Fast Low Rank column-wise Compressive Sensing for Accelerated Dynamic MRI
Authors:
Silpa Babu,
Sajan Goud Lingala,
Namrata Vaswani
Abstract:
This work develops a novel set of algorithms, alternating Gradient Descent (GD) and minimization for MRI (altGDmin-MRI1 and altGDmin-MRI2), for accelerated dynamic MRI by assuming an approximate low-rank (LR) model on the matrix formed by the vectorized images of the sequence. The LR model itself is well-known in the MRI literature; our contribution is the novel GD-based algorithms which are much…
▽ More
This work develops a novel set of algorithms, alternating Gradient Descent (GD) and minimization for MRI (altGDmin-MRI1 and altGDmin-MRI2), for accelerated dynamic MRI by assuming an approximate low-rank (LR) model on the matrix formed by the vectorized images of the sequence. The LR model itself is well-known in the MRI literature; our contribution is the novel GD-based algorithms which are much faster, memory efficient, and general compared with existing work; and careful use of a 3-level hierarchical LR model. By general, we mean that, with a single choice of parameters, our method provides accurate reconstructions for multiple accelerated dynamic MRI applications, multiple sampling rates and sampling schemes.
We show that our methods outperform many of the popular existing approaches while also being faster than all of them, on average. This claim is based on comparisons on 8 different retrospectively under sampled multi-coil dynamic MRI applications, sampled using either 1D Cartesian or 2D pseudo radial under sampling, at multiple sampling rates. Evaluations on some prospectively under sampled datasets are also provided. Our second contribution is a mini-batch subspace tracking extension that can process new measurements and return reconstructions within a short delay after they arrive. The recovery algorithm itself is also faster than its batch counterpart.
△ Less
Submitted 30 May, 2024; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Task-Based Assessment for Neural Networks: Evaluating Undersampled MRI Reconstructions based on Human Observer Signal Detection
Authors:
Joshua D. Herman,
Rachel E. Roca,
Alexandra G. O'Neill,
Marcus L. Wong,
Sajan G. Lingala,
Angel R. Pineda
Abstract:
Recent research has explored using neural networks to reconstruct undersampled magnetic resonance imaging (MRI) data. Because of the complexity of the artifacts in the reconstructed images, there is a need to develop task-based approaches of image quality. Common metrics for evaluating image quality like the normalized root mean squared error (NRMSE) and structural similarity (SSIM) are global met…
▽ More
Recent research has explored using neural networks to reconstruct undersampled magnetic resonance imaging (MRI) data. Because of the complexity of the artifacts in the reconstructed images, there is a need to develop task-based approaches of image quality. Common metrics for evaluating image quality like the normalized root mean squared error (NRMSE) and structural similarity (SSIM) are global metrics which average out impact of subtle features in the images. Using measures of image quality which incorporate a subtle signal for a specific task allow for image quality assessment which locally evaluates the effect of undersampling on a signal. We used a U-Net to reconstruct under-sampled images with 2x, 3x, 4x and 5x fold 1-D undersampling rates. Cross validation was performed for a 500 and a 4000 image training set with both structural similarity (SSIM) and mean squared error (MSE) losses. A two alternative forced choice (2-AFC) observer study was carried out for detecting a subtle signal (small blurred disk) from images with the 4000 image training set. We found that for both loss functions and training set sizes, the human observer performance on the 2-AFC studies led to a choice of a 2x undersampling but the SSIM and NRMSE led to a choice of a 3x undersampling. For this task, SSIM and NRMSE led to an overestimate of the achievable undersampling using a U-Net before a steep loss of image quality when compared to the performance of human observers in the detection of a subtle lesion.
△ Less
Submitted 21 October, 2022;
originally announced October 2022.
-
Modeling human observer detection in undersampled magnetic resonance imaging (MRI) reconstruction with total variation and wavelet sparsity regularization
Authors:
Alexandra G. O'Neill,
Emely L. Valdez,
Sajan Goud Lingala,
Angel R. Pineda
Abstract:
Purpose: Task-based assessment of image quality in undersampled magnetic resonance imaging provides a way of evaluating the impact of regularization on task performance. In this work, we evaluated the effect of total variation (TV) and wavelet regularization on human detection of signals with a varying background and validated a model observer in predicting human performance.
