-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data
Authors:
The DEAP Collaboration,
P. Adhikari,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
D. J. Auty,
M. Batygov,
B. Beltran,
C. E. Bina,
W. Bonivento,
M. G. Boulay,
J. F. Bueno,
B. Cai,
M. Cárdenas-Montes,
S. Choudhary,
B. T. Cleveland,
R. Crampton,
S. Daugherty,
P. DelGobbo,
P. Di Stefano,
G. Dolganov,
L. Doria,
F. A. Duncan,
M. Dunford,
E. Ellingwood
, et al. (73 additional authors not shown)
Abstract:
The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace…
▽ More
The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Long-term temporal stability of the DarkSide-50 dark matter detector
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time project…
▽ More
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.
△ Less
Submitted 22 May, 2024; v1 submitted 30 November, 2023;
originally announced November 2023.
-
Directionality of nuclear recoils in a liquid argon time projection chamber
Authors:
The DarkSide-20k Collaboration,
:,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
M. Ave,
I. Ch. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado-Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
V. Bocci,
W. M. Bonivento,
B. Bottino,
M. G. Boulay,
J. Busto,
M. Cadeddu
, et al. (243 additional authors not shown)
Abstract:
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scint…
▽ More
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence level
△ Less
Submitted 28 July, 2023;
originally announced July 2023.
-
Search for dark matter annual modulation with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range abo…
▽ More
Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above $40~{\rm eV_{ee}}$, the lowest threshold ever achieved in such a search.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Search for low mass dark matter in DarkSide-50: the bayesian network approach
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (119 additional authors not shown)
Abstract:
We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there…
▽ More
We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.
△ Less
Submitted 26 April, 2023; v1 submitted 3 February, 2023;
originally announced February 2023.
-
The ASIMOV Prize for scientific publishing -- HEP researchers trigger young people toward science
Authors:
Andrea Ventura,
Wanda Maria Alberico,
Roberta Antolini,
Silvia Arezzini,
Lorenzo Bellagamba,
Nicola Cavallo,
Claudia Cecchi,
Silvio Cherubini,
Roberta Colalillo,
Giuseppe Di Sciascio,
Carla Distefano,
Silvano Fuso,
Giuliana Galati,
Rebecca Hueting,
Sandra Leone,
Marcello Lissia,
Silvia Miozzi,
Daniele Mura,
Alessandro Papa,
Anna Parisi,
Giovanni Maria Piacentino,
Carlo Puggioni,
Marco Radici,
Sonia Sebastiani,
Antonio Sidoti
, et al. (6 additional authors not shown)
Abstract:
This work presents the ASIMOV Prize for scientific publishing, which was launched in Italy in 2016. The prize aims to bring the young generations closer to scientific culture, through the critical reading of popular science books. The books are selected by a committee that includes scientists, professors, Ph.D. and Ph.D. students, writers, journalists and friends of culture, and most importantly,…
▽ More
This work presents the ASIMOV Prize for scientific publishing, which was launched in Italy in 2016. The prize aims to bring the young generations closer to scientific culture, through the critical reading of popular science books. The books are selected by a committee that includes scientists, professors, Ph.D. and Ph.D. students, writers, journalists and friends of culture, and most importantly, over 800 school teachers. Students are actively involved in the prize, according to the best practices of public engagement: they read, review the books and vote for them, choosing the winner. The experience is quite successful: 12,000 students from 270 schools all over Italy participated in the last edition. The possibility of replicating this experience in other countries is indicated, as was done in Brazil in 2020 with more than encouraging results.
△ Less
Submitted 20 October, 2022;
originally announced October 2022.
-
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Authors:
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. Ch. Avetisov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
E. Berzin,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino
, et al. (274 additional authors not shown)
Abstract:
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These stu…
▽ More
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino floor for GeV-scale masses and significant sensitivity down to 10 MeV/c$^2$ considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector's sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.
△ Less
Submitted 20 June, 2023; v1 submitted 2 September, 2022;
originally announced September 2022.
