-
XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad,
J. J. Cuenca-García,
V. D'Andrea
, et al. (139 additional authors not shown)
Abstract:
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 t…
▽ More
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Proportional scintillation in liquid xenon: demonstration in a single-phase liquid-only time projection chamber
Authors:
Florian Tönnies,
Adam Brown,
Baris Kiyim,
Fabian Kuger,
Sebastian Lindemann,
Patrick Meinhardt,
Marc Schumann,
Andrew Stevens
Abstract:
The largest direct dark matter search experiments to date employ dual-phase time projection chambers (TPCs) with liquid noble gas targets. These detect both the primary photons generated by particle interactions in the liquid target, as well as proportional secondary scintillation light created by the ionization electrons in a strong electric field in the gas phase between the liquid-gas interface…
▽ More
The largest direct dark matter search experiments to date employ dual-phase time projection chambers (TPCs) with liquid noble gas targets. These detect both the primary photons generated by particle interactions in the liquid target, as well as proportional secondary scintillation light created by the ionization electrons in a strong electric field in the gas phase between the liquid-gas interface and the anode. In this work, we describe the detection of charge signals in a small-scale single-phase liquid-xenon-only TPC, that features the well-established TPC geometry with light readout above and below a cylindrical target. In the single-phase TPC, the proportional scintillation light (S2) is generated in liquid xenon in close proximity to 10 μm diameter anode wires. The detector was characterized and the proportional scintillation process was studied using the 32.1 keV and 9.4 keV signals from Kr-83m decays. A charge gain factor g2 of up to (1.9 $\pm$ 0.3) PE/electron was reached at an anode voltage 4.4 kV higher than the gate electrode, corresponding to (29 $\pm$ 6) photons emitted per ionization electron. The duration of S2 signals is dominated by electron diffusion and approaches the xenon de-excitation timescale for very short electron drift times. The electron drift velocity and the longitudinal diffusion constant were measured at a drift field of 470 V/cm. The results agree with the literature and demonstrate that a single-phase TPC can be operated successfully.
△ Less
Submitted 17 May, 2024;
originally announced May 2024.
-
Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon detectors
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
G. Bruno,
R. Budnik,
T. K. Bui,
J. M. R. Cardoso,
A. P. Cimental Chavez,
A. P. Colijn,
J. Conrad
, et al. (142 additional authors not shown)
Abstract:
This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity…
▽ More
This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity field, $^{214}\text{Pb}$ background events can be tagged when they are followed by $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays, or preceded by $^{218}\text{Po}$ decays. This was achieved by evolving a point cloud in the direction of a measured convection velocity field, and searching for $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays or $^{218}\text{Po}$ decays within a volume defined by the point cloud. In XENON1T, this tagging system achieved a $^{214}\text{Pb}$ background reduction of $6.2^{+0.4}_{-0.9}\%$ with an exposure loss of $1.8\pm 0.2 \%$, despite the timescales of convection being smaller than the relevant decay times. We show that the performance can be improved in XENONnT, and that the performance of such a software-tagging approach can be expected to be further improved in a diffusion-limited scenario. Finally, a similar method might be useful to tag the cosmogenic $^{137}\text{Xe}$ background, which is relevant to the search for neutrinoless double-beta decay.
△ Less
Submitted 19 June, 2024; v1 submitted 21 March, 2024;
originally announced March 2024.
-
The XENONnT Dark Matter Experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
M. Balata,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui
, et al. (170 additional authors not shown)
Abstract:
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in…
▽ More
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
PANCAKE: a large-diameter cryogenic test platform with a flat floor for next generation multi-tonne liquid xenon detectors
Authors:
Adam Brown,
Horst Fischer,
Robin Glade-Beucke,
Jaron Grigat,
Fabian Kuger,
Sebastian Lindemann,
Tiffany Luce,
Darryl Masson,
Julia Müller,
Jens Reininghaus,
Marc Schumann,
Andrew Stevens,
Florian Tönnies,
Francesco Toschi
Abstract:
The PANCAKE facility is the world's largest liquid xenon test platform. Inside its cryostat with an internal diameter of 2.75 m, components for the next generation of liquid xenon experiments, such as DARWIN or XLZD, will be tested at their full scale. This is essential to ensure their successful operation. This work describes the facility, including its cryostat, cooling systems, xenon handling i…
▽ More
The PANCAKE facility is the world's largest liquid xenon test platform. Inside its cryostat with an internal diameter of 2.75 m, components for the next generation of liquid xenon experiments, such as DARWIN or XLZD, will be tested at their full scale. This is essential to ensure their successful operation. This work describes the facility, including its cryostat, cooling systems, xenon handling infrastructure, and its monitoring and instrumentation. The inner vessel has a flat floor, which allows the full diameter to be used with a modest amount of xenon. This is a novel approach for such a large cryostat and is of interest for future large-scale experiments, where a standard torispherical head would require tonnes of additional xenon. Our current xenon inventory of 400 kg allows a liquid depth of about 2 cm in the inner cryostat vessel. We also describe the commissioning of the facility, which is now ready for component testing.
△ Less
Submitted 15 May, 2024; v1 submitted 22 December, 2023;
originally announced December 2023.