Approach: Human obs…
▽ More
Purpose: Task-based assessment of image quality in undersampled magnetic resonance imaging provides a way of evaluating the impact of regularization on task performance. In this work, we evaluated the effect of total variation (TV) and wavelet regularization on human detection of signals with a varying background and validated a model observer in predicting human performance.
Approach: Human observer studies used two-alternative forced choice (2-AFC) trials with a small signal known exactly task but with varying backgrounds for fluid-attenuated inversion recovery images reconstructed from undersampled multi-coil data. We used a 3.48 undersampling factor with TV and a wavelet sparsity constraints. The sparse difference-of-Gaussians (S-DOG) observer with internal noise was used to model human observer detection.
Results: We observed a trend that the human observer detection performance remained fairly constant for a broad range of values in the regularization parameter before decreasing at large values. A similar result was found for the normalized ensemble root mean squared error. Without changing the internal noise, the model observer tracked the performance of the human observers as the regularization was increased but overestimated the PC for large amounts of regularization for TV and wavelet sparsity, as well as the combination of both parameters.
Conclusions: For the task we studied, the S-DOG observer was able to reasonably predict human performance with both TV and wavelet sparsity regularizers over a broad range of regularization parameters. We observed a trend that task performance remained fairly constant for a range of regularization parameters before decreasing for large amounts of regularization.
△ Less
Submitted 10 March, 2023; v1 submitted 21 October, 2022;
originally announced October 2022.
-
Prospectively accelerated dynamic speech MRI at 3 Tesla using a self-navigated spiral based manifold regularized scheme
Authors:
Rushdi Zahid Rusho,
Abdul Haseeb Ahmed,
Stanley Kruger,
Wahidul Alam,
David Meyer,
David Howard,
Brad Story,
Mathews Jacob,
Sajan Goud Lingala
Abstract:
This work proposes a self-navigated variable density spiral(VDS) based manifold regularization scheme to prospectively improve dynamic speech MRI at 3T. Short readout 1.3ms spirals were used to minimize off-resonance. A custom 16-channel speech coil was used for improved parallel imaging of vocal tract. The manifold model leveraged similarities between frames sharing similar speech postures withou…
▽ More
This work proposes a self-navigated variable density spiral(VDS) based manifold regularization scheme to prospectively improve dynamic speech MRI at 3T. Short readout 1.3ms spirals were used to minimize off-resonance. A custom 16-channel speech coil was used for improved parallel imaging of vocal tract. The manifold model leveraged similarities between frames sharing similar speech postures without explicit motion binning. The self-navigating capability of VDS was leveraged to learn the Laplacian matrix of the manifold. Reconstruction was posed as a SENSE-based non-local soft weighted temporal regularization scheme. Our approach was compared against view-sharing, low-rank, finite difference, extra-dimension-based sparsity reconstruction constraints. Under-sampling experiments were conducted on five volunteers performing repetitive and arbitrary speaking tasks at different speaking rates. Quantitative evaluation in terms of mean square error over moving edges were performed in a retrospectively under-sampled data. For prospective under-sampling, blinded image quality evaluation in the categories of alias artifacts, spatial blurring, and temporal blurring were performed by three voice research experts. Region of interest analysis at articulator boundaries were performed to assess articulatory motion. Our scheme provided improved reconstruction over the others. With prospective under-sampling, a spatial resolution of 2.4mm2/pixel and a temporal resolution of 17.4 ms/frame for single slice imaging, and 52.2 ms/frame for 3-slice imaging were achieved. We demonstrated implicit motion binning by analyzing the mechanics of the Laplacian matrix. Our method demonstrated superior image quality scores in reducing spatial and temporal blurring. While it exhibited faint alias artifacts similar to temporal finite-difference, it provided statistically significant improvements over remaining constraints.
