Skip to main content

Showing 1–14 of 14 results for author: Lussi, D

.
  1. ArDM: first results from underground commissioning

    Authors: A. Badertscher, F. Bay, N. Bourgeois, C. Cantini, A. Curioni, M. Daniel, U. Degunda, S. Di Luise, L. Epprecht, A. Gendotti, S. Horikawa, L. Knecht, D. Lussi, G. Maire, B. Montes, S. Murphy, G. Natterer, K. Nikolics, K. Nguyen, L. Periale, S. Ravat, F. Resnati, L. Romero, A. Rubbia, R. Santorelli , et al. (4 additional authors not shown)

    Abstract: The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to discriminate the background (electron recoils) from the WIMP signals (nuclear recoils). After a successful operation on surface at CERN, the detector was recently install… ▽ More

    Submitted 16 September, 2013; originally announced September 2013.

    Comments: 6 pages, 3 figures, Light Detection In Noble Elements (LIDINE 2013)

    Journal ref: JINST 8 (2013) C09005

  2. arXiv:1307.0117  [pdf, other

    physics.ins-det

    Status of the ArDM Experiment: First results from gaseous argon operation in deep underground environment

    Authors: ArDM Collaboration, A. Badertscher, F. Bay, N. Bourgeois, C. Cantini, M. Daniel, U. Degunda, S. DiLuise, L. Epprecht, A. Gendotti, S. Horikawa, L. Knecht, D. Lussi, G. Maire, B. Montes, S. Murphy, G. Natterer, K. Nikolics, K. Nguyen, L. Periale, S. Ravat, F. Resnati, L. Romero, A. Rubbia, R. Santorelli , et al. (4 additional authors not shown)

    Abstract: The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper,… ▽ More

    Submitted 29 June, 2013; originally announced July 2013.

    Comments: 21 pages, 20 figures

  3. arXiv:1206.1181   

    physics.ins-det hep-ex

    Performance of a 250L liquid Argon TPC for sub-GeV charged particle identification

    Authors: J-PARC T32 collaboration, :, O. Araoka, A. Badertscher, A. Curioni, S. Di Luise, U. Degunda, L. Epprecht, L. Esposito, A. Gendotti, T. Hasegawa, S. Horikawa, K. Kasami, N. Kimura, L. Knecht, T. Kobayashi, C. Lazzaro, D. Lussi, M. Maki, A. Marchionni, T. Maruyama, A. Meregaglia, T. Mitani, Y. Nagasaka, J. Naganoma , et al. (17 additional authors not shown)

    Abstract: We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper describes a study of particle identification performance of the detector using well-defined charged particles (pions, kaons, and protons) with momentum of ~800 MeV/$c$ obtained at J-PARC K1.1BR beamline.

    Submitted 8 June, 2012; v1 submitted 6 June, 2012; originally announced June 2012.

    Comments: his paper has been withdrawn by the author due to a crucial problem on the result section

  4. First operation and drift field performance of a large area double phase LAr Electron Multiplier Time Projection Chamber with an immersed Greinacher high-voltage multiplier

    Authors: A. Badertscher, A. Curioni, U. Degunda, L. Epprecht, A. Gendotti, S. Horikawa, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, K. Nguyen, F. Resnati, A. Rubbia, T. Viant

    Abstract: We have operated a liquid-argon large-electron-multiplier time-projection chamber (LAr LEM-TPC) with a large active area of 76 $\times$ 40 cm$^2$ and a drift length of 60 cm. This setup represents the largest chamber ever achieved with this novel detector concept. The chamber is equipped with an immersed built-in cryogenic Greinacher multi-stage high-voltage (HV) multiplier, which, when subjected… ▽ More

    Submitted 12 July, 2012; v1 submitted 16 April, 2012; originally announced April 2012.

