-
Design and Test of Wire-Scanners for SwissFEL
Authors:
G. L. Orlandi,
M. Baldinger,
H. Brands,
P. Heimgartner,
R. Ischebeck,
A. Kammerer,
F. Löhl,
R. Lüscher,
P. Mohanmurthy,
C. Ozkan,
V. Schlott,
L. Schulz,
B. Rippstein,
C. Seiler,
S. Trovati,
P. Valitutti,
D. Zimoch
Abstract:
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam tra…
▽ More
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam transverse profile without suffering from possible micro-bunching of the electron beam. The main aspects of the design, laboratory characterization and beam-test of the SwissFEL wire-scanner prototype will be discussed.
△ Less
Submitted 1 November, 2016;
originally announced November 2016.
-
Target Studies for Surface Muon Production
Authors:
F. Berg,
L. Desorgher,
A. Fuchs,
W. Hajdas,
Z. Hodge,
P. -R. Kettle,
A. Knecht,
R. Lüscher,
A. Papa,
G. Rutar,
M. Wohlmuther
Abstract:
Meson factories are powerful drivers of diverse physics programmes. With beam powers already in the MW-regime attention has to be turned to target and beam line design to further significantly increase surface muon rates available for experiments. For this reason we have explored the possibility of using a neutron spallation target as a source of surface muons by performing detailed Geant4 simulat…
▽ More
Meson factories are powerful drivers of diverse physics programmes. With beam powers already in the MW-regime attention has to be turned to target and beam line design to further significantly increase surface muon rates available for experiments. For this reason we have explored the possibility of using a neutron spallation target as a source of surface muons by performing detailed Geant4 simulations with pion production cross sections based on a parametrization of existing data. While the spallation target outperforms standard targets in the backward direction by more than a factor 7 it is not more efficient than standard targets viewed under 90°. Not surprisingly, the geometry of the target plays a large role in the generation of surface muons. Through careful optimization, a gain in surface muon rate of between 30 - 60% over the standard "box-like" target used at the Paul Scherrer Institute could be achieved by employing a rotated slab target. An additional 10% gain could also be possible by utilizing novel target materials such as, e.g., boron carbide.
△ Less
Submitted 23 February, 2016; v1 submitted 4 November, 2015;
originally announced November 2015.
-
Measurement and simulation of the muon-induced neutron yield in lead
Authors:
L. Reichhart,
A. Lindote,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy
, et al. (14 additional authors not shown)
Abstract:
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well…
▽ More
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well the measured capture times and multiplicities and, within the dynamic range of the instrumentation, the spectrum of energy deposits. By comparing measurements with simulations of neutron capture rates a neutron yield in lead of (5.78^{+0.21}_{-0.28}) x 10^{-3} neutrons/muon/(g/cm^{2}) has been obtained. Absolute agreement between simulation and data is of order 25%. Consequences for deep underground rare event searches are discussed.
△ Less
Submitted 4 November, 2013; v1 submitted 18 February, 2013;
originally announced February 2013.
-
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Authors:
V. N. Solovov,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (11 additional authors not shown)
Abstract:
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the…
▽ More
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
△ Less
Submitted 26 September, 2012; v1 submitted 7 December, 2011;
originally announced December 2011.
-
Performance data from the ZEPLIN-III second science run
Authors:
P. Majewski,
V. N. Solovov,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (10 additional authors not shown)
Abstract:
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the…
▽ More
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the instrument performance with emphasis on the position and energy reconstruction algorithm and summarise the final science results.
△ Less
Submitted 30 November, 2011;
originally announced December 2011.
-
Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator
Authors:
L. Reichhart,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling
, et al. (12 additional authors not shown)
Abstract:
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (…
▽ More
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (UPS-923A) is presented, exploring recoil energies between 125 keV and 850 keV. Monte Carlo simulations, incorporating light collection efficiency and energy resolution effects, are used to generate neutron scattering spectra which are matched to observed distributions of scintillation signals to parameterise the energy-dependent quenching factor. At energies above 300 keV the dependence is reasonably described using the semi-empirical formulation of Birks and a kB factor of (0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured quenching factor falls more steeply than predicted by the Birks formalism.
△ Less
Submitted 9 November, 2011;
originally announced November 2011.
-
WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling
, et al. (12 additional authors not shown)
Abstract:
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 ke…
▽ More
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 keV, which is compatible with background expectations. This allows the exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass with 90% confidence. Combined with data from the first run, this result improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its conclusion at Boulby, having deployed and exploited successfully three liquid xenon experiments of increasing reach.
