Demonstration of a Mobile Optical Clock Ensemble at Sea
Authors:
E. Ahern,
J. W. Allison,
C. Billington,
N. Bourbeau Hébert,
A. P. Hilton,
E. Klantsataya,
C. Locke,
A. N. Luiten,
M. Nelligan,
R. F. Offer,
C. Perrella,
S. K. Scholten,
B. White,
B. M. Sparkes,
R. Beard,
J. D. Elgin,
K. W. Martin
Abstract:
Atomic clocks have been at the leading edge of accuracy and precision since their inception in the 1950s. However, typically the most capable of these clocks have been confined to laboratories despite the fact that there are compelling reasons to apply them in the field and/or while in motion. These applications include synchronization of distributed critical infrastructure (e.g. data servers, com…
▽ More
Atomic clocks have been at the leading edge of accuracy and precision since their inception in the 1950s. However, typically the most capable of these clocks have been confined to laboratories despite the fact that there are compelling reasons to apply them in the field and/or while in motion. These applications include synchronization of distributed critical infrastructure (e.g. data servers, communications, electricity grids), scientific applications (e.g. radio-astronomy) and to mitigate the effects of interruption to Global Navigation Satellite Systems.
Over the last 20 years, there has been a breakthrough in the performance of atomic clocks by transitioning from an atomic reference based on a microwave transition to an optical frequency transition. The $10^5$-fold increase in reference frequency confers the potential for significantly higher performance. However, this performance increase has come at the cost of size, complexity and fragility which has continued the confinement of these clocks to the laboratory.
Here we report on a recent international collaboration where three emerging optical clocks, each operating on different principles, were trialed at sea. These clocks incorporate optical frequency combs so that their stable frequency outputs can be used directly in electronic apparatus and were also automated so that they do not require expert supervision. We present the frequency stability and reliability of these three clocks over multiple weeks of unsupervised naval trials, both in harbour and on the ocean. The performance of all three devices was orders of magnitude superior to existing best-in-class commercial solutions over short and medium timescales. This demonstrates that optical clocks are ready to deliver advantages for real-world applications.
△ Less
Submitted 21 June, 2024; v1 submitted 5 June, 2024;
originally announced June 2024.
-
Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell
Authors:
D. Hunter,
C. Perrella,
A. McWilliam,
J. P. McGilligan,
M. Mrozowski,
S. J. Ingleby,
P. F. Griffin,
D. Burt,
A. N. Luiten,
E. Riis
Abstract:
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusi…
▽ More
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N$_{2}$) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a $175\,μ$m probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43$\,\mathrm{pT/\sqrt{Hz}}$ within a Nyquist limited bandwidth of $500\,$Hz. Furthermore, the sensor's dynamic range exceeds the Earth's field of approximately $50\,μ$T, which provides a framework for magnetic field imaging in unshielded environments.
△ Less
Submitted 29 September, 2023; v1 submitted 20 March, 2023;
originally announced March 2023.
-
Experimental and theoretical study of dynamic polarizabilities in the $5S_{1/2}$-$5D_{5/2}$ clock transition in rubidium-87 and determination of E1 matrix elements
Authors:
Rhona Hamilton,
Benjamin M. Roberts,
Sarah K. Scholten,
Clayton Locke,
Andre N. Luiten,
Jacinda S. M. Ginges,
Christopher Perrella
Abstract:
The interaction between light and an atom causes perturbations in the atom's energy levels, known as the light-shift. These light-shifts are a key source of inaccuracy in atomic clocks, and can also deteriorate their precision. We present a study of light-shifts and associated dynamic polarizabilities for a two-photon atomic clock based on the $5S_{1/2}$-$5D_{5/2}$ transition in rubidium-87 over t…
▽ More
The interaction between light and an atom causes perturbations in the atom's energy levels, known as the light-shift. These light-shifts are a key source of inaccuracy in atomic clocks, and can also deteriorate their precision. We present a study of light-shifts and associated dynamic polarizabilities for a two-photon atomic clock based on the $5S_{1/2}$-$5D_{5/2}$ transition in rubidium-87 over the range 770 nm to 800 nm. We determine experimental and theoretical values for a magic wavelength in this range and the electric dipole (E1) matrix element for the $5P_{3/2}$-$5D_{5/2}$ transition. We find a magic wavelength of 776.179(5) nm (experimental) and 776.21 nm (theoretical) in the vicinity of the $5P_{3/2}$-$5D_{5/2}$ resonance, and the corresponding reduced E1 matrix element 1.80(6) $ea_0$ (experimental) and 1.96(15) $ea_0$ (theoretical). These values resolve a previous discrepancy between theory and experiment.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Wavefront Curvature in Optical Atomic Beam Clocks
Authors:
A. Strathearn,
R. F. Offer,
A. P. Hilton,
E. Klantsataya,
A. N. Luiten,
R. P. Anderson,
B. M. Sparkes,
T. M. Stace
Abstract:
Atomic clocks provide a reproducible basis for our understanding of time and frequency. Recent demonstrations of compact optical clocks, employing thermal atomic beams, have achieved short-term fractional frequency instabilities in the $10^{-16}$, competitive with the best international frequency standards available. However, a serious challenge inherent in compact clocks is the necessarily smalle…
▽ More
Atomic clocks provide a reproducible basis for our understanding of time and frequency. Recent demonstrations of compact optical clocks, employing thermal atomic beams, have achieved short-term fractional frequency instabilities in the $10^{-16}$, competitive with the best international frequency standards available. However, a serious challenge inherent in compact clocks is the necessarily smaller optical beams, which results in rapid variation in interrogating wavefronts. This can cause inhomogeneous excitation of the thermal beam leading to long term drifts in the output frequency. Here we develop a model for Ramsey-Bordé interferometery using optical fields with curved wavefronts and simulate the $^{40}$Ca beam clock experiment described in [Olson et al., Phys. Rev. Lett. 123, 073202 (2019)]. Olson et al.'s results had shown surprising and unexplained behaviour in the response of the atoms in the interrogation. Our model predicts signals consistent with experimental data and can account for the significant sensitivity to laser geometry that was reported. We find the signal-to-noise ratio is maximised when the laser is uncollimated at the interrogation zones to minimise inhomogeneity, and also identify an optimal waist size determined by both laser inhomogeneity and the velocity distribution of the atomic beam. We investigate the shifts and stability of the clock frequency, showing that the Gouy phase is the primary source of frequency variations arising from laser geometry.
△ Less
Submitted 24 January, 2023; v1 submitted 1 December, 2022;
originally announced December 2022.
-
Carrier-Envelope-Phase Dependent Strong-Field Excitation
Authors:
D. Chetty,
R. D. Glover,
X. M. Tong,
B. A. deHarak,
H. Xu,
N. Haram,
K. Bartschat,
A. J. Palmer,
A. N. Luiten,
P. S. Light,
I. V. Litvinyuk,
R. T. Sang
Abstract:
We present a joint experimental-theoretical study on the effect of the carrier-envelope phase (CEP) of a few-cycle pulse on the atomic excitation process. We focus on the excitation rates of argon as a function of CEP in the intensity range from 50-300 TW/cm$^2$, which covers the transition between the multiphoton and tunneling regimes. Through numerical simulations based on solving the time-depen…
▽ More
We present a joint experimental-theoretical study on the effect of the carrier-envelope phase (CEP) of a few-cycle pulse on the atomic excitation process. We focus on the excitation rates of argon as a function of CEP in the intensity range from 50-300 TW/cm$^2$, which covers the transition between the multiphoton and tunneling regimes. Through numerical simulations based on solving the time-dependent Schrödinger equation (TDSE), we show that the resulting bound-state population is highly sensitive to both the intensity and the CEP. Because the intensity varies over the interaction region, the CEP effect is considerably reduced in the experiment. Nevertheless, the data clearly agree with the theoretical prediction, and the results encourage the use of precisely tailored laser fields to coherently control the strong-field excitation process. We find a markedly different behavior for the CEP-dependent bound-state population at low and high intensities with a clear boundary, which we attribute to the transition from the multiphoton to the tunneling regime.
