Skip to main content

Showing 1–7 of 7 results for author: Lyashenko, A V

.
  1. arXiv:1909.10399  [pdf, other

    physics.ins-det nucl-ex physics.med-ph

    Performance of Large Area Picosecond Photo-Detectors (LAPPD)

    Authors: A. V. Lyashenko, B. W. Adams, M. Aviles, T. Cremer, C. D. Ertley, M. R. Foley, M. J. Minot, M. A. Popecki, M. E. Stochaj, W. A. Worstell, J. W. Elam, A. U. Mane, O. H. W. Siegmund, H. J. Frisch, A. L. Elagin, E. Angelico, E. Spieglan

    Abstract: We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single ph… ▽ More

    Submitted 23 September, 2019; originally announced September 2019.

    Comments: accepted for publication at NIMA

  2. Towards THGEM UV-photon detectors for RICH: on single-photon detection efficiency in Ne/CH4 and Ne/CF4

    Authors: C. D. R. Azevedo, M. Cortesi, A. V. Lyashenko, A. Breskin, R. Chechik, J. Miyamoto, V. Peskov, J. Escada, J. F. C. A. Veloso, J. M. F. dos Santos

    Abstract: The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron extraction efficiency from the photocathode into these gas mixtures, and on the photoelectron collection efficiency into the THGEM holes. Full collection efficie… ▽ More

    Submitted 29 September, 2009; originally announced September 2009.

    Comments: 13 pages, 9 figures, 1 table. Presented at MPGD09, Crete, June 2009; to be published in JINST-proceedings

    Journal ref: JINST 5:P01002,2010

  3. Development of high-gain gaseous photomultipliers for the visible spectral range

    Authors: A. V. Lyashenko, A. Breskin, R. Chechik, J. M. F. Dos Santos, F. D. Amaro, J. F. C. A. Veloso

    Abstract: We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the elec… ▽ More

    Submitted 5 May, 2009; v1 submitted 1 May, 2009; originally announced May 2009.

    Comments: 22 pages, 12 figures, for submission to JINST

    Journal ref: A. Lyashenko et al., JINST 4 (2009) P07005

  4. Efficient ion blocking in gaseous detectors and its application to gas-avalanche photomultipliers sensitive in the visible-light range

    Authors: A. V. Lyashenko, A. Breskin, R. Chechik, J. M. F. Dos Santos, F. D. Amaro, J. F. C. A. Veloso

    Abstract: A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in operation conditions adequate for TPCs and for gaseous photomultipliers. The concept was validated in a cascaded visible-sensitive gas avalanche photomultiplier… ▽ More

    Submitted 28 April, 2008; originally announced April 2008.

    Comments: Proceeding paper to 10-th International Conference On Instrumentation For Colliding Beam Physics, Budker Institute of Nuclear Physics, Novosibirsk, Russia, February 28 - March 5, 2008, Submitted to NIMA, 5 pages, 7 figures

    Journal ref: A. Lyashenko et al., Nucl. Instr. and Meth. A 598 (2009) 116

  5. arXiv:0706.3606  [pdf, ps, other

    physics.ins-det physics.med-ph

    Further progress in ion back-flow reduction with patterned gaseous hole-multipliers

    Authors: A. V. Lyashenko, A. Breskin, R. Chechik, J. F. C. A. Veloso, J. M. F. Dos Santos, F. D. Amaro

    Abstract: A new idea on electrostatic deviation and capture of back-drifting avalanche-ions in cascaded gaseous hole-multipliers is presented. It involves a flipped reversed-bias Micro-Hole & Strip Plate (F-R-MHSP) element, the strips of which are facing the drift region of the multiplier. The ions, originating from successive multiplication stages, are efficiently deviated and captured by such electrode.… ▽ More

    Submitted 14 August, 2007; v1 submitted 25 June, 2007; originally announced June 2007.

    Comments: 17 pages, 11 figures, published in JINST

    Journal ref: JINST2:P08004,2007

  6. Advances in ion back-flow reduction in cascaded gaseous electron multipliers incorporating R-MHSP elements

    Authors: A. V. Lyashenko, A. Breskin, R. Chechik, J. F. C. A. Veloso, J. M. F. Dos Santos, F. D. Amaro

    Abstract: A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of magnitude reduction in ion back-flow is achieved by diverting back-drifting ions from their original path. A R-MHSP/2GEM/MHSP cascaded multiplier operated at total ga… ▽ More

    Submitted 3 July, 2006; originally announced July 2006.

    Comments: 17 pages, 9 figures, submitted to JINST

    Journal ref: 2006 JINST 1 P10004

  7. MHSP in reversed-biased operation mode for ion blocking in gas-avalanche multipliers

    Authors: J. F. C. A. Veloso, F. Amaro, J. M. Maia, A. V. Lyashenko, A. Breskin, R. Chechik, J. M. F. dos Santos, O. Bouianov, M. Bouianov

    Abstract: We present recent results on the operation of gas-avalanche detectors comprising a cascade of gas electron multipliers (GEMs) and Micro-Hole and Strip Plates (MHSPs) multiplier operated in reversed-bias (R-MHSP) mode. The operation mechanism of the R-MHSP is explained and its potential contribution to ion-backflow (IBF) reduction is demonstrated. IBF values of 4E-3 were obtained in cascaded R-MH… ▽ More

    Submitted 31 March, 2005; originally announced March 2005.

    Comments: 23 pages, 8 figures

    Journal ref: Nucl.Instrum.Meth. A548 (2005) 375-382