△ Less
Submitted 16 December, 2011; v1 submitted 21 October, 2011;
originally announced October 2011.
-
Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
Authors:
E. Santos,
B. Edwards,
V. Chepel,
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
L. DeViveiros,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these…
▽ More
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of $\sim$3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Authors:
F. Neves,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. Preece
, et al. (12 additional authors not shown)
Abstract:
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d…
▽ More
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.
△ Less
Submitted 4 June, 2011;
originally announced June 2011.
-
Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
Authors:
M. Horn,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
C. Ghag,
A. Hollingsworth,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (11 additional authors not shown)
Abstract:
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r…
▽ More
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is found, together with a rising ionisation yield; both are in good agreement with the latest independent measurements. The analysis method is applied to both the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
△ Less
Submitted 17 October, 2011; v1 submitted 3 June, 2011;
originally announced June 2011.
-
Radioactivity Backgrounds in ZEPLIN-III
Authors:
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel. A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy. F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (10 additional authors not shown)
Abstract:
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level…
▽ More
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05$\pm$0.5 nuclear recoils with energy 5-50 keV per year, which translates to an expectation of 0.4 events in a 1-year dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from $β$ activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter $γ$-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of $\sim 1 \times 10^{-8}$ pb$\cdot$year to the scalar WIMP-nucleon elastic cross-section, as originally conceived.
△ Less
Submitted 12 August, 2011; v1 submitted 18 April, 2011;
originally announced April 2011.
-
Performance of the veto detector incorporated into the ZEPLIN-III experiment
Authors:
C. Ghag,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
K. Lyons,
P. Majewski,
A. St,
J. Murphy,
F. Neves
, et al. (14 additional authors not shown)
Abstract:
The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of…
▽ More
The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of operation in coincidence with ZEPLIN-III are presented. With fully automated operation and calibration, the veto system has maintained high stability and achieves near unity live time relative to ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60% of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be misidentified as WIMPs. This tagging efficiency reduces the expected untagged nuclear recoil background from neutrons during science data taking to a very low rate of ~0.2 events per year in the WIMP acceptance region. Additionally, the veto detector provides rejection of 28% of gamma-ray induced background events, allowing the sampling of the dominant source of background in ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will not be tagged by the veto detector, and tags due to gamma-rays and neutrons are separable, this population of multiple scatter events may be characterised without biasing the analysis of candidate WIMP signals in the data.
△ Less
Submitted 1 May, 2011; v1 submitted 2 March, 2011;
originally announced March 2011.
-
The ZEPLIN-III Anti-Coincidence Veto Detector
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim…
▽ More
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim has been to achieve a veto detector of low threshold and high efficiency without the creation of additional background in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of the components have been made, including radioactivity levels and performance characteristics. These have been used to inform a complete end-to-end Monte Carlo simulation that has then been used to calculate the expected performance of the new instrument, both operating alone and as an anti-coincidence detector for ZEPLIN-III. The veto device will be capable of rejecting over 65% of coincident nuclear recoil events from neutron background in the energy range of interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4 to ~0.14 events per year in the WIMP acceptance region, a significant factor in the event of a non-zero observation. Furthermore, in addition to providing valuable diagnostic capabilities, the veto is capable of tagging over 15% for gamma-ray rejection, all whilst contributing no significant additional background. In conjunction with the replacement of the internal ZEPLIN-III photomultiplier array, the new veto is expected to improve significantly the sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
△ Less
Submitted 27 April, 2010; v1 submitted 23 April, 2010;
originally announced April 2010.
-
Limits on inelastic dark matter from ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
R. Cashmore,
V. Chepel,
A. Currie,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
I. Liubarsky
, et al. (21 additional authors not shown)
Abstract:
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under…
▽ More
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under standard halo assumptions a small region of parameter space consistent, at 99% CL, with causing the 1.17 ton.year DAMA modulation signal is allowed at 90% CL: it is in the mass range 45-60 GeV with a minimum CL of 88%, again derived from the maximum patch. This is the tightest constraint on that explanation of the DAMA result yet presented using a xenon target.
△ Less
Submitted 1 April, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
Calibration of Photomultiplier Arrays
Authors:
F. Neves,
V. Chepel,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
B. Edwards,
C. Ghag,
M. Horn,
A. J. Hughes,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (9 additional authors not shown)
Abstract:
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields,…
▽ More
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields, etc) are exactly matched between calibration and science acquisitions. This is of particular importance in low background experiments such as ZEPLIN-III, where methods involving the use of external light sources for calibration are severely constrained.