△ Less
Submitted 15 August, 2021;
originally announced August 2021.
-
Wide-bandwidth atomic magnetometry via instantaneous-phase retrieval
Authors:
Nathanial Wilson,
Christopher Perrella,
Russell Anderson,
André Luiten,
Philip Light
Abstract:
We develop and demonstrate a new protocol that allows sensing of magnetic fields in an extra-ordinary regime for atomic magnetometry. Until now, the demonstrated bandwidth for atomic magnetometry has been constrained to be slower than the natural precession of atomic spins in a magnetic field---the Larmor frequency. We demonstrate a new approach that tracks the instantaneous phase of atomic spins…
▽ More
We develop and demonstrate a new protocol that allows sensing of magnetic fields in an extra-ordinary regime for atomic magnetometry. Until now, the demonstrated bandwidth for atomic magnetometry has been constrained to be slower than the natural precession of atomic spins in a magnetic field---the Larmor frequency. We demonstrate a new approach that tracks the instantaneous phase of atomic spins to measure arbitrarily modulated magnetic fields with frequencies up to fifty times higher than the Larmor frequency. By accessing this regime, we demonstrate magnetic-field measurements across four decades in frequency up to 400 kHz, over three orders of magnitude wider than conventional atomic magnetometers. Furthermore, we demonstrate that our protocol can linearly detect transient fields 100--fold higher in amplitude than conventional methods. We highlight the bandwidth and dynamic range of the technique by measuring a magnetic field with a broad and dynamical spectrum.
△ Less
Submitted 10 March, 2020;
originally announced March 2020.
-
Observation of Dynamic Stark Resonances in Strong-Field Excitation
Authors:
Dashavir Chetty,
Rohan D. Glover,
Bruno A. deHarak,
Xiao-Min Tong,
Han Xu,
Tom Pauly,
Noah Smith,
Kathryn R. Hamilton,
Klaus Bartschat,
Joseph P. Ziegel,
Nicolas Douguet,
Andre N. Luiten,
Philip S. Light,
Igor V. Litvinyuk,
Robert T. Sang
Abstract:
We investigate AC Stark-shifted resonances in argon with ultrashort near-infrared pulses. Using 30 fs pulses we observe periodic enhancements of the excitation yield in the intensity regions corresponding to the absorption of 13 and 14 photons. By reducing the pulse duration to 6 fs with only a few optical cycles, we also demonstrate that the enhancements are significantly reduced beyond what is m…
▽ More
We investigate AC Stark-shifted resonances in argon with ultrashort near-infrared pulses. Using 30 fs pulses we observe periodic enhancements of the excitation yield in the intensity regions corresponding to the absorption of 13 and 14 photons. By reducing the pulse duration to 6 fs with only a few optical cycles, we also demonstrate that the enhancements are significantly reduced beyond what is measurable in the experiment. Comparing these to numerical predictions, which are in quantitative agreement with experimental results, we find that even though the quantum-state distribution can be broad, the enhancements are largely due to efficient population of a select few AC Stark-shifted resonant states rather than the closing of an ionization channel. Because these resonances are dependent on the frequency and intensity of the laser field, the broad bandwidth of the 6 fs pulses means that the resonance condition is fulfilled across a large range of intensities. This is further exaggerated by volume-averaging effects, resulting in excitation of the $5g$ state at almost all intensities and reducing the apparent magnitude of the enhancements. For 30 fs pulses, volume averaging also broadens the quantum state distribution but the enhancements are still large enough to survive. In this case, selectivity of excitation to a single state is reduced below 25% of the relative population. However, an analysis of TDSE simulations indicates that excitation of up to 60% into a single state is possible if volume averaging can be eliminated and the intensity can be precisely controlled.
△ Less
Submitted 2 April, 2020; v1 submitted 12 December, 2019;
originally announced December 2019.
-
Light-shift spectroscopy of optically trapped atomic ensembles
Authors:
Ashby P. Hilton,
Andre N. Luiten,
Philip S. Light
Abstract:
We develop a method for extracting the physical parameters of interest for a dipole trapped cold atomic ensemble. This technique uses the spatially dependent ac-Stark shift of the trap itself to project the atomic distribution onto a light-shift broadened transmission spectrum. We develop a model that connects the atomic distribution with the expected transmission spectrum. We then demonstrate the…
▽ More
We develop a method for extracting the physical parameters of interest for a dipole trapped cold atomic ensemble. This technique uses the spatially dependent ac-Stark shift of the trap itself to project the atomic distribution onto a light-shift broadened transmission spectrum. We develop a model that connects the atomic distribution with the expected transmission spectrum. We then demonstrate the utility of the technique by deriving the temperature, trap depth, lifetime, and trapped atom number from data that was taken in a single shot experimental measurement.
△ Less
Submitted 6 November, 2019;
originally announced November 2019.
-
Heterodyne fiber interferometer for frequency-noise reduction and rapid wide-band tunability of a conventional laser source
Authors:
Ashby P. Hilton,
Philip S. Light,
Lauris J. B. Talbot,
Andre N. Luiten
Abstract:
Self-heterodyne fiber interferometers have been shown to be capable of stabilizing lasers to ultra-narrow linewidths and present an excellent alternative to high finesse cavities for frequency stabilization. In addition to suppressing frequency noise, these devices are highly tunable, and can be manipulated to produce high speed frequency sweeps over the entire range of the laser. We present an an…
▽ More
Self-heterodyne fiber interferometers have been shown to be capable of stabilizing lasers to ultra-narrow linewidths and present an excellent alternative to high finesse cavities for frequency stabilization. In addition to suppressing frequency noise, these devices are highly tunable, and can be manipulated to produce high speed frequency sweeps over the entire range of the laser. We present an analytic approach for choosing a delay-line length for both optimal noise suppression and highest in-loop frequency sweep rate. Using this model we have implemented a fiber-based active Michelson interferometer as a frequency discriminator for a conventional diode laser and demonstrated a linewidth of 700 Hz over millisecond timescales. We also demonstrate a frequency scan rate of 1 THz/s and independently measure the maximum deviation in frequency from the linear sweep to be 100 kHz, predominantly limited by acoustic resonances in the apparatus.
△ Less
Submitted 5 September, 2019;
originally announced September 2019.
