-
Result of the MICROSCOPE Weak Equivalence Principle test
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Joel Bergé,
Alain Robert,
Quentin Baghi,
Yves André,
Judicaël Bedouet,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Louis Demange,
Hansjoerg Dittus,
Océane Dhuicque,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh
, et al. (22 additional authors not shown)
Abstract:
The space mission MICROSCOPE dedicated to the test of the Equivalence Principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations ($a_{\rm A}$ and $a_{\rm B}$) of two test masses in terms of the Eötvös parameter $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$. No EP violation…
▽ More
The space mission MICROSCOPE dedicated to the test of the Equivalence Principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations ($a_{\rm A}$ and $a_{\rm B}$) of two test masses in terms of the Eötvös parameter $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$. No EP violation has been detected for two test masses, made from platinum and titanium alloys, in a sequence of 19 segments lasting from 13 to 198 hours down to the limit of the statistical error which is smaller than $10^{-14}$ for $ η({\rm{Ti, Pt}})$. Accumulating data from all segments leads to $η({\rm{Ti, Pt}}) =[-1.5\pm{}2.3{\rm (stat)}\pm{}1.5{\rm (syst)}] \times{}10^{-15}$ showing no EP violation at the level of $2.7\times{}10^{-15}$ if we combine stochastic and systematic errors quadratically. This represents an improvement of almost two orders of magnitude with respect to the previous best such test performed by the Eöt-Wash group. The reliability of this limit has been verified by comparing the free falls of two test masses of the same composition (platinum) leading to a null Eötvös parameter with a statistical uncertainty of $1.1\times{}10^{-15}$.
△ Less
Submitted 30 September, 2022;
originally announced September 2022.
-
MICROSCOPE mission: final results of the test of the Equivalence Principle
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Joel Bergé,
Alain Robert,
Quentin Baghi,
Yves André,
Judicaël Bedouet,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Louis Demange,
Hansjoerg Dittus,
Océane Dhuicque,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh
, et al. (22 additional authors not shown)
Abstract:
The MICROSCOPE mission was designed to test the Weak Equivalence Principle (WEP), stating the equality between the inertial and the gravitational masses, with a precision of $10^{-15}$ in terms of the Eötvös ratio $η$. Its experimental test consisted of comparing the accelerations undergone by two collocated test masses of different compositions as they orbited the Earth, by measuring the electros…
▽ More
The MICROSCOPE mission was designed to test the Weak Equivalence Principle (WEP), stating the equality between the inertial and the gravitational masses, with a precision of $10^{-15}$ in terms of the Eötvös ratio $η$. Its experimental test consisted of comparing the accelerations undergone by two collocated test masses of different compositions as they orbited the Earth, by measuring the electrostatic forces required to keep them in equilibrium. This was done with ultra-sensitive differential electrostatic accelerometers onboard a drag-free satellite. The mission lasted two and a half years, cumulating five-months-worth of science free-fall data, two thirds with a pair of test masses of different compositions -- Titanium and Platinum alloys -- and the last third with a reference pair of test masses of the same composition -- Platinum. We summarize the data analysis, with an emphasis on the characterization of the systematic uncertainties due to thermal instabilities and on the correction of short-lived events which could mimic a WEP violation signal. We found no violation of the WEP, with the Eötvös parameter of the Titanium and Platinum pair constrained to $η({\rm Ti, Pt})~=~ [-1.5 \pm 2.3~{\rm (stat)} \pm 1.5~{\rm (syst)}]~\times 10^{-15}$ at $1σ$ in statistical errors.
△ Less
Submitted 30 September, 2022;
originally announced September 2022.
