-
TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector
Authors:
E. Albuquerque,
M. Araújo,
A. Benaglia,
A. Boletti,
R. Bugalho,
T. Coutinho,
F. De Guio,
P. Faccioli,
L. Ferramacho,
M. Firlej,
T. Fiutowski,
R. Francisco,
M. Gallinaro,
A. Ghezzi,
J. Hollar,
M. Idzik,
H. Legoinha,
N. Leonardo,
C. Leong,
M. T. Lucchini,
M. Malberti,
G. Marozzo,
G. Da Molin,
J. Moron,
T. Niknejad
, et al. (16 additional authors not shown)
Abstract:
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.…
▽ More
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.
△ Less
Submitted 1 April, 2024;
originally announced April 2024.
-
Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence
Authors:
A. Bornheim,
W. Lustermann,
K. Stachon,
G. Reales Gutiérrez,
A. Benaglia,
F. De Guio,
A. Ghezzi,
M. T. Lucchini,
M. Malberti,
S. Palluotto,
T. Tabarelli de Fatis,
M. Benettoni,
R. Carlin,
M. Tosi,
R. Rossin,
P. Meridiani,
R. Paramatti,
F. Santanastasio,
J. C. Silva,
J. Varela,
A. Heering,
A. Karneyeu,
Y. Musienko,
M. Wayne,
T. Anderson
, et al. (5 additional authors not shown)
Abstract:
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about…
▽ More
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.
△ Less
Submitted 23 August, 2023; v1 submitted 1 June, 2023;
originally announced June 2023.
-
Sub-10 ps time tagging of electromagnetic showers with scintillating glasses and SiPMs
Authors:
Marco T. Lucchini,
Andrea Benaglia,
Stefan Gundacker,
Jack Illare,
Paul Lecoq,
Alfred A. Margaryan,
Ashot A. Margaryan,
Kristof Pauwels,
Etiennette Auffray
Abstract:
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels expected at such colliders compared to hadron colliders, enable the use of less radiation tolerant but cheaper technologies for the construction of the particle detec…
▽ More
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels expected at such colliders compared to hadron colliders, enable the use of less radiation tolerant but cheaper technologies for the construction of the particle detectors. This opportunity has triggered a renewed interest in the development of scintillating glasses for the instrumentation of large detector volumes such as homogeneous calorimeters. While the performance of such scintillators remains typically inferior in terms of light yield and radiation tolerance compared to that of many scintillating crystals, substantial progress has been made over the recent years. In this paper we discuss the time resolution of cerium-doped Alkali Free Fluorophosphate scintillating glasses, read-out with silicon photo-multipliers in detecting single charged tracks and at different positions along the longitudinal development of an electromagnetic shower, using respectively 150~GeV pions and 100~GeV electron beams at the CERN SPS H2 beam line. A single sensor time resolution of 14.4~ps and 5-7~ps was measured respectively in the two cases. With such a performance the present technology has the potential to address an emerging requirement of future detectors at collider experiments: measuring the time-of-flight of single charged particles as well as that of neutral particles showering inside the calorimeter and the time development of showers.
△ Less
Submitted 15 March, 2023; v1 submitted 6 December, 2022;
originally announced December 2022.
-
Comparative characterization study of LYSO:Ce crystals for timing applications
Authors:
F. M. Addesa,
P. Barria,
R. Bianco,
M. Campana,
F. Cavallari,
A. Cemmi,
M. Cipriani,
I. Dafinei,
B. ď Orsi,
D. del Re,
M. Diemoz,
G. ď Imperio,
E. Di Marco,
I. Di Sarcina,
M. Enculescu,
E. Longo,
M. T. Lucchini,
F. Marchegiani,
P. Meridiani,
S. Nisi,
G. Organtini,
F. Pandolfi,
R. Paramatti,
V. Pettinacci,
C. Quaranta
, et al. (6 additional authors not shown)
Abstract:
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce (…
▽ More
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce ($[Lu_{(1-x)}Y_x]_2SiO_5$:$Ce$) crystals is presented. It involves for the first time a large number of crystal samples (180) of the same size from a dozen of producers.The study consists of a comparative characterization of LYSO:Ce crystal products available on the market by mechanical, optical and scintillation measurements and aims specifically, to investigate key parameters of timing applications for HEP.
