precision. This corresponds to a value of the parity violating beta asymmetry parameter of $A_0 = -0.11985(17)_\mathrm{stat}(12)_\mathrm{sys}$. We discuss implications on the CKM matrix element $V_{ud}$ and derive a limit on left-handed tensor interaction.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
Exotic decay channels are not the cause of the neutron lifetime anomaly
Authors:
D. Dubbers,
H. Saul,
B. Märkisch,
T. Soldner,
H. Abele
Abstract:
Since long neutron lifetimes measured with a beam of cold neutrons are significantly different from lifetimes measured with ultracold neutrons bottled in a trap. It is often speculated that this "neutron anomaly" is due to an exotic dark neutron decay channel of unknown origin. We show that this explanation of the neutron anomaly can be excluded with a high level of confidence when use is made of…
▽ More
Since long neutron lifetimes measured with a beam of cold neutrons are significantly different from lifetimes measured with ultracold neutrons bottled in a trap. It is often speculated that this "neutron anomaly" is due to an exotic dark neutron decay channel of unknown origin. We show that this explanation of the neutron anomaly can be excluded with a high level of confidence when use is made of new data on neutron decay parameters. Furthermore, data from neutron decay now compare well with Ft data derived from nuclear \b{eta} decays.
△ Less
Submitted 18 December, 2018; v1 submitted 3 December, 2018;
originally announced December 2018.
-
ANNI - A pulsed cold neutron beam facility for particle physics at the ESS
Authors:
Torsten Soldner,
Hartmut Abele,
Gertrud Konrad,
Bastian Märkisch,
Florian M. Piegsa,
Ulrich Schmidt,
Camille Theroine,
Pablo Torres Sánchez
Abstract:
Pulsed beams have tremendous advantages for precision experiments with cold neutrons. In order to minimise and measure systematic effects, they are used at continuous sources in spite of the related substantial decrease in intensity. At the European Spallation Source ESS these experiments will profit from the pulse structure of the source and its 50 times higher peak brightness compared to the mos…
▽ More
Pulsed beams have tremendous advantages for precision experiments with cold neutrons. In order to minimise and measure systematic effects, they are used at continuous sources in spite of the related substantial decrease in intensity. At the European Spallation Source ESS these experiments will profit from the pulse structure of the source and its 50 times higher peak brightness compared to the most intense reactor facilities, making novel concepts feasible. Therefore, the cold neutron beam facility for particle physics ANNI was proposed as part of the ESS instrument suite. The proposed design has been re-optimised to take into account the present ESS cold moderator layout. We present design considerations, the optimised instrument parameters and performance, and expected gain factors for several reference experiments.
△ Less
Submitted 28 November, 2018;
originally announced November 2018.
-
High Precision Experiments with Cold and Ultra-Cold Neutrons
Authors:
Hartmut Abele,
Tobias Jenke,
Erwin Jericha,
Gertrud Konrad,
Bastian Märkisch,
Christian Plonka,
Ulrich Schmidt,
Torsten Soldner
Abstract:
This work presents selected results from the first round of the DFG Priority Programme SPP 1491 "precision experiments in particle and astroparticle physics with cold and ultra-cold neutrons".
This work presents selected results from the first round of the DFG Priority Programme SPP 1491 "precision experiments in particle and astroparticle physics with cold and ultra-cold neutrons".
△ Less
Submitted 16 December, 2014;
originally announced December 2014.
-
Measurement of the Axial-Vector Coupling Constant $g_A$ in Neutron Beta Decay
Authors:
Bastian Maerkisch,
Hartmut Abele
Abstract:
The matrix element \Vud of the CKM matrix can be determined by two independent measurements in neutron decay: the neutron lifetime $τ_n$ and the ratio of coupling constants $λ=g_A/g_V$, which is most precisely determined by measurements of the beta asymmetry angular correlation coefficient~$A$. We present recent progress on the determination of these coupling constants.
The matrix element \Vud of the CKM matrix can be determined by two independent measurements in neutron decay: the neutron lifetime $τ_n$ and the ratio of coupling constants $λ=g_A/g_V$, which is most precisely determined by measurements of the beta asymmetry angular correlation coefficient~$A$. We present recent progress on the determination of these coupling constants.
△ Less
Submitted 15 October, 2014;
originally announced October 2014.
