-
Analysis of photoinjector transverse phase space in action and phase coordinates
Authors:
Houjun Qian,
Mikhail Krasilnikov,
Zakaria Aboulbanine,
Gowri Adhikari,
Namra Aftab,
Prach Boonpornpras,
Georgi Georgiev,
James Good,
Matthias Gross,
Christian Koschitzki,
Xiangkun Li,
Osip Lishilin,
Anusorn Lueangaramwong,
Raffael Niemczyk,
Anne Oppelt,
Guan Shu,
Frank Stephan,
Grygorii Vashchenko,
Tobias Weilbach
Abstract:
Photoinjectors are the main high brightness electron sources for X-ray free electron lasers (XFEL). Photoinjector emittance reduction is one of the key knobs for improving XFEL lasing, so precise emittance measurement is critical. It's well known that rms emittance is very sensitive to low intensity tails of particle distributions in the phase space, whose measurement depend on the signal to noise…
▽ More
Photoinjectors are the main high brightness electron sources for X-ray free electron lasers (XFEL). Photoinjector emittance reduction is one of the key knobs for improving XFEL lasing, so precise emittance measurement is critical. It's well known that rms emittance is very sensitive to low intensity tails of particle distributions in the phase space, whose measurement depend on the signal to noise ratio (SNR) and image processing procedures. Such sensitivities make the interpretations of beam transverse brightness challenging, leading to different emittance definitions to reduce the impact of tail particles. In this paper, transverse phase space is analyzed in action and phase coordinates for both analytical models and experiments, which give a more intuitive way to calculate the beam core brightness.
△ Less
Submitted 18 February, 2022;
originally announced February 2022.
-
Slice energy spread measurement in the low energy photoinjector
Authors:
Houjun Qian,
Mikhail Krasilnikov,
Anusorn Lueangaramwong,
Xiangkun Li,
Osip Lishilin,
Zakaria Aboulbanine,
Gowri Adhikari,
Namra Aftab,
Prach Boonpornprasert,
Georgi Georgiev,
James Good,
Matthias Gross,
Christian Koschitzki,
Raffael Niemczyk,
Anne Oppelt,
Guan Shu,
Frank Stephan,
Grygorii Vashchenko,
Tobias Weilbach
Abstract:
Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy ($>$100 MeV) photoinjectors at SwissFEL and European XFEL have reported much higher slice energy spread than expected at their XFEL working points (200 - 250 pC). In this paper, a new method for measuring slice energy spread…
▽ More
Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy ($>$100 MeV) photoinjectors at SwissFEL and European XFEL have reported much higher slice energy spread than expected at their XFEL working points (200 - 250 pC). In this paper, a new method for measuring slice energy spread at a lower beam energy ($\sim$20 MeV) is proposed and demonstrated at the PhotoInjector Test facility at DESY Zeuthen (PITZ), and the results for 250 pC and 500 pC are much lower than those measured at high energy injectors.
△ Less
Submitted 31 January, 2022;
originally announced January 2022.
-
Single shot cathode transverse momentum imaging in high brightness photoinjectors
Authors:
Peng-Wei Huang,
Houjun Qian,
Ye Chen,
Daniele Filippetto,
Matthias Gross,
Igor Isaev,
Christian Koschitzki,
Mikhail Krasilnikov,
Shankar Lal,
Xiangkun Li,
Osip Lishilin,
David Melkumyan,
Raffael Niemczyk,
Anne Oppelt,
Fernando Sannibale,
Hamed Shaker,
Guan Shu,
Frank Stephan,
Chuanxiang Tang,
Grygorii Vashchenko,
Weishi Wan
Abstract:
In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the li…
▽ More
In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode RF guns. By tuning the gun solenoid focusing, the electrons transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons transverse momenta. Both simulations and proof of principle experiments are reported.
△ Less
Submitted 17 February, 2020;
originally announced February 2020.
