-
TEX (TEst stand for X-band) at LNF
Authors:
C. Di Giulio,
F. Cardelli,
S. Pioli,
D. Alesini,
M. Bellaveglia,
S. Bini,
B. Buonomo,
S. Cantarella,
G. Catuscelli,
M. Ceccarelli,
R. Ceccarelli,
M. Cianfrini,
R. Clementi,
E. Di Pasquale,
G. Di Raddo,
R. Di Raddo,
A. Falone,
A. Gallo,
G. Latini,
A. Liedl,
V. Lollo,
G. Piermarini,
L. Piersanti,
S. Quaglia,
L. A. Rossi
, et al. (5 additional authors not shown)
Abstract:
TEX facility if commissioned for high power testing to characterize accelerating structures and validate them for the operation on future particle accelerators for medical, industrial and research applications. At this aim, TEX is directly involved in the LNF leading project EuPRAXIA@SPARC_Lab. The brief description of the facility and its status and prospective will be provided.
TEX facility if commissioned for high power testing to characterize accelerating structures and validate them for the operation on future particle accelerators for medical, industrial and research applications. At this aim, TEX is directly involved in the LNF leading project EuPRAXIA@SPARC_Lab. The brief description of the facility and its status and prospective will be provided.
△ Less
Submitted 31 August, 2023; v1 submitted 6 August, 2023;
originally announced August 2023.
-
Design, optimization and experimental characterization of RF injectors for high brightness electron beams and plasma acceleration
Authors:
V. Shpakov,
D. Alesini,
M. P. Anania,
M. Behtouei,
B. Buonomo,
M. Bellaveglia,
A. Biagioni,
F. Cardelli,
M. Carillo,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Del Giorno,
L. Faillace,
M. Ferrario,
M. del Franco,
G. Franzini,
M. Galletti,
L. Giannessi,
A. Giribono,
A. Liedl,
V. Lollo,
A. Mostacci,
G. Di Pirro,
L. Piersanti
, et al. (8 additional authors not shown)
Abstract:
In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains info…
▽ More
In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains information about the improvements, that were introduced into the new photo-injector design from the machine maintenance point of view, and the benefits, that we gained by using the new technique to assemble the gun itself.
△ Less
Submitted 12 December, 2022;
originally announced December 2022.
-
SHERPAD: test of Slow high-efficiency extraction of Positrons from a Ring At DAFNE
Authors:
Paolo Valente,
Davide Annucci,
Oscar Roberto Blanco Garcia,
Marco Garattini,
Paola Gianotti,
Susanna Guiducci,
Andrea Liedl,
Mauro Raggi
Abstract:
The idea of using fixed-target annihilations of a high-energy positron beam on a target for producing a new, very feebly interacting particle has been exploited by the PADME experiment at LNF using the extracted beam from the LINAC in the BTF facility. Extracting the beam from a synchrotron would improve by several orders of magnitude the duty-cycle of the LINAC, thus greatly extending the physics…
▽ More
The idea of using fixed-target annihilations of a high-energy positron beam on a target for producing a new, very feebly interacting particle has been exploited by the PADME experiment at LNF using the extracted beam from the LINAC in the BTF facility. Extracting the beam from a synchrotron would improve by several orders of magnitude the duty-cycle of the LINAC, thus greatly extending the physics reach of such experiments. The option of substituting or complementing the standard, slow 1/3 of integer resonant extraction technique by using coherent phenomena in a bent crystal, like the channeling has been studied by the SHERPA experiment. Both using the DAFNE main positron ring or the smaller dam** ring (accumulator) as pulse extender of the LINAC have been considered.