-
MICROSCOPE: systematic errors
Authors:
Manuel Rodrigues,
Pierre Touboul1,
Gilles Metris,
Alain Robert,
Oceane Dhuicque,
Joel Berge,
Yves Andre,
Damien Boulanger,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Pascale Danto,
Bernard Foulon,
Pierre-Yves Guidotti,
Emilie Hardy,
Phuong-Anh Huynh,
Vincent Lebat,
Francoise Liorzou,
Benjamin Pouilloux,
Pascal Prieur,
Serge Reynaud,
Patrizia Torresi
Abstract:
The MICROSCOPE mission aims to test the Weak Equivalence Principle (WEP) in orbit with an unprecedented precision of 10$^{-15}$ on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Syste…
▽ More
The MICROSCOPE mission aims to test the Weak Equivalence Principle (WEP) in orbit with an unprecedented precision of 10$^{-15}$ on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Systematic error sources can be divided into three categories: external perturbations, such as the residual atmospheric drag or the gravity gradient at the satellite altitude, perturbations linked to the satellite design, such as thermal or magnetic perturbations, and perturbations from the instrument internal sources. Each systematic error is evaluated or bounded in order to set a reliable upper bound on the WEP parameter estimation uncertainty.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
MICROSCOPE instrument in-flight characterization
Authors:
Ratana Chhun,
Emilie Hardy,
Manuel Rodrigues,
Pierre Touboul,
Gilles Métris,
Damien Boulanger,
Bruno Christophe,
Pascale Danto,
Bernard Foulon,
Pierre-Yves Guidotti,
Phuong-Anh Huynh,
Vincent Lebat,
Françoise Liorzou,
Alain Robert
Abstract:
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subseq…
▽ More
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
△ Less
Submitted 12 May, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
MICROSCOPE instrument description and validation
Authors:
Françoise Liorzou,
Pierre Touboul,
Manuel Rodrigues,
Gilles Métris,
Yves André,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Ratana Chhun,
Bruno Christophe,
Pascale Danto,
Bernard Foulon,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh,
Claus Lämmerzahl,
Vincent Lebat,
Meike List,
Frank Löffler,
Benny Rievers,
Alain Robert,
Hanns Selig
Abstract:
Dedicated accelerometers have been developed for the MICROSCOPE mission taking into account the specific range of acceleration to be measured on board the satellite. Considering one micro-g and even less as the full range of the instrument, leads to a customized concept and a high performance electronics for the sensing and servo-actuations of the accelerometer test-masses. In addition to a very a…
▽ More
Dedicated accelerometers have been developed for the MICROSCOPE mission taking into account the specific range of acceleration to be measured on board the satellite. Considering one micro-g and even less as the full range of the instrument, leads to a customized concept and a high performance electronics for the sensing and servo-actuations of the accelerometer test-masses. In addition to a very accurate geometrical sensor core, a high performance electronics architecture provides the measurement of the weak electrostatic forces and torques applied to the test-masses. A set of capacitive sensors delivers the position and the attitude of the test-mass with respect to a very steady gold coated cage made in silica. The voltages applied on the electrodes surrounding each test-mass are finely controlled to generate the adequate electrical field and so the electrostatic pressures on the test-mass. This field maintains the test-mass motionless with respect to the instrument structure. Digital control laws are implemented in order to enable instrument operation flexibility and a weak position sensor noise. These electronics provide both the scientific data for MICROSCOPE's test of General Relativity and the data for the satellite drag-free and attitude control system (DFACS).
△ Less
Submitted 21 December, 2020;
originally announced December 2020.
-
MICROSCOPE Satellite and its Drag-Free and Attitude Control System
Authors:
Alain Robert,
Valerio Cipolla,
Pascal Prieur,
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Joel Bergé,
Damien Boulanger,
Ratana Chhun,
Bruno Christophe,
Pierre-Yves Guidotti,
Emilie Hardy,
Vincent Lebat,
Thomas Lienart,
Françoise Liorzou,
Benjamin Pouilloux
Abstract:
This paper focus on the description of the design and performance of the MICROSCOPE satellite and its Drag-Free and Attitude Control System (DFACS). The satellite is derived from CNES' Myriade platform family, albeit with significant upgrades dictated by the unprecedented MICROSCOPE's mission requirements. The 300kg drag-free microsatellite has completed its 2-year flight with higher-than-expected…
▽ More
This paper focus on the description of the design and performance of the MICROSCOPE satellite and its Drag-Free and Attitude Control System (DFACS). The satellite is derived from CNES' Myriade platform family, albeit with significant upgrades dictated by the unprecedented MICROSCOPE's mission requirements. The 300kg drag-free microsatellite has completed its 2-year flight with higher-than-expected performances. Its passive thermal concept allowed for variations smaller than 1 $μ$K at the measurement frequency $f_{\rm{EP}}$. The propulsion system provided a 6 axis continuous and very low noise thrust from zero to some hundreds of micronewtons. Finally, the performance of its DFACS (aimed at compensating the disturbing forces and torques applied to the satellite) is the finest ever achieved in low Earth orbit, with residual accelerations along the three axes are lower than $10^{-12} {\rm m/s}^2$ at $f_{\rm{EP}}$ over 8 days.