-
Passive Ballistic Microbunching of Non-Ultrarelativistic Electron Bunches using Electromagnetic Wakefields in Dielectric-Lined Waveguides
Authors:
Francois Lemery,
Philippe Piot,
Gayane Amatuni,
Prach Boonpornprasert,
Ye Lining Chen,
James David Good,
Bagrat Grigoryan,
Matthias Gross,
Mikhail Krasilnikov,
Osip Lishilin,
Gregor Loisch,
Anne Oppelt,
Sebastian Philipp,
Houjun Qian,
Yves Renier,
Frank Stephan,
Igor Zagorodnov
Abstract:
Temporally-modulated electron beams have a wide array of applications ranging from the generation of coherently-enhanced electromagnetic radiation to the resonant excitation of electromagnetic wakefields in advanced-accelerator concepts. Likewise producing low-energy ultrashort microbunches could be useful for ultra-fast electron diffraction and new accelerator-based light-source concepts. In this…
▽ More
Temporally-modulated electron beams have a wide array of applications ranging from the generation of coherently-enhanced electromagnetic radiation to the resonant excitation of electromagnetic wakefields in advanced-accelerator concepts. Likewise producing low-energy ultrashort microbunches could be useful for ultra-fast electron diffraction and new accelerator-based light-source concepts. In this Letter we propose and experimentally demonstrate a passive microbunching technique capable of forming a picosecond bunch train at $\sim 6$~MeV. The method relies on the excitation of electromagnetic wakefields as the beam propagates through a dielectric-lined waveguide. Owing to the non-ultrarelativistic nature of the beam, the induced energy modulation eventually converts into a density modulation as the beam travels in a following free-space drift. The modulated beam is further accelerated to $\sim20$~MeV while preserving the imparted density modulation.
△ Less
Submitted 25 June, 2018;
originally announced June 2018.
-
Compact ring-based X-ray source with on-orbit and on-energy laser-plasma injection
Authors:
Marlene Turner,
Jeremy Cheatam,
Auralee Edelen,
James Gerity,
Andrew Lajoie,
Gerard Lawler,
Osip Lishilin,
Kook** Moon,
Aakash Ajit Sahai,
Andrei Seryi,
Kai Shih,
Brandon Zerbe
Abstract:
We report here the results of a one week long investigation into the conceptual design of an X-ray source based on a compact ring with on-orbit and on-energy laser-plasma accelerator. We performed these studies during the June 2016 USPAS class "Physics of Accelerators, Lasers, and Plasma..." applying the art of inventiveness TRIZ. We describe three versions of the light source with the constraints…
▽ More
We report here the results of a one week long investigation into the conceptual design of an X-ray source based on a compact ring with on-orbit and on-energy laser-plasma accelerator. We performed these studies during the June 2016 USPAS class "Physics of Accelerators, Lasers, and Plasma..." applying the art of inventiveness TRIZ. We describe three versions of the light source with the constraints of the electron beam with energy $1\,\rm{GeV}$ or $3\,\rm{GeV}$ and a magnetic lattice design being normal conducting (only for the $1\,\rm{GeV}$ beam) or superconducting (for either beam). The electron beam recirculates in the ring, to increase the effective photon flux. We describe the design choices, present relevant parameters, and describe insights into such machines.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
Studies on charge production from Cs2Te photocathodes in the PITZ L-band normal conducting radio frequency photo injector
Authors:
C. Hernandez-Garcia,
M. Kraslinikov,
G. Asova,
M. Bakr,
P. Boonpornprasert,
J. Good,
M. Gross,
H. Huck,
I. Isaev,
D. Kalantaryan,
M. Khojoyan,
G. Kourkafas,
O. Lishilin,
D. Malyutin,
D. Melkumyan,
A. Oppelt,
M. Otevrel,
G. Pathak,
Y. Renier,
T. Rublack,
F. Stephan,
G. Vashchenko,
Q. Zhao
Abstract:
This paper discusses the behavior of electron bunch charge produced in an L-band normal conducting radio frequency cavity (RF gun) from Cs2Te photocathodes illuminated with ps-long UV laser pulses when the laser transverse distribution consists of a flat-top core with Gaussian-like decaying halo. The produced charge shows a linear dependence at low laser pulse energies as expected in the quantum e…
▽ More
This paper discusses the behavior of electron bunch charge produced in an L-band normal conducting radio frequency cavity (RF gun) from Cs2Te photocathodes illuminated with ps-long UV laser pulses when the laser transverse distribution consists of a flat-top core with Gaussian-like decaying halo. The produced charge shows a linear dependence at low laser pulse energies as expected in the quantum efficiency limited emission regime, while its dependence on laser pulse energy is observed to be much weaker for higher values, due to space charge limited emission. However, direct plug-in of experimental parameters into the space charge tracking code ASTRA yields lower output charge in the space charge limited regime compared to measured values. The rate of increase of the produced charge at high laser pulse energies close to the space charge limited emission regime seems to be proportional to the amount of halo present in the radial laser profile since the charge from the core has saturated already. By utilizing core + halo particle distributions based on measured radial laser profiles, ASTRA simulations and semi-analytical emission models reproduce the behavior of the measured charge for a wide range of RF gun and laser operational parameters within the measurement uncertainties.
△ Less
Submitted 1 July, 2016;
originally announced July 2016.