-
A plastics hierarchy of fates: sustainable choices for a circular future
Authors:
Kristoffer Kortsen,
Siobhan Kilbride,
Stephen R. Lowe,
Adam Peirce,
Michael P. Shaver
Abstract:
Plastics are ubiquitous in modern society, but the linear model of produce, use, and dispose results in massive amounts of resource consumption and pollution. Landfill and incineration of plastic waste is endemic, with no consensus on a clear path towards a more sustainable model. Progress is often hampered by a lack of clarity on what choices will enable a more sustainable circular plastics econo…
▽ More
Plastics are ubiquitous in modern society, but the linear model of produce, use, and dispose results in massive amounts of resource consumption and pollution. Landfill and incineration of plastic waste is endemic, with no consensus on a clear path towards a more sustainable model. Progress is often hampered by a lack of clarity on what choices will enable a more sustainable circular plastics economy. Our Plastics Hierarchy of Fates tool addresses this by bringing together scattered information on the end-of-life fates of plastics in a more accessible format. This tool will support manufacturing, processing, and policy decisions in the push for a more sustainable future. Potential sorting and recycling decisions for plastics waste are discussed in the hierarchy and the consequences of different decisions are highlighted. The hierarchy is meant to inform potential outcomes but can also be used to help shape future interventions.
△ Less
Submitted 26 March, 2023;
originally announced March 2023.
-
Representing the "butterfly" projection in FITS - projection code XPH
Authors:
Mark R. Calabretta,
Stuart R. Lowe
Abstract:
The "butterfly" projection is constructed as the polar layout of the HEALPix projection with (H,K) = (4,3). This short article formalises its representation in FITS.
The "butterfly" projection is constructed as the polar layout of the HEALPix projection with (H,K) = (4,3). This short article formalises its representation in FITS.
△ Less
Submitted 30 August, 2013;
originally announced August 2013.
-
One Centimetre Receiver Array-prototype observations of the CRATES sources at 30 GHz
Authors:
M. W. Peel,
M. P. Gawronski,
R. A. Battye,
M. Birkinshaw,
I. W. A. Browne,
R. J. Davis,
R. Feiler,
A. J. Kus,
K. Lancaster,
S. R. Lowe,
B. M. Pazderska,
E. Pazderski,
B. F. Roukema,
P. N. Wilkinson
Abstract:
Knowledge of the population of radio sources in the range ~2-200 GHz is important for understanding their effects on measurements of the Cosmic Microwave Background power spectrum. We report measurements of the 30 GHz flux densities of 605 radio sources from the Combined Radio All-sky Targeted Eight-GHz Survey (CRATES), which have been made with the One Centimetre Receiver Array prototype (OCRA-p)…
▽ More
Knowledge of the population of radio sources in the range ~2-200 GHz is important for understanding their effects on measurements of the Cosmic Microwave Background power spectrum. We report measurements of the 30 GHz flux densities of 605 radio sources from the Combined Radio All-sky Targeted Eight-GHz Survey (CRATES), which have been made with the One Centimetre Receiver Array prototype (OCRA-p) on the Torun 32-m telescope. The flux densities of sources that were also observed by WMAP and previous OCRA surveys are in broad agreement with those reported here, however a number of sources display intrinsic variability. We find a good correlation between the 30 GHz and Fermi gamma-ray flux densities for common sources. We examine the radio spectra of all observed sources and report a number of Gigahertz-peaked and inverted spectrum sources. These measurements will be useful for comparison to those from the Low Frequency Instrument of the Planck satellite, which will make some of its most sensitive observations in the region covered here.
△ Less
Submitted 17 May, 2011; v1 submitted 29 July, 2010;
originally announced July 2010.