-
Determination of the Weak Axial Vector Coupling from a Measurement of the Beta-Asymmetry Parameter A in Neutron Beta Decay
Authors:
D. Mund,
B. Maerkisch,
M. Deissenroth,
J. Krempel,
M. Schumann,
H. Abele,
A. Petoukhov,
T. Soldner
Abstract:
We report on a new measurement of the neutron beta-asymmetry parameter $A$ with the instrument \perkeo. Main advancements are the high neutron polarization of $P = 99.7(1)%$ from a novel arrangement of super mirror polarizers and reduced background from improvements in beam line and shielding. Leading corrections were thus reduced by a factor of 4, pushing them below the level of statistical error…
▽ More
We report on a new measurement of the neutron beta-asymmetry parameter $A$ with the instrument \perkeo. Main advancements are the high neutron polarization of $P = 99.7(1)%$ from a novel arrangement of super mirror polarizers and reduced background from improvements in beam line and shielding. Leading corrections were thus reduced by a factor of 4, pushing them below the level of statistical error and resulting in a significant reduction of systematic uncertainty compared to our previous experiments. From the result $A_0 = -0.11996(58)$, we derive the ratio of the axial-vector to the vector coupling constant $λ= g_\mathrm{A}/g_\mathrm{V} = -1.2767(16)$
△ Less
Submitted 30 March, 2012;
originally announced April 2012.
-
Experimental Status of Vud from Neutron Decay
Authors:
Bastian Märkisch
Abstract:
The matrix element Vud of the CKM matrix can be determined by two independent measurements on neutron decay: the neutron lifetime tau and the ratio of coupling constants lambda, which is most precisely determined by measurements of the beta asymmetry angular correlation coefficient A. We present recent progress on the determination of these values and derive a world average of Vud = 0.9743 (2)RC (…
▽ More
The matrix element Vud of the CKM matrix can be determined by two independent measurements on neutron decay: the neutron lifetime tau and the ratio of coupling constants lambda, which is most precisely determined by measurements of the beta asymmetry angular correlation coefficient A. We present recent progress on the determination of these values and derive a world average of Vud = 0.9743 (2)RC (8)tau (12)lambda.
△ Less
Submitted 20 July, 2011; v1 submitted 18 July, 2011;
originally announced July 2011.
-
The point spread function of electrons in a magnetic field, and the decay of the free neutron
Authors:
D. Dubbers,
L. Raffelt,
B. Maerkisch,
F. Friedl,
H. Abele
Abstract:
Experiments in nuclear and particle physics often use magnetic fields to guide charged reaction products to a detector. Due to their gyration in the guide field, the particles hit the detector within an area that can be considerably larger than the diameter of the source where the particles are produced. This blurring of the image of the particle source on the detector surface is described by a su…
▽ More
Experiments in nuclear and particle physics often use magnetic fields to guide charged reaction products to a detector. Due to their gyration in the guide field, the particles hit the detector within an area that can be considerably larger than the diameter of the source where the particles are produced. This blurring of the image of the particle source on the detector surface is described by a suitable point spread function (PSF), which is defined as the image of a point source. We derive simple analytical expressions for such magnetic PSFs, valid for any angular distribution of the emitted particles that can be developed in Legendre polynomials. We investigate this rather general problem in the context of neutron beta decay spectrometers and study the effect of limited detector size on measured neutron decay correlation parameters. To our surprise, insufficient detector size does not affect much the accuracy of such measurements, even for rather large radii of gyration. This finding can considerably simplify the layout of the respective spectrometers.
△ Less
Submitted 26 June, 2014; v1 submitted 1 December, 2008;
originally announced December 2008.
-
Measurement of the Proton Asymmetry Parameter C in Neutron Beta Decay
Authors:
M. Schumann,
M. Kreuz,
M. Deissenroth,
F. Glueck,
J. Krempel,
B. Maerkisch,
D. Mund,
A. Petoukhov,
T. Soldner,
H. Abele
Abstract:
The proton asymmetry parameter C in neutron decay describes the correlation between neutron spin and proton momentum. In this Letter, the first measurement of this quantity is presented. The result C=-0.2377(26) agrees with the Standard Model expectation. The coefficient C provides an additional parameter for new and improved Standard Model tests. From a differential analysis of the same data (a…
▽ More
The proton asymmetry parameter C in neutron decay describes the correlation between neutron spin and proton momentum. In this Letter, the first measurement of this quantity is presented. The result C=-0.2377(26) agrees with the Standard Model expectation. The coefficient C provides an additional parameter for new and improved Standard Model tests. From a differential analysis of the same data (assuming the Standard Model), we obtain lambda=-1.275(16) as ratio of axial-vector and vector coupling constant.