△ Less
Submitted 1 May, 2023; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Fast Low Rank column-wise Compressive Sensing for Accelerated Dynamic MRI
Authors:
Silpa Babu,
Sajan Goud Lingala,
Namrata Vaswani
Abstract:
This work develops a fast, memory-efficient, and general algorithm for accelerated/undersampled dynamic MRI by assuming an approximate LR model on the matrix formed by the vectorized images of the sequence. By general, we mean that our algorithm can be used for multiple accelerated dynamic MRI applications and multiple sampling rates (acceleration rates) and patterns with a single choice of parame…
▽ More
This work develops a fast, memory-efficient, and general algorithm for accelerated/undersampled dynamic MRI by assuming an approximate LR model on the matrix formed by the vectorized images of the sequence. By general, we mean that our algorithm can be used for multiple accelerated dynamic MRI applications and multiple sampling rates (acceleration rates) and patterns with a single choice of parameters (no parameter tuning). We show that our proposed algorithms, alternating Gradient Descent (GD) and minimization for MRI (altGDmin-MRI and altGDmin-MRI2), outperform many existing approaches while also being faster than all of them, on average. This claim is based on comparisons on 8 different retrospectively undersampled single- or multi-coil dynamic MRI applications, undersampled using either 1D Cartesian or 2D pseudo-radial undersampling at multiple sampling rates. All comparisons used the same set of algorithm parameters. Our second contribution is a mini-batch and a fully online extension that can process new measurements and return reconstructions either as soon as measurements of a new image frame arrive, or after a short delay.
△ Less
Submitted 10 August, 2022; v1 submitted 27 June, 2022;
originally announced June 2022.
-
A multispeaker dataset of raw and reconstructed speech production real-time MRI video and 3D volumetric images
Authors:
Yongwan Lim,
Asterios Toutios,
Yannick Bliesener,
Ye Tian,
Sajan Goud Lingala,
Colin Vaz,
Tanner Sorensen,
Miran Oh,
Sarah Harper,
Weiyi Chen,
Yoonjeong Lee,
Johannes Töger,
Mairym Lloréns Montesserin,
Caitlin Smith,
Bianca Godinez,
Louis Goldstein,
Dani Byrd,
Krishna S. Nayak,
Shrikanth S. Narayanan
Abstract:
Real-time magnetic resonance imaging (RT-MRI) of human speech production is enabling significant advances in speech science, linguistics, bio-inspired speech technology development, and clinical applications. Easy access to RT-MRI is however limited, and comprehensive datasets with broad access are needed to catalyze research across numerous domains. The imaging of the rapidly moving articulators…
▽ More
Real-time magnetic resonance imaging (RT-MRI) of human speech production is enabling significant advances in speech science, linguistics, bio-inspired speech technology development, and clinical applications. Easy access to RT-MRI is however limited, and comprehensive datasets with broad access are needed to catalyze research across numerous domains. The imaging of the rapidly moving articulators and dynamic airway sha** during speech demands high spatio-temporal resolution and robust reconstruction methods. Further, while reconstructed images have been published, to-date there is no open dataset providing raw multi-coil RT-MRI data from an optimized speech production experimental setup. Such datasets could enable new and improved methods for dynamic image reconstruction, artifact correction, feature extraction, and direct extraction of linguistically-relevant biomarkers. The present dataset offers a unique corpus of 2D sagittal-view RT-MRI videos along with synchronized audio for 75 subjects performing linguistically motivated speech tasks, alongside the corresponding first-ever public domain raw RT-MRI data. The dataset also includes 3D volumetric vocal tract MRI during sustained speech sounds and high-resolution static anatomical T2-weighted upper airway MRI for each subject.
△ Less
Submitted 15 February, 2021;
originally announced February 2021.
-
Tracer Kinetic Models as Temporal Constraints during DCE-MRI reconstruction
Authors:
Sajan Goud Lingala,
Yi Guo,
R. Marc Lebel,
Yinghua Zhu,
Yannick Bliesener,
Meng Law,
Krishna S. Nayak
Abstract:
Purpose: To apply tracer kinetic models as temporal constraints during reconstruction of under-sampled dynamic contrast enhanced (DCE) MRI.
