-
New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver
Authors:
HAYSTAC Collaboration,
M. J. Jewell,
A. F. Leder,
K. M. Backes,
Xiran Bai,
K. van Bibber,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Maryam H. Esmat,
Sumita Ghosh,
Eleanor Graham,
Gene C. Hilton,
H. Jackson,
Claire Laffan,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
E. P. Ruddy,
M. Simanovskaia,
Sukhman Singh
, et al. (4 additional authors not shown)
Abstract:
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr…
▽ More
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.
△ Less
Submitted 26 January, 2023; v1 submitted 23 January, 2023;
originally announced January 2023.
-
Design, fabrication, and tuning of a THz-driven electron gun
Authors:
Samantha M. Lewis,
Julian Merrick,
Mohamed A. K. Othman,
Andrew Haase,
Sami Tantawi,
Emilio A. Nanni
Abstract:
We present the design, fabrication, and low power testing of a THz-driven field emission electron gun. The two cell standing-wave gun is designed to be powered by a 110 GHz gyrotron and produce 360 keV electrons with 500 kW of input power. Several gun structures were fabricated using a high precision diamond turned mandrel and copper electroforming. The field emission source is a copper tip with a…
▽ More
We present the design, fabrication, and low power testing of a THz-driven field emission electron gun. The two cell standing-wave gun is designed to be powered by a 110 GHz gyrotron and produce 360 keV electrons with 500 kW of input power. Several gun structures were fabricated using a high precision diamond turned mandrel and copper electroforming. The field emission source is a copper tip with a 50 $μ$m radius inserted halfway into first cell. The frequencies of the cavity resonances were mechanically tuned using azimuthal compression. This work presents electromagnetic and particle simulations of the design and cold test measurements of the fabricated structures.
△ Less
Submitted 30 March, 2022; v1 submitted 29 March, 2022;
originally announced March 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
Exploration of Wire Array Metamaterials for the Plasma Axion Haloscope
Authors:
M. Wooten,
A. Droster,
Al Kenany,
D. Sun,
S. M. Lewis,
K. van Bibber
Abstract:
A plasma haloscope has recently been proposed as a feasible approach to extend the search for dark matter axions above 10 GHz ($\sim$ 40 $μ$eV), whereby the microwave cavity in a conventional axion haloscope is supplanted by a wire array metamaterial. As the plasma frequency of a metamaterial is determined by its unit cell, and is thus a bulk property, a metamaterial resonator of any frequency can…
▽ More
A plasma haloscope has recently been proposed as a feasible approach to extend the search for dark matter axions above 10 GHz ($\sim$ 40 $μ$eV), whereby the microwave cavity in a conventional axion haloscope is supplanted by a wire array metamaterial. As the plasma frequency of a metamaterial is determined by its unit cell, and is thus a bulk property, a metamaterial resonator of any frequency can be made arbitrarily large, in contrast to a microwave cavity which incurs a steep penalty in volume with increasing frequency. We have investigated the basic properties of wire array metamaterials through $S_{21}$ measurements in the 10 GHz range. Excellent agreement with theoretical models is found, by which we project achievable quality factors to be of order $10^{4}$ in an actual axion search. Furthermore, schemes for tuning the array over a usable dynamic range ($30\%$ in frequency) appear practical from an engineering perspective.
△ Less
Submitted 27 January, 2023; v1 submitted 25 March, 2022;
originally announced March 2022.
-
A quantum-enhanced search for dark matter axions
Authors:
K. M. Backes,
D. A. Palken,
S. Al Kenany,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Gene C. Hilton,
Sumita Ghosh,
H. Jackson,
S. K. Lamoreaux,
A. F. Leder,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
N. M. Rapidis,
M. Simanovskaia,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
Leila R. Vale,
E. C. van Assendelft,
K. van Bibber,
H. Wang
Abstract:
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we do…
▽ More
In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.
△ Less
Submitted 4 August, 2020;
originally announced August 2020.
-
An improved analysis framework for axion dark matter searches
Authors:
D. A. Palken,
B. M. Brubaker,
M. Malnou,
S. Al Kenany,
K. M. Backes,
S. B. Cahn,
Y. V. Gurevich,
S. K. Lamoreaux,
S. M. Lewis,
R. H. Maruyama,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
K. van Bibber,
L. Zhong,
K. W. Lehnert
Abstract:
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f…
▽ More
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.