We here propose to demonstrate the feasibility of this technique performing an experiment on the DAFNE positron main ring, installing in a suitable vacuum goniometer a thin Silicon crystal, bent in the (110) direction in order to provide a ~1 mrad kick, and then simulating the extraction process with a virtual septum: instead of performing a real extraction, the crossing of the gap of a septum magnet is simulated by detecting positrons at its position (at phase advance close to 1/4) by means of a Silicon pixel detector inserted in the ring, in a secondary vacuum of a Roman pot.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
Crystal slow extraction of positrons from DAFNE: the SHERPA project
Authors:
M. Garattini,
D. Annucci,
O. R. Blanco-Garcia,
P. Gianotti,
S. Guiducci,
A. Liedl,
M. Raggi,
P. Valente
Abstract:
The SHERPA project aim is to develop an efficient technique to extract a positron beam from one of the accelerator rings composing the DAFNE complex at the Frascati National Laboratory of INFN, setting up a new beam line able to deliver positron spills of O(ms) length, excellent beam energy spread and emittance. The most common approach to slowly extract from a ring is to increase betatron oscilla…
▽ More
The SHERPA project aim is to develop an efficient technique to extract a positron beam from one of the accelerator rings composing the DAFNE complex at the Frascati National Laboratory of INFN, setting up a new beam line able to deliver positron spills of O(ms) length, excellent beam energy spread and emittance. The most common approach to slowly extract from a ring is to increase betatron oscillations approaching a tune resonance in order to gradually eject particles from the circulating beam. SHERPA proposes a paradigm change using coherent processes in bent crystals to kick out positrons from the ring, a cheaper and less complex alternative. A description of this innovative non-resonant extraction technique is reported in this manuscript, including its performance preliminary estimation.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
First emittance measurement of the beam-driven plasma wakefield accelerated electron beam
Authors:
V. Shpakov,
M. P. Anania,
M. Behtouei,
M. Bellaveglia,
A. Biagioni,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. Del Dotto,
M. Diomede,
F. Dipace,
M. Ferrario,
M. Galletti,
A. Giribono,
A. Liedl,
V. Lollo,
L. Magnisi,
A. Mostacci,
G. Di Pirro,
L. Piersanti,
R. Pompili,
S. Romeo,
A. R. Rossi
, et al. (4 additional authors not shown)
Abstract:
Next-generation plasma-based accelerators can push electron beams to GeV energies within centimetre distances. The plasma, excited by a driver pulse, is indeed able to sustain huge electric fields that can efficiently accelerate a trailing witness bunch, which was experimentally demonstrated on multiple occasions. Thus, the main focus of the current research is being shifted towards achieving a hi…
▽ More
Next-generation plasma-based accelerators can push electron beams to GeV energies within centimetre distances. The plasma, excited by a driver pulse, is indeed able to sustain huge electric fields that can efficiently accelerate a trailing witness bunch, which was experimentally demonstrated on multiple occasions. Thus, the main focus of the current research is being shifted towards achieving a high quality of the beam after the plasma acceleration. In this letter we present beam-driven plasma wakefield acceleration experiment, where initially preformed high-quality witness beam was accelerated inside the plasma and characterized. In this experiment the witness beam quality after the acceleration was maintained on high level, with $0.2\%$ final energy spread and $3.8~μm$ resulting normalized transverse emittance after the acceleration. In this article, for the first time to our knowledge, the emittance of the PWFA beam was directly measured.
△ Less
Submitted 9 April, 2021;
originally announced April 2021.
-
Electron beam test of key elements of the laser-based calibration system for the muon $g$ $-$ $2$ experiment
Authors:
A. Anastasi,
A. Basti,
F. Bedeschi,
M. Bartolini,
G. Cantatore,
D. Cauz,
G. Corradi,
S. Dabagov,
G. DI Sciascio,
R. Di Stefano,
A. Driutti,
O. Escalante,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
A. Gioiosa,
D. Hampai,
D. W. Hertzog,
M. Iacovacci,
M. Karuza,
J. Kaspar,
A. Liedl,
A. Lusiani,
F. Marignetti
, et al. (8 additional authors not shown)
Abstract:
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam im**ing on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experi…
▽ More
We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam im**ing on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.
△ Less
Submitted 11 October, 2016;
originally announced October 2016.