Skip to main content

Showing 1–7 of 7 results for author: Lupu, N

.
  1. arXiv:2303.12571  [pdf, other

    hep-ex physics.ins-det

    The New Small Wheel electronics

    Authors: G. Iakovidis, L. Levinson, Y. Afik, C. Alexa, T. Alexopoulos, J. Ameel, D. Amidei, D. Antrim, A. Badea, C. Bakalis, H. Boterenbrood, R. S. Brener, S. Chan, J. Chapman, G. Chatzianastasiou, H. Chen, M. C. Chu, R. M. Coliban, T. Costa de Paiva, G. de Geronimo, R. Edgar, N. Felt, S. Francescato, M. Franklin, T. Geralis , et al. (77 additional authors not shown)

    Abstract: The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector te… ▽ More

    Submitted 25 May, 2023; v1 submitted 22 March, 2023; originally announced March 2023.

    Comments: 61 pages

    Journal ref: JINST 18 P05012 (2023)

  2. arXiv:2212.03110  [pdf, other

    physics.ins-det hep-ex

    High Rate Studies of the ATLAS sTGC Detector and Optimization of the Filter Circuit on the Input of the Front-End Amplifier

    Authors: Siyuan Sun, Luca Moleri, Gerardo Vasquez, Peter Teterin, Sabrina Corsetti, Liang Guan, Benoit Lefebvre, Enrique Kajomovitz, Lorne Levinson, Nachman Lupu, Rob McPherson, Alexander Vdovin, Rongkun Wang, Bing Zhou, Junjie Zhu

    Abstract: The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5 - 7.5 $\times$ 10$^{34}$cm$^{-2}$ s$^{-1}$. This represents a more than 3-4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficien… ▽ More

    Submitted 17 April, 2023; v1 submitted 6 December, 2022; originally announced December 2022.

    Comments: to be submitted

  3. arXiv:2104.11012  [pdf, other

    physics.ins-det hep-ex

    A detector-emulation method for realistic readout-electronics tests. A case study of VMM3a ASIC for sTGC detector

    Authors: Luca Moleri, Nachman Lupu, Alexander Vdovin, Enrique Kajomovitz

    Abstract: A detector emulator method has been developed. It allows for testing any readout electronics with realistic detector-like signals under controlled conditions, beyond the limits of any experiment based on radiation sources. It can substitute for expensive test-beam campaigns, or predict their results. The detector emulator is a powerful tool for the engineering of detector concepts, with its capabi… ▽ More

    Submitted 6 February, 2022; v1 submitted 22 April, 2021; originally announced April 2021.

  4. arXiv:1702.04807  [pdf

    cond-mat.mtrl-sci

    Synthesis and Hydrogen Sorption Characteristics of Mechanically Alloyed Mg(NixMn1-x)2 Intermetallics

    Authors: Evangelos I Gkanas, Martin Khzouz, Alina Donac, Alexandra Ioannidou, George Stoian, Nicoleta Lupu, Margaritis Gjoka, Sofoklis S Makridis

    Abstract: New ternary Mg-Ni-Mn intermetallics have been successfully synthesized by High Energy Ball Milling (HEBM) and have been studied as possible materials for efficient hydrogen storage applications. The microstructures of the as-cast and milled alloys were characterized by means of X-ray Powder Diffraction (XRD) and Scanning Electron Microscopy (SEM) both prior and after the hydrogenation process, whi… ▽ More

    Submitted 15 February, 2017; originally announced February 2017.

    Comments: Materials Today Energy, 2019

  5. arXiv:1509.06329  [pdf, other

    physics.ins-det hep-ex

    Performance of a Full-Size Small-Strip Thin Gap Chamber Prototype for the ATLAS New Small Wheel Muon Upgrade

    Authors: Angel Abusleme, Camille Bélanger-Champagne, Alain Bellerive, Yan Benhammou, James Botte, Hadar Cohen, Merlin Davies, Yanyan Du, Lea Gauthier, Thomas Koffas, Serguei Kuleshov, Benoit Lefebvre, Changyu Li, Nachman Lupu, Giora Mikenberg, Daniel Mori, Jean-Pierre Ochoa-Ricoux, Estel Perez Codina, Sebastien Rettie, Andree Robichaud-Véronneau, Rimsky Rojas, Meir Shoa, Vladimir Smakhtin, Bernd Stelzer, Oliver Stelzer-Chilton , et al. (10 additional authors not shown)

    Abstract: The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs… ▽ More

    Submitted 21 September, 2015; originally announced September 2015.

    Comments: 10 pages, 16 figures

  6. arXiv:1303.5112  [pdf

    cond-mat.mtrl-sci

    Structure, microstructure and hydrogen storage properties of melt-spun V55Ti21Cr17Fe7 and V55Ti21Mn17Fe7

    Authors: A. Ioannidou, S. S. Makridis, M. Gjoka, E. I. Gkanas, A. K. Stubos, N. Lupu, D. Niarchos

    Abstract: The hydrogen sorption performance of V55Ti21Cr17Fe7 and V55Ti21Mn17Fe7 alloys and their ribbons were evaluated by pressure composition temperature tests. Their hydrogen absorption kinetic properties were studied through hydrogen absorption curves. The crystallographic structures and microstructure of these alloys and ribbons before hydrogen absorption and after hydrogen desorption PCT tests were i… ▽ More

    Submitted 20 March, 2013; originally announced March 2013.

    Comments: Hydrogen Storage, Metal hydrides, Composites

  7. arXiv:1006.0135  [pdf, ps, other

    physics.ins-det hep-ex

    Position resolution and efficiency measurements with large scale Thin Gap Chambers for the super LHC

    Authors: Nir Amram, Gideon Bella, Yan Benhammou, Marco A. Diaz, Ehud Duchovni, Erez Etzion, Alon Hershenhorn, Amit Klier, Nachman Lupu, Giora Mikenberg, Dmitry Milstein, Yonathan Munwes, Osamu Sasaki, Meir Shoa, Vladimir Smakhtin, Ulrich Volkmann

    Abstract: New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strip… ▽ More

    Submitted 2 June, 2010; v1 submitted 1 June, 2010; originally announced June 2010.

    Comments: Presented at the 12 Vienna conference on Instrumentation, February 2010

    Journal ref: Nucl.Instrum.Meth.A628:177-181,2011