Skip to main content

Showing 1–13 of 13 results for author: Lindvall, T

.
  1. arXiv:2306.14781  [pdf, ps, other

    physics.optics physics.atom-ph physics.ins-det

    Noise-induced servo errors in optical clocks utilizing Rabi interrogation

    Authors: T. Lindvall, A. E. Wallin, K. J. Hanhijärvi, T. Fordell

    Abstract: We show that in optical clocks based on Rabi interrogation, both laser-frequency and magnetic-field flicker ($1/f$) noise with zero mean can lead to servo errors at the $10^{-18}$ level if the negative-detuning (red) and positive-detuning (blue) sides of the transition are always probed in the same order. This is due to the strong correlations of flicker noise in combination with an imbalance in t… ▽ More

    Submitted 26 June, 2023; originally announced June 2023.

    Comments: Accepted to Metrologia

    Journal ref: Metrologia 60, 045008 (2023)

  2. arXiv:2212.08687  [pdf, other

    physics.atom-ph quant-ph

    Evaluation of a $^{88}$Sr$^+$ optical clock with a direct measurement of the blackbody radiation shift and determination of the clock frequency

    Authors: M. Steinel, H. Shao, M. Filzinger, B. Lipphardt, M. Brinkmann, A. Didier, T. E. Mehlstäubler, T. Lindvall, E. Peik, N. Huntemann

    Abstract: We report on an evaluation of an optical clock that uses the $\phantom{}^2S_{1/2} \rightarrow \phantom{}^2D_{5/2}$ transition of a single $^{88}$Sr$^+$ ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized se… ▽ More

    Submitted 16 December, 2022; originally announced December 2022.

    Comments: 6 pages, 4 figures

    Journal ref: Phys. Rev. Lett. 131, 083002 (2023)

  3. arXiv:2209.02290  [pdf, ps, other

    physics.atom-ph physics.app-ph

    High-Accuracy Determination of Paul-Trap Stability Parameters for Electric-Quadrupole-Shift Prediction

    Authors: T. Lindvall, K. J. Hanhijärvi, T. Fordell, A. E. Wallin

    Abstract: The motion of an ion in a radiofrequency (rf) Paul trap is described by the Mathieu equation and the associated stability parameters that are proportional to the rf and dc electric field gradients. Here, a higher-order, iterative method to accurately solve the stability parameters from measured secular frequencies is presented. It is then used to characterize an endcap trap by showing that the tra… ▽ More

    Submitted 6 September, 2022; originally announced September 2022.

    Comments: The following article has been accepted by Journal of Applied Physics. After it is published, it will be found at https://doi.org/10.1063/5.0106633. 13 pages, 10 figures

    Journal ref: J. Appl. Phys. 132, 124401 (2022)

  4. arXiv:1906.11495  [pdf, other

    physics.atom-ph

    Guidelines for develo** optical clocks with $10^{-18}$ fractional frequency uncertainty

    Authors: Moustafa Abdel-Hafiz, Piotr Ablewski, Ali Al-Masoudi, Héctor Álvarez Martínez, Petr Balling, Geoffrey Barwood, Erik Benkler, Marcin Bober, Mateusz Borkowski, William Bowden, Roman Ciuryło, Hubert Cybulski, Alexandre Didier, Miroslav Doležal, Sören Dörscher, Stephan Falke, Rachel M. Godun, Ramiz Hamid, Ian R. Hill, Richard Hobson, Nils Huntemann, Yann Le Coq, Rodolphe Le Targat, Thomas Legero, Thomas Lindvall , et al. (20 additional authors not shown)

    Abstract: There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency… ▽ More

    Submitted 13 August, 2019; v1 submitted 27 June, 2019; originally announced June 2019.