-
Search for dark matter particle interactions with electron final states with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella
, et al. (120 additional authors not shown)
Abstract:
We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark pho…
▽ More
We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark photon kinetic mixing parameter $κ$. We also set the first dark matter direct-detection constraints on the mixing angle $\left|U_{e4}\right|^2$ for keV sterile neutrinos.
△ Less
Submitted 16 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Search for dark matter-nucleon interactions via Migdal effect with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using…
▽ More
Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12306 $\pm$ 184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c$^2$. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below $3.6$ GeV/c$^2$.
△ Less
Submitted 16 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Search for low-mass dark matter WIMPs with 12 ton-day exposure of DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella,
P. Cavalcante
, et al. (119 additional authors not shown)
Abstract:
We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately…
▽ More
We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately model the background rate and spectra down to 0.06 keV$_{er}$. A 90% C.L. exclusion limit for the spin-independent cross section of 3 GeV/c$^2$ mass WIMP on nucleons is set at 6$\times$10$^{-43}$ cm$^2$, about a factor 10 better than the previous DarkSide-50 limit. This analysis extends the exclusion region for spin-independent dark matter interactions below the current experimental constraints in the $[1.2, 3.6]$ GeV/c$^2$ WIMP mass range.
△ Less
Submitted 24 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
D. J. Auty,
H. Benmansour,
C. E. Bina,
W. Bonivento,
M. G. Boulay,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. Daugherty,
P. DelGobbo,
P. Di Stefano,
L. Doria,
M. Dunford,
E. Ellingwood,
A. Erlandson,
S. S. Farahani,
N. Fatemighomi,
G. Fiorillo
, et al. (72 additional authors not shown)
Abstract:
Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scat…
▽ More
Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.
△ Less
Submitted 5 January, 2022; v1 submitted 20 August, 2021;
originally announced August 2021.
-
Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
Authors:
The DarkSide collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella,
P. Cavalcante
, et al. (114 additional authors not shown)
Abstract:
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionizat…
▽ More
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to $\sim$180~eV$_{er}$, exploiting $^{37}$Ar and $^{39}$Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Moreover, we present a model-dependent determination of the ionization response to nuclear recoils down to $\sim$500~eV$_{nr}$, the lowest ever achieved in liquid argon, using \textit{in situ} neutron calibration sources and external datasets from neutron beam experiments.
△ Less
Submitted 15 September, 2021; v1 submitted 16 July, 2021;
originally announced July 2021.
-
A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella
, et al. (114 additional authors not shown)
Abstract:
Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nucleus down to the so-called neutrino floor, in a mass range from few GeV's to hundredths of TeV's. Based on the successful operation of the DarkSide-5…
▽ More
Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nucleus down to the so-called neutrino floor, in a mass range from few GeV's to hundredths of TeV's. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all kind of observed events, is essential for an optimal design of the new experiment. In this paper, we report on a particular set of events, which were not used for dark matter searches. Namely, standard two-pulse scintillation-ionization signals accompanied by a small amplitude third pulse, originating from single or few electrons, in a time window of less than a maximum drift time. We compare our findings to those of a recent paper of the LUX Collaboration (D.S.Akerib et al. Phys.Rev.D 102, 092004). Indeed, both experiments observe events related to photoionization of the cathode. From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths around 128 nm, in liquid argon. Also, both experiments observe events likely related to photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be one order of magnitude smaller in DarkSide-50 than in LUX. This result, together with the much larger measured electron lifetime, coherently hints toward a lower concentration of contaminants in DarkSide-50 than in LUX.