-
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Authors:
F. Villa,
L. Terenzi,
M. Sandri,
P. Meinhold,
T. Poutanen,
P. Battaglia,
C. Franceschet,
N. Hughes,
M. Laaninen,
P. Lapolla,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
M. Frailis,
E. Franceschi,
S. Galeotta,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
L. Mendes,
A. Mennella,
G. Morgante
, et al. (49 additional authors not shown)
Abstract:
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryoge…
▽ More
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
A systematic approach to the Planck LFI end-to-end test and its application to the DPC Level 1 pipeline
Authors:
M. Frailis,
M. Maris,
A. Zacchei,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
S. R. Lowe,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
F. Pasian,
F. Perrotta,
M. Sandri,
L. Terenzi,
M. Tomasi
, et al. (1 additional authors not shown)
Abstract:
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekee** telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and…
▽ More
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekee** telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and development of the Level 1 software has followed the ESA Software Engineering Standards. A fundamental step in the software life cycle is the Verification and Validation of the software. The purpose of this work is to show an example of procedures, test development and analysis successfully applied to a key software project of an ESA mission. We present the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by detailing the methods used and the results obtained. Different approaches have been used to test the scientific and housekee** data processing. Scientific data processing has been tested by injecting signals with known properties directly into the acquisition electronics, in order to generate a test dataset of real telemetry data and reproduce as much as possible nominal conditions. For the HK telemetry processing, validation software have been developed to inject known parameter values into a set of real housekee** packets and perform a comparison with the corresponding timelines generated by the Level 1. With the proposed validation and verification procedure, where the on-board and ground processing are viewed as a single pipeline, we demonstrated that the scientific and housekee** processing of the Planck-LFI raw data is correct and meets the project requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
Authors:
R. J. Davis,
A. Wilkinson,
R. D. Davies,
W. F. Winder,
N. Roddis,
E. J. Blackhurst,
D. Lawson,
S. R. Lowe,
C. Baines,
M. Butlin,
A. Galtress,
D. Shepherd,
B. Aja,
E. Artal,
M. Bersanelli,
R. C. Butler,
C. Castelli,
F. Cuttaia,
O. D'Arcangelo,
T. Gaier,
R. Hoyland,
D. Kettle,
R. Leonardi,
N. Mandolesi,
A. Mennella
, et al. (6 additional authors not shown)
Abstract:
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo…
▽ More
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band.
The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Level 1 on-ground telemetry handling in Planck LFI
Authors:
A. Zacchei,
M. Frailis,
M. Maris,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
D. Maino,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
P. Meinhold,
L. Mendes
, et al. (9 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeepin…
▽ More
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekee** data by sampling regularly the on-board sensors and registers. The housekee** data provides information on the overall health status of the instrument and on the scientific data quality. The scientific and housekee** data are collected on-board into telemetry packets compliant with the ESA Packet Telemetry standards. They represent the primary input to the first processing level of the LFI Data Processing Centre. In this work we show the software systems which build the LFI Level 1. A real-time assessment system, based on the ESA SCOS 2000 generic mission control system, has the main purpose of monitoring the housekee** parameters of LFI and detect possible anomalies. A telemetry handler system processes the housekee** and scientific telemetry of LFI, generating timelines for each acquisition chain and each housekee** parameter. Such timelines represent the main input to the subsequent processing levels of the LFI DPC. A telemetry quick-look system allows the real-time visualization of the LFI scientific and housekee** data, by also calculating quick statistical functions and fast Fourier transforms. The LFI Level 1 has been designed to support all the mission phases, from the instrument ground tests and calibration to the flight operations, and developed according to the ESA engineering standards.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Off-line radiometric analysis of Planck/LFI data
Authors:
M. Tomasi,
A. Mennella,
S. Galeotta,
S. R. Lowe,
L. Mendes,
R. Leonardi,
F. Villa,
B. Cappellini,
A. Gregorio,
P. Meinhold,
M. Sandri,
F. Cuttaia,
L. Terenzi,
M. Maris,
L. Valenziano,
M. J. Salmon,
M. Bersanelli,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
E. Franceschi,
F. Gasparo,
G. Maggio
, et al. (13 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common pla…
▽ More
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Noise Properties of the Planck-LFI Receivers
Authors:
P. Meinhold,
R. Leonardi,
B. Aja,
E. Artal,
P. Battaglia,
M. Bersanelli,
E. Blackhurst,
C. R. Butler,
L. P. Cuevas,
F. Cuttaia,
O. D'Arcangelo,
R. Davis,
M. L. de la Fuente,
M. Frailis,
C. Franceschet,
E. Franceschi,
T. Gaier,
S. Galeotta,
A. Gregorio,
R. Hoyland,
N. Hughes,
P. Jukkala,
D. Kettle,
M. Laaninen,
P. Leutenegger
, et al. (25 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: the Planck-LFI programme
Authors:
N. Mandolesi,
M. Bersanelli,
R. C. Butler,
E. Artal,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
M. Bartelmann,
K. Bennett,
P. Bhandari,
A. Bonaldi,
J. Borrill,
M. Bremer,
C. Burigana,
R. C. Bowman,
P. Cabella,
C. Cantalupo,
B. Cappellini,
T. Courvoisier,
G. Crone,
F. Cuttaia,
L. Danese,
O. D'Arcangelo,
R. D. Davies
, et al. (118 additional authors not shown)
Abstract:
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic…
▽ More
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
△ Less
Submitted 15 January, 2010;
originally announced January 2010.
