-
A definition of the SI second based on several optical transitions
Authors:
Jérôme Lodewyck
Abstract:
A new definition of the SI second based on optical transitions is expected to be adopted within the next 10 years. Several options for this redefinition are currently under consideration. Among them, a definition based on several transitions would take advantage of the variety of high performance optical frequency standards. In this paper, we review practical aspects such a definition entails, and…
▽ More
A new definition of the SI second based on optical transitions is expected to be adopted within the next 10 years. Several options for this redefinition are currently under consideration. Among them, a definition based on several transitions would take advantage of the variety of high performance optical frequency standards. In this paper, we review practical aspects such a definition entails, and propose a detailed analysis of its strengths and weaknesses.
△ Less
Submitted 11 July, 2024;
originally announced July 2024.
-
Roadmap towards the redefinition of the second
Authors:
N. Dimarcq,
M. Gertsvolf,
G. Mileti,
S. Bize,
C. W. Oates,
E. Peik,
D. Calonico,
T. Ido,
P. Tavella,
F. Meynadier,
G. Petit,
G. Panfilo,
J. Bartholomew,
P. Defraigne,
E. A. Donley,
P. O. Hedekvist,
I. Sesia,
M. Wouters,
P. Dube,
F. Fang,
F. Levi,
J. Lodewyck,
H. S. Margolis,
D. Newell,
S. Slyusarev
, et al. (12 additional authors not shown)
Abstract:
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the ne…
▽ More
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the necessary level of uncertainty are discussed. In addition, the mandatory criteria to be achieved before redefinition and their current fulfilment level, together with the redefinition options based on a single or on a set of transitions are described.
△ Less
Submitted 26 July, 2023;
originally announced July 2023.
-
Search for vector dark matter in microwave cavities with Rydberg atoms
Authors:
Jordan Gué,
Aurélien Hees,
Jérôme Lodewyck,
Rodolphe Le Targat,
Peter Wolf
Abstract:
We propose a novel experiment to search for dark matter, based on the application of an electric field inside a microwave cavity and electrometry using Rydberg atoms. We show that this kind of experiment could be extremely useful for detecting specific dark matter candidates, namely massive vector fields coupled to the photon field, more commonly known as dark photons. Such a massive vector field…
▽ More
We propose a novel experiment to search for dark matter, based on the application of an electric field inside a microwave cavity and electrometry using Rydberg atoms. We show that this kind of experiment could be extremely useful for detecting specific dark matter candidates, namely massive vector fields coupled to the photon field, more commonly known as dark photons. Such a massive vector field is a good candidate for dark matter. Using realistic experimental parameters we show that such an experiment could improve the current constraint on the coupling constant of the dark photons to Standard Model photons in the 1~$μ$eV to 10~$μ$eV mass range, with the possibility of tuning the maximum sensitivity via the cavity size. The main limiting factors on the sensitivity of the experiment are the amplitude stability of the applied field and the measurement uncertainty of the electric field by the atoms.
△ Less
Submitted 11 August, 2023; v1 submitted 19 May, 2023;
originally announced May 2023.
-
Improving Short-Term Stability in Optical Lattice Clocks by Quantum Nondemolition Measurements
Authors:
Daniel Benedicto Orenes,
Robert J. Sewell,
Jérôme Lodewyck,
Morgan W. Mitchell
Abstract:
We propose a multimeasurement estimation protocol for Quantum Nondemolition (QND) measurements in a Rabi clock interferometer. The method is well suited for current state-of-the-art optical lattice clocks with QND measurement capabilities. The protocol exploits the correlations between multiple non-destructive measurements of the initially prepared coherent spin state. A suitable Gaussian estimato…
▽ More
We propose a multimeasurement estimation protocol for Quantum Nondemolition (QND) measurements in a Rabi clock interferometer. The method is well suited for current state-of-the-art optical lattice clocks with QND measurement capabilities. The protocol exploits the correlations between multiple non-destructive measurements of the initially prepared coherent spin state. A suitable Gaussian estimator for the clock laser detuning is presented, and an analytic expression for the sensitivity of the protocol is derived. We use this analytic expression to optimise the protocol using available experimental parameters, achieving an improvement of $7.9$dB with respect to the standard quantum limit (SQL) in terms of clock stability. We also discuss the measurement back-action effects of our protocol into the atomic state.
△ Less
Submitted 17 May, 2022; v1 submitted 17 September, 2021;
originally announced September 2021.