-
Design and performance of the field cage for the XENONnT experiment
Authors:
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso,
D. Cichon
, et al. (139 additional authors not shown)
Abstract:
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to t…
▽ More
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field sha** ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to ${}^{83m}\mathrm{Kr}$ calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
A High-Sensitivity Radon Emanation Detector System for Future Low-Background Experiments
Authors:
D. Wiebe,
S. Lindemann,
M. Schumann
Abstract:
Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes can significantly contribute to the background of low-background experiments. The $^{222}\mathrm{Rn}$ progeny $^{214}\mathrm{Pb}$, for example, dominates the ba…
▽ More
Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes can significantly contribute to the background of low-background experiments. The $^{222}\mathrm{Rn}$ progeny $^{214}\mathrm{Pb}$, for example, dominates the background of current liquid xenon-based direct dark matter detectors. We report on a new detector system to directly quantify the $^{222}\mathrm{Rn}$ surface emanation rate of materials. Using cryogenic physisorption traps, emanated radon atoms are transferred from an independent emanation vessel and concentrated within the dedicated detection vessel. The charged daughter isotopes are collected electrostatically on a silicon PIN photodiode to spectrometrically measure the alpha decays of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$. The overall detection efficiency is $\sim 36\,\%$ for both polonium channels. The radon emanation activity of the emanation vessel was measured to be $(0.16\pm 0.03)\,\mathrm{mBq}$, resulting in a detection sensitivity of $\sim 0.06\,\mathrm{mBq}$ at $90\,\%\,\mathrm{C.L.}$.
△ Less
Submitted 28 January, 2024; v1 submitted 8 September, 2023;
originally announced September 2023.
-
Cosmogenic background simulations for the DARWIN observatory at different underground locations
Authors:
M. Adrover,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
B. Antunovic,
E. Aprile,
M. Babicz,
D. Bajpai,
E. Barberio,
L. Baudis,
M. Bazyk,
N. Bell,
L. Bellagamba,
R. Biondi,
Y. Biondi,
A. Bismark,
C. Boehm,
A. Breskin,
E. J. Brookes,
A. Brown,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso
, et al. (158 additional authors not shown)
Abstract:
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are…
▽ More
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.
△ Less
Submitted 28 June, 2023;
originally announced June 2023.
-
Search for events in XENON1T associated with Gravitational Waves
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antoń Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (138 additional authors not shown)
Abstract:
We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW1…
▽ More
We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW170823. We use this null result to constrain mono-energetic neutrinos and Beyond Standard Model particles emitted in the closest coalescence GW170817, a binary neutron star merger. We set new upper limits on the fluence (time-integrated flux) of coincident neutrinos down to 17 keV at 90% confidence level. Furthermore, we constrain the product of coincident fluence and cross section of Beyond Standard Model particles to be less than $10^{-29}$ cm$^2$/cm$^2$ in the [5.5-210] keV energy range at 90% confidence level.
△ Less
Submitted 27 October, 2023; v1 submitted 20 June, 2023;
originally announced June 2023.
-
Searching for Heavy Dark Matter near the Planck Mass with XENON1T
Authors:
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso,
D. Cichon
, et al. (142 additional authors not shown)
Abstract:
Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.…
▽ More
Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This work places strong constraints on spin-independent interactions of dark matter particles with a mass between 1$\times$10$^{12}\,$GeV/c$^2$ and 2$\times$10$^{17}\,$GeV/c$^2$. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross-sections for dark matter particles with masses close to the Planck scale.
△ Less
Submitted 21 April, 2023;
originally announced April 2023.
-
Detector signal characterization with a Bayesian network in XENONnT
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (142 additional authors not shown)
Abstract:
We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ioniz…
▽ More
We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ionization process. We describe the method and its performance on electronic-recoil (ER) data taken during the first science run of the XENONnT dark matter experiment. We demonstrate the first use of a Bayesian network in a waveform-based analysis of detector signals. This method resulted in a 3% increase in ER event-selection efficiency with a simultaneously effective rejection of events outside of the region of interest. The findings of this analysis are consistent with the previous analysis from XENONnT, namely a background-only fit of the ER data.
△ Less
Submitted 26 July, 2023; v1 submitted 11 April, 2023;
originally announced April 2023.
-
First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai
, et al. (141 additional authors not shown)
Abstract:
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid targe…
▽ More
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid target were reduced to unprecedentedly low levels, giving an electronic recoil background rate of $(15.8\pm1.3)~\mathrm{events}/(\mathrm{t\cdot y \cdot keV})$ in the region of interest. A blind analysis of nuclear recoil events with energies between $3.3$ keV and $60.5$ keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of $2.58\times 10^{-47}~\mathrm{cm}^2$ for a WIMP mass of $28~\mathrm{GeV}/c^2$ at $90\%$ confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.
△ Less
Submitted 5 August, 2023; v1 submitted 26 March, 2023;
originally announced March 2023.
-
The Triggerless Data Acquisition System of the XENONnT Experiment
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
J. M. R. Cardoso
, et al. (140 additional authors not shown)
Abstract:
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commerc…
▽ More
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at $\times10$ and $\times0.5$ gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within $\mathcal{O}\left(10\text{ s}\right)$ for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed $\sim500$ MB/s during calibration. Livetime during normal operation exceeds $99\%$ and is $\sim90\%$ during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
C. Capelli,
J. M. R. Cardoso
, et al. (139 additional authors not shown)
Abstract:
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respecti…
▽ More
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0$^{+6.3}_{-3.7}$) electrons/keV. The $^{37}$Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83$\pm$0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $^{37}$Ar can be considered as a regular calibration source for multi-tonne xenon detectors.
△ Less
Submitted 21 March, 2023; v1 submitted 25 November, 2022;
originally announced November 2022.
