-
Limits to Ionization-Parameter Map** as a Diagnostic of HII Region Optical Depth
Authors:
Amit N. Sawant,
Eric W. Pellegrini,
M. S. Oey,
Jesús López-Hernández,
Genoveva Micheva
Abstract:
We employ ionization-parameter map** (IPM) to infer the optical depth of HII regions in the northern half of M33. We construct [OIII]$λ5007$/[OII]$λ3727$ and [OIII]$λ5007$/[SII]$λ6724$ ratio maps from narrow-band images continuum-subtracted in this way, from which we classify the HII regions by optical depth to ionizing radiation, based on their ionization structure. This method works relatively…
▽ More
We employ ionization-parameter map** (IPM) to infer the optical depth of HII regions in the northern half of M33. We construct [OIII]$λ5007$/[OII]$λ3727$ and [OIII]$λ5007$/[SII]$λ6724$ ratio maps from narrow-band images continuum-subtracted in this way, from which we classify the HII regions by optical depth to ionizing radiation, based on their ionization structure. This method works relatively well in the low metallicity regime, $12 + \log(\rm O/H) \leq 8.4$, where [OIII]$λ\lambda4949,5007$ is strong. However, at higher metallicities, the method breaks down due to the strong dependence of the [OIII]$λ\lambda4959,5007$ emission lines on the nebular temperature. Thus, although O$^{++}$ may be present in metal-rich HII regions, these commonly used emission lines do not serve as a useful indicator of its presence, and hence, the O ionization state. In addition, IPM as a diagnostic of optical depth is limited by spatial resolution. We also report a region of highly excited [OIII] extending over an area $\sim$ 1 kpc across and [OIII]$\lambda5007$ luminosity of $4.9\pm 1.5\times10^{38}$ erg/s, which is several times higher than the ionizing budget of any potential sources in this portion of the galaxy. Finally, this work introduces a new method for continuum subtraction of narrow-band images based on the dispersion of pixels around the mode of the diffuse-light flux distribution. In addition to M33, we demonstrate the method on C III]$λ$1909 imaging of Haro~11, ESO 338-IG004, and Mrk~71.
△ Less
Submitted 8 September, 2021;
originally announced September 2021.
-
Some aspects of Rotation Theory on compact abelian groups
Authors:
Manuel Cruz-López,
Francisco J. López-Hernández,
Alberto Verjovsky
Abstract:
In this paper we present a generalization of Poincaré's Rotation Theory of homeomorphisms of the circle to the case of one-dimensional compact abelian groups which are solenoidal groups, {\it i.e.}, groups which fiber over the circle with fiber a Cantor abelian group. We define rotation elements, \emph{à la} Poincaré and discuss the dynamical properties of translations on these solenoidal groups.…
▽ More
In this paper we present a generalization of Poincaré's Rotation Theory of homeomorphisms of the circle to the case of one-dimensional compact abelian groups which are solenoidal groups, {\it i.e.}, groups which fiber over the circle with fiber a Cantor abelian group. We define rotation elements, \emph{à la} Poincaré and discuss the dynamical properties of translations on these solenoidal groups. We also study the semiconjugation problem when the rotation element generates a dense subgroup of the solenoidal group. Finally, we comment on the relation between Rotation Theory and entropy for these homeomorphisms, since unlike the case of the circle, for the solenoids considered here there are homeomorphisms (not homotopic to the identity) with positive entropy.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Characterization of a novel automated microfiltration device for the efficient isolation and analysis of circulating tumor cells from clinical blood samples
Authors:
Juan F. Yee-de León,
Brenda Soto-García,
Diana Aráiz-Hernández,
Jesús Rolando Delgado-Balderas,
Miguel A. Esparza,
Carlos Aguilar-Avelar,
J. D. Wong-Campos,
Franco Chacón,
José Y. López-Hernández,
A. Mauricio González-Treviño,
José R. Yee-de León,
Jorge L. Zamora-Mendoza,
Mario M. Alvarez,
Grissel Trujillo-de Santiago,
Lauro S. Gómez-Guerra,
Celia N. Sánchez-Domínguez,
Liza P. Velarde-Calvillo,
Alejandro Abarca-Blanco
Abstract:
The detection and analysis of circulating tumor cells (CTCs) may enable a broad range of cancer-related applications, including the identification of acquired drug resistance during treatments. However, the non-scalable fabrication, prolonged sample processing times, and the lack of automation, associated with most of the technologies developed to isolate these rare cells, have impeded their trans…
▽ More
The detection and analysis of circulating tumor cells (CTCs) may enable a broad range of cancer-related applications, including the identification of acquired drug resistance during treatments. However, the non-scalable fabrication, prolonged sample processing times, and the lack of automation, associated with most of the technologies developed to isolate these rare cells, have impeded their transition into the clinical practice. This work describes a novel membrane-based microfiltration device comprised of a fully automated sample processing unit and a machine-vision-enabled imaging system that allows the efficient isolation and rapid analysis of CTCs from blood. The device performance was characterized using four prostate cancer cell lines, including PC-3, VCaP, DU-145, and LNCaP, obtaining high assay reproducibility and capture efficiencies greater than 93% after processing 7.5 mL blood samples from healthy donors, spiked with 100 cancer cells. Cancer cells remained viable after filtration due to the minimal shear stress exerted over cells during the procedure, while the identification of cancer cells by immunostaining was not affected by the number of non-specific events captured on the membrane. We were also able to identify the androgen receptor (AR) point mutation T878A from 7.5 mL blood samples spiked with 50 LNCaP cells using RT-PCR and Sanger sequencing. Finally, CTCs were detected in 8 of 8 samples from patients diagnosed with metastatic prostate cancer (mean $\pm$ SEM = 21 $\pm$ 2.957 CTCs/mL, median = 21 CTC/mL), thereby validating the potential clinical utility of the device.