    Comments: 26 pages, 19 figures

    Journal ref: 2012 JINST 7 P08026

  5. arXiv:1105.5818  [pdf, other

    physics.ins-det

    A tagged low-momentum kaon test-beam exposure with a 250L LAr TPC (J-PARC T32)

    Authors: O. Araoka, A. Badertscher, A. Curioni, S. DiLuise, U. Degunda, L. Epprecht, L. Esposito, A. Gendotti, T. Hasegawa, S. Horikawa, K. Kasami, N. Kimura, L. Knecht, T. Kobayashi, C. Lazzaro, D. Lussi, M. Maki, A. Marchionni, T. Maruyama, A. Meregaglia, T. Mitani, Y. Nagasaka, J. Naganoma, H. Naito, S. Narita , et al. (13 additional authors not shown)

    Abstract: At the beginning of 2010, we presented at the J-PARC PAC an R$&$D program towards large (100 kton scale) liquid argon TPCs, suitable to investigate, in conjunction with the J-PARC neutrino beam, the possibility of CP violation in the neutrino sector and to search for nucleon decay. As a first step we proposed a test experiment to identify and measure charged kaons, including their decays, in liqui… ▽ More

    Submitted 29 May, 2011; originally announced May 2011.

    Comments: 14 pages, 14 figures, to appear in Proc. of 1st International Workshop towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba (Japan), March 2010

  6. ArDM: a ton-scale LAr detector for direct Dark Matter searches

    Authors: ArDM Collaboration, A. Marchionni, C. Amsler, A. Badertscher, V. Boccone, A. Bueno, M. C. Carmona-Benitez, J. Coleman, W. Creus, A. Curioni, M. Daniel, E. J. Dawe, U. Degunda, A. Gendotti, L. Epprecht, S. Horikawa, L. Kaufmann, L. Knecht, M. Laffranchi, C. Lazzaro, P. K. Lightfoot, D. Lussi, J. Lozano, K. Mavrokoridis, A. Melgarejo , et al. (19 additional authors not shown)

    Abstract: The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduc… ▽ More

    Submitted 29 December, 2010; originally announced December 2010.

    Comments: To appear in Proceedings 1st International Workshop towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba, March 2010

  7. First operation of a double phase LAr Large Electron Multiplier Time Projection Chamber with a two-dimensional projective readout anode

    Authors: A. Badertscher, A. Curioni, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, F. Resnati, A. Rubbia, T. Viant

    Abstract: We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of adjustable charge amplification, a promising readout technology for next-generation neutrino detectors and direct Dark Matter searches. In this… ▽ More

    Submitted 2 December, 2010; originally announced December 2010.

    Comments: 25 pages, 17 figures

  8. Stable operation with gain of a double phase Liquid Argon LEM-TPC with a 1 mm thick segmented LEM

    Authors: A. Badertscher, A. Curioni, S. Horikawa, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, F. Resnati, A. Rubbia, T. Viant

    Abstract: In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification, suited for next-generation neutrino detectors and possibly direct Dark Matter searches. During a test of a 3~lt chamber equipped with a 10$\times$10~cm$^2$ readout,… ▽ More

    Submitted 12 October, 2010; originally announced October 2010.

    Comments: 7 pages, 6 figures, to appear in Proc. of 1st International Workshop towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba (Japan), March 2010

    Journal ref: J.Phys.Conf.Ser.308:012016,2011

  9. Towards a liquid Argon TPC without evacuation: filling of a 6 m^3 vessel with argon gas from air to ppm impurities concentration through flushing

    Authors: A. Curioni, L. Epprecht, A. Gendotti, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, F. Resnati, A. Rubbia, J. Coleman, M. Lewis, K. Mavrokoridis, K. McCormick, C. Touramanis

    Abstract: In this paper we present a successful experimental test of filling a volume of 6 m$^3$ with argon gas, starting from normal ambient air and reducing the impurities content down to few parts per million (ppm) oxygen equivalent. This level of contamination was directly monitored measuring the slow component of the scintillation light of the Ar gas, which is sensitive to {\it all} sources of impuriti… ▽ More

    Submitted 22 September, 2010; v1 submitted 21 September, 2010; originally announced September 2010.