△ Less
Submitted 27 November, 2021; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Performance of the ReD TPC, a novel double-phase LAr detector with Silicon Photomultiplier Readout
Authors:
P. Agnes,
S. Albergo,
I. Albuquerque,
M. Arba,
M. Ave,
A. Boiano,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
A. Caminata,
N. Canci,
G. Cappello,
M. Caravati,
M. Cariello,
S. Castellano,
S. Catalanotti,
V. Cataudella,
R. Cereseto,
R. Cesarano,
C. Cicalò,
G. Covone,
A. de Candia,
G. De Filippis,
G. De Rosa
, et al. (42 additional authors not shown)
Abstract:
A double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of the ReD project is to investigate the directional sensitivity of argon-based TPCs via columnar recombination to nuclear recoils in the energy range of interest (20-200 keV$_{nr}$) for direct dark matter searches. The key nove…
▽ More
A double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of the ReD project is to investigate the directional sensitivity of argon-based TPCs via columnar recombination to nuclear recoils in the energy range of interest (20-200 keV$_{nr}$) for direct dark matter searches. The key novel feature of the ReD TPC is a readout system based on cryogenic Silicon Photomultipliers, which are employed and operated continuously for the first time in an argon TPC. Over the course of six months, the ReD TPC was commissioned and characterised under various operating conditions using $γ$-ray and neutron sources, demonstrating remarkable stability of the optical sensors and reproducibility of the results. The scintillation gain and ionisation amplification of the TPC were measured to be $g_1 = (0.194 \pm 0.013)$ PE/photon and $g_2 = (20.0 \pm 0.9)$ PE/electron, respectively. The ratio of the ionisation to scintillation signals (S2/S1), instrumental for the positive identification of a candidate directional signal induced by WIMPs, has been investigated for both nuclear and electron recoils. At a drift field of 183 V/cm, an S2/S1 dispersion of 12% was measured for nuclear recoils of approximately 60-90 keV$_{nr}$, as compared to 18% for electron recoils depositing 60 keV of energy. The detector performance reported here meets the requirements needed to achieve the principal scientific goals of the ReD experiment in the search for a directional effect due to columnar recombination. A phenomenological parameterisation of the recombination probability in LAr is presented and employed for modeling the dependence of scintillation quenching and charge yield on the drift field for electron recoils between 50-500 keV and fields up to 1000 V/cm.
△ Less
Submitted 24 June, 2021;
originally announced June 2021.
-
Il progetto Lab2Go per la diffusione della pratica laboratoriale nelle Scuole Secondarie di II grado
Authors:
Mirco Andreotti,
Pia Astone,
Donatella Campana,
Antonella Cartoni,
Fausto Casaburo,
Francesca Cavanna,
Gianluigi Cibinetto,
Antonella Dalla Cort,
Giulia De Bonis,
Marta Della Seta,
Francesca Di Mauro,
Giuseppe Di Sciascio,
Riccardo Faccini,
Federica Favino,
Luca Iocchi,
Marcello Lissia,
Giulia Morganti,
Mauro Mancini,
Giovanni Organtini,
Francesco Pennazio,
Francesco Piacentini,
Alina Piras,
Maria Ragosta,
Lorenzo Roberti,
Anna Rita Rossi
, et al. (2 additional authors not shown)
Abstract:
Even if laboratory practice is essential for all scientific branches of knowledge, it is often neglected at High School, due to lack of time and/or resources. To establish a closer contact between school and experimental sciences, the University Sapienza of Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project, with the goal of spreading laboratory practice among st…
▽ More
Even if laboratory practice is essential for all scientific branches of knowledge, it is often neglected at High School, due to lack of time and/or resources. To establish a closer contact between school and experimental sciences, the University Sapienza of Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project, with the goal of spreading laboratory practice among students and teachers in high schools.
△ Less
Submitted 20 November, 2021; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
D. J. Auty,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
J. M. Corning
, et al. (104 additional authors not shown)
Abstract:
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar…
▽ More
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors.
The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.
△ Less
Submitted 6 April, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Separating $^{39}$Ar from $^{40}$Ar by cryogenic distillation with Aria for dark matter searches
Authors:
DarkSide Collaboration,
P. Agnes,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
M. Arba,
P. Arpaia,
S. Arcelli,
M. Ave,
I. Ch. Avetissov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
A. Bondar,
W. M. Bonivento,
E. Borisova
, et al. (287 additional authors not shown)
Abstract:
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. Aria was designed to reduce the isotopi…
▽ More
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. Aria was designed to reduce the isotopic abundance of $^{39}$Ar, a $β$-emitter of cosmogenic origin, whose activity poses background and pile-up concerns in the detectors, in the argon used for the dark-matter searches, the so-called Underground Argon (UAr). In this paper, we discuss the requirements, design, construction, tests, and projected performance of the plant for the isotopic cryogenic distillation of argon. We also present the successful results of isotopic cryogenic distillation of nitrogen with a prototype plant, operating the column at total reflux.