-
Dual-colour magic-wavelength trap for suppression of light shifts in atoms
Authors:
Ashby P. Hilton,
Christopher Perrella,
Andre N. Luiten,
Philip S. Light
Abstract:
We present an optical approach to compensating for spatially varying ac-Stark shifts that appear on atomic ensembles subject to strong optical control or trap** fields. The introduction of an additional weak light field produces an intentional perturbation between atomic states that is tuned to suppress the influence of the strong field. The compensation field suppresses sensitivity in one of th…
▽ More
We present an optical approach to compensating for spatially varying ac-Stark shifts that appear on atomic ensembles subject to strong optical control or trap** fields. The introduction of an additional weak light field produces an intentional perturbation between atomic states that is tuned to suppress the influence of the strong field. The compensation field suppresses sensitivity in one of the transition frequencies of the trapped atoms to both the atomic distribution and motion. We demonstrate this technique in a cold rubidium ensemble and show a reduction in inhomogeneous broadening in the trap. This two-colour approach emulates the magic trap** approach that is used in modern atomic lattice clocks but provides greater flexibility in choice of atomic species, probe transition, and trap wavelength.
△ Less
Submitted 11 November, 2018;
originally announced November 2018.
-
Laser-based metastable krypton generation
Authors:
M. A. Dakka,
G. Tsiminis,
P. S. Light,
R. D. Glover,
C. Perrella,
J. Moffatt,
N. A. Spooner,
R. T. Sang,
A. N. Luiten
Abstract:
We demonstrate the generation of metastable krypton in the long-lived 1s5 state using laser excitation. The atoms are excited through a two-photon absorption process into the 2p6 state using a pulsed optical parametric oscillator laser operating near 215 nm, after which the atoms decay quickly into the metastable state with a branching ratio of 75 %. The interaction dynamics are modeled using dens…
▽ More
We demonstrate the generation of metastable krypton in the long-lived 1s5 state using laser excitation. The atoms are excited through a two-photon absorption process into the 2p6 state using a pulsed optical parametric oscillator laser operating near 215 nm, after which the atoms decay quickly into the metastable state with a branching ratio of 75 %. The interaction dynamics are modeled using density matrix formalism and, by combining this with experimental observations, we are able to calculate photo-ionization and two-photon absorption cross-sections. When compared to traditional approaches to metastable production, this new approach shows great potential for high-density metastable krypton production with minimal heating of the sample. Here, we show metastable production efficiencies of up to 2% per pulse. The new experimental results gained here, when combined with the density matrix model we have developed, suggest that fractional efficiencies up to 30% are possible under optimal conditions.
△ Less
Submitted 11 August, 2018; v1 submitted 15 May, 2018;
originally announced May 2018.
-
High-efficiency cold-atom transport into a waveguide trap
Authors:
Ashby P. Hilton,
Christopher Perrella,
Fetah Benabid,
Ben M. Sparkes,
Andre N. Luiten,
Philip S. Light
Abstract:
We have developed and characterized an atom-guiding technique that loads $3\times10^6$ cold rubidium atoms into hollow-core optical fibre, an order-of-magnitude larger than previously reported results. This result was possible because it was guided by a physically realistic simulation that could provide the specifications for loading efficiencies of 3% and a peak optical depth of 600. The simulati…
▽ More
We have developed and characterized an atom-guiding technique that loads $3\times10^6$ cold rubidium atoms into hollow-core optical fibre, an order-of-magnitude larger than previously reported results. This result was possible because it was guided by a physically realistic simulation that could provide the specifications for loading efficiencies of 3% and a peak optical depth of 600. The simulation further showed that the demonstrated loading efficiency is limited solely by the geometric overlap of the atom cloud and the optical guide beam, and is thus open to further improvement with experimental modification. The experimental arrangement allows observation of the real-time effects of light-assisted cold atom collisions and background gas collisions by tracking the dynamics of the cold atom cloud as it falls into the fibre. The combination of these observations, and physical understanding from the simulation, allows estimation of the limits to loading cold atoms into hollow-core fibres.
△ Less
Submitted 30 October, 2018; v1 submitted 14 February, 2018;
originally announced February 2018.
-
Drift-compensated Low-noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1
Authors:
Myoung-Sun Heo,
Sang Eon Park,
Won-Kyu Lee,
Sang-Bum Lee,
Hyun-Gue Hong,
Taeg Yong Kwon,
Chang Yong Park,
Dai-Hyuk Yu,
G. Santarelli,
Ashby Hilton,
Andre N. Luiten,
John G. Hartnett
Abstract:
In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency c…
▽ More
In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency comb locked to an ultra-stable laser, is better than $5\times10^{-15}$ at an averaging time of 1 s. We demonstrate that the short-term stability of the synthesizer is lower than the quantum projection noise limit of the Cs fountain clock, KRISS-F1(Cs) by measuring the short-term stability of the fountain with varying trapped atom number. The stability of the fountain at 1-s averaging time reaches $2.5\times10^{-14}$ at the highest atom number in the experiment when the synthesizer is used as an interrogation oscillator of the fountain. In order to compensate the frequency drift of the CSO, the output frequency of a waveform generator in the synthesis chain is ramped linearly. By doing this, the stability of the synthesizer at an average time of one hour reaches a level of $10^{-16}$ which is measured with the fountain clock.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Analysis of 3D-printed metal for rapid-prototyped reflective terahertz optics
Authors:
Daniel Headland,
Withawat Withayachumnankul,
Michael Webb,
Heike Ebendorff-Heidepriem,
Andre Luiten,
Derek Abbott
Abstract:
We explore the potential of 3D metal printing to realize complex conductive terahertz devices. Factors impacting performance such as printing resolution, surface roughness, oxidation, and material loss are investigated via analytical, numerical, and experimental approaches. The high degree of control offered by a 3D-printed topology is exploited to realize a zone plate operating at 530 GHz. Reflec…
▽ More
We explore the potential of 3D metal printing to realize complex conductive terahertz devices. Factors impacting performance such as printing resolution, surface roughness, oxidation, and material loss are investigated via analytical, numerical, and experimental approaches. The high degree of control offered by a 3D-printed topology is exploited to realize a zone plate operating at 530 GHz. Reflection efficiency at this frequency is found to be over 90%. The high-performance of this preliminary device suggest that 3D metal printing can play a strong role in guided-wave and general beam control devices in the terahertz range.
△ Less
Submitted 10 May, 2016;
originally announced May 2016.
-
Fast machine-learning online optimization of ultra-cold-atom experiments
Authors:
P. B. Wigley,
P. J. Everitt,
A. van den Hengel,
J. W. Bastian,
M. A. Sooriyabandara,
G. D. McDonald,
K. S. Hardman,
C. D. Quinlivan,
P. Manju,
C. C. N. Kuhn,
I. R. Petersen,
A. Luiten,
J. J. Hope,
N. P. Robins,
M. R. Hush
Abstract:
Machine-designed control of complex devices or experiments can discover strategies superior to those developed via simplified models. We describe an online optimization algorithm based on Gaussian processes and apply it to optimization of the production of Bose-Einstein condensates (BEC). BEC is typically created with an exponential evaporation ramp that is approximately optimal for s-wave, ergodi…
▽ More
Machine-designed control of complex devices or experiments can discover strategies superior to those developed via simplified models. We describe an online optimization algorithm based on Gaussian processes and apply it to optimization of the production of Bose-Einstein condensates (BEC). BEC is typically created with an exponential evaporation ramp that is approximately optimal for s-wave, ergodic dynamics with two-body interactions and no other loss rates, but likely sub-optimal for many real experiments. Machine learning using a Gaussian process, in contrast, develops a statistical model of the relationship between the parameters it controls and the quality of the BEC produced. This is an online process, and an active one, as the Gaussian process model updates on the basis of each subsequent experiment and proposes a new set of parameters as a result. We demonstrate that the Gaussian process machine learner is able to discover a ramp that produces high quality BECs in 10 times fewer iterations than a previously used online optimization technique. Furthermore, we show the internal model developed can be used to determine which parameters are essential in BEC creation and which are unimportant, providing insight into the optimization process.