-
Effective Field Theory and Inelastic Dark Matter Results from XENON1T
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
M. Clark
, et al. (135 additional authors not shown)
Abstract:
In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1\,tonne$\times$year exposure. For these analyses, we extended the region of inter…
▽ More
In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1\,tonne$\times$year exposure. For these analyses, we extended the region of interest from [4.9, 40.9]$\,$keV$_{\text{NR}}$ to [4.9, 54.4]$\,$keV$_{\text{NR}}$ to enhance our sensitivity for signals that peak at nonzero energies. We show that the data is consistent with the background-only hypothesis, with a small background over-fluctuation observed peaking between 20 and 50$\,$keV$_{\text{NR}}$, resulting in a maximum local discovery significance of 1.7\,$σ$ for the Vector$\otimes$Vector$_{\text{strange}}$ ($VV_s$) ChEFT channel for a dark matter particle of 70$\,$GeV/c$^2$, and $1.8\,σ$ for an iDM particle of 50$\,$GeV/c$^2$ with a mass splitting of 100$\,$keV/c$^2$. For each model, we report 90\,\% confidence level (CL) upper limits. We also report upper limits on three benchmark models of dark matter interaction using ChEFT where we investigate the effect of isospin-breaking interactions. We observe rate-driven cancellations in regions of the isospin-breaking couplings, leading to up to 6 orders of magnitude weaker upper limits with respect to the isospin-conserving case.
△ Less
Submitted 17 October, 2022; v1 submitted 14 October, 2022;
originally announced October 2022.
-
An approximate likelihood for nuclear recoil searches with XENON1T data
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (129 additional authors not shown)
Abstract:
The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method…
▽ More
The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihood and therefore most statistical results for any nuclear recoil spectrum. Computing approximate results with this method is approximately three orders of magnitude faster than the likelihood used in the original publications of XENON1T, where limits were set for specific families of recoil spectra. Using this same method, we include toy Monte Carlo simulation-derived binwise likelihoods for the upcoming XENONnT experiment that can similarly be used to assess the sensitivity to arbitrary nuclear recoil signatures in its eventual 20 tonne-year exposure.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
DELight: a Direct search Experiment for Light dark matter with superfluid helium
Authors:
Belina von Krosigk,
Klaus Eitel,
Christian Enss,
Torben Ferber,
Loredana Gastaldo,
Felix Kahlhoefer,
Sebastian Kempf,
Markus Klute,
Sebastian Lindemann,
Marc Schumann,
Francesco Toschi,
Kathrin Valerius
Abstract:
To reach ultra-low detection thresholds necessary to probe unprecedentedly low Dark Matter masses, target material alternatives and novel detector designs are essential. One such target material is superfluid $^4$He which has the potential to probe so far uncharted light Dark Matter parameter space at sub-GeV masses. The new ``Direct search Experiment for Light dark matter'', DELight, will be usin…
▽ More
To reach ultra-low detection thresholds necessary to probe unprecedentedly low Dark Matter masses, target material alternatives and novel detector designs are essential. One such target material is superfluid $^4$He which has the potential to probe so far uncharted light Dark Matter parameter space at sub-GeV masses. The new ``Direct search Experiment for Light dark matter'', DELight, will be using superfluid helium as active target, instrumented with magnetic micro-calorimeters. It is being designed to reach sensitivity to masses well below 100\,MeV in Dark Matter-nucleus scattering interactions.
△ Less
Submitted 22 September, 2022;
originally announced September 2022.
-
Reduction of $^{222}$Rn-induced Backgrounds in a Hermetic Dual-Phase Xenon Time Projection Chamber
Authors:
Julia Dierle,
Adam Brown,
Horst Fischer,
Robin Glade-Beucke,
Jaron Grigat,
Fabian Kuger,
Sebastian Lindemann,
Mariana Rajado Silva,
Marc Schumann
Abstract:
The continuous emanation of $^{222}$Rn from detector surfaces causes the dominant background in current liquid xenon time projection chambers (TPCs) searching for dark matter. A significant reduction is required for the next generation of detectors which are aiming to reach the neutrino floor, such as DARWIN. $^{222}$Rn-induced back\-grounds can be reduced using a hermetic TPC, in which the sensit…
▽ More
The continuous emanation of $^{222}$Rn from detector surfaces causes the dominant background in current liquid xenon time projection chambers (TPCs) searching for dark matter. A significant reduction is required for the next generation of detectors which are aiming to reach the neutrino floor, such as DARWIN. $^{222}$Rn-induced back\-grounds can be reduced using a hermetic TPC, in which the sensitive target volume is mechanically separated from the rest of the detector containing the majority of Rn-emanating surfaces. We present a hermetic TPC that mainly follows the well-established design of leading xenon TPCs and has been operated successfully over a period of several weeks. By scaling up the results achieved to the DARWIN-scale, we show that the hermetic TPC concept can reduce the $^{222}$Rn concentration to the required level, even with imperfect separation of the volumes.
△ Less
Submitted 1 September, 2022;
originally announced September 2022.
-
The XeBRA platform for liquid xenon time projection chamber development
Authors:
Daniel Baur,
Alexander Bismark,
Adam Brown,
Julia Dierle,
Horst Fischer,
Robin Glade-Beucke,
Jaron Grigat,
Basho Kaminsky,
Fabian Kuger,
Sebastian Lindemann,
Darryl Masson,
Patrick Meinhardt,
Mariana Rajado Silva,
Marc Schumann,
Florian Tönnies,
Francesco Toschi
Abstract:
XeBRA is a flexible cryogenic platform designed to perform research and development for liquid xenon detectors searching for rare events. Its extra-large outer cryostat makes it possible to install a wide variety of detector designs. We present the system, including its cryogenic, gas handling, data acquisition and slow control subsystems. Two dual phase time projection chambers with sensitive mas…
▽ More
XeBRA is a flexible cryogenic platform designed to perform research and development for liquid xenon detectors searching for rare events. Its extra-large outer cryostat makes it possible to install a wide variety of detector designs. We present the system, including its cryogenic, gas handling, data acquisition and slow control subsystems. Two dual phase time projection chambers with sensitive masses at the 1 kg scale have so far been operated in XeBRA. Using data from these, we determine the field-dependence of the electron drift velocity in liquid xenon. We also measure the relative charge and light yields for 41.5 keV energy deposits from Kr-83m with electric drift fields between 50 V/cm and 677 V/cm.