-
30 GHz observations of sources in the VSA fields
Authors:
M. P. Gawronski,
M. W. Peel,
K. Lancaster,
R. A. Battye,
M. Birkinshaw,
I. W. A. Browne,
M. L. Davies,
R. J. Davis,
R. Feiler,
T. M. O. Franzen,
R. Genova-Santos,
A. J. Kus,
S. R. Lowe,
B. M. Pazderska,
E. Pazderski,
G. G. Pooley,
B. F. Roukema,
E. M. Waldram,
P. N. Wilkinson
Abstract:
Small angular scale (high l) studies of cosmic microwave background anisotropies require accurate knowledge of the statistical properties of extragalactic sources at cm-mm wavelengths. We have used a 30 GHz dual-beam receiver (OCRA-p) on the Torun 32-m telescope to measure the flux densities of 121 sources in VSA fields selected at 15 GHz with the Ryle Telescope. We have detected 57 sources abov…
▽ More
Small angular scale (high l) studies of cosmic microwave background anisotropies require accurate knowledge of the statistical properties of extragalactic sources at cm-mm wavelengths. We have used a 30 GHz dual-beam receiver (OCRA-p) on the Torun 32-m telescope to measure the flux densities of 121 sources in VSA fields selected at 15 GHz with the Ryle Telescope. We have detected 57 sources above a limiting flux density of 5mJy, of which 31 sources have a flux density greater than 10mJy, which is our effective completeness limit. From these measurements we derive a surface density of sources above 10mJy at 30 GHz of 2.0+/-0.4 per square degree. This is consistent with the surface density obtained by Mason et al. (2009) who observed a large sample of sources selected at a much lower frequency (1.4 GHz). We have also investigated the dependence of the spectral index distribution on flux density by comparing our results with those for sources above 1 Jy selected from the WMAP 22 GHz catalogue. We conclude that the proportion of steep spectrum sources increases with decreasing flux density, qualitatively consistent with the predictions of deZotti et al. (2005). We find no evidence for an unexpected population of sources whose spectra rise towards high frequencies, which would affect our ability to interpret current high resolution CMB observations at 30 GHz and above.
△ Less
Submitted 7 September, 2009;
originally announced September 2009.
-
Modelling the Galactic Magnetic Field on the Plane in 2D
Authors:
T. R. Jaffe,
J. P. Leahy,
A. J. Banday,
S. M. Leach,
S. R. Lowe,
A. Wilkinson
Abstract:
We present a method for parametric modelling of the physical components of the Galaxy's magnetised interstellar medium, simulating the observables, and map** out the likelihood space using a Markov Chain Monte-Carlo analysis. We then demonstrate it using total and polarised synchrotron emission data as well as rotation measures of extragalactic sources. With these three datasets, we define and…
▽ More
We present a method for parametric modelling of the physical components of the Galaxy's magnetised interstellar medium, simulating the observables, and map** out the likelihood space using a Markov Chain Monte-Carlo analysis. We then demonstrate it using total and polarised synchrotron emission data as well as rotation measures of extragalactic sources. With these three datasets, we define and study three components of the magnetic field: the large-scale coherent field, the small-scale isotropic random field, and the ordered field. In this first paper, we use only data along the Galactic plane and test a simple 2D logarithmic spiral model for the magnetic field that includes a compression and a shearing of the random component giving rise to an ordered component. We demonstrate with simulations that the method can indeed constrain multiple parameters yielding measures of, for example, the ratios of the magnetic field components. Though subject to uncertainties in thermal and cosmic ray electron densities and depending on our particular model parametrisation, our preliminary analysis shows that the coherent component is a small fraction of the total magnetic field and that an ordered component comparable in strength to the isotropic random component is required to explain the polarisation fraction of synchrotron emission. We outline further work to extend this type of analysis to study the magnetic spiral arm structure, the details of the turbulence as well as the 3D structure of the magnetic field.