△ Less
Submitted 23 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos
Authors:
P. Agnes,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
S. Arcelli,
M. Ave,
I. Ch. Avetissov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino,
M. G. Boulay,
G. Buccino
, et al. (251 additional authors not shown)
Abstract:
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and AR…
▽ More
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and ARGO, respectively.
Thanks to the low-energy threshold of $\sim$0.5~keV$_{nr}$ achievable by exploiting the ionization channel, DarkSide-20k and ARGO have the potential to discover supernova bursts throughout our galaxy and up to the Small Magellanic Cloud, respectively, assuming a 11-M$_{\odot}$ progenitor star. We report also on the sensitivity to the neutronization burst, whose electron neutrino flux is suppressed by oscillations when detected via charged current and elastic scattering. Finally, the accuracies in the reconstruction of the average and total neutrino energy in the different phases of the supernova burst, as well as its time profile, are also discussed, taking into account the expected background and the detector response.
△ Less
Submitted 31 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
Authors:
The DarkSide collaboration,
C. E. Aalseth,
S. Abdelhakim,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
V. Barbaryan,
A. Barrado Olmedo,
G. Batignani
, et al. (290 additional authors not shown)
Abstract:
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the…
▽ More
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
△ Less
Submitted 26 February, 2021; v1 submitted 4 April, 2020;
originally announced April 2020.
-
Effective field theory interactions for liquid argon target in DarkSide-50 experiment
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli
, et al. (143 additional authors not shown)
Abstract:
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper…
▽ More
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between $2.4 \times 10^{-45} \, \mathrm{cm}^2$ and $2.3 \times 10^{-42} \, \mathrm{cm}^2$ (8.9 $\times 10^{-45} \, \mathrm{cm}^2$ and 6.0 $\times 10^{-42} \, \mathrm{cm}^2$) for WIMPs of mass of 100 $\mathrm{GeV/c^2}$ (1000 $\mathrm{GeV/c^2}$) at 90\% confidence level.
△ Less
Submitted 18 February, 2020;
originally announced February 2020.
-
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
Authors:
The DarkSide Collaboration,
C. E. Aalseth,
S. Abdelhakim,
F. Acerbi,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
A. Barrado Olmedo,
G. Batignani
, et al. (306 additional authors not shown)
Abstract:
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa…
▽ More
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
Measurement of the ion fraction and mobility of $^{218}$Po produced in $^{222}$Rn decays in liquid argon
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella
, et al. (141 additional authors not shown)
Abstract:
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)…
▽ More
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)$\times$10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
△ Less
Submitted 28 October, 2019; v1 submitted 22 July, 2019;
originally announced July 2019.
-
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (150 additional authors not shown)
Abstract:
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark ma…
▽ More
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark matter-nucleon spin-independent cross section of 1.14E-44 cm^2 (3.78E-44 cm^2, 3.43E-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10 TeV/c^2).
△ Less
Submitted 19 November, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati
, et al. (171 additional authors not shown)
Abstract:
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
△ Less
Submitted 3 October, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati
, et al. (170 additional authors not shown)
Abstract:
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detecto…
▽ More
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.
△ Less
Submitted 28 August, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
M. P. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (141 additional authors not shown)
Abstract:
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs…
▽ More
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.
△ Less
Submitted 23 July, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter
Authors:
DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela
, et al. (155 additional authors not shown)
Abstract:
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which proce…
▽ More
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.
△ Less
Submitted 20 November, 2017; v1 submitted 31 July, 2017;
originally announced July 2017.
-
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
M. Ave,
H. O. Back,
A. I. Barrado Olmedo,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino
, et al. (260 additional authors not shown)
Abstract:
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a…
▽ More
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $ν$-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ. This will give sensitivity to WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background. DarkSide-20k could then extend its operation to a decade, increasing the exposure to 200 t yr, reaching a sensitivity of $7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass.
△ Less
Submitted 25 July, 2017;
originally announced July 2017.