△ Less
Submitted 9 February, 2023; v1 submitted 31 August, 2022;
originally announced August 2022.
-
Search for New Physics in Electronic Recoil Data from XENONnT
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (141 additional authors not shown)
Abstract:
We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XE…
▽ More
We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XENON1T. With an exposure of 1.16 tonne-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.
△ Less
Submitted 15 November, 2022; v1 submitted 22 July, 2022;
originally announced July 2022.
-
Double-Weak Decays of $^{124}$Xe and $^{136}$Xe in the XENON1T and XENONnT Experiments
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (135 additional authors not shown)
Abstract:
We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a…
▽ More
We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a $0.87\;\text{kg}\times\text{yr}$ isotope exposure. The statistical significance of the signal is $7.0\,σ$. We use XENON1T data with $36.16\;\text{kg}\times\text{yr}$ of $^{136}$Xe exposure to search for $0νββ$. We find no evidence of a signal and set a lower limit on the half-life of $T_{1/2}^{0νββ} > 1.2 \times 10^{24}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to $0νββ$. Assuming a $275\;\text{kg}\times\text{yr}$ $^{136}$Xe exposure, the expected sensitivity is $T_{1/2}^{0νββ} > 2.1 \times 10^{25}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$, corresponding to an effective Majorana mass range of $\langle m_{ββ} \rangle < (0.19 - 0.59)\;\text{eV/c}^2$.
△ Less
Submitted 6 September, 2022; v1 submitted 9 May, 2022;
originally announced May 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
GeMSE: a Low-Background Facility for Gamma-Spectrometry at Moderate Rock Overburden
Authors:
Diego Ramírez García,
Daniel Baur,
Jaron Grigat,
Beda A. Hofmann,
Sebastian Lindemann,
Darryl Masson,
Marc Schumann,
Moritz von Sivers,
Francesco Toschi
Abstract:
The GeMSE (Germanium Material and meteorite Screening Experiment) facility operates a low-background HPGe crystal in an underground laboratory with a moderate rock overburden of 620$\,$m.w.e. in Switzerland. It has been optimized for continuous remote operation. A multi-layer passive shielding, a muon veto, and a boil-off nitrogen purge line inside the measurement cavity minimize the instrument's…
▽ More
The GeMSE (Germanium Material and meteorite Screening Experiment) facility operates a low-background HPGe crystal in an underground laboratory with a moderate rock overburden of 620$\,$m.w.e. in Switzerland. It has been optimized for continuous remote operation. A multi-layer passive shielding, a muon veto, and a boil-off nitrogen purge line inside the measurement cavity minimize the instrument's background rate, which decreased by 33% to (164$\pm$2)$\,$counts/day (100-2700$\,$keV) after five years of underground operation. This agrees with the prediction based on the expected decay of short-lived isotopes. A fit to the known background components, modeled via a precise simulation of the detector, shows that the GeMSE background is now muon-dominated. We also present updates towards a more accurate detection efficiency calculation for the screened samples: the thickness of the crystal's outer dead-layer is precisely determined and the efficiency can now be easily calculated for any sample geometry. The advantage of this feature is showcased via the determination of the $^{40}$K content in the screening of a complex-shaped object: a banana.
△ Less
Submitted 11 April, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Application and modeling of an online distillation method to reduce krypton and argon in XENON1T
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
A. Bernard,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (129 additional authors not shown)
Abstract:
A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of…
▽ More
A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.
△ Less
Submitted 14 June, 2022; v1 submitted 22 December, 2021;
originally announced December 2021.
-
Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
A. Bernard,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (130 additional authors not shown)
Abstract:
Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effe…
▽ More
Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates < 30 events/(electron*kg*day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.
△ Less
Submitted 28 June, 2022; v1 submitted 22 December, 2021;
originally announced December 2021.
-
Material radiopurity control in the XENONnT experiment
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino,
M. Clark
, et al. (128 additional authors not shown)
Abstract:
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove…
▽ More
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,μ$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.
△ Less
Submitted 26 January, 2023; v1 submitted 10 December, 2021;
originally announced December 2021.
-
Microscopic piezoelectric behavior of clamped and membrane (001) PMN-30PT thin films
Authors:
A. Brewer,
S. Lindemann,
B. Wang,
W. Maeng,
J. Frederick,
F. Li,
Y. Choi,
P. J. Thompson,
J. W. Kim,
T. Mooney,
V. Vaithyanathan,
D. G. Schlom,
M. S. Rzchowski,
L. Q. Chen,
P. J. Ryan,
C. B. Eom
Abstract:
Bulk single-crystal relaxor-ferroelectrics, like Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT), are widely known for their large piezoelectricity. This is attributed to polarization rotation which is facilitated by the presence of various crystal symmetries for compositions near a morphotropic phase boundary (MPB). Relaxor-ferroelectric thin films, which are necessary for low-voltage applications, suffer a red…
▽ More
Bulk single-crystal relaxor-ferroelectrics, like Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT), are widely known for their large piezoelectricity. This is attributed to polarization rotation which is facilitated by the presence of various crystal symmetries for compositions near a morphotropic phase boundary (MPB). Relaxor-ferroelectric thin films, which are necessary for low-voltage applications, suffer a reduction in their piezoelectric response due to clam** by the passive substrate. To understand the microscopic behavior of this adverse phenomenon, we employ AC electric field driven in-operando synchrotron x-ray diffraction (XRD) on patterned device structures to investigate the piezoelectric domain behavior under an electric field for both a clamped (001) PMN-PT thin film on Si and a (001) PMN-PT membrane released from its substrate. In the clamped film, the substrate inhibits the field induced rhombohedral (R) to tetragonal (T) phase transition resulting in a reversible R to Monoclinic (M) transition with a reduced longitudinal piezoelectric coefficient d33 < 100 pm/V. Releasing the film from the substrate results in recovery of the R to T transition and results in a d33 > 1000 pm/V. Using diffraction with spatial map**, we find that lateral constraints imposed by the boundary between active and inactive material also inhibits the R to T transition. Phase-field calculations on both clamped and released PMN-PT thin films simulate our experimental findings. Resolving the suppression of thin film piezoelectric response is critical to their application in piezo-driven technologies.