    Comments: 130 pages, Table 5.3 corrected in v2

  5. arXiv:1901.08265  [pdf, ps, other

    physics.atom-ph physics.optics

    Broadband lasers for photo-ionization and repum** of trapped ions

    Authors: T. Fordell, T. Lindvall

    Abstract: A frequency-stable, broadband laser is presented for experiments on trapped ions. Since the design is based on widely available semiconductor optical amplifier technology, similar lasers can be realized for virtually any wavelength in the near-infrared, and the coherence properties and output power allow for efficient second harmonic generation. No closed-loop frequency stabilization for addressin… ▽ More

    Submitted 24 January, 2019; originally announced January 2019.

    Comments: JOSA B accepted manuscript (9 pages, 5 figures)

    Journal ref: J.Opt.Soc.Am. B 36, 415 (2019)

  6. arXiv:1801.10134  [pdf, other

    physics.atom-ph

    Measurement of differential polarizabilities at a mid-infrared wavelength in $^{171}\mathrm{Yb}^+$

    Authors: C F A Baynham, E A Curtis, R M Godun, J M Jones, P B R Nisbet-Jones, P E G Baird, K Bongs, P Gill, T Fordell, T Hieta, T Lindvall, M T Spidell, J H Lehman

    Abstract: An atom exposed to an electric field will experience Stark shifts of its internal energy levels, proportional to their polarizabilities. In optical frequency metrology, the Stark shift due to background black-body radiation (BBR) modifies the frequency of the optical clock transition, and often represents a large contribution to a clock's uncertainty budget. For clocks based on singly-ionized ytte… ▽ More

    Submitted 10 September, 2020; v1 submitted 30 January, 2018; originally announced January 2018.

  7. arXiv:1705.04817  [pdf, other

    physics.app-ph cond-mat.mes-hall physics.ins-det

    The spin resonance clock transition of the endohedral fullerene $^{15}\mathrm{N@C}_{60}$

    Authors: R. T. Harding, S. Zhou, J. Zhou, T. Lindvall, W. K. Myers, A. Ardavan, G. A. D. Briggs, K. Porfyrakis, E. A. Laird

    Abstract: The endohedral fullerene $^{15}\mathrm{N@C}_{60}$ has narrow electron paramagnetic resonance lines which have been proposed as the basis for a condensed-matter portable atomic clock. We measure the low-frequency spectrum of this molecule, identifying and characterizing a clock transition at which the frequency becomes insensitive to magnetic field. We infer a linewidth at the clock field of 100 kH… ▽ More

    Submitted 13 May, 2017; originally announced May 2017.

    Comments: 6 pages, 5 figures. Supplementary information: 2 pages, 1 figure

    Journal ref: Phys. Rev. Lett. 119, 140801 (2017)

  8. arXiv:1510.05556  [pdf

    physics.atom-ph physics.ins-det

    Analysis of thermal radiation in ion traps for optical frequency standards

    Authors: Miroslav Doležal, Petr Balling, Peter B R Nisbet-Jones, Steven A King, Jonathan M Jones, Hugh A Klein, Patrick Gill, Thomas Lindvall, Anders E Wallin, Mikko Merimaa, Christian Tamm, Christian Sanner, Nils Huntemann, Nils Scharnhorst, Ian D Leroux, Piet O Schmidt, Tobias Burgermeister, Tanja E Mehlstäubler, Ekkehard Peik

    Abstract: In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of… ▽ More

    Submitted 6 November, 2015; v1 submitted 19 October, 2015; originally announced October 2015.

    Comments: 16 pages, submitted to Metrologia

    Journal ref: Metrologia 52 (2015) 842-56

  9. arXiv:1504.04443  [pdf, ps, other

    physics.atom-ph

    Broadband, unpolarized repum** and clearout light sources for Sr$^+$ single-ion clocks

    Authors: T. Fordell, T. Lindvall, P. Dubé, A. A. Madej, A. E. Wallin, M. Merimaa

    Abstract: Future transportable optical clocks require compact and reliable light sources. Here, broadband, unpolarized repumper and state clearout sources for Sr+ single-ion optical clocks are reported. These turn-key devices require no frequency stabilization nor external modulators. They are fiber based, inexpensive, and compact. Key characteristics for clock operation are presented, including optical spe… ▽ More

    Submitted 17 April, 2015; originally announced April 2015.

