-
Model-based Design Tool for Cyber-physical Power Systems using SystemC-AMS
Authors:
Rahul Bhadani,
Satyaki Banik,
Hao Tu,
Srdjan Lukic,
Gabor Karsai
Abstract:
Cyber-physical power systems, such as grids, integrate computational and communication components with physical systems to introduce novel functions and improve resilience and fault tolerance. These systems employ computational components and real-time controllers to meet power demands. Microgrids, comprising interconnected components, energy resources within defined electrical boundaries, computa…
▽ More
Cyber-physical power systems, such as grids, integrate computational and communication components with physical systems to introduce novel functions and improve resilience and fault tolerance. These systems employ computational components and real-time controllers to meet power demands. Microgrids, comprising interconnected components, energy resources within defined electrical boundaries, computational elements, and controllers, offer a solution for integrating renewable energy sources and ensuring resilience in electricity demand. Simulating these cyber-physical systems (CPS) is vital for grid design, as it facilitates the modeling and control of both continuous physical processes and discrete-time power converters and controllers. This paper presents a model-based design tool for simulating cyber-physical power systems, including microgrids, using SystemC-AMS. The adoption of SystemC-AMS enables physical modeling with both native components from the SystemC-AMS library and user-defined computational elements. We observe that SystemC-AMS can accurately produce the electromagnetic transient responses essential for analyzing grid stability. Additionally, we demonstrate the effectiveness of SystemC-AMS through use cases that simulate grid-following inverters. Comparing the SystemC-AMS implementation to one in Simulink reveals that SystemC-AMS offers a more rapid simulation. A design tool like this could support microgrid designers in making informed decisions about the selection of microgrid components prior to installation and deployment.
△ Less
Submitted 14 May, 2024;
originally announced June 2024.
-
Impact of Virtual Inertia on DC Grid Stability with Constant Power Loads
Authors:
Hao Tu,
Hui Yu,
Srdjan Lukic
Abstract:
Virtual inertia is an effective control approach to attenuate sudden voltage changes during transient events in low-inertia DC grids. While methods have been proposed to implement virtual inertia, its impact on DC grid stability in the presence of constant power loads (CPLs) remains unclear. In this paper, we perform a rigorous stability analysis for DC grids with CPLs powered by virtual-inertia-e…
▽ More
Virtual inertia is an effective control approach to attenuate sudden voltage changes during transient events in low-inertia DC grids. While methods have been proposed to implement virtual inertia, its impact on DC grid stability in the presence of constant power loads (CPLs) remains unclear. In this paper, we perform a rigorous stability analysis for DC grids with CPLs powered by virtual-inertia-enhanced converters. We derive a closed-form stability criterion that can be used to evaluate the impact of virtual inertia on the system stability, and demonstrate that, given a set of system parameters, the stability of a DC grid powering CPLs can be improved for a range of virtual inertia designs. We provide analytical expressions for the optimal virtual inertia that improves stability and for the maximum virtual inertia that does not deteriorate stability. In addition, we present a step-by-step guideline to design a stable DC grid with virtual inertia. Test results are presented to validate the analysis.
△ Less
Submitted 7 February, 2023; v1 submitted 8 November, 2022;
originally announced November 2022.
-
An Automated Deployment and Testing Framework for Resilient Distributed Smart Grid Applications
Authors:
Purboday Ghosh,
Hao Tu,
Timothy Krentz,
Gabor Karsai,
Srdjan Lukic
Abstract:
Executing distributed cyber-physical software processes on edge devices that maintains the resiliency of the overall system while adhering to resource constraints is quite a challenging trade-off to consider for developers. Current approaches do not solve this problem of deploying software components to devices in a way that satisfies different resilience requirements that can be encoded by develo…
▽ More
Executing distributed cyber-physical software processes on edge devices that maintains the resiliency of the overall system while adhering to resource constraints is quite a challenging trade-off to consider for developers. Current approaches do not solve this problem of deploying software components to devices in a way that satisfies different resilience requirements that can be encoded by developers at design time. This paper introduces a resilient deployment framework that can achieve that by accepting user-defined constraints to optimize redundancy or cost for a given application deployment. Experiments with a microgrid energy management application developed using a decentralized software platform show that the deployment configuration can play an important role in enhancing the resilience capabilities of distributed applications as well as reducing the resource demands on individual nodes even without modifying the control logic.
△ Less
Submitted 26 June, 2022;
originally announced June 2022.
-
Modular Medium Voltage AC to Low Voltage DC Converter for Extreme Fast Charging Applications
Authors:
M A Awal,
Iqbal Husain,
Md Rashed Hassan Bipu,
Oscar Andreas Montes,
Fei Teng,
Hao Feng,
Mehnaz Khan,
Srdjan Lukic
Abstract:
A modular and scalable converter for medium voltage (MV) AC to low voltage (LV) DC power conversion is proposed; single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration to reach desired voltage and power capacity. In prior art, high-speed bidirectional communication among modules…
▽ More
A modular and scalable converter for medium voltage (MV) AC to low voltage (LV) DC power conversion is proposed; single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration to reach desired voltage and power capacity. In prior art, high-speed bidirectional communication among modules and a centralized controller is required to ensure module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power systems. Moreover, large capacitors are used to suppress double-line-frequency voltage variations on the common MV DC bus shared by the AFE and the DC-DC stage originating from AC power pulsations through the SPMs. We propose a comprehensive controller which achieves voltage and power balancing using complete decentralized control of the DC-DC stages based on only local sensor feedback and the AFE stages are controlled using feedback of only the LV DC output. Furthermore, reduced capacitor requirement on the MV DC bus is achieved through design and control. The proposed method is validated through simulation and experimental results.
△ Less
Submitted 8 July, 2020;
originally announced July 2020.