△ Less
Submitted 22 December, 2020; v1 submitted 11 December, 2020;
originally announced December 2020.
-
MICROSCOPE mission analysis, requirements and expected performance
Authors:
Pierre Touboul,
Manuel Rodrigues,
Gilles Métris,
Ratana Chhun,
Alain Robert,
Quentin Baghi,
Emilie Hardy,
Joel Bergé,
Damien Boulanger,
Bruno Christophe,
Valerio Cipolla,
Bernard Foulon,
Pierre-Yves Guidotti,
Phuong-Anh Huynh,
Vincent Lebat,
Françoise Liorzou,
Benjamin Pouilloux,
Pascal Prieur,
Serge Reynaud
Abstract:
The MICROSCOPE mission aimed to test the Weak Equivalence Principle (WEP) to a precision of $10^{-15}$. The WEP states that two bodies fall at the same rate on a gravitational field independently of their mass or composition. In MICROSCOPE, two masses of different compositions (titanium and platinum alloys) are placed on a quasi-circular trajectory around the Earth. They are the test-masses of a d…
▽ More
The MICROSCOPE mission aimed to test the Weak Equivalence Principle (WEP) to a precision of $10^{-15}$. The WEP states that two bodies fall at the same rate on a gravitational field independently of their mass or composition. In MICROSCOPE, two masses of different compositions (titanium and platinum alloys) are placed on a quasi-circular trajectory around the Earth. They are the test-masses of a double accelerometer. The measurement of their accelerations is used to extract a potential WEP violation that would occur at a frequency defined by the motion and attitude of the satellite around the Earth. This paper details the major drivers of the mission leading to the specification of the major subsystems (satellite, ground segment, instrument, orbit...). Building upon the measurement equation, we derive the objective of the test in statistical and systematic error allocation and provide the mission's expected error budget.
△ Less
Submitted 22 December, 2020; v1 submitted 11 December, 2020;
originally announced December 2020.
-
Space test of the Equivalence Principle: first results of the MICROSCOPE mission
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Quentin Baghi,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Hansjoerg Dittus,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Emilie Hardy,
Phuong-Anh Huynh,
Claus Lämmerzahl,
Vincent Lebat,
Françoise Liorzou,
Meike List,
Isabelle Panet,
Sandrine Pires
, et al. (9 additional authors not shown)
Abstract:
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different co…
▽ More
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different compositions (titanium and platinum alloys) on a quasi-circular trajectory around the Earth. This is realised by measuring the accelerations inferred from the forces required to maintain the two masses exactly in the same orbit. Any significant difference between the measured accelerations, occurring at a defined frequency, would correspond to the detection of a violation of the WEP, or to the discovery of a tiny new type of force added to gravity. MICROSCOPE's first results show no hint for such a difference, expressed in terms of Eötvös parameter $δ(Ti,Pt)=[-1\pm{}9{\rm (stat)}\pm{}9{\rm (syst)}] \times{}10^{-15}$ (both 1$σ$ uncertainties) for a titanium and platinum pair of materials. This result was obtained on a session with 120 orbital revolutions representing 7\% of the current available data acquired during the whole mission. The quadratic combination of 1$σ$ uncertainties leads to a current limit on $δ$ of about $1.3\times{}10^{-14}$.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.
-
The MICROSCOPE mission: first results of a space test of the Equivalence Principle
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Quentin Baghi,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Hansjoerg Dittus,
Pierre Fayet,
Bernard Foulon,
Claude Gageant,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh,
Henri Inchauspe,
Patrick Kayser,
Stéphanie Lala
, et al. (18 additional authors not shown)
Abstract:
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of…
▽ More
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of the Equivalence Principle, or to the discovery of a new long-range force. Analysis of the first data gives $δ\rm{(Ti,Pt)}= [-1 \pm 9 (\mathrm{stat}) \pm 9 (\mathrm{syst})] \times 10^{-15}$ (1$σ$ statistical uncertainty) for the titanium-platinum Eötvös parameter characterizing the relative difference in their free-fall accelerations.
△ Less
Submitted 6 December, 2017; v1 submitted 4 December, 2017;
originally announced December 2017.