△ Less
Submitted 15 May, 2009;
originally announced May 2009.
-
Limits on the spin-dependent WIMP-nucleon cross-sections from the first science run of the ZEPLIN-III experiment
Authors:
V. N. Lebedenko,
H. M. Araujo,
E. J. Barnes,
A. Bewick,
R. Cashmore,
V. Chepel,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
V. Graffagnino,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
M. Joshi,
G. E. Kalmus,
A. G. Kovalenko,
A. Lindote,
I. Liubarsky,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski
, et al. (14 additional authors not shown)
Abstract:
We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross-sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter WIMPs based at the Boulby mine. Analysis of $\sim$450 kg$\cdot$days fiducial exposure revealed a most likely signal of zero events, leading to a 90%-confidence upper limit on the pure…
▽ More
We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross-sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter WIMPs based at the Boulby mine. Analysis of $\sim$450 kg$\cdot$days fiducial exposure revealed a most likely signal of zero events, leading to a 90%-confidence upper limit on the pure WIMP-neutron cross-section of $σ_n=1.8\times 10^{-2}$ pb at 55 GeV/$c^2$ WIMP mass. Recent calculations of the nuclear spin structure based on the Bonn CD nucleon-nucleon potential were used for the odd-neutron isotopes $^{129}$Xe and $^{131}$Xe. These indicate that the sensitivity of xenon targets to the spin-dependent WIMP-proton interaction is much lower than implied by previous calculations, whereas the WIMP-neutron sensitivity is impaired only by a factor of $\sim$2.
△ Less
Submitted 27 January, 2009;
originally announced January 2009.
-
Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
Authors:
V. N. Lebedenko,
H. M. Araujo,
E. J. Barnes,
A. Bewick,
R. Cashmore,
V. Chepel,
A. Currie,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
M. Joshi,
G. E. Kalmus,
A. G. Kovalenko,
A. Lindote,
I. Liubarsky,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy
, et al. (13 additional authors not shown)
Abstract:
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected…
▽ More
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected from WIMPs and the electron recoil background signals down to ~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon elastic scattering spin-independent cross-section above 8.1x10(-8)pb at 55GeV/c2 with a 90% confidence limit. It has also demonstrated that the two-phase xenon technique is capable of better discrimination between electron and nuclear recoils at low-energy than previously achieved by other xenon-based experiments.
△ Less
Submitted 2 September, 2009; v1 submitted 5 December, 2008;
originally announced December 2008.
-
Measurements of neutrons produced by high-energy muons at the Boulby Underground Laboratory
Authors:
H. M. Araujo,
J. Blockley,
C. Bungau,
M. J. Carson,
H. Chagani,
E. Daw,
B. Edwards,
C. Ghag,
E. V. Korolkova,
V. A. Kudryavtsev,
P. K. Lightfoot,
A. Lindote,
I. Liubarsky,
R. Luscher,
P. Majewski,
K. Mavrokoridis,
J. E. McMillan,
A. St. J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. M. Preece,
M. Robinson,
N. J. T. Smith,
P. F. Smith,
N. J. C. Spooner
, et al. (4 additional authors not shown)
Abstract:
We present the first measurements of the muon-induced neutron flux at the Boulby Underground Laboratory. The experiment was carried out with an 0.73 tonne liquid scintillator that also served as an anticoincidence system for the ZEPLIN-II direct dark matter search. The experimental method exploited the delayed coincidences between high-energy muon signals and gamma-rays from radiative neutron ca…
▽ More
We present the first measurements of the muon-induced neutron flux at the Boulby Underground Laboratory. The experiment was carried out with an 0.73 tonne liquid scintillator that also served as an anticoincidence system for the ZEPLIN-II direct dark matter search. The experimental method exploited the delayed coincidences between high-energy muon signals and gamma-rays from radiative neutron capture on hydrogen or other elements. The muon-induced neutron rate, defined as the average number of detected neutrons per detected muon, was measured as $0.079 \pm 0.003$ (stat.) neutrons/muon using neutron-capture signals above 0.55 MeV in a time window of 40-190 $μ$s after the muon trigger. Accurate Monte Carlo simulations of the neutron production, transport and detection in a precisely modeled laboratory and experimental setup using the GEANT4 toolkit gave a result 1.8 times higher than the measured value. The difference greatly exceeds all statistical and systematic uncertainties. As the vast majority of neutrons detected in the current setup were produced in lead we evaluated from our measurements the neutron yield in lead as $(1.31 \pm 0.06) \times 10^{-3}$ neutrons/muon/(g/cm$^2$) for a mean muon energy of about 260 GeV.