△ Less
Submitted 29 January, 2010; v1 submitted 23 July, 2009;
originally announced July 2009.
-
AstroTwitter
Authors:
S. R. Lowe
Abstract:
AstroTwitter aims to make it easy for both professional and amateur telescopes to let the world know what they are observing in real-time.
AstroTwitter aims to make it easy for both professional and amateur telescopes to let the world know what they are observing in real-time.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Survey of Planetary Nebulae at 30 GHz with OCRA-p
Authors:
B. M. Pazderska,
M. P. Gawronski,
R. Feiler,
M. Birkinshaw,
I. W. A. Browne,
R. Davis,
A. J. Kus,
K. Lancaster,
S. R. Lowe,
E. Pazderski,
M. Peel,
P. N. Wilkinson
Abstract:
We report the results of a survey of 442 planetary nebulae at 30 GHz. The purpose of the survey is to develop a list of planetary nebulae as calibration sources which could be used for high frequency calibration in future. For 41 PNe with sufficient data, we test the emission mechanisms in order to evaluate whether or not spinning dust plays an important role in their spectra at 30 GHz.
The 30…
▽ More
We report the results of a survey of 442 planetary nebulae at 30 GHz. The purpose of the survey is to develop a list of planetary nebulae as calibration sources which could be used for high frequency calibration in future. For 41 PNe with sufficient data, we test the emission mechanisms in order to evaluate whether or not spinning dust plays an important role in their spectra at 30 GHz.
The 30-GHz data were obtained with a twin-beam differencing radiometer, OCRA-p, which is in operation on the Torun 32-m telescope. Sources were scanned both in right ascension and declination. We estimated flux densities at 30 GHz using a free-free emission model and compared it with our data.
The primary result is a catalogue containing the flux densities of 93 planetary nebulae at 30 GHz. Sources with sufficient data were compared with a spectral model of free-free emission. The model shows that free-free emission can generally explain the observed flux densities at 30 GHz thus no other emission mechanism is needed to account for the high frequency spectra.
△ Less
Submitted 23 February, 2009;
originally announced February 2009.
-
30 GHz flux density measurements of the Caltech-Jodrell flat-spectrum sources with OCRA-p
Authors:
S. R. Lowe,
M. P. GawroĊski,
P. N. Wilkinson,
A. J. Kus,
I. W. A. Browne,
E. Pazderski,
R. Feiler,
D. Kettle
Abstract:
To measure the 30-GHz flux densities of the 293 sources in the Caltech-Jodrell Bank flat-spectrum (CJF) sample. The measurements are part of an ongoing programme to measure the spectral energy distributions of flat spectrum radio sources and to correlate them with the milliarcsecond structures from VLBI and other measured astrophysical properties. The 30-GHz data were obtained with a twin-beam d…
▽ More
To measure the 30-GHz flux densities of the 293 sources in the Caltech-Jodrell Bank flat-spectrum (CJF) sample. The measurements are part of an ongoing programme to measure the spectral energy distributions of flat spectrum radio sources and to correlate them with the milliarcsecond structures from VLBI and other measured astrophysical properties. The 30-GHz data were obtained with a twin-beam differencing radiometer system mounted on the Torun 32-m telescope. The system has an angular resolution of 1.2 arcmin. Together with radio spectral data obtained from the literature, the 30-GHz data have enabled us to identify 42 of the CJF sources as Giga-hertz Peaked Spectrum (GPS) sources. Seventeen percent of the sources have rising spectra (alpha > 0) between 5 and 30 GHz.
△ Less
Submitted 23 July, 2007;
originally announced July 2007.