△ Less
Submitted 16 October, 2021;
originally announced October 2021.
-
Low-Voltage Magnetoelectric Coupling in Membrane Heterostructures
Authors:
S. Lindemann,
J. Irwin,
G. -Y. Kim,
B. Wang,
K. Eom,
J. J. Wang,
J. M. Hu,
L. Q. Chen,
S. Y. Choi,
C. B. Eom,
M. S. Rzchowski
Abstract:
Strain-mediated magnetoelectric (ME) coupling in ferroelectric (FE) / ferromagnetic (FM) heterostructures offers a unique opportunity for both fundamental scientific research and low power multifunctional devices. Relaxor-ferroelectrics, like (1-x)Pb(Mg1/3Nb2/3)O3-(x)PbTiO3 (PMN-xPT), are ideal FE layer candidates due to their giant piezoelectricity. But thin films of PMN-PT suffer from substrate…
▽ More
Strain-mediated magnetoelectric (ME) coupling in ferroelectric (FE) / ferromagnetic (FM) heterostructures offers a unique opportunity for both fundamental scientific research and low power multifunctional devices. Relaxor-ferroelectrics, like (1-x)Pb(Mg1/3Nb2/3)O3-(x)PbTiO3 (PMN-xPT), are ideal FE layer candidates due to their giant piezoelectricity. But thin films of PMN-PT suffer from substrate clam** which substantially reduces piezoelectric in-plane strains. Here we present the first demonstration of low voltage ME coupling in an all-thin-film heterostructure which utilizes the anisotropic strains induced by the (011) orientation of PMN-PT. We completely remove PMN-PT films from their substrate and couple with FM Ni overlayers to create membrane PMN-PT/Ni heterostructures showing 90 degree Ni magnetization rotation with 3V PMN-PT bias, much less than the bulk PMNPT ~100V requirement. Scanning transmission electron microscopy and phase-field simulations clarify the membrane response. These results provide a crucial step towards understanding the microstructural behavior of PMN-PT thin films for use in piezo-driven magnetoelectric heterostructures.
△ Less
Submitted 11 October, 2021;
originally announced October 2021.
-
In-plane quasi-single-domain BaTiO$_3$ via interfacial symmetry engineering
Authors:
J. W. Lee,
K. Eom,
T. R. Paudel,
B. Wang,
H. Lu,
H. Huyan,
S. Lindemann,
S. Ryu,
H. Lee,
T. H. Kim,
Y. Yuan,
J. A. Zorn,
S. Lei,
W. Gao,
T. Tybell,
V. Gopalan,
X. Pan,
A. Gruverman,
L. Q. Chen,
E. Y. Tsymbal,
C. B. Eom
Abstract:
The control of the in-plane domain evolution in ferroelectric thin films is not only critical to understanding ferroelectric phenomena but also to enabling functional device fabrication. However, in-plane polarized ferroelectric thin films typically exhibit complicated multi-domain states, not desirable for optoelectronic device performance. Here we report a strategy combining interfacial symmetry…
▽ More
The control of the in-plane domain evolution in ferroelectric thin films is not only critical to understanding ferroelectric phenomena but also to enabling functional device fabrication. However, in-plane polarized ferroelectric thin films typically exhibit complicated multi-domain states, not desirable for optoelectronic device performance. Here we report a strategy combining interfacial symmetry engineering and anisotropic strain to design single-domain, in-plane polarized ferroelectric BaTiO$_3$ thin films. Theoretical calculations predict the key role of the BaTiO$_3$ / PrScO$_3$ (110)$_O$ substrate interfacial environment, where anisotropic strain, monoclinic distortions, and interfacial electrostatic potential stabilize a single-variant spontaneous polarization. A combination of scanning transmission electron microscopy, piezoresponse force microscopy, ferroelectric hysteresis loop measurements, and second harmonic generation measurements directly reveals the stabilization of the in-plane quasi-single-domain polarization state. This work offers design principles for engineering in-plane domains of ferroelectric oxide thin films, which is a prerequisite for high performance optoelectronic devices.
△ Less
Submitted 16 September, 2021;
originally announced September 2021.
-
Search for Coherent Elastic Scattering of Solar $^8$B Neutrinos in the XENON1T Dark Matter Experiment
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
S. Andaloro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (113 additional authors not shown)
Abstract:
We report on a search for nuclear recoil signals from solar $^8$B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 keV to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant $^8$B neutrino-like excess is found in an exposure of 0.6 t $\times$ y. For the first tim…
▽ More
We report on a search for nuclear recoil signals from solar $^8$B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 keV to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant $^8$B neutrino-like excess is found in an exposure of 0.6 t $\times$ y. For the first time, we use the non-detection of solar neutrinos to constrain the light yield from 1-2 keV nuclear recoils in liquid xenon, as well as non-standard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 GeV/c$^2$ and 11 GeV/c$^2$ by as much as an order of magnitude.
△ Less
Submitted 15 March, 2021; v1 submitted 4 December, 2020;
originally announced December 2020.
