-
Interferometric Single-Shot Parity Measurement in an InAs-Al Hybrid Device
Authors:
Morteza Aghaee,
Alejandro Alcaraz Ramirez,
Zulfi Alam,
Rizwan Ali,
Mariusz Andrzejczuk,
Andrey Antipov,
Mikhail Astafev,
Amin Barzegar,
Bela Bauer,
Jonathan Becker,
Umesh Kumar Bhaskar,
Alex Bocharov,
Srini Boddapati,
David Bohn,
Jouri Bommer,
Leo Bourdet,
Arnaud Bousquet,
Samuel Boutin,
Lucas Casparis,
Benjamin James Chapman,
Sohail Chatoor,
Anna Wulff Christensen,
Cassandra Chua,
Patrick Codd,
William Cole
, et al. (137 additional authors not shown)
Abstract:
The fusion of non-Abelian anyons or topological defects is a fundamental operation in measurement-only topological quantum computation. In topological superconductors, this operation amounts to a determination of the shared fermion parity of Majorana zero modes. As a step towards this, we implement a single-shot interferometric measurement of fermion parity in indium arsenide-aluminum heterostruct…
▽ More
The fusion of non-Abelian anyons or topological defects is a fundamental operation in measurement-only topological quantum computation. In topological superconductors, this operation amounts to a determination of the shared fermion parity of Majorana zero modes. As a step towards this, we implement a single-shot interferometric measurement of fermion parity in indium arsenide-aluminum heterostructures with a gate-defined nanowire. The interferometer is formed by tunnel-coupling the proximitized nanowire to quantum dots. The nanowire causes a state-dependent shift of these quantum dots' quantum capacitance of up to 1 fF. Our quantum capacitance measurements show flux h/2e-periodic bimodality with a signal-to-noise ratio of 1 in 3.7 $μ$s at optimal flux values. From the time traces of the quantum capacitance measurements, we extract a dwell time in the two associated states that is longer than 1 ms at in-plane magnetic fields of approximately 2 T. These results are consistent with a measurement of the fermion parity encoded in a pair of Majorana zero modes that are separated by approximately 3 $μ$m and subjected to a low rate of poisoning by non-equilibrium quasiparticles. The large capacitance shift and long poisoning time enable a parity measurement error probability of 1%.
△ Less
Submitted 2 April, 2024; v1 submitted 17 January, 2024;
originally announced January 2024.
-
Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
C. Goodman,
M. Guzzetti,
C. Hanretty,
S. Lee,
G. Leum,
L. J. Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
M. H. Awida,
D. Bowring,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
R. Khatiwada,
J. Brodsky,
G. Carosi,
L. D. Duffy
, et al. (31 additional authors not shown)
Abstract:
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion se…
▽ More
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes
Authors:
S. Chakrabarty,
J. R. Gleason,
Y. Han,
A. T. Hipp,
M. Solano,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
M. Goryachev,
E. Hartman,
B. T. McAllister,
A. Quiskamp,
C. Thomson,
M. E. Tobar,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
T. Braine,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg
, et al. (22 additional authors not shown)
Abstract:
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and…
▽ More
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.
△ Less
Submitted 28 March, 2023; v1 submitted 7 March, 2023;
originally announced March 2023.
-
Search for a dark-matter induced Cosmic Axion Background with ADMX
Authors:
ADMX Collaboration,
T. Nitta,
T. Braine,
N. Du,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg,
G. Rybka,
J. Sinnis,
John Clarke,
I. Siddiqi,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
R. Khatiwada,
G. Carosi
, et al. (23 additional authors not shown)
Abstract:
We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analys…
▽ More
We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analysis strategy, which searches for a C$a$B induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a C$a$B originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband RF signals, such as other forms of a C$a$B or even high-frequency gravitational waves.
△ Less
Submitted 3 October, 2023; v1 submitted 10 March, 2023;
originally announced March 2023.
