Status and development of the TOP-IMPLART Project
Authors:
L. Picardi,
A. Ampollini,
P. Anello,
M. Balduzzi,
G. Bazzano,
F. Borgognoni,
E. Cisbani,
M. DAndrea,
C. De Angelis,
G. De Angelis,
S. Della Monaca,
G. Esposito,
F. Ghio,
F. Giuliani,
M. Lucentini,
C. Marino,
R. M. Montereali,
P. Nenzi,
C. Notaro,
C. Patrono,
C. Placido,
M. Piccinini,
C. Ronsivalle,
F. Santavenere,
A. Spurio
, et al. (5 additional authors not shown)
Abstract:
The TOP-IMPLART project consists of the design and implementation of a linear proton accelerator, its control and monitoring systems for the treatment of superficial and semi-deep tumors. The energy of 150 MeV (corresponding to a penetration in tissue of about 15 cm) is a milestone in design being useful for the proton therapy treatment of almost 50% of tumors based on their position and depth (in…
▽ More
The TOP-IMPLART project consists of the design and implementation of a linear proton accelerator, its control and monitoring systems for the treatment of superficial and semi-deep tumors. The energy of 150 MeV (corresponding to a penetration in tissue of about 15 cm) is a milestone in design being useful for the proton therapy treatment of almost 50% of tumors based on their position and depth (including ocular melanoma, head-neck tumors, pediatric tumors, and more superficial tumors). The capability to vary the intensity on a pulse-to-pulse basis combined with an electronic feedback system allows to get the required dose uniformity (2.5%) reducing the number of re-paintings. In this paper the state of the art and the objectives of the TOP-IMPLART project are described within the framework of the progress of Protontherapy.
△ Less
Submitted 12 October, 2020;
originally announced October 2020.
-
Limited Angle Tomography reconstruction for non-standard MBI system by means of parallel-hole and pinhole optics
Authors:
G. E. Poma,
F. Garibaldi,
F. Giuliani,
T. Insero,
M. Lucentini,
A. Marcucci,
P. Musico,
J. Nuyts,
F. Santavenere,
G. Schramm,
C. Sutera,
E. Cisbani
Abstract:
The purpose of the present work is the study of reconstruction properties of a new Molecular Breast Imaging (MBI) device for the early diagnosis of breast cancer, in Limited Angle Tomography (LAT), by using two asymmetric detector heads with different collimators. The detectors face each other in anti-parallel viewing direction and, mild-compressing the breast phantom, they are able to reconstruct…
▽ More
The purpose of the present work is the study of reconstruction properties of a new Molecular Breast Imaging (MBI) device for the early diagnosis of breast cancer, in Limited Angle Tomography (LAT), by using two asymmetric detector heads with different collimators. The detectors face each other in anti-parallel viewing direction and, mild-compressing the breast phantom, they are able to reconstruct the inner tumour of the phantoms with only a limited number of projections using a dedicated maximum-likelihood expectation maximization (ML-EM) algorithm. Phantoms, MBI system, as well as Monte Carlo simulator using Geant 4 Application for Tomographic Emission (GATE) software, are briefly described. MBI system's model has been implemented in IDL (Interactive Data Visualization), in order to evaluate the best LAT configuration of the system and its reconstruction ability by varying tumour's size, depth and uptake. LAT setup in real and simulated configurations, as well as the ML-EM method and the preliminary reconstruction results, are discussed.
△ Less
Submitted 8 April, 2020; v1 submitted 25 January, 2020;
originally announced January 2020.
-
Development of a high-resolution and high efficiency Single Photon detector for studying cardiovascular diseases in mice
Authors:
F. Garibaldi,
E. Cisbani,
F. Cusanno,
G. De Vincentis,
F. Giuliani,
M. Lucentini,
M. L. Magliozzi,
S. Majewski,
G. Marano,
P. Musico,
F. Santanvenere,
B. M. W. Tsui,
Y. Wang
Abstract:
SPECT systems using pinhole apertures permit radiolabeled molecular distributions to be imaged in vivo in small animals. Nevertheless studying cardiovascular diseases by means of small animal models is very challenging. Specifically, submillimeter spatial resolution, good energy resolution and high sensitivity are required. We designed what we consider the "optimal" radionuclide detector system fo…
▽ More
SPECT systems using pinhole apertures permit radiolabeled molecular distributions to be imaged in vivo in small animals. Nevertheless studying cardiovascular diseases by means of small animal models is very challenging. Specifically, submillimeter spatial resolution, good energy resolution and high sensitivity are required. We designed what we consider the "optimal" radionuclide detector system for this task. It should allow studying both detection of unstable atherosclerotic plaques and monitoring the effect of therapies. Using mice is particularly challenging in situations that require several intravenous injections of radiotracers, possibly for week or even months, in chronically ill animals. Thus, alternative routes of delivering the radiotracer in tail vein should be investigated. In this study we have performed preliminary measurements of detection of atherosclerotic plaques in genetically modified mice with high-resolution prototype detector. We have also evaluated the feasibility of assessing left ventricular perfusion by intraperitoneal delivering of MIBI-Tc in healthy mice.