-
Systematic reduction of the proton-removal cross section in neutron-rich medium-mass nuclei
Authors:
J. Díaz-Cortés,
J. Benlliure,
J. L. Rodríguez-Sánchez,
H. Álvarez-Pol,
T. Aumann,
C. A. Bertulani,
B. Blank,
E. Casarejos,
D. Cortina-Gil,
D. Dragosavac,
V. Föhr,
A. Gargano,
M. Gascón,
W. Gawlikowicz,
A. Heinz,
K. Helariutta,
A. Kelić-Heil,
S. Lukić,
F. Montes,
D. Pérez-Loureiro,
L. Pieńkowski,
K-H. Schmidt,
M. Staniou,
K. Subotić,
K. Sümmerer
, et al. (2 additional authors not shown)
Abstract:
Single neutron- and proton-removal cross sections have been systematically measured for 72 medium-mass neutron-rich nuclei around Z=50 and energies around 900A MeV using the FRagment Separator (FRS) at GSI. Neutron-removal cross sections are described by considering the knock-out process together with initial- and final-state interactions. Proton-removal cross sections are, however, significantly…
▽ More
Single neutron- and proton-removal cross sections have been systematically measured for 72 medium-mass neutron-rich nuclei around Z=50 and energies around 900A MeV using the FRagment Separator (FRS) at GSI. Neutron-removal cross sections are described by considering the knock-out process together with initial- and final-state interactions. Proton-removal cross sections are, however, significantly smaller than predicted by the same calculations. The observed difference can be explained as due to the knockout of short-correlated protons in neutron-proton dominating pairs.
△ Less
Submitted 10 June, 2020;
originally announced June 2020.
-
Ultra-Fast Hadronic Calorimetry
Authors:
Dmitri Denisov,
Strahinja Lukić,
Nikolai Mokhov,
Sergei Striganov,
Predrag Ujić
Abstract:
Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-sc…
▽ More
Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-scintillator hadronic calorimeter. In the beam tests, scintillator signals induced by hadronic showers in steel are sampled with a period of 0.2 ns and precisely time-aligned in order to study the average signal waveform at various locations with respect to the beam particle impact. Simulations of the same setup are performed using the MARS15 code. Both simulation and test beam results suggest that energy deposition in steel calorimeters develop over a time shorter than 2 ns providing opportunity for ultra-fast calorimetry. Simulation results for an "ideal" calorimeter consisting exclusively of bulk tungsten or copper are presented to establish the lower limit of the signal integration window.
△ Less
Submitted 19 May, 2018; v1 submitted 18 December, 2017;
originally announced December 2017.
-
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Borysova,
I. Bozovic-Jelisavcic,
G. Chelkov,
W. Daniluk,
D. Dannheim,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempel,
H. Henschel,
M. Idzik,
A. Ignatenko,
A. Ishikawa,
S. Kananov,
O. Karacheban,
W. Klempt
, et al. (35 additional authors not shown)
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t…
▽ More
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
△ Less
Submitted 12 March, 2018; v1 submitted 10 May, 2017;
originally announced May 2017.
-
Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout
Authors:
Dmitri Denisov,
Valery Evdokimov,
Strahinja Lukić,
Predrag Ujić
Abstract:
Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.
Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as time resolution of 330 ps and position resolution along the strip of 5.4 cm.
△ Less
Submitted 23 December, 2016; v1 submitted 10 November, 2016;
originally announced November 2016.
-
Higgs physics at CLIC
Authors:
Strahinja Lukić
Abstract:
The Compact Linear Collider CLIC is an option for a future multi-TeV electron-positron collider, offering the potential for a rich precision physics programme, combined with sensitivity to a wide range of new phenomena. The CLIC physics potential for measurements of the 125 GeV Higgs boson has been studied using full detector simulations for several centre-of-mass energies. The presented results p…
▽ More
The Compact Linear Collider CLIC is an option for a future multi-TeV electron-positron collider, offering the potential for a rich precision physics programme, combined with sensitivity to a wide range of new phenomena. The CLIC physics potential for measurements of the 125 GeV Higgs boson has been studied using full detector simulations for several centre-of-mass energies. The presented results provide crucial input to the energy staging strategy for the CLIC accelerator. The complete physics program for measurements of accessible Higgs boson couplings is presented in this contribution. The ultimate measurement precision is reached when all measurements available at a given centre-of-mass energy are included in combined fits. Operation at a few hundred GeV allows the couplings and width of the Higgs boson to be determined in a model-independent manner through the study of the Higgsstrahlung and WW-fusion processes. At a lepton collider, the measurement of the Higgsstrahlung cross section using the recoil mass technique sets the absolute scale for all Higgs coupling measurements. Recently, it has been shown that including both the leptonic and the hadronic decays of the Z boson in this approach improves the statistical precision significantly. Operation at higher centre-of-mass energies provides large statistics for the study of Higgs boson decays and the potential to directly measure the top Yukawa coupling. At the highest centre-of-mass energy (presently assumed to be 3 TeV), the Higgs boson self-coupling can be determined with 10% precision.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
Higgs Physics at the CLIC Electron-Positron Linear Collider
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
N. Alipour Tehrani,
C. Balázs,
Y. Benhammou,
M. Benoit,
B. Bilki,
J. -J. Blaising,
M. J. Boland,
M. Boronat,
O. Borysov,
I. Božović-Jelisavčić,
M. Buckland,
S. Bugiel,
P. N. Burrows,
T. K. Charles,
W. Daniluk,
D. Dannheim,
R. Dasgupta,
M. Demarteau,
M. A. Díaz Gutierrez,
G. Eigen,
K. Elsener,
U. Felzmann
, et al. (99 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3…
▽ More
The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3 TeV. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (e+e- -> ZH) and WW-fusion (e+e- -> Hnunu), resulting in precise measurements of the production cross sections, the Higgs total decay width Gamma_H, and model-independent determinations of the Higgs couplings. Operation at sqrt(s) > 1 TeV provides high-statistics samples of Higgs bosons produced through WW-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes e+e- -> ttH and e+e- -> HHnunu allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.