-
ADMX-Orpheus First Search for 70 $μ$eV Dark Photon Dark Matter: Detailed Design, Operations, and Analysis
Authors:
R. Cervantes,
G. Carosi,
C. Hanretty,
S. Kimes,
B. H. LaRoque,
G. Leum,
P. Mohapatra,
N. S. Oblath,
R. Ottens,
Y. Park,
G. Rybka,
J. Sinnis,
J. Yang
Abstract:
Dark matter makes up 85% of the matter in the universe and 27% of its energy density, but we do not know what comprises dark matter. It is possible that dark matter may be composed of either axions or dark photons, both of which can be detected using an ultra-sensitive microwave cavity known as a haloscope. The haloscope employed by ADMX consists of a cylindrical cavity operating at the TM…
▽ More
Dark matter makes up 85% of the matter in the universe and 27% of its energy density, but we do not know what comprises dark matter. It is possible that dark matter may be composed of either axions or dark photons, both of which can be detected using an ultra-sensitive microwave cavity known as a haloscope. The haloscope employed by ADMX consists of a cylindrical cavity operating at the TM$_{010}$ mode and is sensitive to the QCD axion with masses of few $μ$eV. However, this haloscope design becomes challenging to implement for higher masses. This is because higher masses require smaller-diameter cavities, consequently reducing the detection volume which diminishes the detected signal power. ADMX-Orpheus mitigates this issue by operating a tunable, dielectrically-loaded cavity at a higher-order mode, allowing the detection volume to remain large. This paper describes the design, operation, analysis, and results of the inaugural ADMX-Orpheus dark photon search between 65.5 $μ$eV (15.8 GHz) and 69.3 $μ$eV (16.8 GHz), as well as future directions for axion searches and for exploring more parameter space.
△ Less
Submitted 9 November, 2022; v1 submitted 20 April, 2022;
originally announced April 2022.
-
Search for 70 μeV Dark Photon Dark Matter with a Dielectrically-Loaded Multi-Wavelength Microwave Cavity
Authors:
R. Cervantes,
G. Carosi,
C. Hanretty,
S. Kimes,
B. H. LaRoque,
G. Leum,
P. Mohapatra,
N. S. Oblath,
R. Ottens,
Y. Park,
G. Rybka,
J. Sinnis,
J. Yang
Abstract:
Microwave cavities have been deployed to search for bosonic dark matter candidates with masses of a few $μ$eV. However, the sensitivity of these cavity detectors is limited by their volume, and the traditionally-employed half-wavelength cavities suffer from a significant volume reduction at higher masses. ADMX-Orpheus mitigates this issue by operating a tunable, dielectrically-loaded cavity at a h…
▽ More
Microwave cavities have been deployed to search for bosonic dark matter candidates with masses of a few $μ$eV. However, the sensitivity of these cavity detectors is limited by their volume, and the traditionally-employed half-wavelength cavities suffer from a significant volume reduction at higher masses. ADMX-Orpheus mitigates this issue by operating a tunable, dielectrically-loaded cavity at a higher-order mode, which allows the detection volume to remain large. The ADMX-Orpheus inaugural run excludes dark photon dark matter with kinetic mixing angle $χ> 10^{-13}$ between 65.5 $μ$eV (15.8 GHz) and 69.3 $μ$eV (16.8GHz), marking the highest-frequency tunable microwave cavity dark matter search to date.
△ Less
Submitted 9 November, 2022; v1 submitted 7 April, 2022;
originally announced April 2022.
-
Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
S. Jois,
P. Sikivie
, et al. (26 additional authors not shown)
Abstract:
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search.…
▽ More
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
△ Less
Submitted 15 October, 2021;
originally announced October 2021.
-
Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
E. Burns,
R. Cervantes,
N. Crisosto,
N. Du,
H. Korandla,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason
, et al. (27 additional authors not shown)
Abstract:
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temp…
▽ More
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
△ Less
Submitted 29 December, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Axion Dark Matter eXperiment: Run 1B Analysis Details
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
M. Goryachev,
B. McAllister,
M. E. Tobar,
C. Boutan,
M. Jones,
B. H. Laroque,
N. S. Oblath
, et al. (23 additional authors not shown)
Abstract:
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire fre…
▽ More
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for Run 1B, motivating analysis choices informed by details specific to this run.
△ Less
Submitted 13 October, 2020;
originally announced October 2020.