△ Less
Submitted 20 July, 2015; v1 submitted 17 July, 2015;
originally announced July 2015.
-
Quantum-Limited Spectroscopy
Authors:
Gar-Wing Truong,
James D. Anstie,
Eric F. May,
Thomas M. Stace,
Andre N. Luiten
Abstract:
Spectroscopy has an illustrious history delivering serendipitous discoveries and providing a stringent testbed for new physical predictions, including applications from trace materials detection, to understanding the atmospheres of stars and planets, and even constraining cosmological models. Reaching fundamental-noise limits permits optimal extraction of spectroscopic information from an absorpti…
▽ More
Spectroscopy has an illustrious history delivering serendipitous discoveries and providing a stringent testbed for new physical predictions, including applications from trace materials detection, to understanding the atmospheres of stars and planets, and even constraining cosmological models. Reaching fundamental-noise limits permits optimal extraction of spectroscopic information from an absorption measurement. Here we demonstrate a quantum-limited spectrometer that delivers high-precision measurements of the absorption lineshape. These measurements yield a ten-fold improvement in the accuracy of the excited-state (6P$_{1/2}$) hyperfine splitting in Cs, and reveals a breakdown in the well-known Voigt spectral profile. We develop a theoretical model that accounts for this breakdown, explaining the observations to within the shot-noise limit. Our model enables us to infer the thermal velocity-dispersion of the Cs vapour with an uncertainty of 35ppm within an hour. This allows us to determine a value for Boltzmann's constant with a precision of 6ppm, and an uncertainty of 71ppm.
△ Less
Submitted 2 January, 2015;
originally announced January 2015.
-
Nano-Kelvin thermometry and temperature control: beyond the thermal noise limit
Authors:
Wenle Weng,
James D. Anstie,
Thomas M. Stace,
Geoff Campbell,
Fred N. Baynes,
Andre N. Luiten
Abstract:
We demonstrate thermometry with a resolution of 80 $\mathrm{nK} / \sqrt{\mathrm{Hz}}$ using an isotropic crystalline whispering-gallery mode resonator based on a dichroic dual-mode technique. We simultaneously excite two modes that have a mode frequency ratio very close to two ($\pm0.3$ppm). The wavelength- and temperature-dependence of the refractive index means that the frequency difference betw…
▽ More
We demonstrate thermometry with a resolution of 80 $\mathrm{nK} / \sqrt{\mathrm{Hz}}$ using an isotropic crystalline whispering-gallery mode resonator based on a dichroic dual-mode technique. We simultaneously excite two modes that have a mode frequency ratio very close to two ($\pm0.3$ppm). The wavelength- and temperature-dependence of the refractive index means that the frequency difference between these modes is an ultra-sensitive proxy of the resonator temperature. This approach to temperature sensing automatically suppresses sensitivity to thermal expansion and vibrationally induced changes of the resonator. We also demonstrate active suppression of temperature fluctuations in the resonator by controlling the intensity of the driving laser. The residual temperature fluctuations are shown to be below the limits set by fundamental thermodynamic fluctuations of the resonator material.
△ Less
Submitted 29 March, 2014;
originally announced March 2014.
-
IR-stimulated visible fluorescence in pink and brown diamond
Authors:
K S Byrne,
J G Chapman,
A N Luiten
Abstract:
Irradiation of natural pink and brown diamond by middle-ultraviolet light (photon energy > 4.1 eV) is seen to induce anomalous fluorescence phenomena at N3 defect centres (structure N3-V). When diamonds primed in this fashion are subsequently exposed to infrared light (even with a delay of many hours), a transient burst of blue N3 fluorescence is observed. The dependence of this IR-triggered fluor…
▽ More
Irradiation of natural pink and brown diamond by middle-ultraviolet light (photon energy > 4.1 eV) is seen to induce anomalous fluorescence phenomena at N3 defect centres (structure N3-V). When diamonds primed in this fashion are subsequently exposed to infrared light (even with a delay of many hours), a transient burst of blue N3 fluorescence is observed. The dependence of this IR-triggered fluorescence on pump wavelength and intensity suggest that this fluorescence phenomena is intrinsically related to pink diamond photochromism. An energy transfer process between N3 defects and other defect species can account for both the UV-induced fluorescence intensity changes, and the apparent optical upconversion of IR light. From this standpoint, we consider the implications of this N3 fluorescence behaviour for the current understanding of pink diamond photochromism kinetics.
△ Less
Submitted 19 December, 2013;
originally announced December 2013.
-
High-Effciency Cross-Phase Modulation in a Gas-Filled Waveguide
Authors:
C. Perrella,
P. S. Light,
J. D. Anstie,
F. Benabid,
T. M. Stace,
A. G. White,
A. N. Luiten
Abstract:
Strong cross-Kerr non-linearities have been long sought after for quantum information applications. Recent work has shown that they are intrinsically unreliable in travelling wave configurations: cavity configurations avoid this, but require knowledge of both the non-linearity and the loss. Here we present a detailed systematic study of cross-phase modulation, and absorption, in a rubidium vapour…
▽ More
Strong cross-Kerr non-linearities have been long sought after for quantum information applications. Recent work has shown that they are intrinsically unreliable in travelling wave configurations: cavity configurations avoid this, but require knowledge of both the non-linearity and the loss. Here we present a detailed systematic study of cross-phase modulation, and absorption, in a rubidium vapour confined within a hollow-core photonic crystal fibre. Using a two-photon transition, we observe phase modulations of up to $π$rad with a signal power of 25$μ$W, corresponding to a non-linear Kerr coefficient, $n_2$, of $0.8 \times 10^{-6}$ cm$^2$/W, or $1.3 \times 10^{-6}$ rad per photon.
△ Less
Submitted 18 June, 2013;
originally announced June 2013.
-
Linewidth of collimated wavelength-converted emission in Rb vapours
Authors:
Alexander Akulshin,
Christopher Perrella,
Gar-Wing Truong,
Andre Luiten,
Dmitry Budker,
Russell McLean
Abstract:
We present a study of the spectral linewidth of collimated blue light (CBL) that results from wave mixing of low-power cw laser radiation at 780 nm and 776 nm and an internally-generated mid-IR field at 5.23 um in Rb vapour. Using a high-finesse Fabry-Perot interferometer the spectral width of the CBL is found to be less than 1.3 MHz for a wide range of experimental conditions. We demonstrate that…
▽ More
We present a study of the spectral linewidth of collimated blue light (CBL) that results from wave mixing of low-power cw laser radiation at 780 nm and 776 nm and an internally-generated mid-IR field at 5.23 um in Rb vapour. Using a high-finesse Fabry-Perot interferometer the spectral width of the CBL is found to be less than 1.3 MHz for a wide range of experimental conditions. We demonstrate that the CBL linewidth is mainly limited by the temporal coherence of the applied laser fields rather than the atom-light interaction itself. Results obtained with frequency modulated laser light allow an upper limit of several hundred kHz to be set for the linewidth of the collimated mid-IR radiation at 5.23 um, which has not been directly detected.
