-
Hearables: Ear EEG Based Driver Fatigue Detection
Authors:
Metin C. Yarici,
Pierluigi Amadori,
Harry Davies,
Takashi Nakamura,
Nico Lingg,
Yiannis Demiris,
Danilo P. Mandic
Abstract:
Ear EEG based driver fatigue monitoring systems have the potential to provide a seamless, efficient, and feasibly deployable alternative to existing scalp EEG based systems, which are often cumbersome and impractical. However, the feasibility of detecting the relevant delta, theta, alpha, and beta band EEG activity through the ear EEG is yet to be investigated. Through measurements of scalp and ea…
▽ More
Ear EEG based driver fatigue monitoring systems have the potential to provide a seamless, efficient, and feasibly deployable alternative to existing scalp EEG based systems, which are often cumbersome and impractical. However, the feasibility of detecting the relevant delta, theta, alpha, and beta band EEG activity through the ear EEG is yet to be investigated. Through measurements of scalp and ear EEG on ten subjects during a simulated, monotonous driving experiment, this study provides statistical analysis of characteristic ear EEG changes that are associated with the transition from alert to mentally fatigued states, and subsequent testing of a machine learning based automatic fatigue detection model. Novel numerical evidence is provided to support the feasibility of detection of mental fatigue with ear EEG that is in agreement with widely reported scalp EEG findings. This study paves the way for the development of ultra-wearable and readily deployable hearables based driver fatigue monitoring systems.
△ Less
Submitted 16 January, 2023;
originally announced January 2023.
-
Hearables: Feasibility of Recording Cardiac Rhythms from Single Ear Locations
Authors:
Metin Yarici,
Wilhelm Von Rosenberg,
Ghena Hammour,
Harry Davies,
Pierluigi Amadori,
Nico Lingg,
Yiannis Demiris,
Danilo P. Mandic
Abstract:
Wearable technologies are envisaged to provide critical support to future healthcare systems. Hearables - devices worn in the ear - are of particular interest due to their ability to provide health monitoring in an efficient, reliable and unobtrusive way. Despite the considerable potential of these devices, the ECG signal that can be acquired through a hearable device worn on a single ear is still…
▽ More
Wearable technologies are envisaged to provide critical support to future healthcare systems. Hearables - devices worn in the ear - are of particular interest due to their ability to provide health monitoring in an efficient, reliable and unobtrusive way. Despite the considerable potential of these devices, the ECG signal that can be acquired through a hearable device worn on a single ear is still relatively unexplored. Biophysics modelling of ECG volume conduction was used to establish principles behind the single ear ECG signal, and measurements of cardiac rhythms from 10 subjects were found to be in good correspondence with simulated equivalents. Additionally, the viability of the single ear ECG in real-world environments was determined through one hour duration measurements during a simulated driving task on 5 subjects. Results demonstrated that the single ear ECG resembles the Lead I signal, the most widely used ECG signal in the identification of heart conditions such as myocardial infarction and atrial fibrillation, and was robust against real-world measurement noise, even after prolonged measurements. This study conclusively demonstrates that hearables can enable continuous monitoring of vital signs in an unobtrusive and seamless way, with the potential for reliable identification and management of heart conditions such as myocardial infarction and atrial fibrillation.
△ Less
Submitted 6 January, 2023;
originally announced January 2023.
-
Contrastive Self-Supervised Learning for Skeleton Representations
Authors:
Nico Lingg,
Miguel Sarabia,
Luca Zappella,
Barry-John Theobald
Abstract:
Human skeleton point clouds are commonly used to automatically classify and predict the behaviour of others. In this paper, we use a contrastive self-supervised learning method, SimCLR, to learn representations that capture the semantics of skeleton point clouds. This work focuses on systematically evaluating the effects that different algorithmic decisions (including augmentations, dataset partit…
▽ More
Human skeleton point clouds are commonly used to automatically classify and predict the behaviour of others. In this paper, we use a contrastive self-supervised learning method, SimCLR, to learn representations that capture the semantics of skeleton point clouds. This work focuses on systematically evaluating the effects that different algorithmic decisions (including augmentations, dataset partitioning and backbone architecture) have on the learned skeleton representations. To pre-train the representations, we normalise six existing datasets to obtain more than 40 million skeleton frames. We evaluate the quality of the learned representations with three downstream tasks: skeleton reconstruction, motion prediction, and activity classification. Our results demonstrate the importance of 1) combining spatial and temporal augmentations, 2) including additional datasets for encoder training, and 3) and using a graph neural network as an encoder.
△ Less
Submitted 9 November, 2022;
originally announced November 2022.
-
Ultrasound Investigations of Orbital Quadrupolar Ordering in UPd_3
Authors:
N. Lingg,
D. Maurer,
V. Müller,
K. A. McEwen
Abstract:
For a high-quality single crystal of UPd_3 we present the relevant elastic constants and ultrasonic attenuation data. In addition to the magnetic phase transition at T_2=4.4 +/- 0.1K and the quadrupolar transition at T_1~6.8K, we find orbital ordering at T_0=7.6 +/- 0.1K concomitant with a symmetry change from hexagonal to orthorhombic. A striking feature is the splitting of the phase transition…
▽ More
For a high-quality single crystal of UPd_3 we present the relevant elastic constants and ultrasonic attenuation data. In addition to the magnetic phase transition at T_2=4.4 +/- 0.1K and the quadrupolar transition at T_1~6.8K, we find orbital ordering at T_0=7.6 +/- 0.1K concomitant with a symmetry change from hexagonal to orthorhombic. A striking feature is the splitting of the phase transition at T_1 into a second-order transition at T_{+1}=6.9 +/- 0.05K and a first-order transition at T_{-1}=6.7 +/- 0.05K. For the four phase transitions, the quadrupolar order parameters and the respective symmetry changes are specified.
△ Less
Submitted 19 August, 1999;
originally announced August 1999.