-
Universal formalism for data sharing and processing in clock comparison networks
Authors:
Jérôme Lodewyck,
Rodolphe Le Targat,
Paul-Eric Pottie,
Erik Benkler,
Sebastian Koke,
Jochen Kronjäger
Abstract:
We present a mathematical framework adapted to the comparison of atomic clocks remotely connected by a complex network of optical or microwave links. This framework facilitates the computation of frequency ratios using a generic set of equations that are valid for a wide variety of clock architectures, making the comparison of a large number of clocks practical. This formalism suggests a generic d…
▽ More
We present a mathematical framework adapted to the comparison of atomic clocks remotely connected by a complex network of optical or microwave links. This framework facilitates the computation of frequency ratios using a generic set of equations that are valid for a wide variety of clock architectures, making the comparison of a large number of clocks practical. This formalism suggests a generic data exchange protocol that can be used in clock comparison collaborations, for which data logging and decision taking are completely local procedures, independently implemented by the participants.
△ Less
Submitted 23 November, 2020; v1 submitted 20 October, 2020;
originally announced October 2020.
-
On a definition of the SI second with a set of optical clock transitions
Authors:
Jérôme Lodewyck
Abstract:
The current SI second based on the atomic hyperfine transition in the ground state of 133Cs is expected to be replaced by a new definition based on optical frequency standards, whose estimated uncertainty has now been established two orders of magnitude lower than the accuracy of the best Cs primary standards. However, such a redefinition of the second is hindered by the fact that many atomic spec…
▽ More
The current SI second based on the atomic hyperfine transition in the ground state of 133Cs is expected to be replaced by a new definition based on optical frequency standards, whose estimated uncertainty has now been established two orders of magnitude lower than the accuracy of the best Cs primary standards. However, such a redefinition of the second is hindered by the fact that many atomic species are potential contenders to become the new primary frequency standard. In this paper, we propose to resolve this issue by defining a composite frequency unit based on the weighted geometric mean of the individual frequencies of different atomic transitions. This unit has the property to be realisable with any single clock whose transition composes the unit, provided that at least a few frequency ratios are available, with an accuracy that marginally differs from the nominal clock uncertainty. We show that the unit can be updated as the performances of the contributing transitions evolve, without incurring a drift on the unit itself.
△ Less
Submitted 13 November, 2019;
originally announced November 2019.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Guidelines for develo** optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups develo** optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trap**, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
First observation with global network of optical atomic clocks aimed for a dark matter detection
Authors:
P. Wcisło,
P. Ablewski,
K. Beloy,
S. Bilicki,
M. Bober,
R. Brown,
R. Fasano,
R. Ciuryło,
H. Hachisu,
T. Ido,
J. Lodewyck,
A. Ludlow,
W. McGrew,
P. Morzyński,
D. Nicolodi,
M. Schioppo,
M. Sekido,
R. Le Targat,
P. Wolf,
X. Zhang,
B. Zjawin,
M. Zawada
Abstract:
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comp…
▽ More
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comparisons of the clocks. We report a two orders of magnitude improvement in constraints on transient variations of the fine-structure constant, which considerably improves the detection limit for the standard model (SM) - DM coupling. We use Yb and Sr optical atomic clocks at four laboratories on three continents to search for both topological defect (TD) and massive scalar field candidates. No signal consistent with a dark-matter coupling is identified, leading to significantly improved constraints on the DM-SM couplings.
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
A noise-immune cavity-assisted non-destructive detection for an optical lattice clock in the quantum regime
Authors:
G. Vallet,
E. Bookjans,
U. Eismann,
S. Bilicki,
R. Le Targat,
J. Lodewyck
Abstract:
We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms enhanced by a high finesse cavity. By design, this scheme offers a 1st order rejection of the technical noise sources, an enhanced signal-to-noise ratio, and a…
▽ More
We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms enhanced by a high finesse cavity. By design, this scheme offers a 1st order rejection of the technical noise sources, an enhanced signal-to-noise ratio, and an homogeneous atom-cavity coupling. We theoretically show that this scheme is optimal with respect to the photon shot noise limit. We experimentally realize this detection scheme in an operational strontium optical lattice clock. The resolution is on the order of a few atoms with a photon scattering rate low enough to keep the atoms trapped after detection. This scheme opens the door to various different interrogations protocols, which reduce the frequency instability, including atom recycling, zero-dead time clocks with a fast repetition rate, and sub quantum projection noise frequency stability.
△ Less
Submitted 14 March, 2017;
originally announced March 2017.
