-
Thermal analysis of Josephson junctions array in cryocooler
Authors:
P. Durandetto,
E. Monticone,
B. Trinchera,
L. Lolli,
D. Serazio,
M. Fretto,
A. Sosso
Abstract:
Complex cryogenics is still a strong limitation to the spread of quantum voltage standards and cryogen-free operation is then particularly interesting for Josephson standards. The main difficulties in He-free refrigeration are related to chip thermalization. We tested different solutions and interface materials between the chip and the cooling surface, to improve thermal conduction. Some junctions…
▽ More
Complex cryogenics is still a strong limitation to the spread of quantum voltage standards and cryogen-free operation is then particularly interesting for Josephson standards. The main difficulties in He-free refrigeration are related to chip thermalization. We tested different solutions and interface materials between the chip and the cooling surface, to improve thermal conduction. Some junctions were chosen as elements to dissipate electrical power, while some others were operated as on-chip temperature sensors. Indium foil between chip and Cu support was demonstrated to provide a good thermal interface suitable for programmable voltage standard operation. However, thermal conduction can be further increased by thermal contacting the chip at the top. Finally, general physical constraints in vacuum thermal contacts are analyzed in terms of known properties of thermal interfaces at cryogenics temperatures.
△ Less
Submitted 30 August, 2017; v1 submitted 12 September, 2016;
originally announced September 2016.
-
Towards joint reconstruction of noise and losses in quantum channels
Authors:
F. Piacentini,
A. Avella,
P. Traina,
L. Lolli,
E. Taralli,
E. Monticone,
M. Rajteri,
D. Fukuda,
I. P. Degiovanni,
G. Brida
Abstract:
The calibration of a quantum channel, i.e. the determination of the transmission losses affecting it, is definitely one of the principal objectives in both the quantum communication and quantum metrology frameworks. Another task of the utmost relevance is the identification, e.g. by extracting its photon number distribution, of the noise potentially present in the channel. Here we present a protoc…
▽ More
The calibration of a quantum channel, i.e. the determination of the transmission losses affecting it, is definitely one of the principal objectives in both the quantum communication and quantum metrology frameworks. Another task of the utmost relevance is the identification, e.g. by extracting its photon number distribution, of the noise potentially present in the channel. Here we present a protocol, based on the response of a photon-number-resolving detector at different quantum efficiencies, able to accomplish both of these tasks at once, providing with a single measurement an estimate of the transmission losses as well as the photon statistics of the noise present in the exploited quantum channel. We show and discuss the experimental results obtained in the practical implementation of such protocol, with different kinds and levels of noise.
△ Less
Submitted 29 February, 2016;
originally announced February 2016.
-
High intrinsic energy resolution photon number resolving detectors
Authors:
L. Lolli,
E. Taralli,
C. Portesi,
E. Monticone,
M. Rajteri
Abstract:
Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon detector for quantum technology experiments. For a TES based on titanium and gold has been reached, at telecommunication wavelength, an unprecedented intrinsic energy…
▽ More
Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon detector for quantum technology experiments. For a TES based on titanium and gold has been reached, at telecommunication wavelength, an unprecedented intrinsic energy resolution (0.113 eV). The uncertainties analysis of both energy resolution and photon state assignment has been discussed. The thermal properties of the superconductive device have been studied by fitting the bias curve to evaluate theoretical limit of the energy resolution.
△ Less
Submitted 23 June, 2013;
originally announced June 2013.