△ Less
Submitted 19 October, 2019;
originally announced October 2019.
-
High-resolution hypernuclear spectroscopy at Jefferson Lab, Hall A
Authors:
Jefferson Lab Hall A Collaboration,
F. Garibaldi,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Beturin,
H. Benaoum,
J. Benesch,
P. Y. Bertin,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
F. Cusanno,
B. J. Craver,
G. De Cataldo
, et al. (75 additional authors not shown)
Abstract:
The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0p-shell region of nuclei such as the hypernuclei produced in electroproduction on 9Be, 12C and 16O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were adde…
▽ More
The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0p-shell region of nuclei such as the hypernuclei produced in electroproduction on 9Be, 12C and 16O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were added to the Hall A standard equipment. The high-quality beam, the good spectrometers and the new experimental devices allowed us to obtain very good results. For the first time, measurable strength with sub-MeV energy resolution was observed for the core-excited states of Lambda 12B. A high-quality Lambda 16N hypernuclear spectrum was likewise obtained. A first measurement of the Lambda binding energy for Lambda 16N, calibrated against the elementary reaction on hydrogen, was obtained with high precision, 13.76 +/- 0.16 MeV. Similarly, the first Lambda 9Li hypernuclear spectrum shows general agreement with theory (distorted-wave impulse approximation with the SLA and BS3 electroproduction models and shell-model wave functions). Some disagreement exists with respect to the relative strength of the states making up the first multiplet. A Lambda separation energy of 8.36 MeV was obtained, in agreement with previous results. It has been shown that the electroproduction of hypernuclei can provide information complementary to that obtained with hadronic probes and the gamma-ray spectroscopy technique.
△ Less
Submitted 26 July, 2018; v1 submitted 25 July, 2018;
originally announced July 2018.
-
A novel TOF-PET MRI detector for diagnosis and follow up of the prostate cancer
Authors:
F. Garibaldi,
S. Beging,
R. Canese,
G. Carpinelli,
N. Clinthorne,
S. Colilli,
L. Cosentino P. Finocchiaro,
F. Giuliani,
M. Gricia,
M. Lucentini,
S. Majewski,
E. Monno,
P. Musico,
F. Santavenere,
J. Tödter,
H. Wegener,
K. Ziemons
Abstract:
Prostate cancer is the most common disease in men and the second leading cause of death from cancer. Generic large imaging instruments used in cancer diagnosis have sensitivity, spatial resolution, and contrast inadequate for the task of imaging details of a small organ such as the prostate. In addition, multimodality imaging can play a significant role merging anatomical and functional details co…
▽ More
Prostate cancer is the most common disease in men and the second leading cause of death from cancer. Generic large imaging instruments used in cancer diagnosis have sensitivity, spatial resolution, and contrast inadequate for the task of imaging details of a small organ such as the prostate. In addition, multimodality imaging can play a significant role merging anatomical and functional details coming from simultaneous PET and MRI. Indeed, multi-parametric PET/MRI was demonstrated to improve diagnosis, but it suffers from too many false positives. In order to address the above limits of the current techniques, we have proposed, built and tested, thanks to the TOPEM project funded by Italian National Institute of Nuclear Phisics a prototype of an endorectal PET-TOF/MRI probe. In the applied magnification PET geometry, performance is dominated by a high-resolution detector placed closer to the source. The expected spatial resolution in the selected geometry is about 1.5 mm FWHM and efficiency a factor of 2 with respect to what obtained with the conventional PET scanner. In our experimental studies, we have obtained timing resolution of ~ 320 ps FWHM and at the same time Depth of Interaction (DOI) resolution of under 1 mm. Tests also showed that mutual adverse PET-MR effects are minimal. In addition, the matching endorectal RF coil was designed, built and tested. In the next planned studies, we expect that benefiting from the further progress in scintillator crystal surface treatment, in SiPM technology and associated electronics would allow us to significantly improve TOF resolution
△ Less
Submitted 24 August, 2017;
originally announced August 2017.