    Comments: 4 pages, 6 figures

    Journal ref: Optics Letters, Vol. 40, Issue 8, pp. 1822-1825 (2015)

  10. arXiv:1301.5503  [pdf, ps, other

    physics.atom-ph quant-ph

    Unpolarized, incoherent repum** light for prevention of dark states in a trapped and laser-cooled single ion

    Authors: T. Lindvall, T. Fordell, I. Tittonen, M. Merimaa

    Abstract: Many ion species commonly used for laser-cooled ion trap** studies have a low-lying metastable 2D3/2 state that can become populated due to spontaneous emission from the 2P1/2 excited state. This requires a repumper laser to maintain the ion in the Doppler cooling cycle. Typically the 2D3/2 state, or some of its hyperfine components if the ion has nuclear spin, has a higher multiplicity than the… ▽ More

    Submitted 1 February, 2013; v1 submitted 23 January, 2013; originally announced January 2013.

    Journal ref: Phys. Rev. A 87, 013439 (2013)

  11. arXiv:1212.4685  [pdf, ps, other

    physics.atom-ph quant-ph

    Dark-state suppression and optimization of laser cooling and fluorescence in a trapped alkaline-earth-metal single ion

    Authors: T. Lindvall, M. Merimaa, I. Tittonen, A. A. Madej

    Abstract: We study the formation and destabilization of dark states in a single trapped 88Sr+ ion caused by the cooling and repum** laser fields required for Doppler cooling and fluorescence detection of the ion. By numerically solving the time-dependent density matrix equations for the eight-level system consisting of the sublevels of the 5s 2S1/2, 5p 2P1/2, and 4d 2D3/2 states, we analyze the different… ▽ More

    Submitted 19 December, 2012; originally announced December 2012.

    Journal ref: Phys. Rev. A 86, 033403 (2012)

  12. arXiv:0810.0599  [pdf, ps, other

    math.PR

    Translated Poisson approximation for Markov chains

    Authors: A. D. Barbour, Torgny Lindvall

    Abstract: The paper is concerned with approximating the distribution of a sum W of n integer valued random variables Y_i, whose distributions depend on the state of an underlying Markov chain X. The approximation is in terms of a translated Poisson distribution, with mean and variance chosen to be close to those of W, and the error is measured with respect to the total variation norm. Error bounds compara… ▽ More

    Submitted 3 October, 2008; originally announced October 2008.

    Comments: 25 pages. Corrected version of Journal of Theoretical Probability 19, 609-630 (2006): both statement and proof of Lemma 4.1 have been altered

    MSC Class: 62E17 (Primary) 60J10; 60F05

  13. Trap** atoms on a transparent permanent-magnet atom chip

    Authors: A. Shevchenko, M. Heilio, T. Lindvall, A. Jaakkola, I. Tittonen, M. Kaivola, T. Pfau

    Abstract: We describe experiments on trap** of atoms in microscopic magneto-optical traps on an optically transparent permanent-magnet atom chip. The chip is made of magnetically hard ferrite-garnet material deposited on a dielectric substrate. The confining magnetic fields are produced by miniature magnetized patterns recorded in the film by magneto-optical techniques. We trap Rb atoms on these structu… ▽ More

    Submitted 21 April, 2006; v1 submitted 24 January, 2006; originally announced January 2006.

    Comments: Modifications: A) Reference I. Barb et al., Eur. Phys. JD, 35, 75 (2005) added. B)Sentence rewritten: We routinely capture more than 10^6 atoms in a micro-MOT on a magnetized pattern. C) The magnetic field strengths are now given in Teslas. D) The second sentence in the fourth paragraph has been rewritten in order to more clearly describe the geometry and purpose of the compensation coils.E) In the seventh paragraph we have rewritten the sentence about the creation of the external magnetic field for the magnetic-domain patterning. F) In the ninth paragraph, we clarify the way to shift the trap center. G) Caption of Fig. 4 changed. H) We have modified paragraph 12 to improve the description on the guiding of the trap center along a toroidal pattern. I) The last two sentences of the manuscript have been rewritten