-
Test of special relativity using a fiber network of optical clocks
Authors:
P. Delva,
J. Lodewyck,
S. Bilicki,
E. Bookjans,
G. Vallet,
R. Le Targat,
P. -E. Pottie,
C. Guerlin,
F. Meynadier,
C. Le Poncin-Lafitte,
O. Lopez,
A. Amy-Klein,
W. -K. Lee,
N. Quintin,
C. Lisdat,
A. Al-Masoudi,
S. Dörscher,
C. Grebing,
G. Grosche,
A. Kuhl,
S. Raupach,
U. Sterr,
I. R. Hill,
R. Hobson,
W. Bowden
, et al. (6 additional authors not shown)
Abstract:
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted…
▽ More
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.
△ Less
Submitted 12 June, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Authors:
Jérôme Lodewyck,
Sławomir Bilicki,
Eva Bookjans,
Jean-Luc Robyr,
Chunyan Shi,
Grégoire Vallet,
Rodolphe Le Targat,
Daniele Nicolodi,
Yann Le Coq,
Jocelyne Guéna,
Michel Abgrall,
Peter Rosenbusch,
Sébastien Bize
Abstract:
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached th…
▽ More
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.
△ Less
Submitted 12 May, 2016;
originally announced May 2016.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
S. Origlia,
S. Schiller,
M. S. Pramod,
L. Smith,
Y. Singh,
W. He,
S. Viswam,
D. Świerad,
J. Hughes,
K. Bongs,
U. Sterr,
Ch. Lisdat,
S. Vogt,
S. Bize,
J. Lodewyck,
R. Le Targat,
D. Holleville,
B. Venon,
P. Gill,
G. Barwood,
I. R. Hill,
Y. Ovchinnikov,
A. Kulosa,
W. Ertmer,
E. -M. Rasel
, et al. (3 additional authors not shown)
Abstract:
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than…
▽ More
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.
△ Less
Submitted 19 March, 2016;
originally announced March 2016.
-
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Authors:
R Tyumenev,
M Favier,
S Bilicki,
E Bookjans,
R Le Targat,
J Lodewyck,
D Nicolodi,
Y Le Coq,
M Abgrall,
J Guéna,
L De Sarlo,
S Bize
Abstract:
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (sta…
▽ More
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (statistical) $\pm\,0.38\,$Hz (systematic), limited solely by the realization of the SI second. Furthermore, by comparing the mercury optical lattice clock to a Rb atomic fountain, we determine for the first time to our knowledge the ratio between the $^{199}$Hg clock transition and the $^{87}$Rb ground state hyperfine transition. Finally we present a direct optical to optical measurement of the $^{199}$Hg/$^{87}$Sr frequency ratio. The obtained value of $ν_{\mathrm{Hg}}/ν_{\mathrm{Sr}}=2.629\,314\,209\,898\,909\,15$ with a fractional uncertainty of $1.8\times10^{-16}$ is in excellent agreement with the same measurement obtained by Yamanaka et al. (arXiv:1503.07941). This makes this frequency ratio one of the few physical quantities agreed upon by different laboratories to this level of uncertainty. Frequency ratio measurements of the kind of those reported in this paper have a strong impact for frequency metrology but also for fundamental physics as they can be used to monitor putative variations of fundamental constants.
△ Less
Submitted 13 November, 2016; v1 submitted 7 March, 2016;
originally announced March 2016.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Atomic fountains and optical clocks at SYRTE: status and perspectives
Authors:
M. Abgrall,
B. Chupin,
L. De Sarlo,
J. Guéna,
Ph. Laurent,
Y. Le Coq,
R. Le Targat,
J. Lodewyck,
M. Lours,
P. Rosenbusch,
D. Rovera,
S. Bize
Abstract:
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekee**. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on w…
▽ More
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekee**. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on work relevant to a future possible redefinition of the SI second.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
Polarizabilities of the 87Sr Clock Transition
Authors:
C Shi,
J. -L Robyr,
U Eismann,
M Zawada,
L Lorini,
R Le Targat,
J Lodewyck
Abstract:
In this paper, we propose an in-depth review of the vector and tensor polarizabilities of the two energy levels of the 87Sr clock transition whose measurement was reported in [P. G. Westergaard et al., Phys. Rev. Lett. 106, 210801 (2011)]. We conduct a theoretical calculation that reproduces the measured coefficients. In addition, we detail the experimental conditions used for their measurement in…
▽ More
In this paper, we propose an in-depth review of the vector and tensor polarizabilities of the two energy levels of the 87Sr clock transition whose measurement was reported in [P. G. Westergaard et al., Phys. Rev. Lett. 106, 210801 (2011)]. We conduct a theoretical calculation that reproduces the measured coefficients. In addition, we detail the experimental conditions used for their measurement in two Sr optical lattice clocks, and exhibit the quadratic behaviour of the vector and tensor shifts with the depth of the trap** potential and evaluate their impact on the accuracy of the clock.