△ Less
Submitted 9 October, 2013; v1 submitted 29 January, 2013;
originally announced January 2013.
-
Frequency evaluation of collimated blue light generated by wave mixing in Rb vapour
Authors:
Alexander Akulshin,
Christopher Perrella,
Gar-Wing Truong,
Russell McLean,
Andre Luiten
Abstract:
An evaluation of the absolute frequency and tunability of collimated blue light (CBL) generated in warm Rb vapour excited by low-power cw laser radiation at 780 nm and 776 nm, has been performed using a Fabry-Perot interferometer and a blue diode laser. For the conditions of our experiments the CBL tuning range is more than 100 MHz around the resonant frequency of the 85Rb 5S1/2 (F=3) to 6P3/2 (F'…
▽ More
An evaluation of the absolute frequency and tunability of collimated blue light (CBL) generated in warm Rb vapour excited by low-power cw laser radiation at 780 nm and 776 nm, has been performed using a Fabry-Perot interferometer and a blue diode laser. For the conditions of our experiments the CBL tuning range is more than 100 MHz around the resonant frequency of the 85Rb 5S1/2 (F=3) to 6P3/2 (F'=4) transition. A simple technique for stabilizing the power and frequency of the CBL to within a few percent and 10 MHz, respectively, is suggested and demonstrated.
△ Less
Submitted 20 July, 2012;
originally announced July 2012.
-
Saturation Spectroscopy of Iodine in Hollow-core Optical Fibre
Authors:
Anna Lurie,
Philip S. Light,
James Anstie,
Thomas M. Stace,
Paul C. Abbott,
Fetah Benabid,
Andre N. Luiten
Abstract:
We present high-resolution spectroscopy of Iodine vapour that is loaded and trapped within the core of a hollow-core photonic crystal fibre (HC-PCF). We compare the observed spectroscopic features to those seen in a conventional iodine cell and show that the saturation characteristics differ significantly. Despite the confined geometry it was still possible to obtain sub-Doppler features with a sp…
▽ More
We present high-resolution spectroscopy of Iodine vapour that is loaded and trapped within the core of a hollow-core photonic crystal fibre (HC-PCF). We compare the observed spectroscopic features to those seen in a conventional iodine cell and show that the saturation characteristics differ significantly. Despite the confined geometry it was still possible to obtain sub-Doppler features with a spectral width of ~6 MHz with very high contrast. We provide a simple theory which closely reproduces all the key observations of the experiment.
△ Less
Submitted 15 March, 2012;
originally announced March 2012.
-
Spectral Lineshape Measurements with Shot-Noise Limited Accuracy
Authors:
Gar-Wing Truong,
James D. Anstie,
Eric F. May,
Thomas M. Stace,
Andre N. Luiten
Abstract:
Spectroscopy has played the key role in revealing, and thereby understanding, the structure of atoms and molecules. A central drive in this field is the pursuit of higher precision and accuracy so that ever more subtle effects might be discovered. Here, we report on laser absorption spectroscopy that operates at the conventional quantum limit imposed by photon shot-noise. Furthermore, we achieve t…
▽ More
Spectroscopy has played the key role in revealing, and thereby understanding, the structure of atoms and molecules. A central drive in this field is the pursuit of higher precision and accuracy so that ever more subtle effects might be discovered. Here, we report on laser absorption spectroscopy that operates at the conventional quantum limit imposed by photon shot-noise. Furthermore, we achieve this limit without compromising the accuracy of the measurement. We demonstrate these properties by recording an absorption profile of cesium vapor at the 2 parts-per-million level. The extremely high signal-to-noise ratio allows us to directly observe the homogeneous lineshape component of the spectral profile, even while in the presence of Doppler broadening that is a factor of 100 times wider. We can do this because we can precisely measure the spectral profile at a frequency detuning more than 200 natural linewidths from the line center. We use the power of this tool to demonstrate direct measurements of a low-intensity optically-induced broadening process that is quite distinct from the well-known power broadening phenomenon.
△ Less
Submitted 15 March, 2012;
originally announced March 2012.
-
Power Dependent Lineshape Corrections for Quantitative Spectroscopy
Authors:
Thomas M. Stace,
Gar-Wing Truong,
James Anstie,
Eric F. May,
Andre N. Luiten
Abstract:
The Voigt profile - a convolution of a Gaussian and a Lorentzian - accurately describes the absorption lines of atomic and molecular gases at low probe powers. Fitting such to experimental spectra yields both the Lorentzian natural linewidth and the Gaussian Doppler broadening. However, as the probe power increases saturation effects introduce spurious power dependence into the fitted Doppler widt…
▽ More
The Voigt profile - a convolution of a Gaussian and a Lorentzian - accurately describes the absorption lines of atomic and molecular gases at low probe powers. Fitting such to experimental spectra yields both the Lorentzian natural linewidth and the Gaussian Doppler broadening. However, as the probe power increases saturation effects introduce spurious power dependence into the fitted Doppler width. Using a simple atomic model, we calculate power-dependent corrections to the Voigt profile, which are parametrized by the Gaussian Doppler width, the Lorentzian natural linewidth, and the optical depth. We show numerically and experimentally that including the correction term substantially reduces the spurious power dependence in the fitted Gaussian width.
△ Less
Submitted 13 March, 2012;
originally announced March 2012.
-
Laser frequency comb techniques for precise astronomical spectroscopy
Authors:
Michael T. Murphy,
Clayton R. Locke,
Philip S. Light,
Andre N. Luiten,
Jon S. Lawrence
Abstract:
Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but fu…
▽ More
Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but future experiments requiring velocity precisions approaching ~1 cm/s will be more strongly affected. Laser frequency combs have been shown to provide highly precise wavelength calibration for astronomical spectrographs, but here we show that they can also be used to measure IPS variations in astronomical CCDs in situ. We successfully tested a laser frequency comb system on the Ultra-High Resolution Facility spectrograph at the Anglo-Australian Telescope. By modelling the 2-dimensional comb signal recorded in a single CCD exposure, we find that the average IPS deviates by <8 per cent if it is assumed to vary symmetrically about the pixel centre. We also demonstrate that series of comb exposures with absolutely known offsets between them can yield tighter constraints on symmetric IPS variations from ~100 pixels. We discuss measurement of asymmetric IPS variations and absolute wavelength calibration of astronomical spectrographs and CCDs using frequency combs.
△ Less
Submitted 3 February, 2012;
originally announced February 2012.
-
Testing Lorentz Invariance Using an Odd-Parity Asymmetric Optical Resonator
Authors:
Fred Baynes,
Andre Luiten,
Michael Tobar
Abstract:
We present the first experimental test of Lorentz invariance using the frequency difference between counter-propagating modes in an asymmetric odd-parity optical resonator. This type of test is $\sim10^{4}$ more sensitive to odd-parity and isotropic (scalar) violations of Lorentz invariance than equivalent conventional even-parity experiments due to the asymmetry of the optical resonator. The disa…
▽ More
We present the first experimental test of Lorentz invariance using the frequency difference between counter-propagating modes in an asymmetric odd-parity optical resonator. This type of test is $\sim10^{4}$ more sensitive to odd-parity and isotropic (scalar) violations of Lorentz invariance than equivalent conventional even-parity experiments due to the asymmetry of the optical resonator. The disadvantages of odd parity resonators have been negated by the use of counter-propagating modes, delivering a high level of immunity to environmental fluctuations. With a non-rotating experiment our result limits the isotropic Lorentz violating parameter $\tildeκ_{tr}$ to 3.4 $\pm$ 6.2 x $10^{-9}$, the best reported constraint from direct measurements. Using this technique the bounds on odd-parity and scalar violations of Lorentz invariance can be improved by many orders of magnitude.