△ Less
Submitted 5 June, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Muon Beam at the Fermilab Test Beam Area
Authors:
Dmitri Denisov,
Valery Evdokimov,
Strahinja Lukić,
Predrag Ujić
Abstract:
The intensities and profiles of the muon beam behind the beam dump of the Fermilab test beam area when the facility is running in the "pion" beam mode are measured and summarized in this note. This muon beam with momenta in the range 10 - 50 GeV/c provides an opportunity to perform various measurements in parallel with other users of the test beam area.
The intensities and profiles of the muon beam behind the beam dump of the Fermilab test beam area when the facility is running in the "pion" beam mode are measured and summarized in this note. This muon beam with momenta in the range 10 - 50 GeV/c provides an opportunity to perform various measurements in parallel with other users of the test beam area.
△ Less
Submitted 11 August, 2016;
originally announced August 2016.
-
Results from the October 2014 CERN test beam of LumiCal
Authors:
O. Borysov,
V. Ghenescu,
A. Levy,
I. Levy,
S. Lukic,
J. Moron,
A. T. Neagu,
T. Preda,
O. Rosenblat
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, was tested in the CERN PS accelerator T9 testbeam. The objective of this test beam was to demonstrate a multi-plane operation, to study the development of the electromagnetic shower and to compare it with MC simulations.
A prototype of a luminometer, designed for a future e+e- collider detector, was tested in the CERN PS accelerator T9 testbeam. The objective of this test beam was to demonstrate a multi-plane operation, to study the development of the electromagnetic shower and to compare it with MC simulations.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Measurement of the Higgs decay to electroweak bosons at low and intermediate CLIC energies
Authors:
Ivanka Božović-Jelisavčić,
Gordana Milutinović-Dumbelović,
Mila Pandurović,
Strahinja Lukić
Abstract:
In this paper a simulation of measurements of the Higgs boson decay to electroweak bosons in $e^+e^-$ collisions at CLIC is presented. Higgs boson production and subsequent $H\rightarrow ZZ^\ast$ and $H\rightarrow WW^\ast$ decay processes were simulated alongside the relevant background processes at 350 GeV and 1.4 TeV center-of-mass energy. Full detector simulation and event reconstruction were u…
▽ More
In this paper a simulation of measurements of the Higgs boson decay to electroweak bosons in $e^+e^-$ collisions at CLIC is presented. Higgs boson production and subsequent $H\rightarrow ZZ^\ast$ and $H\rightarrow WW^\ast$ decay processes were simulated alongside the relevant background processes at 350 GeV and 1.4 TeV center-of-mass energy. Full detector simulation and event reconstruction were used under realistic beam conditions. The achievable statistical precision of the measured product of the Higgs production cross section and the branching ratio for the analysed decays has been determined.
△ Less
Submitted 29 March, 2016;
originally announced March 2016.
-
Time and Position Resolution of the Scintillator Strips for a Muon System at Future Colliders
Authors:
Dmitri Denisov,
Valery Evdokimov,
Strahinja Lukić
Abstract:
Prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.
Prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.
△ Less
Submitted 29 March, 2016; v1 submitted 21 December, 2015;
originally announced December 2015.
-
Tests of Scintillator+WLS strips for Muon System at Future Colliders
Authors:
Dmitri Denisov,
Valery Evdokimov,
Strahinja Lukić
Abstract:
Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~7 cm.
Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~7 cm.
△ Less
Submitted 11 October, 2015;
originally announced October 2015.
-
Physics potential for the measurement of ${σ(Hν\barν)\times \text{BR}(H\rightarrowμ^+μ^-)}$ at the 1.4 TeV CLIC collider
Authors:
G. Milutinović-Dumbelović,
I. Božović-Jelisavčić,
C. Grefe,
G. Kačarević,
S. Lukić,
M. Pandurović,
P. Roloff,
I. Smiljanić
Abstract:
The future Compact Linear Collider (CLIC) offers a possibility for a rich precision physics programme, in particular in the Higgs sector through the energy staging. This is the first paper addressing the measurement of the Standard Model Higgs boson decay into two muons at 1.4 TeV CLIC. With respect to similar studies at future linear colliders, this paper includes several novel contributions to t…
▽ More
The future Compact Linear Collider (CLIC) offers a possibility for a rich precision physics programme, in particular in the Higgs sector through the energy staging. This is the first paper addressing the measurement of the Standard Model Higgs boson decay into two muons at 1.4 TeV CLIC. With respect to similar studies at future linear colliders, this paper includes several novel contributions to the statistical uncertainty of the measurement. The later includes the Equivalent Photon Approximation and realistic forward electron tagging based on energy deposition maps in the forward calorimeters, as well as several processes with the Beamstrahlung photons that results in irreducible contribution to the signal. In addition, coincidence of the Bhabha scattering with the signal and background processes is considered, altering the signal selection efficiency. The study is performed using a fully simulated CLIC_ILD detector model. It is shown that the branching ratio for the Higgs decay into a pair of muons BR(${H\rightarrowμ^+μ^-}$) times the Higgs production cross-section in $WW$-fusion $σ(Hν\barν)$ can be measured with 38% statistical accuracy at ${\sqrt{s} =\text{1.4 TeV}}$, assuming an integrated luminosity of 1.5 ab$^{-1}$ with unpolarised beams. If 80% electron beam polarisation is considered, the statistical uncertainty of the measurement is reduced to 25%. Systematic uncertainties are negligible in comparison to the statistical uncertainty.
△ Less
Submitted 21 July, 2015; v1 submitted 16 July, 2015;
originally announced July 2015.