△ Less
Submitted 31 March, 2015;
originally announced March 2015.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
K. Bongs,
Y. Singh,
L. Smith,
W. He,
O. Kock,
D. Swierad,
J. Hughes,
S. Schiller,
S. Alighanbari,
S. Origlia,
S. Vogt,
U. Sterr,
Ch. Lisdat,
R. Le Targat,
J. Lodewyck,
D. Holleville,
B. Venon,
S. Bize,
G. P. Barwood,
P. Gill,
I. R. Hill,
Y. B. Ovchinnikov,
N. Poli,
G. M. Tino,
J. Stuhler
, et al. (2 additional authors not shown)
Abstract:
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at l…
▽ More
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.
△ Less
Submitted 29 March, 2015;
originally announced March 2015.
-
Atomic clocks: new prospects in metrology and geodesy
Authors:
Pacôme Delva,
Jérôme Lodewyck
Abstract:
We present the latest developments in the field of atomic clocks and their applications in metrology and fundamental physics. In the light of recent advents in the accuracy of optical clocks, we present an introduction to the relativistic modelization of frequency transfer and a detailed review of chronometric geodesy.
We present the latest developments in the field of atomic clocks and their applications in metrology and fundamental physics. In the light of recent advents in the accuracy of optical clocks, we present an introduction to the relativistic modelization of frequency transfer and a detailed review of chronometric geodesy.
△ Less
Submitted 29 August, 2013;
originally announced August 2013.
-
Experimenting an optical second with strontium lattice clocks
Authors:
R. Le Targat,
L. Lorini,
Y. Le Coq,
M. Zawada,
J. Guéna,
M. Abgrall,
M. Gurov,
P. Rosenbusch,
D. G. Rovera,
B. Nagórny,
R. Gartman,
P. G. Westergaard,
M. E. Tobar,
M. Lours,
G. Santarelli,
A. Clairon,
S. Bize,
P. Laurent,
P. Lemonde,
J. Lodewyck
Abstract:
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat…
▽ More
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.
△ Less
Submitted 31 July, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
Authors:
S. Schiller,
A. Görlitz,
A. Nevsky,
S. Alighanbari,
S. Vasilyev,
C. Abou-Jaoudeh,
G. Mura,
T. Franzen,
U. Sterr,
S. Falke,
Ch. Lisdat,
E. Rasel,
A. Kulosa,
S. Bize,
J. Lodewyck,
G. M. Tino,
N. Poli,
M. Schioppo,
K. Bongs,
Y. Singh,
P. Gill,
G. Barwood,
Y. Ovchinnikov,
J. Stuhler,
W. Kaenders
, et al. (6 additional authors not shown)
Abstract:
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (map** of the gravitational potential of Earth), and astronomy (providing local oscillators for radio…
▽ More
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (map** of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.
△ Less
Submitted 17 June, 2012;
originally announced June 2012.
-
Observation and cancellation of the dc Stark shift in strontium optical lattice clocks
Authors:
Jérôme Lodewyck,
Michal Zawada,
Luca Lorini,
Mikhail Gurov,
Pierre Lemonde
Abstract:
We report on the observation of a dc Stark frequency shift at the $10^{-13}$ level by comparing two strontium optical lattice clocks. This frequency shift arises from the presence of electric charges trapped on dielectric surfaces placed under vacuum close to the atomic sample. We show that these charges can be eliminated by shining UV light on the dielectric surfaces, and characterize the residua…
▽ More
We report on the observation of a dc Stark frequency shift at the $10^{-13}$ level by comparing two strontium optical lattice clocks. This frequency shift arises from the presence of electric charges trapped on dielectric surfaces placed under vacuum close to the atomic sample. We show that these charges can be eliminated by shining UV light on the dielectric surfaces, and characterize the residual dc Stark frequency shift on the clock transition at the $10^{-18}$ level by applying an external electric field. This study shows that the dc Stark shift can play an important role in the accuracy budget of lattice clocks, and should be duly taken into account.
△ Less
Submitted 22 August, 2011;
originally announced August 2011.