△ Less
Submitted 27 August, 2011;
originally announced August 2011.
-
Optimized coupling of cold atoms into a fiber using a blue-detuned hollow-beam funnel
Authors:
Jerome Poulin,
Philip S. Light,
Raman Kashyap,
Andre N. Luiten
Abstract:
We theoretically investigate the process of coupling cold atoms into the core of a hollow-core photonic-crystal optical fiber using a blue-detuned Laguerre-Gaussian beam. In contrast to the use of a red-detuned Gaussian beam to couple the atoms, the blue-detuned hollow-beam can confine cold atoms to the darkest regions of the beam thereby minimizing shifts in the internal states and making the gui…
▽ More
We theoretically investigate the process of coupling cold atoms into the core of a hollow-core photonic-crystal optical fiber using a blue-detuned Laguerre-Gaussian beam. In contrast to the use of a red-detuned Gaussian beam to couple the atoms, the blue-detuned hollow-beam can confine cold atoms to the darkest regions of the beam thereby minimizing shifts in the internal states and making the guide highly robust to heating effects. This single optical beam is used as both a funnel and guide to maximize the number of atoms into the fiber. In the proposed experiment, Rb atoms are loaded into a magneto-optical trap (MOT) above a vertically-oriented optical fiber. We observe a gravito-optical trap** effect for atoms with high orbital momentum around the trap axis, which prevents atoms from coupling to the fiber: these atoms lack the kinetic energy to escape the potential and are thus trapped in the laser funnel indefinitely. We find that by reducing the dipolar force to the point at which the trap** effect just vanishes, it is possible to optimize the coupling of atoms into the fiber. Our simulations predict that by using a low-power (2.5 mW) and far-detuned (300 GHz) Laguerre-Gaussian beam with a 20-μm radius core hollow-fiber it is possible to couple 11% of the atoms from a MOT 9 mm away from the fiber. When MOT is positioned further away, coupling efficiencies over 50% can be achieved with larger core fibers.
△ Less
Submitted 24 July, 2011;
originally announced July 2011.
-
An Optical Fibre Pulse Rate Multiplier for Ultra-low Phase-noise Signal Generation
Authors:
A. Haboucha,
W. Zhang,
T. Li,
M Lours,
A. N. Luiten,
Y. Le Coq,
G. Santarelli
Abstract:
In this letter we report on an all optical-fibre approach to the synthesis of ultra-low noise microwave signals by photodetection of femtosecond laser pulses. We use a cascade of Mach-Zehnder fibre interferometers to realize stable and efficient repetition rate multiplication. This technique increases the signal level of the photodetected microwave signal by close to 18 dB, that in turn, allows us…
▽ More
In this letter we report on an all optical-fibre approach to the synthesis of ultra-low noise microwave signals by photodetection of femtosecond laser pulses. We use a cascade of Mach-Zehnder fibre interferometers to realize stable and efficient repetition rate multiplication. This technique increases the signal level of the photodetected microwave signal by close to 18 dB, that in turn, allows us to demonstrate a phase noise level of 118 dBc/Hz at 1 Hz and -160 dBc/Hz at 10 MHz from 12 GHz signal. The noise floor of the fiber multiplier and photodetection system alone is around -164 dBc/Hz at the same offset frequency, which is very close to the fundamental shot noise floor
△ Less
Submitted 26 August, 2011; v1 submitted 26 June, 2011;
originally announced June 2011.
-
Advanced noise reduction techniques for ultra-low phase noise optical-to-microwave division with femtosecond fiber combs
Authors:
W. Zhang,
Z. Xu,
M. Lours,
R. Boudot,
Y. Kersale,
A. N. Luiten,
Y. Le Coq,
G. Santarelli
Abstract:
We report what we believe to be the lowest phase noise optical-to-microwave frequency division using fiber-based femtosecond optical frequency combs: a residual phase noise of -120dBc/Hz at 1 Hz offset from a 11.55GHz carrier frequency. We furthermore report a detailed investigation into the fundamental noise sources which afflicts the division process itself. Two frequency combs with quasi-identi…
▽ More
We report what we believe to be the lowest phase noise optical-to-microwave frequency division using fiber-based femtosecond optical frequency combs: a residual phase noise of -120dBc/Hz at 1 Hz offset from a 11.55GHz carrier frequency. We furthermore report a detailed investigation into the fundamental noise sources which afflicts the division process itself. Two frequency combs with quasi-identical configurations are referenced to a common ultrastable cavity laser source. To identify each of the limiting effects we implement an ultra-low noise carrier-suppression measurement system, which circumvents the detection and amplification noise of more conventional techniques. This technique now allows the suppression of these unwanted sources of noise to very low levels. In the Fourier frequency range of ~200 Hz to 100 kHz, a fed-forward technique based on a voltage-controlled phase shifter delivers a further noise reduction of 10 dB. For lower Fourier frequencies, optical power stabilization is implemented in order to reduce the relative intensity noise which causes unwanted phase noise through power to phase conversion in the detector. We implement and compare two possible control schemes based on an acousto-optical modulator and comb pump current. We also present wideband measurements on the relative intensity noise of the fiber comb.
△ Less
Submitted 9 March, 2011; v1 submitted 3 December, 2010;
originally announced December 2010.
-
Quantitative atomic spectroscopy for primary thermometry
Authors:
Gar-Wing Truong,
Eric F. May,
Thomas M. Stace,
Andre N. Luiten
Abstract:
Quantitative spectroscopy has been used to measure accurately the Doppler-broadening of atomic transitions in $^{85}$Rb vapor. By using a conventional platinum resistance thermometer and the Doppler thermometry technique, we were able to determine $k_B$ with a relative uncertainty of $4.1\times 10^{-4}$, and with a deviation of $2.7\times 10^{-4}$ from the expected value. Our experiment, using an…
▽ More
Quantitative spectroscopy has been used to measure accurately the Doppler-broadening of atomic transitions in $^{85}$Rb vapor. By using a conventional platinum resistance thermometer and the Doppler thermometry technique, we were able to determine $k_B$ with a relative uncertainty of $4.1\times 10^{-4}$, and with a deviation of $2.7\times 10^{-4}$ from the expected value. Our experiment, using an effusive vapour, departs significantly from other Doppler-broadened thermometry (DBT) techniques, which rely on weakly absorbing molecules in a diffusive regime. In these circumstances, very different systematic effects such as magnetic sensitivity and optical pum** are dominant. Using the model developed recently by Stace and Luiten, we estimate the perturbation due to optical pum** of the measured $k_B$ value was less than $4\times 10^{-6}$. The effects of optical pum** on atomic and molecular DBT experiments is mapped over a wide range of beam size and saturation intensity, indicating possible avenues for improvement. We also compare the line-broadening mechanisms, windows of operation and detection limits of some recent DBT experiments.