-
Search for inelastic scattering of WIMP dark matter in XENON1T
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
S. Andaloro,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (116 additional authors not shown)
Abstract:
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of i…
▽ More
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of inelastic WIMP scattering with a significance of more than 2$σ$. A profile-likelihood ratio analysis is used to set upper limits on the cross-section of WIMP-nucleus interactions. We exclude new parameter space for WIMPs heavier than 100 GeV/c${}^2$, with the strongest upper limit of $3.3 \times 10^{-39}$ cm${}^2$ for 130 GeV/c${}^2$ WIMPs at 90\% confidence level.
△ Less
Submitted 26 February, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
$^{222}$Rn emanation measurements for the XENON1T experiment
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (118 additional authors not shown)
Abstract:
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation me…
▽ More
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a $^{222}$Rn activity concentration of 10 $μ$Bq/kg in 3.2 t of xenon. The knowledge of the distribution of the $^{222}$Rn sources allowed us to selectively eliminate critical components in the course of the experiment. The predictions from the emanation measurements were compared to data of the $^{222}$Rn activity concentration in XENON1T. The final $^{222}$Rn activity concentration of (4.5 $\pm$ 0.1) $μ$Bq/kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.
△ Less
Submitted 25 November, 2020; v1 submitted 29 September, 2020;
originally announced September 2020.
-
Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (115 additional authors not shown)
Abstract:
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, c…
▽ More
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$σ$ (5$σ$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
△ Less
Submitted 17 November, 2020; v1 submitted 17 July, 2020;
originally announced July 2020.
-
Excess Electronic Recoil Events in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (114 additional authors not shown)
Abstract:
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is o…
▽ More
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4$σ$ significance, and a 3D 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae}<3.8 \times 10^{-12}$, $g_{ae}g_{an}^{eff}<4.8\times 10^{-18}$, and $g_{ae}g_{aγ}<7.7\times10^{-22} GeV^{-1}$, and excludes either $g_{ae}=0$ or $g_{ae}g_{aγ}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic moment signal is similarly favored over background at 3.2$σ$ and a confidence interval of $μ_ν \in (1.4,2.9)\times10^{-11}μ_B$ (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by $β$ decays of tritium at 3.2$σ$ with a trace amount that can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are reduced to 2.0$σ$ and 0.9$σ$, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at ($2.3\pm0.2$) keV (68% C.L.) with a 3.0$σ$ global (4.0$σ$ local) significance. We also consider the possibility that $^{37}$Ar may be present in the detector and yield a 2.82 keV peak. Contrary to tritium, the $^{37}$Ar concentration can be tightly constrained and is found to be negligible.
△ Less
Submitted 16 October, 2020; v1 submitted 17 June, 2020;
originally announced June 2020.
-
VUV Transmission of PTFE for Xenon-based Particle Detectors
Authors:
Lutz Althüser,
Sebastian Lindemann,
Michael Murra,
Marc Schumann,
Christian Wittweg,
Christian Weinheimer
Abstract:
Liquid xenon (LXe) based detectors for rare event searches in particle and astroparticle physics are optimized for high xenon scintillation light collection and low background rate from detector materials. Polytetrafluoroethylene (PTFE, Teflon) is commonly used to encapsulate the active LXe volume due to its high reflectance for VUV LXe scintillation light with peak emission at 178 nm. Reflectance…
▽ More
Liquid xenon (LXe) based detectors for rare event searches in particle and astroparticle physics are optimized for high xenon scintillation light collection and low background rate from detector materials. Polytetrafluoroethylene (PTFE, Teflon) is commonly used to encapsulate the active LXe volume due to its high reflectance for VUV LXe scintillation light with peak emission at 178 nm. Reflectance, transmission and number of background signals arising from PTFE depend on the thickness of the PTFE detector walls. In this work, we present VUV transmission measurements for PTFE of various thicknesses often considered in the design phase of LXe detectors. PTFE samples are measured in an apparatus previously used for reflectance measurements in LXe using collimated light at a wavelength of 178 nm. Measurements in vacuum as well as gaseous xenon are described by the Kubelka and Munk model, as well as by Beer-Lambert's law for samples of $\geq 0.7\,\mathrm{mm}$ thickness, yielding a transmission coefficient of $λ_\text{BL} = (0.89 \pm 0.05)\,\mathrm{mm}$. The PTFE wall thickness of the XENONnT dark matter experiment was optimized by these measurements and selected as $\geq 3\,\mathrm{mm}$.
△ Less
Submitted 19 October, 2020; v1 submitted 10 June, 2020;
originally announced June 2020.
-
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Authors:
J. Aalbers,
F. Agostini,
S. E. M. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
F. Amaro,
J. Angevaare,
V. C. Antochi,
B. Antunovic,
E. Aprile,
L. Arazi,
F. Arneodo,
M. Balzer,
L. Baudis,
D. Baur,
M. L. Benabderrahmane,
Y. Biondi,
A. Bismark,
C. Bourgeois,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Brünner,
G. Bruno
, et al. (141 additional authors not shown)
Abstract:
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would ben…
▽ More
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would benefit from a depleted target. A high-statistics observation of $pp$ neutrinos would allow us to infer the values of the weak mixing angle, $\sin^2θ_w$, and the electron-type neutrino survival probability, $P_e$, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, at an exposure of 300 ty. An observation of $pp$ and $^7$Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high (GS98) and low metallicity (AGS09) solar models with 2.1-2.5$σ$ significance, independent of external measurements from other experiments or a measurement of $^8$B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $^{131}$Xe.
△ Less
Submitted 20 December, 2020; v1 submitted 4 June, 2020;
originally announced June 2020.
-
Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe
Authors:
F. Agostini,
S. E. M. Ahmed Maouloud,
L. Althueser,
F. Amaro,
B. Antunovic,
E. Aprile,
L. Baudis,
D. Baur,
Y. Biondi,
A. Bismark,
P. A. Breur,
A. Brown,
G. Bruno,
R. Budnik,
C. Capelli,
J. Cardoso,
D. Cichon,
M. Clark,
A. P. Colijn,
J. J. Cuenca-García,
J. P. Cussonneau,
M. P. Decowski,
A. Depoian,
J. Dierle,
P. Di Gangi
, et al. (70 additional authors not shown)
Abstract:
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, u…
▽ More
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.