-
Lattice Induced Frequency Shifts in Sr Optical Lattice Clocks at the $10^{-17}$ Level
Authors:
Philip G. Westergaard,
Jérôme Lodewyck,
Luca Lorini,
Arnaud Lecallier,
Eric Burt,
Michal Zawada,
Jacques Millo,
Pierre Lemonde
Abstract:
We present a comprehensive study of the frequency shifts associated with the lattice potential for a Sr lattice clock. By comparing two such clocks with a frequency stability reaching $5\times 10^{-17}$ after a one hour integration time, and varying the lattice depth up to $U_0=900 \, E_r$ with $E_r$ being the recoil energy, we evaluate lattice related shifts with an unprecedented accuracy. We put…
▽ More
We present a comprehensive study of the frequency shifts associated with the lattice potential for a Sr lattice clock. By comparing two such clocks with a frequency stability reaching $5\times 10^{-17}$ after a one hour integration time, and varying the lattice depth up to $U_0=900 \, E_r$ with $E_r$ being the recoil energy, we evaluate lattice related shifts with an unprecedented accuracy. We put the first experimental upper bound on the recently predicted frequency shift due to the magnetic dipole (M1) and electric quadrupole (E2) interactions. This upper bound is significantly smaller than the theoretical upper limit. We also give a new upper limit on the effect of hyperpolarizability with an improvement by more than one order of magnitude. Finally, we report the first observation of the vector and tensor shifts in a lattice clock. Combining these measurements, we show that all known lattice related perturbation will not affect the clock accuracy down to the $10^{-17}$ level, even for very deep lattices, up to $U_0=150\,E_r$.
△ Less
Submitted 9 February, 2011;
originally announced February 2011.
-
Minimizing the Dick Effect in an Optical Lattice Clock
Authors:
Philip G. Westergaard,
Jerome Lodewyck,
Pierre Lemonde
Abstract:
We discuss the minimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a non-destructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to stron…
▽ More
We discuss the minimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a non-destructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2E-16$τ^{-1/2}$ for the lattice clock.
△ Less
Submitted 5 September, 2009; v1 submitted 4 September, 2009;
originally announced September 2009.
-
Non-destructive measurement of the transition probability in a Sr optical lattice clock
Authors:
Jerome Lodewyck,
Philip G. Westergaard,
Pierre Lemonde
Abstract:
We present the experimental demonstration of non-destructive probing of the 1S0-3P0 clock transition probability in an optical lattice clock with 87Sr atoms. It is based on the phase shift induced by the atoms on a weak off-resonant laser beam. The method we propose is a differential measurement of this phase shift on two modulation sidebands with opposite detuning with respect to the 1S0-1P1 tr…
▽ More
We present the experimental demonstration of non-destructive probing of the 1S0-3P0 clock transition probability in an optical lattice clock with 87Sr atoms. It is based on the phase shift induced by the atoms on a weak off-resonant laser beam. The method we propose is a differential measurement of this phase shift on two modulation sidebands with opposite detuning with respect to the 1S0-1P1 transition, allowing a detection limited by the photon shot noise. We have measured an atomic population of 10^4 atoms with a signal to noise ratio of 100 per cycle, while kee** more than 95% of the atoms in the optical lattice with a depth of 0.1 mK. The method proves simple and robust enough to be operated as part of the whole clock setup. This detection scheme enables us to reuse atoms for subsequent clock state interrogations, dramatically reducing the loading time and thereby improving the clock frequency stability.
△ Less
Submitted 17 February, 2009;
originally announced February 2009.
-
Ultrastable lasers based on vibration insensitive cavities
Authors:
J. Millo,
D. V. Magalhaes,
C. Mandache,
Y. Le Coq,
E. M. L. English,
P. G. Westergaard,
J. Lodewyck,
S. Bize,
P. Lemonde,
G. Santarelli
Abstract:
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better…
▽ More
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better than 1.5e-11 per m.s^-2 for each spatial direction, which shows significant improvement over previous studies. We have tested the very low dependence on the position of the cavity support points, in order to establish that our designs eliminate the need for fine tuning to achieve extremely low vibration sensitivity. Relative frequency measurements show that at least one of the stabilized lasers has a stability better than 5.6e-16 at 1 second, which is the best result obtained for this length of cavity.
△ Less
Submitted 4 May, 2009; v1 submitted 29 January, 2009;
originally announced January 2009.