-
Quantum and classical characterization of single/few photon detectors
Authors:
M. G. Mingolla,
F. Piacentini,
A. Avella,
M. Gramegna,
L. Lolli,
A. Meda,
I. Ruo Berchera,
E. Taralli,
P. Traina,
M. Rajteri,
G. Brida,
I. P. Degiovanni,
M. Genovese
Abstract:
This paper's purpose is to review the results recently obtained in the Quantum Optics labs of the National Institute of Metrological Research (INRIM) in the field of single- and few-photon detectors calibration, from both the classical and quantum viewpoint. In the first part of the paper is presented the calibration of a single-photon detector with absolute methods, while in the second part we fo…
▽ More
This paper's purpose is to review the results recently obtained in the Quantum Optics labs of the National Institute of Metrological Research (INRIM) in the field of single- and few-photon detectors calibration, from both the classical and quantum viewpoint. In the first part of the paper is presented the calibration of a single-photon detector with absolute methods, while in the second part we focus on photon-number-resolving detectors, discussing both the classical and quantum characterization of such devices.
△ Less
Submitted 24 May, 2013;
originally announced May 2013.
-
Self consistent, absolute calibration technique for photon number resolving detectors
Authors:
A. Avella,
G. Brida,
I. P. Degiovanni,
M. Genovese,
M. Gramegna,
L. Lolli,
E. Monticone,
C. Portesi,
M. Rajteri,
M. L. Rastello,
E. Taralli,
P. Traina,
M. White
Abstract:
Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pul…
▽ More
Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pulsed heralded photon source based on parametric down conversion. The technique, being absolute, does not require reference standards and is independent upon the performances of the heralding detector. The method provides the results of quantum efficiency for the heralded detector as a function of detected photon numbers. Furthermore, we prove its validity by performing the calibration of a Transition Edge Sensor based detector, a real photon number resolving detector that has recently demonstrated its effectiveness in various quantum information protocols.
△ Less
Submitted 16 November, 2011;
originally announced November 2011.
-
Quantum characterization of superconducting photon counters
Authors:
Giorgio Brida,
Luigi Ciavarella,
Ivo P. Degiovanni,
Marco Genovese,
Lapo Lolli,
Maria G. Mingolla,
Fabrizio Piacentini,
Mauro Rajteri,
Emanuele Taralli,
Matteo G. A. Paris
Abstract:
We address the quantum characterization of photon counters based on transition-edge sensors (TESs) and present the first experimental tomography of the positive operator-valued measure (POVM) of a TES. We provide the reliable tomographic reconstruction of the POVM elements up to 11 detected photons and M=100 incoming photons, demonstrating that it is a linear detector.
We address the quantum characterization of photon counters based on transition-edge sensors (TESs) and present the first experimental tomography of the positive operator-valued measure (POVM) of a TES. We provide the reliable tomographic reconstruction of the POVM elements up to 11 detected photons and M=100 incoming photons, demonstrating that it is a linear detector.
△ Less
Submitted 3 May, 2012; v1 submitted 15 March, 2011;
originally announced March 2011.
-
Experimental study of high energy electron interactions in a superconducting aluminum alloy resonant bar
Authors:
M. Barucci,
M. Bassan,
B. Buonomo,
G. Cavallari,
E. Coccia,
S. D'Antonio,
V. Fafone,
C. Ligi,
L. Lolli,
A. Marini,
G. Mazzitelli,
G. Modestino,
G. Pizzella,
L. Quintieri,
L. Risegari,
A. Rocchi,
F. Ronga,
P. Valente,
G. Ventura,
S. M. Vinko
Abstract:
Peak amplitude measurements of the fundamental mode of oscillation of a suspended aluminum alloy bar hit by an electron beam show that the amplitude is enhanced by a factor ~3.5 when the material is in the superconducting state. This result is consistent with the cosmic ray observations made by the resonant gravitational wave detector NAUTILUS, made of the same alloy, when operated in the superc…
▽ More
Peak amplitude measurements of the fundamental mode of oscillation of a suspended aluminum alloy bar hit by an electron beam show that the amplitude is enhanced by a factor ~3.5 when the material is in the superconducting state. This result is consistent with the cosmic ray observations made by the resonant gravitational wave detector NAUTILUS, made of the same alloy, when operated in the superconducting state. A comparison of the experimental data with the predictions of the model describing the underlying physical process is also presented.
△ Less
Submitted 9 January, 2009;
originally announced January 2009.