△ Less
Submitted 13 January, 2011; v1 submitted 31 August, 2010;
originally announced August 2010.
-
Colloquium: Comparison of Astrophysical and Terrestrial Frequency Standards
Authors:
John G. Hartnett,
Andre Luiten
Abstract:
We have re-analyzed the stability of pulse arrival times from pulsars and white dwarfs using several analysis tools for measuring the noise characteristics of sampled time and frequency data. We show that the best terrestrial artificial clocks substantially exceed the performance of astronomical sources as time-keepers in terms of accuracy (as defined by cesium primary frequency standards) and sta…
▽ More
We have re-analyzed the stability of pulse arrival times from pulsars and white dwarfs using several analysis tools for measuring the noise characteristics of sampled time and frequency data. We show that the best terrestrial artificial clocks substantially exceed the performance of astronomical sources as time-keepers in terms of accuracy (as defined by cesium primary frequency standards) and stability. This superiority in stability can be directly demonstrated over time periods up to two years, where there is high quality data for both. Beyond 2 years there is a deficiency of data for clock/clock comparisons and both terrestrial and astronomical clocks show equal performance being equally limited by the quality of the reference timescales used to make the comparisons. Nonetheless, we show that detailed accuracy evaluations of modern terrestrial clocks imply that these new clocks are likely to have a stability better than any astronomical source up to comparison times of at least hundreds of years. This article is intended to provide a correct appreciation of the relative merits of natural and artificial clocks. The use of natural clocks as tests of physics under the most extreme conditions is entirely appropriate; however, the contention that these natural clocks, particularly white dwarfs, can compete as timekeepers against devices constructed by mankind is shown to be doubtful.
△ Less
Submitted 15 November, 2010; v1 submitted 1 April, 2010;
originally announced April 2010.
-
Ultra-Low Noise Microwave Extraction from Fiber-Based Optical Frequency Comb
Authors:
J. Millo,
R. Boudot,
M. Lours,
P. Y. Bourgeois,
A. N. Luiten,
Y. Le Coq,
Y. Kersale,
G. Santarelli
Abstract:
In this letter, we report on all-optical fiber approach to the generation of ultra-low noise microwave signals. We make use of two erbium fiber mode-locked lasers phase locked to a common ultra-stable laser source to generate an 11.55 GHz signal with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz from the carrier.The residual frequency instability of the microwave signals derived f…
▽ More
In this letter, we report on all-optical fiber approach to the generation of ultra-low noise microwave signals. We make use of two erbium fiber mode-locked lasers phase locked to a common ultra-stable laser source to generate an 11.55 GHz signal with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz from the carrier.The residual frequency instability of the microwave signals derived from the two optical frequency combs is below 2.3 10^(-16) at 1s and about 4 10^(-19) at 6.5 10^(4)s (in 5 Hz bandwidth, three days continuous operation).
△ Less
Submitted 21 November, 2009; v1 submitted 25 June, 2009;
originally announced June 2009.
-
Long Term Operation and Performance of Cryogenic Sapphire Oscillators
Authors:
M. E. Tobar,
E. N. Ivanov,
C. R. Locke,
P. L. Stanwix,
J. G. Hartnett,
A. N. Luiten,
R. B. Warrington,
P. T. H. Fisk,
M. A. Lawn,
M. J. Wouters,
S. Bize,
G. Santarelli,
P. Wolf,
A. Clairon,
P. Guillemot
Abstract:
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive…
▽ More
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.
△ Less
Submitted 19 August, 2006;
originally announced August 2006.
-
Long-distance frequency dissemination with a resolution of 10-17
Authors:
Christophe Daussy,
Olivier Lopez,
Anne Amy-Klein,
Andréi N. Goncharov,
Mickael Guinet,
Christian Chardonnet,
François Narbonneau,
Michel Lours,
Damien Chambon,
Sébastien Bize,
André Clairon,
Georgio Santarelli,
Mike E. Tobar,
Andre N. Luiten
Abstract:
We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10-17 for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond l…
▽ More
We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10-17 for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3.10-14 at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1.10-14 at 1 s.
△ Less
Submitted 17 June, 2005;
originally announced June 2005.
-
Recent Experimental Tests of Special Relativity
Authors:
Peter Wolf,
Sebastien Bize,
Michael E. Tobar,
Frederic Chapelet,
Andre Clairon,
Andre N. Luiten,
Giorgio Santarelli
Abstract:
We review our recent Michelson-Morley (MM) and Kennedy-Thorndike (KT) experiment, which tests Lorentz invariance in the photon sector, and report first results of our ongoing atomic clock test of Lorentz invariance in the matter sector. The MM-KT experiment compares a cryogenic microwave resonator to a hydrogen maser, and has set the most stringent limit on a number of parameters in alternative…
▽ More
We review our recent Michelson-Morley (MM) and Kennedy-Thorndike (KT) experiment, which tests Lorentz invariance in the photon sector, and report first results of our ongoing atomic clock test of Lorentz invariance in the matter sector. The MM-KT experiment compares a cryogenic microwave resonator to a hydrogen maser, and has set the most stringent limit on a number of parameters in alternative theories to special relativity. We also report first results of a test of Lorentz invariance in the SME (Standard Model Extension) matter sector, using Zeeman transitions in a laser cooled Cs atomic fountain clock. We describe the experiment together with the theoretical model and analysis. Recent experimental results are presented and we give a first estimate of components of the $\tilde{c}^p$ parameters of the SME matter sector. A full analysis of systematic effects is still in progress, and will be the subject of a future publication together with our final results. If confirmed, the present limits would correspond to first ever measurements of some $\tilde{c}^p$ components, and improvements by 11 and 14 orders of magnitude on others.
△ Less
Submitted 21 June, 2005;
originally announced June 2005.
-
Cold atom Clocks and Applications
Authors:
S. Bize,
P. Laurent,
M. Abgrall,
H. Marion,
I. Maksimovic,
L. Cacciapuoti,
J. Gruenert,
C. Vian,
F. Pereira dos Santos,
P. Rosenbusch,
P. Lemonde,
G. Santarelli,
P. Wolf,
A. Clairon,
A. Luiten,
M. Tobar,
C. Salomon
Abstract:
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time…
▽ More
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of $2\times 10^{-16}$ at $50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of $7\times 10^{-16}$, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using $^{87}$Rb and $^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.
△ Less
Submitted 22 February, 2005;
originally announced February 2005.
-
First observation of feshbach resonances at very low magnetic field in a 133Cs fountain
Authors:
H. Marion,
S. Bize,
L. Cacciapuoti,
D. Chambon,
F. Pereira Dos Santos,
G. Santarelli,
P. Wolf,
A. Clairon,
A. Luiten,
M. Tobar,
S. Kokkelmans,
C. Salomon
Abstract:
One of the main limitations of cesium atomic fountains has been the cold collision frequency shift. By using a method based on a transfer of population by adiabatic passage allowing to prepare cold atomic samples with a well defined ratio of atomic density as well as atom number the collisional shift is controlled at the 10E-3 of its value. A calibration of Zeeman sub-states contribution to the…
▽ More
One of the main limitations of cesium atomic fountains has been the cold collision frequency shift. By using a method based on a transfer of population by adiabatic passage allowing to prepare cold atomic samples with a well defined ratio of atomic density as well as atom number the collisional shift is controlled at the 10E-3 of its value. A calibration of Zeeman sub-states contribution to the clock shift as a function of the field has been performed. Feshbach resonances have been observed for the first time at very low magnetic field and with a very good resolution. A Monte Carlo simulation has been performed and could fit properly some of experimental data. This constrains some parameters of the theory of collisions.