-
Physics potential for the measurement of sigma(Hvv)*BR(H->mu+mu-) at a 1.4 TeV CLIC collider
Authors:
G. Milutinović-Dumbelović,
I. Božović-Jelisavčić,
C. Grefe,
S. Lukić,
M. Pandurović,
P. Roloff
Abstract:
The potential for the measurement of the branching ratio of the Standard Model-like Higgs boson decay into a mu+mu- pair at 1.4 TeV CLIC is analysed. The study is performed using the fully simulated CLIC_ILD detector concept, taking into consideration all the relevant physics and the beam-induced backgrounds. Despite the very low branching ratio of the H->mu+mu- decay, we show that the product of…
▽ More
The potential for the measurement of the branching ratio of the Standard Model-like Higgs boson decay into a mu+mu- pair at 1.4 TeV CLIC is analysed. The study is performed using the fully simulated CLIC_ILD detector concept, taking into consideration all the relevant physics and the beam-induced backgrounds. Despite the very low branching ratio of the H->mu+mu- decay, we show that the product of the branching ratio times the Higgs production cross section can be measured with a statistical uncertainty of 38 percent, assuming an integrated luminosity of 1.5 ab^-1 collected in five years of the detector operation at the 1.4 TeV CLIC with unpolarised beams. With polarised beams (-80%, +30%), the statistical uncertainty is better than 25%.
△ Less
Submitted 18 December, 2014;
originally announced December 2014.
-
Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN
Authors:
n_TOF Collaboration,
:,
E. Mendoza,
D. Cano-Ott,
C. Guerrero,
E. Berthoumieux,
U. Abbondanno,
G. Aerts,
F. Alvarez-Velarde,
S. Andriamonje,
J. Andrzejewski,
P. Assimakopoulos,
L. Audouin,
G. Badurek,
J. Balibrea,
P. Baumann,
F. Becvar,
F. Belloni,
F. Calvino,
M. Calviani,
R. Capote,
C. Carrapico,
A. Carrillo de Albornoz,
P. Cennini,
V. Chepel
, et al. (108 additional authors not shown)
Abstract:
Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV an…
▽ More
Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV and 2.5 keV. Results: The $^{243}$Am(n,$γ$) cross section has been successfully measured in the mentioned energy range. The resolved resonance region has been extended from 250 eV up to 400 eV. In the unresolved resonance region our results are compatible with one of the two incompatible capture data sets available below 2.5 keV. The data available in EXFOR and in the literature has been used to perform a simple analysis above 2.5 keV. Conclusions: The results of this measurement contribute to reduce the $^{243}$Am(n,$γ$) cross section uncertainty and suggest that this cross section is underestimated up to 25% in the neutron energy range between 50 eV and a few keV in the present evaluated data libraries.
△ Less
Submitted 4 December, 2014;
originally announced December 2014.
-
ECFA Detector R&D Panel, Review Report
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
P. Bambade,
L. Bortko,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
A. Dragone,
L. Dumitru,
K. Elsener,
I. Emeliantchik,
E. Firu,
J. Fischer,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
G. Grzelak,
G. Haller,
H. Henschel
, et al. (46 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
△ Less
Submitted 19 November, 2014; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
D. Avila,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Bergholz,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
L. Dumitru,
K. Elsener,
V. Fadeyev,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
H. Henschel
, et al. (44 additional authors not shown)
Abstract:
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens…
▽ More
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
△ Less
Submitted 1 June, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Physics highlights at ILC and CLIC
Authors:
Strahinja Lukić
Abstract:
In this lecture, the physics potential for the e+e- linear collider experiments ILC and CLIC is reviewed. The experimental conditions are compared to those at hadron colliders and their intrinsic value for precision experiments, complementary to the hadron colliders, is discussed. The detector concepts for ILC and CLIC are outlined in their most important aspects related to the precision physics.…
▽ More
In this lecture, the physics potential for the e+e- linear collider experiments ILC and CLIC is reviewed. The experimental conditions are compared to those at hadron colliders and their intrinsic value for precision experiments, complementary to the hadron colliders, is discussed. The detector concepts for ILC and CLIC are outlined in their most important aspects related to the precision physics. Highlights from the physics program and from the benchmark studies are given. It is shown that linear colliders are a promising tool, complementing the LHC in essential ways to test the Standard Model and to search for new physics.
△ Less
Submitted 17 June, 2014;
originally announced June 2014.
-
Precision luminosity measurement at ILC
Authors:
I. Bozovic-Jelisavcic,
S. Lukic,
M. Pandurovic,
I. Smiljanic
Abstract:
In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective met…
▽ More
In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective methods we introduce, leads to the systematic uncertainty from the beam-induced effects to be at a few permille level in the peak region above the 80% of the nominal centre-of-mass energies at ILC.
△ Less
Submitted 28 March, 2014;
originally announced March 2014.
-
SM-like Higgs decay into two muons at 1.4 TeV CLIC
Authors:
I. Bozovic-Jelisavcic,
S. Lukic,
G. Milutinovic-Dumbelovic,
M. Pandurovic
Abstract:
The branching fraction measurement of the SM-like Higgs boson decay into two muons at 1.4 TeV CLIC will be described in this paper contributed to the LCWS13. The study is performed in the fully simulated ILD detector concept for CLIC, taking into consideration all the relevant physics and the beam-induced backgrounds, as well as the instrumentation of the very forward region to tag the high-energy…
▽ More
The branching fraction measurement of the SM-like Higgs boson decay into two muons at 1.4 TeV CLIC will be described in this paper contributed to the LCWS13. The study is performed in the fully simulated ILD detector concept for CLIC, taking into consideration all the relevant physics and the beam-induced backgrounds, as well as the instrumentation of the very forward region to tag the high-energy electrons. Higgs couplings are known to be sensitive to BSM physics and we prove that BR times the Higgs production cross section can be measured with approximately 35.5% statistical accuracy in four years of the CLIC operation at 1.4 TeV centre-of-mass energy with unpolarised beams. The result is preliminary as the equivalent photon approximation is not considered in the cross-section calculations. This study complements the Higgs physics program foreseen at CLIC.
△ Less
Submitted 26 March, 2014;
originally announced March 2014.