-
Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
S. Catalanotti,
V. Cataudella
, et al. (125 additional authors not shown)
Abstract:
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination techni…
▽ More
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination technique, and the measurement of the residual 39Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.
△ Less
Submitted 26 September, 2017; v1 submitted 18 July, 2017;
originally announced July 2017.
-
Cryogenic Characterization of FBK RGB-HD SiPMs
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Ampudia,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
H. O. Back,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
R. Bunker
, et al. (246 additional authors not shown)
Abstract:
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio…
▽ More
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisition system and analysis software were used to precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300 K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a few Hz/mm$^2$.
△ Less
Submitted 12 September, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.
-
Directional dark matter detection sensitivity of a two-phase liquid argon detector
Authors:
M. Cadeddu,
M. Lissia,
P. Agnes,
G. Batignani,
W. M. Bonivento,
B. Bottino,
M. Caravati,
A. Cocco,
G. Covone,
A. de Candia,
S. Catalanotti,
V. Cataudella,
C. Cicalo',
G. De Filippis,
G. De Rosa,
S. Davini,
A. Devoto,
C. Dionisi,
D. Franco,
C. Giganti,
C. Galbiati,
S. Giagu,
M. Gulino,
M. Kuss,
L. Lista
, et al. (16 additional authors not shown)
Abstract:
We examine the sensitivity of a large scale two-phase liquid argon detector to the directionality of the dark matter signal. This study was performed under the assumption that, above 50 keV of recoil energy, one can determine (with some resolution) the direction of the recoil nucleus without head-tail discrimination, as suggested by past studies that proposed to exploit the dependence of columnar…
▽ More
We examine the sensitivity of a large scale two-phase liquid argon detector to the directionality of the dark matter signal. This study was performed under the assumption that, above 50 keV of recoil energy, one can determine (with some resolution) the direction of the recoil nucleus without head-tail discrimination, as suggested by past studies that proposed to exploit the dependence of columnar recombination on the angle between the recoil nucleus direction and the electric field. In this paper we study the differential interaction recoil rate as a function of the recoil direction angle with respect to the zenith for a detector located at the Laboratori Nazionali del Gran Sasso and we determine its diurnal and seasonal modulation. Using a likelihood-ratio based approach we show that, with the angular information alone, 100 events are enough to reject the isotropic hypothesis at three standard deviation level. For an exposure of 100 tonne years this would correspond to a spin independent WIMP-nucleon cross section of about 10^-46 cm^2 at 200 GeV WIMP mass. The results presented in this paper provide strong motivation for the experimental determination of directional recoil effects in two-phase liquid argon detectors.
△ Less
Submitted 14 January, 2019; v1 submitted 11 April, 2017;
originally announced April 2017.
-
CALIS - a CALibration Insertion System for the DarkSide-50 dark matter search experiment
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (140 additional authors not shown)
Abstract:
This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liqui…
▽ More
This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.
△ Less
Submitted 27 September, 2017; v1 submitted 8 November, 2016;
originally announced November 2016.
-
Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini
, et al. (136 additional authors not shown)
Abstract:
Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.
Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.
△ Less
Submitted 4 November, 2016; v1 submitted 1 November, 2016;
originally announced November 2016.
-
The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors
Authors:
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
M. Carlini,
S. Catalanotti
, et al. (133 additional authors not shown)
Abstract:
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detec…
▽ More
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors.
△ Less
Submitted 10 June, 2016;
originally announced June 2016.
-
The veto system of the DarkSide-50 experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector…
▽ More
Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.
△ Less
Submitted 24 December, 2015;
originally announced December 2015.