△ Less
Submitted 20 May, 2008;
originally announced May 2008.
-
Measurement of single electron emission in two-phase xenon
Authors:
B. Edwards,
H. M. Araujo,
V. Chepel,
D. Cline,
T. Durkin,
J. Gao,
C. Ghag,
E. V. Korolkova,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St. J. Murphy,
F. Neves,
W. Ooi,
J. Pinto da Cunha,
R. M. Preece,
G. Salinas,
C. Silva,
V. N. Solovov,
N. J. T. Smith,
P. F. Smith,
T. J. Sumner,
C. Thorne,
R. J. Walker
, et al. (3 additional authors not shown)
Abstract:
We present the first measurements of the electroluminescence response to the emission of single electrons in a two-phase noble gas detector. Single ionization electrons generated in liquid xenon are detected in a thin gas layer during the 31-day background run of the ZEPLIN-II experiment, a two-phase xenon detector for WIMP dark matter searches. Both the pressure dependence and magnitude of the…
▽ More
We present the first measurements of the electroluminescence response to the emission of single electrons in a two-phase noble gas detector. Single ionization electrons generated in liquid xenon are detected in a thin gas layer during the 31-day background run of the ZEPLIN-II experiment, a two-phase xenon detector for WIMP dark matter searches. Both the pressure dependence and magnitude of the single-electron response are in agreement with previous measurements of electroluminescence yield in xenon. We discuss different photoionization processes as possible cause for the sample of single electrons studied in this work. This observation may have implications for the design and operation of future large-scale two-phase systems.
△ Less
Submitted 6 August, 2007;
originally announced August 2007.
-
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
Authors:
G. J. Alner,
H. M. Araujo,
A. Bewick,
C. Bungau,
B. Camanzi,
M. J. Carson,
R. J. Cashmore,
H. Chagani,
V. Chepel,
D. Cline,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
J. Gao,
C. Ghag,
A. S. Howard,
W. G. Jones,
M. Joshi,
E. V. Korolkova,
V. A. Kudryavtsev,
T. Lawson
, et al. (36 additional authors not shown)
Abstract:
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ra…
▽ More
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
△ Less
Submitted 31 January, 2007; v1 submitted 30 January, 2007;
originally announced January 2007.
-
The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
Authors:
D. Yu. Akimov,
G. J. Alner,
H. M. Araujo,
A. Bewick,
C. Bungau,
A. A. Burenkov,
M. J. Carson,
V. Chepel,
D. Cline,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
C. Chag,
R. J. Hollingworth,
A. S. Howard,
W. G. Jones,
M. Joshi,
J. Kirkpatrick,
A. Kovalenko,
V. A. Kudryavtsev,
I. S. Kuznetsov
, et al. (35 additional authors not shown)
Abstract:
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of…
▽ More
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
△ Less
Submitted 19 May, 2006;
originally announced May 2006.
-
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
Authors:
H. M. Araujo,
D. Yu. Akimov,
G. J. Alner,
A. Bewick,
C. Bungau,
B. Camanzi,
M. J. Carson,
V. Chepel,
H. Chagani,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
C. Ghag,
R. Hollingworth,
A. S. Howard,
W. G. Jones,
M. Joshi,
J. Kirkpatrick,
A. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko
, et al. (31 additional authors not shown)
Abstract:
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, includ…
▽ More
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.
△ Less
Submitted 9 March, 2006;
originally announced March 2006.
-
Measurements of muon flux at 1070 metres vertical depth in the Boulby underground laboratory
Authors:
M. Robinson,
V. A. Kudryavtsev,
R. Luscher,
J. E. McMillan,
P. K. Lightfoot,
N. J. C. Spooner,
N. J. T. Smith,
I. Liubarsky
Abstract:
Measurements of cosmic-ray muon rates and energy deposition spectra in a one tonne liquid scintillator detector at 1070 metres vertical depth in the Boulby underground laboratory are discussed. In addition, the simulations used to model the detector are described. The results of the simulations are compared to the experimental data and conclusions given. The muon flux in the laboratory is found…
▽ More
Measurements of cosmic-ray muon rates and energy deposition spectra in a one tonne liquid scintillator detector at 1070 metres vertical depth in the Boulby underground laboratory are discussed. In addition, the simulations used to model the detector are described. The results of the simulations are compared to the experimental data and conclusions given. The muon flux in the laboratory is found to be (4.09+/-0.15)x10^-8 /cm^2/s.