-
Physics at the CLIC e+e- Linear Collider -- Input to the Snowmass process 2013
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstatin Afanaciev,
Gideon Alexander,
Niloufar Alipour Tehrani,
Oscar Alonso,
Kristoffer K. Andersen,
Samir Arfaoui,
Csaba Balazs,
Tim Barklow,
Marco Battaglia,
Mathieu Benoit,
Burak Bilki,
Jean-Jacques Blaising,
Mark Boland,
Marça Boronat,
Ivanka Božović Jelisavčić,
Philip Burrows,
Maximilien Chefdeville,
Roberto Contino,
Dominik Dannheim,
Marcel Demarteau,
Marco Aurelio Diaz Gutierrez,
Angel Diéguez,
Jorge Duarte Campderros
, et al. (98 additional authors not shown)
Abstract:
This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accomp…
▽ More
This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accompanied by a paper describing the CLIC accelerator study, submitted to the Frontier Capabilities group of the Snowmass process.
△ Less
Submitted 30 September, 2013; v1 submitted 19 July, 2013;
originally announced July 2013.
-
A note on the space of evolutionary operators in population genetics and folding dynamics
Authors:
Sergio Lukic
Abstract:
Discrete dynamical systems defined by the iteration of a polynomial map of the unit simplex to itself appear in the context of population genetic systems evolving under mutation, recombination and weak selection. Although exceptional progress has been made in finding particular solutions to these systems, our knowledge of the general properties of the space of all possible dynamical systems of thi…
▽ More
Discrete dynamical systems defined by the iteration of a polynomial map of the unit simplex to itself appear in the context of population genetic systems evolving under mutation, recombination and weak selection. Although exceptional progress has been made in finding particular solutions to these systems, our knowledge of the general properties of the space of all possible dynamical systems of this kind is still limited. We prove that the space of bounded-degree polynomial maps of the unit simplex to itself is a compact and convex subset of a Euclidean space. We provide an explicit characterization of such a space and of its boundary. A special class of maps in the boundary, the folding maps, which generalize the logistic map for any dimension and degree are defined and constructed. Finally, we use numerical methods to study the ergodic and mixing properties of maps in the neighborhood of several of these folding maps.
△ Less
Submitted 12 July, 2013; v1 submitted 1 May, 2013;
originally announced May 2013.
-
Luminosity measurement at ILC
Authors:
I. Bozovic-Jelisavcic,
S. Lukic,
G. Milutinovic Dumbelovic,
M. Pandurovic,
I. Smiljanic
Abstract:
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced…
▽ More
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced to a permille independently of the precision with which the beam parameters are known. With the specific event selection, different from the isolation cuts based on topology of the signal used at LEP, combined with the corrective methods we introduce, the overall systematic uncertainty in the peak region above 80% of the nominal center-of-mass energy meets the physics requirements to be at the few permille level at all ILC energies.
△ Less
Submitted 21 August, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Correction of beam-beam effects in luminosity measurement in the forward region at CLIC
Authors:
Strahinja Lukic
Abstract:
Procedures for correcting the beam-beam effects in luminosity measurements at CLIC at 3 TeV center-of-mass energy are described and tested using Monte Carlo simulations. The angular counting loss due to the combined Beamstrahlung and initial-state radiation effects is corrected based on the reconstructed velocity of the collision frame of the Bhabha scattering. The distortion of the luminosity spe…
▽ More
Procedures for correcting the beam-beam effects in luminosity measurements at CLIC at 3 TeV center-of-mass energy are described and tested using Monte Carlo simulations. The angular counting loss due to the combined Beamstrahlung and initial-state radiation effects is corrected based on the reconstructed velocity of the collision frame of the Bhabha scattering. The distortion of the luminosity spectrum due to the initial-state radiation is corrected by deconvolution. At the end, the counting bias due to the finite calorimeter energy resolution is numerically corrected. To test the procedures, BHLUMI Bhabha event generator, and Guinea-Pig beam-beam simulation were used to generate the outgoing momenta of Bhabha particles in the bunch collisions at CLIC. The systematic effects of the beam-beam interaction on the luminosity measurement are corrected with precision of 1.4 permille in the upper 5% of the energy, and 2.7 permille in the range between 80 and 90% of the nominal center-of-mass energy.
△ Less
Submitted 23 April, 2013; v1 submitted 8 January, 2013;
originally announced January 2013.
-
Correction of beam-beam effects in luminosity measurement at ILC
Authors:
Strahinja Lukić,
Ivan Smiljanić
Abstract:
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The second method uses the experimentally reconstructed shape of the $\sqrt{s'}$ spectrum to determine the Beamstrahlung component of the bias. The last, recently p…
▽ More
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The second method uses the experimentally reconstructed shape of the $\sqrt{s'}$ spectrum to determine the Beamstrahlung component of the bias. The last, recently proposed, collision-frame method relies on the reconstruction of the collision-frame velocity to define the selection function in the collision frame both in experiment and in theory. Thus the luminosity expression is insensitive to the difference between the CM frame of the collision and the lab frame. The collision-frame method is independent of the knowledge of the beam parameters, and it allows an accurate reconstruction of the luminosity spectrum above 80 % of the nominal CM energy. However, it gives no precise infromation about luminosity below 80 % of the nominal CM energy. The compatibility of diverse selection cuts for background reduction with the collision-frame method is addressed.
△ Less
Submitted 4 March, 2013; v1 submitted 29 November, 2012;
originally announced November 2012.
-
High-precision measurement of total fission cross sections in spallation reactions of 208Pb and 238U
Authors:
K. -H. Schmidt,
B. Jurado,
R. Pleskac,
M. V. Ricciardi,
J. Benlliure,
T. Enqvist,
F. Farget,
A. Bacquias,
L. Giot,
V. Henzl,
D. Henzlova,
A. Kelic-Heil,
S. Leray,
S. Lukic,
Son Nguyen Ngoc,
A. Boudard,
E. Casarejos,
M. Fernandez,
T. Kurtukian,
P. Nadtochy,
D. Perez,
C. Schmitt
Abstract:
Total cross sections for proton- and deuteron-induced-fission of 208Pb and 238U have been determined in the energy range between 500 MeV and 1 GeV. The experiment has been performed in inverse kinematics at GSI Darmstadt, facilitating the counting of the projectiles and the identification of the reaction products. High precision between 5 and 7 percent has been achieved by individually counting th…
▽ More
Total cross sections for proton- and deuteron-induced-fission of 208Pb and 238U have been determined in the energy range between 500 MeV and 1 GeV. The experiment has been performed in inverse kinematics at GSI Darmstadt, facilitating the counting of the projectiles and the identification of the reaction products. High precision between 5 and 7 percent has been achieved by individually counting the beam particles and by registering both fission fragments in coincidence with high efficiency and full Z resolution. Fission was clearly distinguished from other reaction channels. The results were found to deviate by up to 30 percent from Prokofiev's systematics on total fission cross sections. There is good agreement with an elaborate experiment performed in direct kinematics.