-
Results from the first use of low radioactivity argon in a dark matter search
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the La…
▽ More
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
△ Less
Submitted 13 April, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
The role of correlation entropy in nuclear fusion in liquid lithium, indium and mercury
Authors:
M. Coraddu,
M. Lissia,
P. Quarati,
A. M. Scarfone
Abstract:
Nuclear fusion cross-sections considerably higher than corresponding theoretical predictions are observed in low-energy experiments with metal matrix targets and accelerated deuteron beams. The cross-section increment is significantly higher for liquid than for solid targets. We propose that the same two-body correlation entropy used in evaluating the metal melting entropy explains the large liqui…
▽ More
Nuclear fusion cross-sections considerably higher than corresponding theoretical predictions are observed in low-energy experiments with metal matrix targets and accelerated deuteron beams. The cross-section increment is significantly higher for liquid than for solid targets. We propose that the same two-body correlation entropy used in evaluating the metal melting entropy explains the large liquid-solid difference of the effective screening potential that parameterizes the cross-section increment. This approach is applied to the specific case of the $^6$Li(d,$α$)$^4$He reaction, whose measured screening potential liquid-solid difference is $(235 \pm 63)$ eV. Cross sections in the two metals with the highest two-body correlation entropy (In and Hg) have not yet been measured: increments of the cross sections in liquid relative to the ones in solid metals are estimated with the same procedure.
△ Less
Submitted 19 January, 2015;
originally announced January 2015.
-
The Phase Space Elementary Cell in Classical and Generalized Statistics
Authors:
Piero Quarati,
Marcello Lissia
Abstract:
In the past, the phase-space elementary cell of a non-quantized system was set equal to the third power of the Planck constant; in fact, it is not a necessary assumption. We discuss how the phase space volume, the number of states and the elementary-cell volume of a system of non-interacting N particles, changes when an interaction is switched on and the system becomes or evolves to a system of co…
▽ More
In the past, the phase-space elementary cell of a non-quantized system was set equal to the third power of the Planck constant; in fact, it is not a necessary assumption. We discuss how the phase space volume, the number of states and the elementary-cell volume of a system of non-interacting N particles, changes when an interaction is switched on and the system becomes or evolves to a system of correlated non-Boltzmann particles and derives the appropriate expressions. Even if we assume that nowadays the volume of the elementary cell is equal to the cube of the Planck constant, h^3, at least for quantum systems, we show that there is a correspondence between different values of h in the past, with important and, in principle, measurable cosmological and astrophysical consequences, and systems with an effective smaller (or even larger) phase-space volume described by non-extensive generalized statistics.
△ Less
Submitted 19 January, 2015;
originally announced January 2015.
-
Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS
Authors:
Borexino Collaboration,
G. Bellini,
J. Benziger,
D. Bick,
G. Bonfini,
D. Bravo,
M. Buizza Avanzini,
B. Caccianiga,
L. Cadonati,
F. Calaprice,
C. Carraro,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
V. Chubakov,
D. D'Angelo,
S. Davini,
A. Derbin,
A. Etenko,
K. Fomenko,
D. Franco,
C. Galbiati,
S. Gazzana,
C. Ghiano,
M. Giammarchi
, et al. (70 additional authors not shown)
Abstract:
We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00…
▽ More
We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) μs and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties and are compatible with previous measurements.
△ Less
Submitted 5 July, 2013; v1 submitted 6 December, 2012;
originally announced December 2012.
-
Nuclear physics for geo-neutrino studies
Authors:
Gianni Fiorentini,
Aldo Ianni,
George Korga,
Marcello Lissia,
Fabio Mantovani,
Lino Miramonti,
Lothar Oberauer,
Michel Obolensky,
Oleg Smirnov,
Yury Suvorov
Abstract:
Geo-neutrino studies are based on theoretical estimates of geo-neutrino spectra. We propose a method for a direct measurement of the energy distribution of antineutrinos from decays of long-lived radioactive isotopes. We present preliminary results for the geo-neutrinos from Bi-214 decay, a process which accounts for about one half of the total geo-neutrino signal. The feeding probability of the…
▽ More
Geo-neutrino studies are based on theoretical estimates of geo-neutrino spectra. We propose a method for a direct measurement of the energy distribution of antineutrinos from decays of long-lived radioactive isotopes. We present preliminary results for the geo-neutrinos from Bi-214 decay, a process which accounts for about one half of the total geo-neutrino signal. The feeding probability of the lowest state of Bi-214 - the most important for geo-neutrino signal - is found to be p_0 = 0.177 \pm 0.004 (stat) ^{+0.003}_{-0.001} (sys), under the hypothesis of Universal Neutrino Spectrum Shape (UNSS). This value is consistent with the (indirect) estimate of the Table of Isotopes (ToI). We show that achievable larger statistics and reduction of systematics should allow to test possible distortions of the neutrino spectrum from that predicted using the UNSS hypothesis. Implications on the geo-neutrino signal are discussed.