    Comments: 9 pages, 6 figures, to appear in Proc. 1st International Workshop towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba, March 2010

    Journal ref: J.Phys.Conf.Ser.308:012024,2011

  10. First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches

    Authors: C. Amsler, A. Badertscher, V. Boccone, A. Bueno, M. C. Carmona-Benitez, W. Creus, A. Curioni, M. Daniel, E. J. Dawe, U. Degunda, A. Gendotti, L. Epprecht, S. Horikawa, L. Kaufmann, L. Knecht, M. Laffranchi, C. Lazzaro, P. K. Lightfoot, D. Lussi, J. Lozano, A. Marchionni, K. Mavrokoridis, A. Melgarejo, P. Mijakowski, G. Natterer , et al. (16 additional authors not shown)

    Abstract: ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM… ▽ More

    Submitted 27 October, 2010; v1 submitted 19 September, 2010; originally announced September 2010.

    Comments: 14 pages, 10 figures, v2 accepted for publication in JINST

    Journal ref: JINST 5:P11003,2010

  11. arXiv:1006.5335  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    The ArDM experiment

    Authors: ArDM Collaboration, C. Amsler, A. Badertscher, V. Boccone, N. Bourgeois, A. Bueno, M. C. Carmona-Benitez, M. Chorowski, W. Creus, A. Curioni, E. Daw, U. Degunda, A. Dell'Antone, M. Droge, L. Epprecht, C. Haller, M. Haranczyk, S. Horikawa, L. Kaufmann, J. Kisiel, L. Knecht, M. Laffranchi, J. Lagoda, C. Lazzaro, P. Lightfoot , et al. (29 additional authors not shown)

    Abstract: The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, includin… ▽ More

    Submitted 28 June, 2010; originally announced June 2010.

    Comments: Proceedings of the Epiphany 2010 Conference, to be published in Acta Physica Polonica B

    Journal ref: Acta Phys.Polon.B41:1441-1446,2010

  12. arXiv:1001.0076  [pdf, ps, other

    physics.ins-det

    Giant Liquid Argon Observatory for Proton Decay, Neutrino Astrophysics and CP-violation in the Lepton Sector (GLACIER)

    Authors: A. Badertscher, A. Curioni, U. Degunda, L. Epprecht, S. Horikawa, L. Knecht, C. Lazzaro, D. Lussi, A. Marchionni, G. Natterer, P. Otiougova, F. Resnati, A. Rubbia, C. Strabel, J. Ulbricht, T. Viant

    Abstract: GLACIER (Giant Liquid Argon Charge Imaging ExpeRiment) is a large underground observatory for proton decay search, neutrino astrophysics and CP-violation studies in the lepton sector. Possible underground sites are studied within the FP7 LAGUNA project (Europe) and along the JPARC neutrino beam in collaboration with KEK (Japan). The concept is scalable to very large masses.

    Submitted 30 December, 2009; originally announced January 2010.

    Comments: 4 pages, 1 figure, Contribution to the Workshop "European Strategy for Future Neutrino Physics", CERN, Oct. 2009

  13. Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: comparison of single and double phase operation

    Authors: A. Badertscher, L. Knecht, M. Laffranchi, D. Lussi, A. Marchionni, G. Natterer, P. Otiougova, F. Resnati, A. Rubbia, T. Viant

    Abstract: We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM w… ▽ More

    Submitted 16 July, 2009; originally announced July 2009.

    Comments: 4 pages, 5 figures, Based on a talk given at the 11th Pisa meeting on advanced detectors - Isola d'Elba 26 May 2009

  14. Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector

    Authors: The ArDM Collaboration, V. Boccone, P. K. Lightfoot, K. Mavrokoridis, C. Regenfus, C. Amsler, A. Badertscher, A. Bueno, H. Cabrera, M. C. Carmona-Benitez, M. Daniel, E. J. Daw, U. Degunda, A. Dell'Antone, A. Gendotti, L. Epprecht, S. Horikawa, L. Kaufmann, L. Knecht, M. Laffranchi, C. Lazzaro, D. Lussi, J. Lozano, A. Marchionni, A. Melgarejo , et al. (16 additional authors not shown)

    Abstract: To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were… ▽ More

    Submitted 1 April, 2009; originally announced April 2009.

    Comments: 21 pages, 17 figures

    Journal ref: JINST 4:P06001,2009