△ Less
Submitted 30 August, 2012;
originally announced August 2012.
-
Measurement of the gas-flow reduction factor of the KATRIN DPS2-F differential pum** section
Authors:
S. Lukic,
B. Bornschein,
L. Bornschein,
G. Drexlin,
A. Kosmider,
K. Schloesser,
A. Windberger
Abstract:
The gas-flow reduction factor of the second forward Differential Pum** Section (DPS2-F) for the KATRIN experiment was determined using a dedicated vacuum-measurement setup and by detailed molecular-flow simulation of the DPS2-F beam tube and of the measurement apparatus. In the measurement, non-radioactive test gases deuterium, helium, neon, argon and krypton were used, the input gas flow was pr…
▽ More
The gas-flow reduction factor of the second forward Differential Pum** Section (DPS2-F) for the KATRIN experiment was determined using a dedicated vacuum-measurement setup and by detailed molecular-flow simulation of the DPS2-F beam tube and of the measurement apparatus. In the measurement, non-radioactive test gases deuterium, helium, neon, argon and krypton were used, the input gas flow was provided by a commercial mass-flow controller, and the output flow was measured using a residual gas analyzer, in order to distinguish it from the outgassing background. The measured reduction factor with the empty beam tube at room temperature for gases with mass 4 is 1.8(4)E4, which is in excellent agreement with the simulated value of 1.6E4. The simulated reduction factor for tritium, based on the interpolated value for the capture factor at the turbo-molecular pump inlet flange is 2.5E4. The difference with respect to the design value of 1E5 is due to the modifications in the beam tube geometry since the initial design, and can be partly recovered by reduction of the effective beam tube diameter.
△ Less
Submitted 31 October, 2011; v1 submitted 1 July, 2011;
originally announced July 2011.
-
Experimental study of fragmentation products in the reactions 112Sn + 112Sn and 124Sn + 124Sn at 1 AGeV
Authors:
V. Föhr,
A. Bacquias,
E. Casarejos,
T. Enqvist,
A. R. Junghans,
A. Kelić-Heil,
T. Kurtukian,
S. Lukić,
D. Pérez-Loureiro,
R. Pleskač,
M. V. Ricciardi,
K. -H. Schmidt,
J. Taïeb
Abstract:
Production cross-sections and longitudinal velocity distributions of the projectile-like residues produced in the reactions 112Sn + 112Sn and 124Sn + 124Sn both at an incident beam energy of 1 AGeV were measured with the high-resolution magnetic spectrometer, the Fragment Separator (FRS) of GSI. For both reactions the characteristics of the velocity distributions and nuclide production cross secti…
▽ More
Production cross-sections and longitudinal velocity distributions of the projectile-like residues produced in the reactions 112Sn + 112Sn and 124Sn + 124Sn both at an incident beam energy of 1 AGeV were measured with the high-resolution magnetic spectrometer, the Fragment Separator (FRS) of GSI. For both reactions the characteristics of the velocity distributions and nuclide production cross sections were determined for residues with atomic number Z $\geq$ 10. A comparison of the results of the two reactions is presented.
△ Less
Submitted 27 June, 2011;
originally announced June 2011.
-
Production of neutron-rich nuclei in fragmentation reactions of 132Sn projectiles at relativistic energies
Authors:
D. Pérez-Loureiro,
J. Benlliure,
H. Álvarez-Pol,
B. Blank,
E. Casarejos,
D. Dragosavac,
V. Föhr,
M. Gascón,
W. Gawlikowicz,
A. Heinz,
K. Helariutta,
A. Kelić,
S. Lukić,
F. Montes,
L. Pieńkowski,
K-H. Schmidt,
M. Staniou,
K. Subotić,
K. Sümmerer,
J. Taieb,
A. Trzcińska
Abstract:
The fragmentation of neutron-rich 132Sn nuclei produced in the fission of 238U projectiles at 950 MeV/u has been investigated at the FRagment Separator (FRS) at GSI. This work represents the first investigation of fragmentation of medium-mass radioactive projectiles with a large neutron excess. The measured production cross sections of the residual nuclei are relevant for the possible use of a two…
▽ More
The fragmentation of neutron-rich 132Sn nuclei produced in the fission of 238U projectiles at 950 MeV/u has been investigated at the FRagment Separator (FRS) at GSI. This work represents the first investigation of fragmentation of medium-mass radioactive projectiles with a large neutron excess. The measured production cross sections of the residual nuclei are relevant for the possible use of a two-stage reaction scheme (fission+fragmentation) for the production of extremely neutron-rich medium-mass nuclei in future rare-ion-beam facilities. Moreover, the new data will provide a better understanding of the "memory" effect in fragmentation reactions.
△ Less
Submitted 3 May, 2011;
originally announced May 2011.