△ Less
Submitted 3 June, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Precision timing for collider-experiment-based calorimetry
Authors:
S. V. Chekanov,
F. Simon,
V. Boudry,
W. Chung,
P. W. Gorham,
M. Nguyen,
C. G. Tully,
S. C. Eno,
Y. Lai,
A. V. Kotwal,
S. Ko,
I. Laktineh,
S. Lee,
J. S. H. Lee,
M. T. Lucchini,
R. Prechelt,
H. Yoo,
C. -H Yeh,
S. -S. Yu,
G. S. Varner,
R. Zhu
Abstract:
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the f…
▽ More
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the full detector volume, and dedicated timing layers integrated in calorimeter systems. A selection of technologies for the different approaches is also discussed.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Particle Flow with a Hybrid Segmented Crystal and Fiber Dual-Readout Calorimeter
Authors:
Marco T. Lucchini,
Lorenzo Pezzotti,
Giacomo Polesello,
Christopher G. Tully
Abstract:
In the reconstruction of physics events at future e$^+$e$^-$ colliders the calorimeter design has a crucial role in the overall detector performance. The reconstruction of events with many jets in their final state sets stringent requirements on the jet energy and angular resolutions. The energy resolution for jets with energy of about 45 GeV is required to be at the 4-5\% level to enable an effic…
▽ More
In the reconstruction of physics events at future e$^+$e$^-$ colliders the calorimeter design has a crucial role in the overall detector performance. The reconstruction of events with many jets in their final state sets stringent requirements on the jet energy and angular resolutions. The energy resolution for jets with energy of about 45 GeV is required to be at the 4-5\% level to enable an efficient separation of the W and Z boson invariant masses. We demonstrate in this paper how such a performance can be achieved by exploiting a particle flow algorithm tailored for a hybrid dual-readout calorimeter made of segmented crystals and fibers. The excellent energy resolution and linearity of such calorimeter for both photons and neutral hadrons ($3\%/\sqrt{E}$ and $26\%/\sqrt{E}$, respectively), inherent to the homogeneous crystals and dual-readout technological choices, provides a powerful handle for the development of a new approach for particle identification and jet reconstruction. While the dual-readout particle flow algorithm (DR-PFA) presented in this paper is at its early stage of development, it already demonstrates the potential of a hybrid dual-readout calorimeter for jet reconstruction by improving the jet energy resolution with respect to a calorimeter-only reconstruction from 6.0\% to about 4.5\% for 45 GeV jets.
△ Less
Submitted 29 April, 2022; v1 submitted 3 February, 2022;
originally announced February 2022.
-
New perspectives on segmented crystal calorimeters for future colliders
Authors:
Marco T. Lucchini,
Wonyong Chung,
Sarah C. Eno,
Yihui Lai,
Lorenzo Lucchini,
Minh-Thi Nguyen,
Christopher G. Tully
Abstract:
Crystal calorimeters have a long history of pushing the frontier on high-resolution electromagnetic (EM) calorimetry. We explore in this paper major innovations in collider detector performance that can be achieved with crystal calorimetry when longitudinal segmentation and dual-readout capabilities are combined with a new high EM resolution approach to PFA in multi-jet events, such as…
▽ More
Crystal calorimeters have a long history of pushing the frontier on high-resolution electromagnetic (EM) calorimetry. We explore in this paper major innovations in collider detector performance that can be achieved with crystal calorimetry when longitudinal segmentation and dual-readout capabilities are combined with a new high EM resolution approach to PFA in multi-jet events, such as $e^+e^+\rightarrow HZ$ events in all-hadronic final-states at Higgs factories. We demonstrate a new technique for pre-processing $π^0$ momenta through combinatoric di-photon pairing in advance of applying jet algorithms. This procedure significantly reduces $π^0$ photon splitting across jets in multi-jet events. The correct photon-to-jet assignment efficiency improves by a factor of 3 with a $3\%/\sqrt{E}$ EM resolution. In addition, the technique of bremsstrahlung photon recovery significantly improves electron momentum measurements. A high EM resolution calorimeter increases the Z boson recoil mass resolution in Higgstrahlung events for decays into electron pairs to 80% of that for muon pairs. We present the design and optimization of a highly segmented crystal detector concept that achieves the required energy resolution, and a time resolution better than 30 ps providing exceptional particle identification capabilities. We demonstrate that, contrary to previous detector designs that suffered from large neutral hadron resolution degradation from one interaction length of crystals in front of a sampling hadron calorimeter, the implementation of dual-readout on crystals permits to achieve a resolution better than $30\%/\sqrt{E}\oplus 2\%$ for neutral hadrons. Our studies find that the integration of crystal calorimetry into future Higgs factory collider detectors can open new perspectives by yielding the highest level of combined EM and neutral hadron resolution in the PFA paradigm.
△ Less
Submitted 15 September, 2020; v1 submitted 1 August, 2020;
originally announced August 2020.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.