△ Less
Submitted 14 December, 2007;
originally announced December 2007.
-
A clean, bright, and versatile source of neutron decay products
Authors:
D. Dubbers,
H. Abele,
S. Baessler,
B. Maerkisch,
M. Schumann,
T. Soldner,
O. Zimmer
Abstract:
We present a case study on a new type of cold neutron beam station for the investigation of angular correlations in the beta-decay of free neutrons. With this beam station, called PERC, the 'active decay volume' lies inside the neutron guide, and the charged neutron decay products are magnetically guided towards the end of the neutron guide. Hence, the guide delivers at its exit a beam of decay…
▽ More
We present a case study on a new type of cold neutron beam station for the investigation of angular correlations in the beta-decay of free neutrons. With this beam station, called PERC, the 'active decay volume' lies inside the neutron guide, and the charged neutron decay products are magnetically guided towards the end of the neutron guide. Hence, the guide delivers at its exit a beam of decay electrons and protons, under well-defined and precisely variable conditions, which can be well separated from the cold neutron beam. In this way a general-purpose source of neutron decay products is obtained which can be used for various different experiments in neutron decay correlation spectroscopy. A gain in phase space density of several orders of magnitude can be achieved with PERC, as compared to existing neutron decay spectrometers. Neutron beam related background is separately measurable in PERC, and magnetic mirror effects on the charged neutron decay products and edge effects in the active neutron beam volume are both strongly suppressed. Therefore the spectra and angular distributions of the emerging decay particles will be distortion-free on the level of 10^-4, more than 10 times better than achieved today.
△ Less
Submitted 27 September, 2007;
originally announced September 2007.
-
Measurement of the Neutrino Asymmetry Parameter B in Neutron Decay
Authors:
M. Schumann,
T. Soldner,
M. Deissenroth,
F. Glueck,
J. Krempel,
M. Kreuz,
B. Maerkisch,
D. Mund,
A. Petoukhov,
H. Abele
Abstract:
A new measurement of the neutrino asymmetry parameter B in neutron decay, the angular correlation between neutron spin and anti-neutrino momentum, is presented. The result, B=0.9802(50), agrees with the Standard Model expectation and earlier measurements, and permits improved tests on ``new physics'' in neutron decay.
A new measurement of the neutrino asymmetry parameter B in neutron decay, the angular correlation between neutron spin and anti-neutrino momentum, is presented. The result, B=0.9802(50), agrees with the Standard Model expectation and earlier measurements, and permits improved tests on ``new physics'' in neutron decay.
△ Less
Submitted 10 November, 2007; v1 submitted 26 June, 2007;
originally announced June 2007.
-
Characterization of a ballistic supermirror neutron guide
Authors:
H. Abele,
D. Dubbers,
H. Haese,
M. Klein,
A. Knoepfler,
M. Kreuz,
T. Lauer,
B. Maerkisch,
D. Mund,
V. Nesvizhevsky,
A. Petoukhov,
C. Schmidt,
M. Schumann,
T. Soldner
Abstract:
We describe the beam characteristics of the first ballistic supermirror neutron guide H113 that feeds the neutron user facility for particle physics PF1B of the Institute Laue-Langevin, Grenoble (ILL). At present, the neutron capture flux density of H113 at its 20x6cm2 exit window is 1.35x10^10/cm^2/s, and will soon be raised to above 2x10^10/cm^2/s. Beam divergence is no larger than beam diverg…
▽ More
We describe the beam characteristics of the first ballistic supermirror neutron guide H113 that feeds the neutron user facility for particle physics PF1B of the Institute Laue-Langevin, Grenoble (ILL). At present, the neutron capture flux density of H113 at its 20x6cm2 exit window is 1.35x10^10/cm^2/s, and will soon be raised to above 2x10^10/cm^2/s. Beam divergence is no larger than beam divergence from a conventional Ni coated guide. A model is developed that permits rapid calculation of beam profiles and absolute event rates from such a beam. We propose a procedure that permits inter-comparability of the main features of beams emitted from ballistic or conventional neutron guides.
△ Less
Submitted 26 October, 2005;
originally announced October 2005.