△ Less
Submitted 7 August, 2006; v1 submitted 13 July, 2004;
originally announced July 2004.
-
Improved Test of Lorentz Invariance in Electrodynamics
Authors:
Peter Wolf,
Michael E. Tobar,
Sebastien Bize,
Andre Clairon,
Andre N. Luiten,
Giorgio Santarelli
Abstract:
We report new results of a test of Lorentz invariance based on the comparison of a cryogenic sapphire microwave resonator and a hydrogen maser. The experimental results are shown together with an extensive analysis of systematic effects. Previously, this experiment has set the most stringent constraint on Kennedy-Thorndike type violations of Lorentz invariance. In this work we present new data a…
▽ More
We report new results of a test of Lorentz invariance based on the comparison of a cryogenic sapphire microwave resonator and a hydrogen maser. The experimental results are shown together with an extensive analysis of systematic effects. Previously, this experiment has set the most stringent constraint on Kennedy-Thorndike type violations of Lorentz invariance. In this work we present new data and interpret our results in the general Lorentz violating extension of the standard model of particle physics (SME). Within the photon sector of the SME, our experiment is sensitive to seven SME parameters. We marginally improve present limits on four of these, and by a factor 7 to 10 on the other three.
△ Less
Submitted 21 July, 2004; v1 submitted 20 July, 2004;
originally announced July 2004.
-
Ultrafast Resonant Polarization Interferometry: Towards the First Direct Detection of Vacuum Polarization
Authors:
Andre N. Luiten,
Jesse C. Petersen
Abstract:
Vacuum polarization, an effect predicted nearly 70 years ago, is still yet to be directly detected despite significant experimental effort. Previous attempts have made use of large liquid-helium cooled electromagnets which inadvertently generate spurious signals that mask the desired signal. We present a novel approach for the ultra-sensitive detection of optical birefringence that can be useful…
▽ More
Vacuum polarization, an effect predicted nearly 70 years ago, is still yet to be directly detected despite significant experimental effort. Previous attempts have made use of large liquid-helium cooled electromagnets which inadvertently generate spurious signals that mask the desired signal. We present a novel approach for the ultra-sensitive detection of optical birefringence that can be usefully applied to a laboratory detection of vacuum polarization. The new technique has a predicted birefringence measurement sensitivity of $Δn \sim 10^{20}$ in a 1 second measurement. When combined with the extreme polarizing fields achievable in this design we predict that a vacuum polarization signal will be seen in a measurement of just a few days in duration.
△ Less
Submitted 25 February, 2004; v1 submitted 16 February, 2004;
originally announced February 2004.
-
Detection of Vacuum Birefringence with Intense Laser Pulses
Authors:
Andre N. Luiten,
Jesse C. Petersen
Abstract:
We propose a novel technique that promises hope of being the first to directly detect a polarization in the quantum electrodynamic (QED) vacuum. The technique is based upon the use of ultra-short pulses of light circulating in low dispersion optical resonators. We show that the technique circumvents the need for large scale liquid helium cooled magnets, and more importantly avoids the experiment…
▽ More
We propose a novel technique that promises hope of being the first to directly detect a polarization in the quantum electrodynamic (QED) vacuum. The technique is based upon the use of ultra-short pulses of light circulating in low dispersion optical resonators. We show that the technique circumvents the need for large scale liquid helium cooled magnets, and more importantly avoids the experimental pitfalls that plague existing experiments that make use of these magnets. Likely improvements in the performance of optics and lasers would result in the ability to observe vacuum polarization in an experiment of only a few hours duration.
△ Less
Submitted 16 February, 2004;
originally announced February 2004.
-
Whispering Gallery Resonators and Tests of Lorentz Invariance
Authors:
Peter Wolf,
Michael E. Tobar,
Sebastien Bize,
Andre Clairon,
Andre N. Luiten,
Giorgio Santarelli
Abstract:
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We give a detailed description of microwave resonators operating in Whispering Gallery modes and then apply it to derive explicit models for Lorentz violating effects in our experiment. Models are calculated in the theoretical framework of Rob…
▽ More
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We give a detailed description of microwave resonators operating in Whispering Gallery modes and then apply it to derive explicit models for Lorentz violating effects in our experiment. Models are calculated in the theoretical framework of Robertson, Mansouri and Sexl and in the standard model extension (SME) of Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl test theory to $1/2 - β_{MS} + δ_{MS} = (1.2 \pm 2.2) \times 10^{-9}$ and $β_{MS} - α_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of the same order as the best results from other experiments for the former and represents a 70 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
△ Less
Submitted 10 February, 2004; v1 submitted 6 January, 2004;
originally announced January 2004.
-
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Authors:
S. Bize,
P. Wolf,
M. Abgrall,
L. Cacciapuoti,
A. Clairon,
J. Gruenert,
Ph. Laurent,
P. Lemonde,
I. Maksimovic,
C. Mandache,
H. Marion,
F. Pereira Dos Santos,
P. Rosenbusch,
G. Santarelli,
Y. Sortais,
C. Vian,
S. Zhang,
C. Salomon,
A. N. Luiten,
M. E. Tobar
Abstract:
We describe two experimental tests of the Equivalence Principle that are based on frequency measurements between precision oscillators and/or highly accurate atomic frequency standards. Based on comparisons between the hyperfine frequencies of 87Rb and 133Cs in atomic fountains, the first experiment constrains the stability of fundamental constants. The second experiment is based on a comparison…
▽ More
We describe two experimental tests of the Equivalence Principle that are based on frequency measurements between precision oscillators and/or highly accurate atomic frequency standards. Based on comparisons between the hyperfine frequencies of 87Rb and 133Cs in atomic fountains, the first experiment constrains the stability of fundamental constants. The second experiment is based on a comparison between a cryogenic sapphire oscillator and a hydrogen maser. It tests Local Lorentz Invariance. In both cases, we report recent results which improve significantly over previous experiments.
△ Less
Submitted 4 October, 2003;
originally announced October 2003.
-
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Authors:
P. Wolf,
S. Bize,
A. Clairon,
A. N. Luiten,
G. Santarelli,
M. E. Tobar
Abstract:
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters…
▽ More
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $δ- β+ 1/2 \leq 3.4 \times 10^{-9}$ and $β- α- 1 \leq 4.1 \times 10^{-7}$ which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.
△ Less
Submitted 11 June, 2003;
originally announced June 2003.
-
Tests of relativity using a microwave resonator
Authors:
Peter Wolf,
Sébastien Bize,
André Clairon,
André N. Luiten,
Giorgio Santarelli,
Michael E. Tobar
Abstract:
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters…
▽ More
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $δ- β+ 1/2 = (1.5\pm 4.2) \times 10^{-9}$ and $β- α- 1 = (-3.1\pm 6.9) \times 10^{-7}$ which is equivalent to the best previous result for the former and represents a 30 fold improvement for the latter.
△ Less
Submitted 16 October, 2002; v1 submitted 15 October, 2002;