△ Less
Submitted 11 December, 2019;
originally announced December 2019.
-
Bohr-Fourier series on solenoids via its transversal variation
Authors:
Manuel Cruz-López,
Francisco J. López-Hernández
Abstract:
The Bohr-Fourier series development on one dimensional solenoids is analyzed by using invariant functions and extending Bohr's theory through the study of transversal variation
The Bohr-Fourier series development on one dimensional solenoids is analyzed by using invariant functions and extending Bohr's theory through the study of transversal variation
△ Less
Submitted 1 March, 2019;
originally announced March 2019.
-
Dust emission at 8-mic and 24-mic as Diagnostics of HII Region Radiative Transfer
Authors:
M. S. Oey,
J. Lopez-Hernandez,
J. A. Kellar,
E. W. Pellegrini,
K. D. Gordon,
K. E. Jameson,
A. Li,
S. C. Madden,
M. Meixner,
J. Roman-Duval,
C. Bot,
M. Rubio,
A. G. G. M. Tielens
Abstract:
We use the Spitzer SAGE survey of the Magellanic Clouds to evaluate the relationship between the 8-mic PAH emission, 24-mic hot dust emission, and HII region radiative transfer. We confirm that in the higher-metallicity Large Magellanic Cloud, PAH destruction is sensitive to optically thin conditions in the nebular Lyman continuum: objects identified as optically thin candidates based on nebular i…
▽ More
We use the Spitzer SAGE survey of the Magellanic Clouds to evaluate the relationship between the 8-mic PAH emission, 24-mic hot dust emission, and HII region radiative transfer. We confirm that in the higher-metallicity Large Magellanic Cloud, PAH destruction is sensitive to optically thin conditions in the nebular Lyman continuum: objects identified as optically thin candidates based on nebular ionization structure show 6 times lower median 8-mic surface brightness (0.18 mJy arcsec^-2) than their optically thick counterparts (1.2 mJy arcsec^-2). The 24-mic surface brightness also shows a factor of 3 offset between the two classes of objects (0.13 vs 0.44 mJy arcsec^-2, respectively), which is driven by the association between the very small dust grains and higher density gas found at higher nebular optical depths. In contrast, PAH and dust formation in the low-metallicity Small Magellanic Cloud is strongly inhibited such that we find no variation in either 8-mic or 24-mic emission between our optically thick and thin samples. This is attributable to extremely low PAH and dust production together with high, corrosive UV photon fluxes in this low-metallicity environment. The dust mass surface densities and gas-to-dust ratios determined from dust maps using Herschel HERITAGE survey data support this interpretation.
△ Less
Submitted 14 June, 2017;
originally announced June 2017.
-
Integral field spectroscopy of HII regions in M33
Authors:
Jesús López-Hernández,
Elena Terlevich,
Roberto Terlevich,
Daniel Rosa-González,
Ángeles Díaz,
Rubén García Benito,
José Vílchez,
Guillermo Hägele
Abstract:
Integral field spectroscopy (IFS) is presented for star forming regions in M33. A central area of 300 x 500 pc^2 and the external HII region IC 132, at a galactocentric distance {\sim} 19arcmin (4.69 kpc) were observed with the Potsdam Multi Aperture Spectrophotometer (PMAS) instrument at the 3.5 m telescope of the Calar Alto Hispano- Alemán observatory (CAHA). The spectral coverage goes from 3600…
▽ More
Integral field spectroscopy (IFS) is presented for star forming regions in M33. A central area of 300 x 500 pc^2 and the external HII region IC 132, at a galactocentric distance {\sim} 19arcmin (4.69 kpc) were observed with the Potsdam Multi Aperture Spectrophotometer (PMAS) instrument at the 3.5 m telescope of the Calar Alto Hispano- Alemán observatory (CAHA). The spectral coverage goes from 3600 A to 1μm to include from [OII]λ3727 A to the near infrared lines required for deriving sulphur electron temperature and abundance diagnostics. Local conditions within individual HII regions are presented in the form of emission line fluxes and physical conditions for each spatial resolution element (spaxel) and for segments with similar Hα surface brightness. A clear dichotomy is observed when comparing the central to outer disc HII regions. While the external HII region has higher electron temperature plus larger Hβ equivalent width, size and excitation, the central region has higher extinction and metal content. The dichotomy extends to the BPT diagnostic diagrams that show two orthogonal broad distributions of points. By comparing with pseudo-3D photoionization models we conclude that the bulk observed differences are probably related to a different ionization parameter and metallicity. Wolf-Rayet features are detected in IC 132, and resolved into two concentrations whose integrated spectra were used to estimate the characteristic number of WR stars. No WR features were detected in the central HII regions despite their higher metallicity.
△ Less
Submitted 27 December, 2012;
originally announced December 2012.