△ Less
Submitted 4 June, 2003;
originally announced June 2003.
-
Dark Matter at Boulby Mine
Authors:
R. Luscher
Abstract:
The Boulby Dark Matter Collaboration (BDMC) is running a WIMP Dark Matter research programme in the underground laboratory of Boulby Mine. The two axes of the programme are based on (1) liquid Xenon (LXe) as the WIMP target and (2) directional detection in low pressure gas detectors. ZEPLIN-1 is a 3.1kg of LXe scintillation detector with a background discrimination based on Pulse Shape Analysis.…
▽ More
The Boulby Dark Matter Collaboration (BDMC) is running a WIMP Dark Matter research programme in the underground laboratory of Boulby Mine. The two axes of the programme are based on (1) liquid Xenon (LXe) as the WIMP target and (2) directional detection in low pressure gas detectors. ZEPLIN-1 is a 3.1kg of LXe scintillation detector with a background discrimination based on Pulse Shape Analysis. A new limit from a preliminary analysis is presented. Further generation setups with improved background discrimination tools (as the ionisation is also recorded) are in construction. ZEPLIN-2 and ZEPLIN-3, are predicted to be sensitive to rate of 0.1-0.01 events/kg/day within 2 years of data, with fiducial masses of 30kg and 6kg, respectively. These are important steps towards the design of a tonne-scale LXe Dark Matter detector array. The DRIFT programme relies on discrimination by tracking and directionnal detection. This enables the measurement of any sidereal modulation, as the earth's rotation changes the flux angle of Galactic WIMPs. A low pressure 1m$^3$ chamber (DRIFT-1) is currently taking data underground. A setup for a bigger volume with increased spatial resolution (enabling the pressure, and hence the target mass to be increase) is in the designing process.
△ Less
Submitted 16 May, 2003;
originally announced May 2003.
-
The NAIAD experiment for WIMP searches at Boulby mine and recent results
Authors:
B. Ahmed,
G. J. Alner,
H. Araujo,
J. C. Barton,
A. Bewick,
M. J. Carson,
D. Davidge,
J. V. Dawson,
T. Gamble,
S. P. Hart,
R. Hollingworth,
A. S. Howard,
W. G. Jones,
M. K. Joshi,
V. A. Kudryavtsev,
T. B. Lawson,
V. Lebedenko,
M. J. Lehner,
J. D. Lewin,
P. K. Lightfoot,
I. Liubarsky,
R. Luscher,
J. E. McMillan,
B. Morgan,
G. Nicklin
, et al. (10 additional authors not shown)
Abstract:
The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and…
▽ More
The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and WIMP-proton spin-dependent cross-sections. Pulse shape analysis has been applied to discriminate between nuclear recoils, as may be caused by WIMP interactions, and electron recoils due to gamma background. Various calibrations of crystals are presented.
△ Less
Submitted 31 January, 2003;
originally announced January 2003.
-
Neutron background at Boulby mine
Authors:
V. A. Kudryavtsev,
P. K. Lightfoot,
J. E. McMillan,
M. Robinson,
N. J. C. Spooner,
P. F. Smith,
N. J. T. Smith,
J. D. Lewin,
R. Luscher,
I. Liubarsky
Abstract:
The neutron background at the underground laboratory at Boulby - a site for several dark matter experiments - is discussed. Special emphasis is put on the neutron background produced by cosmic-ray muons. The most recent versions of the muon propagation code MUSIC, and particle transport code FLUKA are used to evaluate muon and neutron fluxes. The results of simulations are compared with experime…
▽ More
The neutron background at the underground laboratory at Boulby - a site for several dark matter experiments - is discussed. Special emphasis is put on the neutron background produced by cosmic-ray muons. The most recent versions of the muon propagation code MUSIC, and particle transport code FLUKA are used to evaluate muon and neutron fluxes. The results of simulations are compared with experimental data.
△ Less
Submitted 31 January, 2003;
originally announced January 2003.