△ Less
Submitted 28 July, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.
-
Characterization of the HAYSTAC axion dark matter search cavity using microwave measurement and simulation techniques
Authors:
Nicholas M. Rapidis,
Samantha M. Lewis,
Karl A. van Bibber
Abstract:
Many searches for axion cold dark matter rely on the use of tunable electromagnetic resonators. Current detectors operate at or near microwave frequencies and use cylindrical cavities with cylindrical tuning rods. The cavity performance strongly impacts the signal power of the detector, which is expected to be very small even under optimal conditions. There is strong motivation to characterize the…
▽ More
Many searches for axion cold dark matter rely on the use of tunable electromagnetic resonators. Current detectors operate at or near microwave frequencies and use cylindrical cavities with cylindrical tuning rods. The cavity performance strongly impacts the signal power of the detector, which is expected to be very small even under optimal conditions. There is strong motivation to characterize these microwave cavities and improve their performance in order to maximize the achievable signal power. We present the results of a study characterizing the HAYSTAC (Haloscope At Yale Sensitive to Axion Cold dark matter) cavity using bead perturbation measurements and detailed 3D electromagnetic simulations. This is the first use of bead perturbation methods to characterize an axion haloscope cavity. In this study, we measured impacts of misalignments on the order of 0.001 in and demonstrated that the same impacts can be predicted using electromagnetic simulations. We also performed a detailed study of mode crossings and hybridization between the TM$_{010}$ mode used in operation and other cavity modes. This mixing limits the tuning range of the cavity that can be used during an axion search. By characterizing each mode crossing in detail, we show that some mode crossings are benign and are potentially still useful for data collection. The level of observed agreement between measurements and simulations demonstrates that finite element modeling can capture non-ideal cavity behavior and the impacts of very small imperfections. 3D electromagnetic simulations and bead perturbation measurements are standard tools in the microwave engineering community, but they have been underutilized in axion cavity design. This work demonstrates their potential to improve understanding of existing cavities and to optimize future designs.
△ Less
Submitted 30 January, 2019; v1 submitted 6 September, 2018;
originally announced September 2018.
-
Results from phase 1 of the HAYSTAC microwave cavity axion experiment
Authors:
L. Zhong,
S. Al Kenany,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
D. H. Speller,
I. Urdinaran,
K. A. van Bibber
Abstract:
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range…
▽ More
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Photonic-Band-Gap Gyrotron Amplifier with Picosecond Pulses
Authors:
Emilio A. Nanni,
Sudheer Jawla,
Samantha M. Lewis,
Michael A. Shapiro,
Richard J. Temkin
Abstract:
We report the amplification of 250~GHz pulses as short as 260~ps without observation of pulse broadening using a photonic-band-gap circuit gyrotron traveling-wave-amplifier. The gyrotron amplifier operates with 38~dB of device gain and 8~GHz of instantaneous bandwidth. The operational bandwidth of the amplifier can be tuned over 16 GHz by adjusting the operating voltage of the electron beam and th…
▽ More
We report the amplification of 250~GHz pulses as short as 260~ps without observation of pulse broadening using a photonic-band-gap circuit gyrotron traveling-wave-amplifier. The gyrotron amplifier operates with 38~dB of device gain and 8~GHz of instantaneous bandwidth. The operational bandwidth of the amplifier can be tuned over 16 GHz by adjusting the operating voltage of the electron beam and the magnetic field. The amplifier uses a 30~cm long photonic-band-gap interaction circuit to confine the desired TE$_{03}$-like operating mode while suppressing lower order modes which can result in undesired oscillations. The circuit gain is $>$55~dB for a beam voltage of 23~kV and a current of 700~mA. These results demonstrate the wide bandwidths and high gain achievable with gyrotron amplifiers. The amplification of picosecond pulses of variable lengths, 260-800~ps, shows good agreement with theory using the coupled dispersion relation and the gain-spectrum of the amplifier as measured with quasi-CW input pulses.
△ Less
Submitted 22 September, 2017;
originally announced September 2017.
-
Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
Authors:
S. Al Kenany,
M. A. Anil,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
I. Urdinaran,
K. A. van Bibber,
L. Zhong
Abstract:
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple…
▽ More
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.
△ Less
Submitted 22 February, 2017; v1 submitted 21 November, 2016;
originally announced November 2016.