△ Less
Submitted 7 September, 2020; v1 submitted 25 March, 2020;
originally announced March 2020.
-
Energy resolution and linearity of XENON1T in the MeV energy range
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (113 additional authors not shown)
Abstract:
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XEN…
▽ More
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
△ Less
Submitted 9 September, 2020; v1 submitted 8 March, 2020;
originally announced March 2020.
-
Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (109 additional authors not shown)
Abstract:
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, whic…
▽ More
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.
△ Less
Submitted 18 August, 2020; v1 submitted 30 July, 2019;
originally announced July 2019.
-
Light Dark Matter Search with Ionization Signals in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (108 additional authors not shown)
Abstract:
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of $(22 \pm 3)$ tonne-days. Above $\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe…
▽ More
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of $(22 \pm 3)$ tonne-days. Above $\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe $<1 \, \text{event}/(\text{tonne} \times \text{day} \times \text{keV}_\text{ee})$, which is more than one thousand times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses $m_χ$ within $3-6\,\mathrm{GeV}/\mathrm{c}^2$, DM-electron scattering for $m_χ> 30\,\mathrm{MeV}/\mathrm{c}^2$, and absorption of dark photons and axion-like particles for $m_χ$ within $0.186 - 1 \, \mathrm{keV}/\mathrm{c}^2$.
△ Less
Submitted 17 December, 2019; v1 submitted 26 July, 2019;
originally announced July 2019.
-
XENON1T Dark Matter Data Analysis: Signal Reconstruction, Calibration and Event Selection
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad
, et al. (103 additional authors not shown)
Abstract:
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric $\mathrm{ton}\times\mathrm{year}$ exp…
▽ More
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric $\mathrm{ton}\times\mathrm{year}$ exposure of science data was collected between October 2016 and February 2018. This article reports on the performance of the detector during this period and describes details of the data analysis that led to the most stringent exclusion limits on various WIMP-nucleon interaction models to date. In particular, signal reconstruction, event selection and calibration of the detector response to nuclear and electronic recoils in XENON1T are discussed.
△ Less
Submitted 4 November, 2019; v1 submitted 11 June, 2019;
originally announced June 2019.
-
The XENON1T Data Acquisition System
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (108 additional authors not shown)
Abstract:
The XENON1T liquid xenon time projection chamber is the most sensitive detector built to date for the measurement of direct interactions of weakly interacting massive particles with normal matter. The data acquisition system (DAQ) is constructed from commercial, open source, and custom components to digitize signals from the detector and store them for later analysis. The system achieves an extrem…
▽ More
The XENON1T liquid xenon time projection chamber is the most sensitive detector built to date for the measurement of direct interactions of weakly interacting massive particles with normal matter. The data acquisition system (DAQ) is constructed from commercial, open source, and custom components to digitize signals from the detector and store them for later analysis. The system achieves an extremely low signal threshold below a tenth of a photoelectron using a parallelized readout with the global trigger deferred to a later, software stage. The event identification is based on MongoDB database queries and has over 97% efficiency at recognizing interactions at the analysis energy threshold. A readout bandwidth over 300 MB/s is reached in calibration modes and is further expandable via parallelization. This DAQ system was successfully used during three years of operation of XENON1T.
△ Less
Submitted 7 August, 2019; v1 submitted 3 June, 2019;
originally announced June 2019.
-
First observation of two-neutrino double electron capture in $^{124}$Xe with XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (106 additional authors not shown)
Abstract:
Two-neutrino double electron capture ($2ν$ECEC) is a second-order Weak process with predicted half-lives that surpass the age of the Universe by many orders of magnitude. Until now, indications for $2ν$ECEC decays have only been seen for two isotopes, $^{78}$Kr and $^{130}$Ba, and instruments with very low background levels are needed to detect them directly with high statistical significance. The…
▽ More
Two-neutrino double electron capture ($2ν$ECEC) is a second-order Weak process with predicted half-lives that surpass the age of the Universe by many orders of magnitude. Until now, indications for $2ν$ECEC decays have only been seen for two isotopes, $^{78}$Kr and $^{130}$Ba, and instruments with very low background levels are needed to detect them directly with high statistical significance. The $2ν$ECEC half-life provides an important input for nuclear structure models and its measurement represents a first step in the search for the neutrinoless double electron capture processes ($0ν$ECEC). A detection of the latter would have implications for the nature of the neutrino and give access to the absolute neutrino mass. Here we report on the first direct observation of $2ν$ECEC in $^{124}$Xe with the XENON1T Dark Matter detector. The significance of the signal is $4.4σ$ and the corresponding half-life $T_{1/2}^{2ν\text{ECEC}} = (1.8\pm 0.5_\text{stat}\pm 0.1_\text{sys})\times 10^{22}\;\text{y}$ is the longest ever measured directly. This study demonstrates that the low background and large target mass of xenon-based Dark Matter detectors make them well suited to measuring other rare processes as well, and it highlights the broad physics reach for even larger next-generation experiments.
△ Less
Submitted 24 April, 2019;
originally announced April 2019.
-
XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad,
J. P. Cussonneau
, et al. (101 additional authors not shown)
Abstract:
The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and ionization signals produced by interactions in target volume, to reconstruct energy and position, as well as the type of the interaction. The background rate in…
▽ More
The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and ionization signals produced by interactions in target volume, to reconstruct energy and position, as well as the type of the interaction. The background rate in the central volume of XENON1T detector is the lowest achieved so far with a liquid xenon-based direct detection experiment. In this work we describe the response model of the detector, the background and signal models, and the statistical inference procedures used in the dark matter searches with a 1 tonne$\times$year exposure of XENON1T data, that leaded to the best limit to date on WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c$^2$.