△ Less
Submitted 24 August, 2009;
originally announced August 2009.
-
Nuclear problems in astrophysical q-plasmas and environments
Authors:
M. Coraddu,
M. Lissia,
P. Quarati,
A. M. Scarfone
Abstract:
Experimental measurements in terrestrial laboratory, space and astrophysical observations of variation and fluctuation of nuclear decay constants, measurements of large enhancements in fusion reaction rate of deuterons implanted in metals and electron capture by nuclei in solar core indicate that these processes depend on the environment where take place and possibly also on the fluctuation of s…
▽ More
Experimental measurements in terrestrial laboratory, space and astrophysical observations of variation and fluctuation of nuclear decay constants, measurements of large enhancements in fusion reaction rate of deuterons implanted in metals and electron capture by nuclei in solar core indicate that these processes depend on the environment where take place and possibly also on the fluctuation of some extensive parameters and eventually on stellar energy production. Electron screening is the first important environment effect. We need to develop a treatment beyond the Debye-Huckel screening approach, commonly adopted within global thermodynamic equilibrium. Advances in the description of these processes can be obtained by means of q-thermostatistics and/or superstatistics for metastable states. This implies to handle without ambiguities the case q<1.
△ Less
Submitted 18 June, 2009;
originally announced June 2009.
-
Anomalous enhancements of low-energy fusion rates in plasmas: the role of ion momentum distributions and inhomogeneous screening
Authors:
M. Coraddu,
M. Lissia,
P. Quarati
Abstract:
Non-resonant fusion cross-sections significantly higher than corresponding theoretical predictions are observed in low-energy experiments with deuterated matrix target. Models based on thermal effects, electron screening, or quantum-effect dispersion relations have been proposed to explain these anomalous results: none of them appears to satisfactory reproduce the experiments. Velocity distribut…
▽ More
Non-resonant fusion cross-sections significantly higher than corresponding theoretical predictions are observed in low-energy experiments with deuterated matrix target. Models based on thermal effects, electron screening, or quantum-effect dispersion relations have been proposed to explain these anomalous results: none of them appears to satisfactory reproduce the experiments. Velocity distributions are fundamental for the reaction rates and deviations from the Maxwellian limit could play a central role in explaining the enhancement. We examine two effects: an increase of the tail of the target Deuteron momentum distribution due to the Galitskii-Yakimets quantum uncertainty effect, which broadens the energy-momentum relation; and spatial fluctuations of the Debye-Hückel radius leading to an effective increase of electron screening. Either effect leads to larger reaction rates especially large at energies below a few keV, reducing the discrepancy between observations and theoretical expectations.
△ Less
Submitted 11 May, 2009;
originally announced May 2009.
-
Analytical predictions of non-Gaussian distribution parameters for stellar plasmas
Authors:
A. M. Scarfone,
P. Quarati,
G. Mezzorani,
M. Lissia
Abstract:
Stimulated by the recent debate on the physical relevance and on the predictivity of q-Gaussian formalism, we present specific analytical expressions for the parameters characterizing non-Gaussian distributions, such as the nonextensive parameter q, expressions that we have proposed for different physical systems, an important example being plasmas in the stellar cores.
Stimulated by the recent debate on the physical relevance and on the predictivity of q-Gaussian formalism, we present specific analytical expressions for the parameters characterizing non-Gaussian distributions, such as the nonextensive parameter q, expressions that we have proposed for different physical systems, an important example being plasmas in the stellar cores.
△ Less
Submitted 16 June, 2008; v1 submitted 11 June, 2008;
originally announced June 2008.
-
Nuclear physics inputs needed for geo-neutrino studies
Authors:
G. Bellini,
G. Fiorentini,
A. Ianni,
M. Lissia,
F. Mantovani,
O. Smirnov
Abstract:
Geo-neutrino studies are based on theoretical estimates of geo-neutrino spectra. We propose a method for a direct measurement of the energy distribution of antineutrinos from decays of long-lived radioactive isotopes.