-
Quantum key distribution over 25 km with an all-fiber continuous-variable system
Authors:
Jerome Lodewyck,
Matthieu Bloch,
Raul Garcia-Patron,
Simon Fossier,
Evgueni Karpov,
Eleni Diamanti,
Thierry Debuisschert,
Nicolas J. Cerf,
Rosa Tualle-Brouri,
Steven W. McLaughlin,
Philippe Grangier
Abstract:
We report on the implementation of a reverse-reconciliated coherent-state continuous-variable quantum key distribution system, with which we generated secret keys at a rate of more than 2 kb/s over 25 km of optical fiber. Time multiplexing is used to transmit both the signal and phase reference in the same optical fiber. Our system includes all experimental aspects required for a field implement…
▽ More
We report on the implementation of a reverse-reconciliated coherent-state continuous-variable quantum key distribution system, with which we generated secret keys at a rate of more than 2 kb/s over 25 km of optical fiber. Time multiplexing is used to transmit both the signal and phase reference in the same optical fiber. Our system includes all experimental aspects required for a field implementation of a quantum key distribution setup. Real-time reverse reconciliation is achieved by using fast and efficient LDPC error correcting codes.
△ Less
Submitted 4 September, 2007; v1 submitted 28 June, 2007;
originally announced June 2007.
-
Tight bound on coherent states quantum key distribution with heterodyne detection
Authors:
Jerome Lodewyck,
Philippe Grangier
Abstract:
We propose a new upper bound for the eavesdropper's information in the direct and reverse reconciliated coherent states quantum key distribution protocols with heterodyne detection. This bound is derived by maximizing the leaked information over the symplectic group of transformations that spans every physical Gaussian attack on individual pulses. We exhibit four different attacks that reach thi…
▽ More
We propose a new upper bound for the eavesdropper's information in the direct and reverse reconciliated coherent states quantum key distribution protocols with heterodyne detection. This bound is derived by maximizing the leaked information over the symplectic group of transformations that spans every physical Gaussian attack on individual pulses. We exhibit four different attacks that reach this bound, which shows that this bound is tight. Finally, we compare the secret key rate obtained with this new bound to the homodyne rate.
△ Less
Submitted 11 April, 2007;
originally announced April 2007.
-
Experimental implementation of non-Gaussian attacks on a continuous-variable quantum key distribution system
Authors:
Jerome Lodewyck,
Thierry Debuisschert,
Raul Garcia-Patron,
Rosa Tualle-Brouri,
Nicolas J. Cerf,
Philippe Grangier
Abstract:
An intercept-resend attack on a continuous-variable quantum-key-distribution protocol is investigated experimentally. By varying the interception fraction, one can implement a family of attacks where the eavesdropper totally controls the channel parameters. In general, such attacks add excess noise in the channel, and may also result in non-Gaussian output distributions. We implement and charact…
▽ More
An intercept-resend attack on a continuous-variable quantum-key-distribution protocol is investigated experimentally. By varying the interception fraction, one can implement a family of attacks where the eavesdropper totally controls the channel parameters. In general, such attacks add excess noise in the channel, and may also result in non-Gaussian output distributions. We implement and characterize the measurements needed to detect these attacks, and evaluate experimentally the information rates available to the legitimate users and the eavesdropper. The results are consistent with the optimality of Gaussian attacks resulting from the security proofs.
△ Less
Submitted 31 January, 2007;
originally announced January 2007.
-
Controlling excess noise in fiber optics continuous variables quantum key distribution
Authors:
Jérôme Lodewyck,
Thierry Debuisschert,
Rosa Tualle-Brouri,
Philippe Grangier
Abstract:
We describe a continuous variables coherent states quantum key distribution system working at 1550 nm, and entirely made of standard fiber optics and telecom components, such as integrated-optics modulators, couplers and fast InGaAs photodiodes. The setup is composed of an emitter randomly modulating a coherent state in the complex plane with a doubly Gaussian distribution, and a receiver based…
▽ More
We describe a continuous variables coherent states quantum key distribution system working at 1550 nm, and entirely made of standard fiber optics and telecom components, such as integrated-optics modulators, couplers and fast InGaAs photodiodes. The setup is composed of an emitter randomly modulating a coherent state in the complex plane with a doubly Gaussian distribution, and a receiver based on a shot noise limited time-resolved homodyne detector. By using a reverse reconciliation protocol, the device can transfer a raw key rate up to 1 Mb/s, with a proven security against Gaussian or non-Gaussian attacks. The dependence of the secret information rate of the present fiber set-up is studied as a function of the line transmission and excess noise.
△ Less
Submitted 1 December, 2005; v1 submitted 10 November, 2005;
originally announced November 2005.