-
First results from a microwave cavity axion search at 24 micro-eV
Authors:
B. M. Brubaker,
L. Zhong,
Y. V. Gurevich,
S. B. Cahn,
S. K. Lamoreaux,
M. Simanovskaia,
J. R. Root,
S. M. Lewis,
S. Al Kenany,
K. M. Backes,
I. Urdinaran,
N. M. Rapidis,
T. M. Shokair,
K. A. van Bibber,
D. A. Palken,
M. Malnou,
W. F. Kindel,
M. A. Anil,
K. W. Lehnert,
G. Carosi
Abstract:
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an orde…
▽ More
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.
△ Less
Submitted 9 February, 2017; v1 submitted 8 October, 2016;
originally announced October 2016.
-
Model selection via Bayesian information capacity designs for generalised linear models
Authors:
David C. Woods,
James M. McGree,
Susan M. Lewis
Abstract:
The first investigation is made of designs for screening experiments where the response variable is approximated by a generalised linear model. A Bayesian information capacity criterion is defined for the selection of designs that are robust to the form of the linear predictor. For binomial data and logistic regression, the effectiveness of these designs for screening is assessed through simulatio…
▽ More
The first investigation is made of designs for screening experiments where the response variable is approximated by a generalised linear model. A Bayesian information capacity criterion is defined for the selection of designs that are robust to the form of the linear predictor. For binomial data and logistic regression, the effectiveness of these designs for screening is assessed through simulation studies using all-subsets regression and model selection via maximum penalised likelihood and a generalised information criterion. For Poisson data and log-linear regression, similar assessments are made using maximum likelihood and the Akaike information criterion for minimally-supported designs that are constructed analytically. The results show that effective screening, that is, high power with moderate type I error rate and false discovery rate, can be achieved through suitable choices for the number of design support points and experiment size. Logistic regression is shown to present a more challenging problem than log-linear regression. Some areas for future work are also indicated.
△ Less
Submitted 26 October, 2016; v1 submitted 29 January, 2016;
originally announced January 2016.
-
Design of Experiments for Screening
Authors:
David C. Woods,
Susan M. Lewis
Abstract:
The aim of this paper is to review methods of designing screening experiments, ranging from designs originally developed for physical experiments to those especially tailored to experiments on numerical models. The strengths and weaknesses of the various designs for screening variables in numerical models are discussed. First, classes of factorial designs for experiments to estimate main effects a…
▽ More
The aim of this paper is to review methods of designing screening experiments, ranging from designs originally developed for physical experiments to those especially tailored to experiments on numerical models. The strengths and weaknesses of the various designs for screening variables in numerical models are discussed. First, classes of factorial designs for experiments to estimate main effects and interactions through a linear statistical model are described, specifically regular and nonregular fractional factorial designs, supersaturated designs and systematic fractional replicate designs. Generic issues of aliasing, bias and cancellation of factorial effects are discussed. Second, group screening experiments are considered including factorial group screening and sequential bifurcation. Third, random sampling plans are discussed including Latin hypercube sampling and sampling plans to estimate elementary effects. Fourth, a variety of modelling methods commonly employed with screening designs are briefly described. Finally, a novel study demonstrates six screening methods on two frequently-used exemplars, and their performances are compared.
△ Less
Submitted 18 October, 2015;
originally announced October 2015.
-
Uniformly Balanced Repeated Measurements Designs in the Presence of Subject Dropout
Authors:
Dibyen Majumdar,
Angela M Dean,
Susan M Lewis
Abstract:
Low, Lewis and Prescott (1999) showed that a crossover design based on a Williams Latin square of order 4 can suffer substantial loss of efficiency if some observations in the final period are unavailable. Indeed, if all observations are missing, the design becomes disconnected. We derive the information matrix for the direct effects of a Uniformly Balanced Repeated Measurements Design (UBRMD) i…
▽ More
Low, Lewis and Prescott (1999) showed that a crossover design based on a Williams Latin square of order 4 can suffer substantial loss of efficiency if some observations in the final period are unavailable. Indeed, if all observations are missing, the design becomes disconnected. We derive the information matrix for the direct effects of a Uniformly Balanced Repeated Measurements Design (UBRMD) in t periods when subjects may drop out before the end of the study and examine the maximum loss of information. The special case of loss of observations in the final period only is examined in detail. In particular we show that a UBRMD in t>= 5 periods remains connected when some or all observations in the final period are unavailable.
△ Less
Submitted 3 October, 2007;
originally announced October 2007.