Geo-neutrino studies are based on theoretical estimates of geo-neutrino spectra. We propose a method for a direct measurement of the energy distribution of antineutrinos from decays of long-lived radioactive isotopes.
△ Less
Submitted 3 December, 2007;
originally announced December 2007.
-
Geo-neutrinos and Earth's interior
Authors:
Gianni Fiorentini,
Marcello Lissia,
Fabio Mantovani
Abstract:
The deepest hole that has ever been dug is about 12 km deep. Geochemists analyze samples from the Earth's crust and from the top of the mantle. Seismology can reconstruct the density profile throughout all Earth, but not its composition. In this respect, our planet is mainly unexplored. Geo-neutrinos, the antineutrinos from the progenies of U, Th and K40 decays in the Earth, bring to the surface…
▽ More
The deepest hole that has ever been dug is about 12 km deep. Geochemists analyze samples from the Earth's crust and from the top of the mantle. Seismology can reconstruct the density profile throughout all Earth, but not its composition. In this respect, our planet is mainly unexplored. Geo-neutrinos, the antineutrinos from the progenies of U, Th and K40 decays in the Earth, bring to the surface information from the whole planet, concerning its content of natural radioactive elements. Their detection can shed light on the sources of the terrestrial heat flow, on the present composition, and on the origins of the Earth. Geo-neutrinos represent a new probe of our planet, which can be exploited as a consequence of two fundamental advances that occurred in the last few years: the development of extremely low background neutrino detectors and the progress on understanding neutrino propagation. We review the status and the prospects of the field.
△ Less
Submitted 18 August, 2007; v1 submitted 23 July, 2007;
originally announced July 2007.
-
Fusion reactions in plasmas as probe of the high-momentum tail of particle distributions
Authors:
Massimo Coraddu,
Marcello Lissia,
Giuseppe Mezzorani,
Piero Quarati
Abstract:
In fusion reactions, the Coulomb barrier selects particles from the high-momentum part of the distribution. Therefore, small variations of the high-momentum tail of the velocity distribution can produce strong effects on fusion rates. In plasmas several potential mechanisms exist that can produce deviations from the standard Maxwell-Boltzmann distribution. Quantum broadening of the energy-moment…
▽ More
In fusion reactions, the Coulomb barrier selects particles from the high-momentum part of the distribution. Therefore, small variations of the high-momentum tail of the velocity distribution can produce strong effects on fusion rates. In plasmas several potential mechanisms exist that can produce deviations from the standard Maxwell-Boltzmann distribution. Quantum broadening of the energy-momentum dispersion relation of the plasma quasi-particles modifies the high-momentum tail and could explain the fusion-rate enhancement observed in low-energy nuclear reaction experiments.
△ Less
Submitted 16 December, 2005;
originally announced December 2005.
-
Statistical descriptions of nonlinear systems at the onset of chaos
Authors:
Massmimo Coraddu,
Marcello Lissia,
Roberto Tonelli
Abstract:
Ensemble of initial conditions for nonlinear maps can be described in terms of entropy. This ensemble entropy shows an asymptotic linear growth with rate K. The rate K matches the logarithm of the corresponding asymptotic sensitivity to initial conditions λ. The statistical formalism and the equality K=λcan be extended to weakly chaotic systems by suitable and corresponding generalizations of th…
▽ More
Ensemble of initial conditions for nonlinear maps can be described in terms of entropy. This ensemble entropy shows an asymptotic linear growth with rate K. The rate K matches the logarithm of the corresponding asymptotic sensitivity to initial conditions λ. The statistical formalism and the equality K=λcan be extended to weakly chaotic systems by suitable and corresponding generalizations of the logarithm and of the entropy. Using the logistic map as a test case we consider a wide class of deformed statistical description which includes Tsallis, Abe and Kaniadakis proposals. The physical criterion of finite-entropy growth K strongly restricts the suitable entropies. We study how large is the region in parameter space where the generalized description is useful.
△ Less
Submitted 30 November, 2005;
originally announced November 2005.