-
Spectroscopy of Lambda-9Li by electroproduction
Authors:
G. M. Urciuoli,
F. Cusanno,
S. Marrone,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Baturin,
P. Y. Bertin,
H. Benaoum,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
B. J. Craver,
G. De Cataldo,
C. W. de Jager
, et al. (73 additional authors not shown)
Abstract:
In the absence of accurate data on the free two-body hyperon-nucleon interaction, the spectra of hypernuclei can provide information on the details of the effective hyperon-nucleon interaction. Electroproduction of the hypernucleus Lambda-9Li has been studied for the first time with sub-MeV energy resolution in Hall A at Jefferson Lab on a 9Be target. In order to increase the counting rate and to…
▽ More
In the absence of accurate data on the free two-body hyperon-nucleon interaction, the spectra of hypernuclei can provide information on the details of the effective hyperon-nucleon interaction. Electroproduction of the hypernucleus Lambda-9Li has been studied for the first time with sub-MeV energy resolution in Hall A at Jefferson Lab on a 9Be target. In order to increase the counting rate and to provide unambiguous kaon identification, two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. The cross section to low-lying states of Lambda-9Li is concentrated within 3 MeV of the ground state and can be fitted with four peaks. The positions of the doublets agree with theory while a disagreement could exist with respect to the relative strengths of the peaks in the doublets. A Lambda separation energy of 8.36 +- 0.08 (stat.) +- 0.08 (syst.) MeV was measured, in agreement with an earlier experiment.
△ Less
Submitted 1 October, 2014; v1 submitted 22 May, 2014;
originally announced May 2014.
-
High Resolution Spectroscopy of 16N_Lambda by Electroproduction
Authors:
F. Cusanno,
G. M. Urciuoli,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Baturin,
P. Y. Bertin,
H. Benaoum,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
B. J. Craver,
G. De Cataldo,
C. W. de Jager,
R. De Leo
, et al. (74 additional authors not shown)
Abstract:
An experimental study of the 16O(e,e'K^+)16N_Lambda reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e,e'K^+)Lambda,Sigma_0 exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76 +/- 0.16 MeV was obtained for 16N_Lambda with better precision than p…
▽ More
An experimental study of the 16O(e,e'K^+)16N_Lambda reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e,e'K^+)Lambda,Sigma_0 exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76 +/- 0.16 MeV was obtained for 16N_Lambda with better precision than previous measurements on the mirror hypernucleus 16O_Lambda. Precise energies have been determined for peaks arising from a Lambda in s and p orbits coupled to the p_{1/2} and p_{3/2} hole states of the 15N core nucleus.
△ Less
Submitted 12 November, 2009; v1 submitted 21 October, 2008;
originally announced October 2008.
-
High Resolution Spectroscopy of 12B_Lambda by Electroproduction
Authors:
M. Iodice,
F. Cusanno,
A. Acha,
P. Ambrozewicz,
K. A. Aniol,
P. Baturin,
P. Y. Bertin,
H. Benaoum,
K. I. Blomqvist,
W. U. Boeglin,
H. Breuer,
P. Brindza,
P. Bydzovsky,
A. Camsonne,
C. C. Chang,
J. -P. Chen,
Seonho Choi,
E. A. Chudakov,
E. Cisbani,
S. Colilli,
L. Coman,
B. J. Craver,
G. DeCataldo,
C. W. deJager,
R. DeLeo
, et al. (74 additional authors not shown)
Abstract:
An experiment measuring electroproduction of hypernuclei has been performed in Hall A at Jefferson Lab on a $^{12}$C target. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. An unprecedented energy resolution of less than 700 keV FWHM has bee…
▽ More
An experiment measuring electroproduction of hypernuclei has been performed in Hall A at Jefferson Lab on a $^{12}$C target. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. An unprecedented energy resolution of less than 700 keV FWHM has been achieved. Thus, the observed \lam{12}{B} spectrum shows for the first time identifiable strength in the core-excited region between the ground-state {\it s}-wave $Λ$ peak and the 11 MeV {\it p}-wave $Λ$ peak.
△ Less
Submitted 23 May, 2007;
originally announced May 2007.