△ Less
Submitted 28 February, 2019; v1 submitted 28 February, 2019;
originally announced February 2019.
-
Constraining the Spin-Dependent WIMP-Nucleon Cross Sections with XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (105 additional authors not shown)
Abstract:
We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set ex…
▽ More
We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of $6.3\times10^{-42}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence level. The results are compared with those from collider searches and used to exclude new parameter space in an isoscalar theory with an axial-vector mediator.
△ Less
Submitted 30 April, 2019; v1 submitted 8 February, 2019;
originally announced February 2019.
-
Magnetoelectric Coupling by Giant Piezoelectric Tensor Design
Authors:
J. Irwin,
S. Lindemann,
W. Maeng,
J. J. Wang,
V. Vaithyanathan,
J. M. Hu,
L. Q. Chen,
D. G. Schlom,
C. B. Eom,
M. S. Rzchowski
Abstract:
Strain-coupled magnetoelectric (ME) phenomena in piezoelectric / ferromagnetic thin-film bilayers are a promising paradigm for sensors and information storage devices, where strain is utilized to manipulate the magnetization of the ferromagnetic film. In-plane magnetization rotation with an electric field across the film thickness has been challenging due to the virtual elimination of in-plane pie…
▽ More
Strain-coupled magnetoelectric (ME) phenomena in piezoelectric / ferromagnetic thin-film bilayers are a promising paradigm for sensors and information storage devices, where strain is utilized to manipulate the magnetization of the ferromagnetic film. In-plane magnetization rotation with an electric field across the film thickness has been challenging due to the virtual elimination of in-plane piezoelectric strain by substrate clam**, and to the requirement of anisotropic in-plane strain in two-terminal devices. We have overcome both of these limitations by fabricating lithographically patterned devices with a piezoelectric membrane on a soft substrate platform, in which in-plane strain is freely generated, and a patterned edge constraint that transforms the nominally isotropic piezoelectric strain into the required uniaxial strain. We fabricated 500 nm thick, (001) oriented [Pb(Mg$_{1/3}$Nb$_{2/3}$)O$_3$]$_{0.7}$-[PbTiO$_3$]$_{0.3}$ (PMN-PT) unclamped piezoelectric membranes with ferromagnetic Ni overlayers. Guided by analytical and numerical continuum elastic calculations, we designed and fabricated two-terminal devices exhibiting Ni magnetization rotation in response to an electric field across the PMN-PT. Similar membrane heterostructures could be used to apply designed strain patterns to many other materials systems to control properties such as superconductivity, band topology, conductivity, and optical response.
△ Less
Submitted 8 January, 2019;
originally announced January 2019.
-
First results on the scalar WIMP-pion coupling, using the XENON1T experiment
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (107 additional authors not shown)
Abstract:
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most non-relativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons, and therefore may dominate in…
▽ More
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most non-relativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons, and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, no significant excess is found, leading to an upper limit cross section of $6.4\times10^{-46}$ cm$^2$ (90 % confidence level) at 30 GeV/c$^2$ WIMP mass.
△ Less
Submitted 22 February, 2019; v1 submitted 29 November, 2018;
originally announced November 2018.
-
Dark Matter Search Results from a One Tonne$\times$Year Exposure of XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn,
J. Conrad
, et al. (95 additional authors not shown)
Abstract:
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra…
▽ More
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\ -3}\textrm{ (sys)}\pm3\textrm{ (stat)})$ events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant excess over background is found and a profile likelihood analysis parameterized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence level.
△ Less
Submitted 13 September, 2018; v1 submitted 31 May, 2018;
originally announced May 2018.
-
Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (94 additional authors not shown)
Abstract:
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two l…
▽ More
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two lower fields are in agreement with those from literature; additional measurements at a higher field of 366 V/cm are presented. The electronic and nuclear recoil discrimination as well as its dependence on the drift field and photon detection efficiency are investigated at these low energies. The results provide new measurements in the energy region of interest for dark matter searches using liquid xenon.
△ Less
Submitted 1 February, 2018; v1 submitted 28 September, 2017;
originally announced September 2017.
-
Search for Bosonic Super-WIMP Interactions with the XENON100 Experiment
Authors:
XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
Bütikofer,
J. Calven,
C. Capelli,
J. M. R. Cardoso
, et al. (97 additional authors not shown)
Abstract:
We present results of searches for vector and pseudo-scalar bosonic super-WIMPs, which are dark matter candidates with masses at the keV-scale, with the XENON100 experiment. XENON100 is a dual-phase xenon time projection chamber operated at the Laboratori Nazionali del Gran Sasso. A profile likelihood analysis of data with an exposure of 224.6 live days $\times$ 34\,kg showed no evidence for a sig…
▽ More
We present results of searches for vector and pseudo-scalar bosonic super-WIMPs, which are dark matter candidates with masses at the keV-scale, with the XENON100 experiment. XENON100 is a dual-phase xenon time projection chamber operated at the Laboratori Nazionali del Gran Sasso. A profile likelihood analysis of data with an exposure of 224.6 live days $\times$ 34\,kg showed no evidence for a signal above the expected background. We thus obtain new and stringent upper limits in the $(8-125)$\,keV/c$^2$ mass range, excluding couplings to electrons with coupling constants of $g_{ae} > 3\times10^{-13}$ for pseudo-scalar and $α'/α> 2\times10^{-28}$ for vector super-WIMPs, respectively. These limits are derived under the assumption that super-WIMPs constitute all of the dark matter in our galaxy.
△ Less
Submitted 7 September, 2017;
originally announced September 2017.