-
Study and suppression of anomalous fast events in inorganic scintillators for dark matter searches
Authors:
V. A. Kudryavtsev,
N. J. C. Spooner,
P. K. Lightfoot,
J. W. Roberts,
M. J. Lehner,
T. Gamble,
M. J. Carson,
T. B. Lawson,
R. Luscher,
J. E. McMillan,
B. Morgan,
S. M. Paling,
M. Robinson,
D. R. Tovey,
N. J. T. Smith,
P. F. Smith,
G. J. Alner,
S. P. Hart,
J. D. Lewin,
R. M. Preece,
T. J. Sumner,
W. G. Jones,
J. J. Quenby,
B. Ahmed,
A. Bewick
, et al. (12 additional authors not shown)
Abstract:
The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystal…
▽ More
The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystals by alphas, probably from radon decay. A new array of unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure nitrogen atmosphere is under construction at Boulby. Such an approach allows complete control of the surface of the crystals and the ability to remove any surface contamination. First data from the unencapsulated NaI(Tl) do not show the presence of anomalous fast events.
△ Less
Submitted 12 September, 2001;
originally announced September 2001.
-
Sub MeV Particles Detection and Identification in the MUNU detector ((1)ISN, IN2P3/CNRS-UJF, Grenoble, France, (2)Institut de Physique, Neuchâtel, Switzerland, (3) INFN, Padova Italy, (4) Physik-Institut, Zürich, Switzerland)
Authors:
M. Avenier,
C. Broggini,
J. Busto,
C. Cerna,
V. Chazal,
P. Jeanneret,
G. Jonkmans,
D. H. Koang,
J. Lamblin,
D. Lebrun,
O. Link,
R. Lüescher,
F. Ouldsada,
G. Puglierin,
A. Stutz,
A. Tadsen,
J. -L. Vuilleumier
Abstract:
We report on the performance of a 1 m$^{3}$ TPC filled with CF$_{4}$ at 3 bar, immersed in liquid scintillator and viewed by photomultipliers. Particle detection, event identification and localization achieved by measuring both the current signal and the scintillation light are presented. Particular features of $α$ particle detection are also discussed. Finally, the ${54}$Mn photopeak, reconstru…
▽ More
We report on the performance of a 1 m$^{3}$ TPC filled with CF$_{4}$ at 3 bar, immersed in liquid scintillator and viewed by photomultipliers. Particle detection, event identification and localization achieved by measuring both the current signal and the scintillation light are presented. Particular features of $α$ particle detection are also discussed. Finally, the ${54}$Mn photopeak, reconstructed from the Compton scattering and recoil angle is shown.
△ Less
Submitted 17 July, 2001; v1 submitted 29 June, 2001;
originally announced June 2001.
-
Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
Authors:
D. Akimov,
A. Bewick,
D. Davidge,
J. Dawson,
A. S. Howard,
I. Ivaniouchenkov,
W. G. Jones,
M. Joshi,
V. A. Kudryavtsev,
T. B. Lawson,
V. Lebedenko,
M. J. Lehner,
P. K. Lightfoot,
I. Liubarsky,
R. Luscher,
J. E. McMillan,
C. D. Peak,
J. J. Quenby,
N. J. C. Spooner,
T. J. Sumner,
D. R. Tovey,
C. K. Ward
Abstract:
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estima…
▽ More
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator of the decay time constant for 6 keV < Eee < 30 keV nuclear recoil events is equal to 21.0 ns +/- 0.5 ns. It is observed that for electron recoils T0 rises slowly with energy, having a value ~ 30 ns at Eee ~ 15 keV. Electron and nuclear recoil pulse-shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse-shape.
△ Less
Submitted 8 June, 2001;
originally announced June 2001.
-
CsI(Tl) for WIMP dark matter searches
Authors:
V. A. Kudryavtsev,
N. J. C. Spooner,
D. R. Tovey,
J. W. Roberts,
M. J. Lehner,
J. E. McMillan,
P. K. Lightfoot,
T. B. Lawson,
C. D. Peak,
R. Luscher,
J. C. Barton
Abstract:
We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find that, as with NaI(Tl), pulse shape analysis can be used to discriminate between electron and nuclear recoils down to 4 keV. However, the discrimination factor…
▽ More
We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find that, as with NaI(Tl), pulse shape analysis can be used to discriminate between electron and nuclear recoils down to 4 keV. However, the discrimination factor is typically (10-15)% better than in NaI(Tl) above 4 keV. The quenching factor for caesium and iodine recoils was measured and found to increase from 11% to ~17% with decreasing recoil energy from 60 to 12 keV. Based on these results, the potential sensitivity of CsI(Tl) to dark matter particles in the form of neutralinos was calculated. We find an improvement over NaI(Tl) for the spin independent WIMP-nucleon interactions up to a factor of 5 assuming comparable electron background levels in the two scintillators.
△ Less
Submitted 22 May, 2000;
originally announced May 2000.