-
Non-equilibrium allele frequency spectra via spectral methods
Authors:
Sergio Lukic,
Jody Hey,
Kevin Chen
Abstract:
A major challenge in the analysis of population genomics data consists of isolating signatures of natural selection from background noise caused by random drift and gene flow. Analyses of massive amounts of data from many related populations require high-performance algorithms to determine the likelihood of different demographic scenarios that could have shaped the observed neutral single nucleoti…
▽ More
A major challenge in the analysis of population genomics data consists of isolating signatures of natural selection from background noise caused by random drift and gene flow. Analyses of massive amounts of data from many related populations require high-performance algorithms to determine the likelihood of different demographic scenarios that could have shaped the observed neutral single nucleotide polymorphism (SNP) allele frequency spectrum. In many areas of applied mathematics, Fourier Transforms and Spectral Methods are firmly established tools to analyze spectra of signals and model their dynamics as solutions of certain Partial Differential Equations (PDEs). When spectral methods are applicable, they have excellent error properties and are the fastest possible in high dimension. In this paper we present an explicit numerical solution, using spectral methods, to the forward Kolmogorov equations for a Wright-Fisher process with migration of K populations, influx of mutations, and multiple population splitting events.
△ Less
Submitted 25 February, 2011; v1 submitted 29 October, 2010;
originally announced November 2010.
-
Ion source for tests of ion behavior in the KATRIN beam line
Authors:
S. Lukic,
B. Bornschein,
G. Drexlin,
F. Glück,
O. Kazachenko,
M. Schöppner,
Ch. Weinheimer,
M. C. R. Zoll
Abstract:
An electron-impact ion source based on photoelectron emission was developed for ionization of gases at pressures below 1e-4 mbar in an axial magnetic field in the order of 5 T. The ion source applies only DC fields, which makes it suitable for use in the presence of equipment sensitive to radio-frequency (RF) fields. The ion source was succesfully tested under varying conditions regarding pressure…
▽ More
An electron-impact ion source based on photoelectron emission was developed for ionization of gases at pressures below 1e-4 mbar in an axial magnetic field in the order of 5 T. The ion source applies only DC fields, which makes it suitable for use in the presence of equipment sensitive to radio-frequency (RF) fields. The ion source was succesfully tested under varying conditions regarding pressure, magnetic field and magnetic-field gradient, and the results were studied with the help of simulations. The processes in the ion source are well understood and possibilities for further optimization of generated ion currents are clarified.
△ Less
Submitted 21 January, 2011; v1 submitted 19 August, 2010;
originally announced August 2010.
-
A broad-Band FT-ICR Penning TRap System for KATRIN
Authors:
M. Ubieto-Diaz,
D. Rodriguez,
S. Lukic,
Sz. Nagy,
S. Stahl,
K. Blaum
Abstract:
The KArlsruhe TRItium Neutrino experiment KATRIN aims at improving the upper limit of the mass of the electron antineutrino to about 0.2 eV (90% c.l.) by investigating the beta-decay of tritium gas molecules. The experiment is currently under construction to start first data taking in 2012. One source of systematic uncertainties in the KATRIN experiment is the formation of ion clusters when trit…
▽ More
The KArlsruhe TRItium Neutrino experiment KATRIN aims at improving the upper limit of the mass of the electron antineutrino to about 0.2 eV (90% c.l.) by investigating the beta-decay of tritium gas molecules. The experiment is currently under construction to start first data taking in 2012. One source of systematic uncertainties in the KATRIN experiment is the formation of ion clusters when tritium decays and decay products interact with residual tritium molecules. It is essential to monitor the abundances of these clusters since they have different final state energies than tritium ions. For this purpose, a prototype of a cylindrical Penning trap has been constructed and tested at the Max-Planck-Institute for Nuclear Physics in Heidelberg, which will be installed in the KATRIN beam line. This system employs the technique of Fourier-Transform Ion-Cyclotron-Resonance in order to measure the abundances of the different stored ion species.
△ Less
Submitted 20 July, 2009;
originally announced July 2009.
-
Numerical Weil-Petersson metrics on moduli spaces of Calabi-Yau manifolds
Authors:
Julien Keller,
Sergio Lukic
Abstract:
We introduce a simple and very fast algorithm that computes Weil-Petersson metrics on moduli spaces of polarized Calabi-Yau manifolds. Also, by using Donaldson's quantization link between the infinite and finite dimensional G.I.T quotients that describe moduli spaces of varieties, we define a natural sequence of Kaehler metrics. We prove that the sequence converges to the Weil-Petersson metric. We…
▽ More
We introduce a simple and very fast algorithm that computes Weil-Petersson metrics on moduli spaces of polarized Calabi-Yau manifolds. Also, by using Donaldson's quantization link between the infinite and finite dimensional G.I.T quotients that describe moduli spaces of varieties, we define a natural sequence of Kaehler metrics. We prove that the sequence converges to the Weil-Petersson metric. We also develop an algorithm that numerically approximates such metrics, and hence the Weil-Petersson metric itself. Explicit examples are provided on a family of Calabi-Yau Quintic hypersurfaces in CP^4. The scope of our second algorithm is much broader; the same techniques can be used to approximate metrics on null spaces of Dirac operators coupled to Hermite Yang-Mills connections.
△ Less
Submitted 8 July, 2012; v1 submitted 9 July, 2009;
originally announced July 2009.
-
Balanced metrics and noncommutative Kaehler geometry
Authors:
Sergio Lukic
Abstract:
In this paper we show how Einstein metrics are naturally described using the quantization of the algebra of functions on a Kahler manifold M. In this setup one interprets M as the phase space itself, equipped with the Poisson brackets inherited from the Kahler 2-form. We compare the geometric quantization framework with several deformation quantization approaches. We find that the balanced metrics…
▽ More
In this paper we show how Einstein metrics are naturally described using the quantization of the algebra of functions on a Kahler manifold M. In this setup one interprets M as the phase space itself, equipped with the Poisson brackets inherited from the Kahler 2-form. We compare the geometric quantization framework with several deformation quantization approaches. We find that the balanced metrics appear naturally as a result of setting the vacuum energy to be the constant function on the moduli space of semiclassical vacua. In the classical limit these metrics become Kahler-Einstein (when M admits such metrics). Finally, we sketch several applications of this formalism, such as explicit constructions of special Lagrangian submanifolds in compact Calabi-Yau manifolds.
△ Less
Submitted 29 September, 2010; v1 submitted 8 October, 2007;
originally announced October 2007.
