-
Automated Grain Boundary Detection for Bright-Field Transmission Electron Microscopy Images via U-Net
Authors:
Matthew J. Patrick,
James K. Eckstein,
Javier R. Lopez,
Silvia Toderas,
Sarah A. Asher,
Sylvia I. Whang,
Stacey Levine,
Jeffrey M. Rickman,
Katayun Barmak
Abstract:
Quantification of microstructures is crucial for understanding processing-structure and structure-property relationships in polycrystalline materials. Delineating grain boundaries in bright-field transmission electron micrographs, however, is challenging due to complex diffraction contrast in images. Conventional edge detection algorithms are inadequate; instead, manual tracing is usually required…
▽ More
Quantification of microstructures is crucial for understanding processing-structure and structure-property relationships in polycrystalline materials. Delineating grain boundaries in bright-field transmission electron micrographs, however, is challenging due to complex diffraction contrast in images. Conventional edge detection algorithms are inadequate; instead, manual tracing is usually required. This study demonstrates the first successful machine-learning approach for grain-boundary detection in bright-field transmission electron micrographs. The proposed methodology uses a U-Net convolutional neural network trained on carefully constructed data from bright-field images and hand-tracings available from prior studies, combined with targeted post-processing algorithms to preserve fine features of interest. The image processing pipeline accurately estimates grain-boundary positions, avoiding segmentation in regions with intragrain contrast and identifying low-contrast boundaries. Our approach is validated by directly comparing microstructural markers (i.e., grain centroids) identified in U-Net predictions with those identified in hand tracings; furthermore, the grain size distributions obtained from the two techniques show notable overlap when compared using t-, Kolmogorov-Smirnov, and Cramer-von Mises tests. The technique is then successfully applied to interpret new aluminum film microstructures having different image characteristics from the training data, and preliminary results from Pt and Pd microstructures are presented, highlighting the versatility of our approach for grain-boundary identification in bright-field micrographs.
△ Less
Submitted 14 December, 2023;
originally announced December 2023.
-
Medipix3 for dosimetry and real-time beam monitoring: first tests at a 60 MeV proton therapy facility
Authors:
J. S. L. Yap,
N. J. S. Bal,
A. Kacperek,
J. Resta López,
C. P. Welsch
Abstract:
Charged particle therapy (CPT) is an advanced modality of radiation therapy which has grown rapidly worldwide, driven by recent developments in technology and methods of delivery. To ensure safe and high quality treatments, various instruments are used for a range of different measurements such as for quality assurance, monitoring and dosimetry purposes. With the emergence of new and enhanced deli…
▽ More
Charged particle therapy (CPT) is an advanced modality of radiation therapy which has grown rapidly worldwide, driven by recent developments in technology and methods of delivery. To ensure safe and high quality treatments, various instruments are used for a range of different measurements such as for quality assurance, monitoring and dosimetry purposes. With the emergence of new and enhanced delivery techniques, systems with improved capabilities are needed to exceed existing performance limitations of conventional tools. The Medipix3 is a hybrid pixel detector able to count individual protons with millisecond time resolution at clinical flux with near instant readout and count rate linearity. The system has previously demonstrated use in medical and other applications, showing wide versatility and potential for particle therapy. In this work we present measurements of the Medipix3 detector in the 60 MeV ocular proton therapy beamline at the Clatterbridge Cancer Centre, UK. The beam current and lateral beam profiles were evaluated at multiple positions in the treatment line and compared with EBT3 Gafchromic film. The recorded count rate linearity and temporal analysis of the beam structure was measured with Medipix3 across the full range of available beam intensities, up to $3.12 \times 10^{10}$ protons/s. We explore the capacity of Medipix3 to provide non-reference measurements and its applicability as a tool for dosimetry and beam monitoring for CPT. This is the first known time the performance of the Medipix3 detector technology has been tested within a clinical, high proton flux environment.
△ Less
Submitted 15 September, 2021; v1 submitted 5 July, 2021;
originally announced July 2021.
-
Efficient processing of raster and vector data
Authors:
Fernando Silva-Coira,
José R. Paramá,
Susana Ladra,
Juan R. López,
Gilberto Gutiérrez
Abstract:
In this work, we propose a framework to store and manage spatial data, which includes new efficient algorithms to perform operations accepting as input a raster dataset and a vector dataset. More concretely, we present algorithms for solving a spatial join between a raster and a vector dataset imposing a restriction on the values of the cells of the raster; and an algorithm for retrieving K object…
▽ More
In this work, we propose a framework to store and manage spatial data, which includes new efficient algorithms to perform operations accepting as input a raster dataset and a vector dataset. More concretely, we present algorithms for solving a spatial join between a raster and a vector dataset imposing a restriction on the values of the cells of the raster; and an algorithm for retrieving K objects of a vector dataset that overlap cells of a raster dataset, such that the K objects are those overlap** the highest (or lowest) cell values among all objects. The raster data is stored using a compact data structure, which can directly manipulate compressed data without the need for prior decompression. This leads to better running times and lower memory consumption. In our experimental evaluation comparing our solution to other baselines, we obtain the best space/time trade-offs.
△ Less
Submitted 6 April, 2020; v1 submitted 26 December, 2019;
originally announced December 2019.
-
Degree theory for discontinuous operators
Authors:
Rubén Figueroa,
Rodrigo López Pouso,
Jorge Rodríguez López
Abstract:
We introduce a new definition of topological degree for a meaningful class of operators which need not be continuous. Subsequently, we derive a number of fixed point theorems for such operators. As an application, we deduce a new existence result for first-order ODEs with discontinuous nonlinearities.
We introduce a new definition of topological degree for a meaningful class of operators which need not be continuous. Subsequently, we derive a number of fixed point theorems for such operators. As an application, we deduce a new existence result for first-order ODEs with discontinuous nonlinearities.
△ Less
Submitted 9 January, 2017;
originally announced January 2017.
-
Latest Beam Test Results of the FONT4 ILC Intra-train Feedback System Prototype
Authors:
P. N. Burrows,
R. Apsimon,
G. B. Christian,
C. Clarke,
B. Constance,
H. Dabiri Khah,
T. Hartin,
A. Kalinin,
C. Perry,
J. Resta Lopez,
C. Swinson
Abstract:
We present the design and preliminary results of a prototype beam-based digital feedback system for the Interaction Point of the International Linear Collider. A custom analogue front-end processor, FPGA-based digital signal processing board, and kicker drive amplifier have been designed, built, and tested on the extraction line of the KEK Accelerator Test Facility (ATF). The system was measured…
▽ More
We present the design and preliminary results of a prototype beam-based digital feedback system for the Interaction Point of the International Linear Collider. A custom analogue front-end processor, FPGA-based digital signal processing board, and kicker drive amplifier have been designed, built, and tested on the extraction line of the KEK Accelerator Test Facility (ATF). The system was measured to have a latency of approximately 140 ns.
△ Less
Submitted 4 March, 2009;
originally announced March 2009.