Methods: A library of concentration v.s time profiles is simulated for a range of physiological kinetic parameters. The library is reduced to a dictionary of temporal bases, where each profile is approximated by a sparse linear combination of the bases. Imag…
▽ More
Purpose: To apply tracer kinetic models as temporal constraints during reconstruction of under-sampled dynamic contrast enhanced (DCE) MRI.
Methods: A library of concentration v.s time profiles is simulated for a range of physiological kinetic parameters. The library is reduced to a dictionary of temporal bases, where each profile is approximated by a sparse linear combination of the bases. Image reconstruction is formulated as estimation of concentration profiles and sparse model coefficients with a fixed sparsity level. Simulations are performed to evaluate modeling error, and error statistics in kinetic parameter estimation in presence of noise. Retrospective under-sampling experiments are performed on a brain tumor DCE digital reference object (DRO) at different signal to noise levels (SNR=20-40) at (k-t) space under-sampling factor (R=20), and 12 brain tumor in- vivo 3T datasets at (R=20-40). The approach is compared against an existing compressed sensing based temporal finite-difference (tFD) reconstruction approach.
Results: Simulations demonstrate that sparsity levels of 2 and 3 model the library profiles from the Patlak and extended Tofts-Kety (ETK) models, respectively. Noise sensitivity analysis showed equivalent kinetic parameter estimation error statistics from noisy concentration profiles, and model approximated profiles. DRO based experiments showed good fidelity in recovery of kinetic maps from 20-fold under- sampled data at SNRs between 10-30. In-vivo experiments demonstrated reduced bias and uncertainty in kinetic map** with the proposed approach compared to tFD at R>=20.
Conclusions: Tracer kinetic models can be applied as temporal constraints during DCE-MRI reconstruction, enabling more accurate reconstruction from under- sampled data. The approach is flexible, can use several kinetic models, and does not require tuning of regularization parameters.
△ Less
Submitted 24 July, 2017;
originally announced July 2017.
-
Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI
Authors:
Sajan Goud Lingala,
Edward DiBella,
Mathews Jacob
Abstract:
We propose a novel deformation corrected compressed sensing (DC-CS) framework to recover dynamic magnetic resonance images from undersampled measurements. We introduce a generalized formulation that is capable of handling a wide class of sparsity/compactness priors on the deformation corrected dynamic signal. In this work, we consider example compactness priors such as sparsity in temporal Fourier…
▽ More
We propose a novel deformation corrected compressed sensing (DC-CS) framework to recover dynamic magnetic resonance images from undersampled measurements. We introduce a generalized formulation that is capable of handling a wide class of sparsity/compactness priors on the deformation corrected dynamic signal. In this work, we consider example compactness priors such as sparsity in temporal Fourier domain, sparsity in temporal finite difference domain, and nuclear norm penalty to exploit low rank structure. Using variable splitting, we decouple the complex optimization problem to simpler and well understood sub problems; the resulting algorithm alternates between simple steps of shrinkage based denoising, deformable registration, and a quadratic optimization step. Additionally, we employ efficient continuation strategies to minimize the risk of convergence to local minima. The proposed formulation contrasts with existing DC-CS schemes that are customized for free breathing cardiac cine applications, and other schemes that rely on fully sampled reference frames or navigator signals to estimate the deformation parameters. The efficient decoupling enabled by the proposed scheme allows its application to a wide range of applications including contrast enhanced dynamic MRI. Through experiments on numerical phantom and in vivo myocardial perfusion MRI datasets, we demonstrate the utility of the proposed DC-CS scheme in providing robust reconstructions with reduced motion artifacts over classical compressed sensing schemes that utilize the compact priors on the original deformation un-corrected signal.
△ Less
Submitted 2 September, 2014; v1 submitted 29 May, 2014;
originally announced May 2014.