-
Flux corrections to anomaly cancellation in M-theory on a manifold with boundary
Authors:
Sergio Lukic,
Gregory W. Moore
Abstract:
We show how the coupling of gravitinos and gauginos to fluxes modifies anomaly cancellation in M-theory on a manifold with boundary. Anomaly cancellation continues to hold, after a shift of the definition of the gauge currents by a local gauge invariant expression in the curvatures and E8 fieldstrengths. We compute the first nontrivial correction of this kind. Warning: Ian Moss has called into que…
▽ More
We show how the coupling of gravitinos and gauginos to fluxes modifies anomaly cancellation in M-theory on a manifold with boundary. Anomaly cancellation continues to hold, after a shift of the definition of the gauge currents by a local gauge invariant expression in the curvatures and E8 fieldstrengths. We compute the first nontrivial correction of this kind. Warning: Ian Moss has called into question several of the numerical coefficients in the extended Dirac operators in this paper. We have not confirmed this but the reader is warned not to trust the precise coefficients in the formulae for the Dirac operators and heat kernel expansions. We believe these possible errors do not change our qualitative conclusions. One of us intends to return to the issue and recheck the formulae. We thank Ian Moss for pointing out these problems.
△ Less
Submitted 13 November, 2013; v1 submitted 20 February, 2007;
originally announced February 2007.
-
Numerical Calabi-Yau metrics
Authors:
Michael R. Douglas,
Robert L. Karp,
Sergio Lukic,
Rene Reinbacher
Abstract:
We develop numerical methods for approximating Ricci flat metrics on Calabi-Yau hypersurfaces in projective spaces. Our approach is based on finding balanced metrics, and builds on recent theoretical work by Donaldson. We illustrate our methods in detail for a one parameter family of quintics. We also suggest several ways to extend our results.
We develop numerical methods for approximating Ricci flat metrics on Calabi-Yau hypersurfaces in projective spaces. Our approach is based on finding balanced metrics, and builds on recent theoretical work by Donaldson. We illustrate our methods in detail for a one parameter family of quintics. We also suggest several ways to extend our results.
△ Less
Submitted 11 December, 2006;
originally announced December 2006.
-
Numerical solution to the hermitian Yang-Mills equation on the Fermat quintic
Authors:
Michael R. Douglas,
Robert L. Karp,
Sergio Lukic,
Rene Reinbacher
Abstract:
We develop an iterative method for finding solutions to the hermitian Yang-Mills equation on stable holomorphic vector bundles, following ideas recently developed by Donaldson. As illustrations, we construct numerically the hermitian Einstein metrics on the tangent bundle and a rank three vector bundle on P^2. In addition, we find a hermitian Yang-Mills connection on a stable rank three vector b…
▽ More
We develop an iterative method for finding solutions to the hermitian Yang-Mills equation on stable holomorphic vector bundles, following ideas recently developed by Donaldson. As illustrations, we construct numerically the hermitian Einstein metrics on the tangent bundle and a rank three vector bundle on P^2. In addition, we find a hermitian Yang-Mills connection on a stable rank three vector bundle on the Fermat quintic.
△ Less
Submitted 18 July, 2006; v1 submitted 27 June, 2006;
originally announced June 2006.
-
Systematic comparison of ISOLDE-SC yields with calculated in-target production rates
Authors:
S. Lukic,
F. Gevaert,
A. Kelic,
M. V. Ricciardi,
K. -H. Schmidt,
O. Yordanov
Abstract:
Recently, a series of dedicated inverse-kinematics experiments performed at GSI, Darmstadt, has brought an important progress in our understanding of proton and heavy-ion induced reactions at relativistic energies. The nuclear reaction code ABRABLA that has been developed and benchmarked against the results of these experiments has been used to calculate nuclide production cross sections at diff…
▽ More
Recently, a series of dedicated inverse-kinematics experiments performed at GSI, Darmstadt, has brought an important progress in our understanding of proton and heavy-ion induced reactions at relativistic energies. The nuclear reaction code ABRABLA that has been developed and benchmarked against the results of these experiments has been used to calculate nuclide production cross sections at different energies and with different targets and beams. These calculations are used to estimate nuclide production rates by protons in thick targets, taking into account the energy loss and the attenuation of the proton beam in the target, as well as the low-energy fission induced by the secondary neutrons. The results are compared to the yields of isotopes of various elements obtained from different targets at CERN-ISOLDE with 600 MeV protons, and the overall extraction efficiencies are deduced. The dependence of these extraction efficiencies on the nuclide half-life is found to follow a simple pattern in many different cases. A simple function is proposed to parameterize this behavior in a way that quantifies the essential properties of the extraction efficiency for the element and the target - ion-source system in question.
△ Less
Submitted 23 January, 2006;
originally announced January 2006.
-
Constraining the Kahler Moduli in the Heterotic Standard Model
Authors:
Tomas L. Gomez,
Sergio Lukic,
Ignacio Sols
Abstract:
Phenomenological implications of the volume of the Calabi-Yau threefolds on the hidden and observable M-theory boundaries, together with slope stability of their corresponding vector bundles, constrain the set of Kaehler moduli which give rise to realistic compactifications of the strongly coupled heterotic string. When vector bundles are constructed using extensions, we provide simple rules to…
▽ More
Phenomenological implications of the volume of the Calabi-Yau threefolds on the hidden and observable M-theory boundaries, together with slope stability of their corresponding vector bundles, constrain the set of Kaehler moduli which give rise to realistic compactifications of the strongly coupled heterotic string. When vector bundles are constructed using extensions, we provide simple rules to determine lower and upper bounds to the region of the Kaehler moduli space where such compactifications can exist. We show how small these regions can be, working out in full detail the case of the recently proposed Heterotic Standard Model. More explicitely, we exhibit Kaehler classes in these regions for which the visible vector bundle is stable. On the other hand, there is no polarization for which the hidden bundle is stable.
△ Less
Submitted 3 January, 2006; v1 submitted 16 December, 2005;
originally announced December 2005.